Laserfiche WebLink
SHEET NOTES <br />MAY NOT BE REFERENCED ON THIS SHEET <br />A REFER TO SHEET A1.03 FOR ALL GENERAL NOTES <br />PERTAINING TO THE BUILDING PLANS <br />FORUME <br />Partial Second Floor Plan - Building T <br />el <br />7E=3i�i1Q�l� <br />B REFER TO SHEETS A1.04 & A1.05 FOR ALL <br />CONSTRUCTION ASSEMBLIES, (ALL INTERIOR <br />WALLS WITHIN UNITS ARE W-8 UNO; ALL <br />EXTERIOR WALLS ARE W-1 UNO) <br />C BUILDING TYPE I TO BE PROVIDED WI A FIRE <br />SPRINKLER SYSTEM DESIGNED PER NFPA-13. <br />BUILDING TYPES II & III TO BE PROVIDED WI A FIRE <br />SPRINKLER SYSTEM DESIGNED PER NFPA-13R <br />D FIRE PROTECTION CONTRACTOR SHALL PROVIDE <br />ENGINEERED SIGNED & SEALED SHOP DRAWINGS <br />THAT INCLUDE ALL PIPE SIZES, ELEVATIONS, <br />HEAD LOCATIONS, VALVES, INSPECTOR TESTS, <br />FLOW SWITCHES, TAMPER SWITCHES, <br />WEATHERPROOF MTL ACCESS PANEL, <br />DIMENSIONS, ETC, SHOP DRAWINGS SHALL BE <br />SUBMITTED TO OWNER'S INSURANCE <br />UNDERWRITERS, CITY FIRE PROTECTION <br />OFFICER, & ALL OTHER AUTHORITIES HAVING <br />JURISDICTION <br />E REFER TO ROOF FRAMING PLANS FOR ROOF <br />PITCH AND FRAMING INFORMATION. <br />KEY NOTES <br />MAY NOT BE REFERENCED ON THIS SHEET <br />01 NOT USED <br />02 2X4 WALL: FULL HEIGHT @ FIRST FLOOR, 42" HIGH <br />@ SECOND FLOOR <br />03 FLOOR DRAIN <br />LEGEND <br />MAY NOT BE REFERENCED ON THIS SHEET <br />DESIGNATES 1 HR FIRE RATING FOR <br />ADJACENT WALL <br />— E — E — PATH OF EGRESS <br />INDICATES SPECIFIC WALL TYPE, <br />ALL REFER TO SHEET A1.04 FOR WALL <br />ASSEMBLIES <br />r FE, FIRE EXTINGUISHER IN CABINET, <br />REFER TO GENERAL NOTES <br />FIRE SPRINKLER HEAD LOCATIONS, <br />O TYP. (SPRINKLER CONTRACTOR TO <br />VERIFY FINAL LOC. & # REQ.) <br />INT. LOAD BRG. WALLS <br />TRAVEL DISTANCE <br />MAY NOT BE REFERENCED ON THIS SHEET <br />BUILDING TYPE I TRAVEL DISTANCE FROM UNIT @ 3RD <br />FLOOR TO OUT OF BUILDING ON 1ST FLOOR =151 LF <br />BUILDING TYPE II TRAVEL DISTANCE FROM UNIT @ 3RD <br />FLOOR TO OUT OF BUILDING ON 1 ST FLOOR =167 LF <br />BUILDING TYPE III TRAVEL DISTANCE FROM UNIT @ 3RD <br />FLOOR TO OUT OF BUILDING ON 1ST FLOOR =151 LF <br />E KEY PLAN <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Meetinghouse <br />at Zephyrhills <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />11125/09 <br />, Progress Set <br />12109M <br />60% Progress Set <br />12/17/09 <br />Bid Set <br />03/02/10 <br />Permit Set <br />11/02/10 5 <br />01117/11 6 <br />EDITED BY: <br />BUTIONS: <br />SHEET REVISIONS: <br />Owner Revision <br />Owner Revision 2 <br />i PROJECT NO. 09-2587 <br />z <br />0 <br />rn <br />Building Type I <br />W <br />Partial Second Floor <br />Plan <br />W <br />T <br />D <br />U <br />W <br />F- <br />I <br />U <br />Q A5.13 <br />0 <br />U. <br />0 <br />