Laserfiche WebLink
_ __-_1_1 _ I I ' I _ _ I I I I I I I 1 11 11 I 'l'Igrrtl I I I <br />1. A minimum cover of 36" shall be used on all <br />water mains. Water Main 10' Min. Separation <br />2. A minimum vertical separation of 18" shall be <br />required between crossing water mains and \11C <br />sanitary sewer lines. <br />Sanitary Sewer Line INLET <br />SEWER <br />1. All water lines that are parallel to OUTLET <br />M sanitary sewer lines shall be separated SEWER <br />ao by a minimum clearance of 10 feet. <br />i Sanitary Sewer Line 2. All water lines that are parallel to w 6' X 6' X 4' X 4' <br />:� fl- STD. P.V.C. <br />sanitary sewer lines and are separated DOUBLE Y BRANC <br />C.I. CLEANOUT COVER STREET WITHOUT CURB + STREET WITH CURB, <br />3. When vertical separation of 18" is not possible the by a distance of less than 10 feet Shall U.S. FOUNDARY & MANUFACTURING CORP. SINGLE SERVICE DOUBLE SERVICE TRENCH <br />sewer line shall be either cased in steel casing or be constructed according to either Option c. USF 7621 REVERSIBLE HANDHOLE RING AND FE RING TRENCH 1 MAIN SEWER WIDTH <br />concrete the full length of the Pipe, so as not "A", "B", or "C" as described below. AND C.I. COVER I <br />to allow a joint to be within 10 of the water main. FLOW 6' P.V.C.-s0• BEND CURB <br />8' X 6' , (SHORT RADIUS) , <br />Option A - Construct water line a minmum P.V.C. WYE <br />of 18" above the sewer and to <br />R/W OR EASEMENT LINE STREET, ALLEY, EASEMENT, ?;;, , , - •. <br />Water Main �� one side. Water line and Sewer R/W OR PROPERTY LINE <br />shall be constructed of D.I.P. 4' MIN. HOUSE CONNECTION <br />_" _ <br />and the water and sewer joints --- ,.� -- --- LINE <br />PLUG 4 SEAL 6' P.V.C. 45' BE <br />10' Min. 10' Min. shall be Staggered. - C1 -' (SHORT RADIUS) 6' P.V.C. BEND <br />i _--- AS REQUIRED 76, P.V.C. <br />-- N --- MARKER, PAINTED GREEN ' SERVICE <br />0Option B - Case the sewer lines in steel �; 8' X 6' P.V.C. WYE. LATERAL <br />Less than casing. _—_—_ _ _—_ —_ (BRANCHES TO BE <br />18' Sanitary Sewer Line g LOCATED IN THE FIELD) <br />CONCRETE SIDEWALK FINISHED GRADE <br />Separation Option C - Case the sewer lines in concrete. 6" TRENCH WIDTH ALL ENDS TO BE <br />P �--�{ 6„ PLUGGED & SEALED <br />TRENCH W/STD. STOPPERS <br />Case 2— Water Mains and Sewer Case 1— Water Main and Sanitary Sewer • a. WIDTH 6'P.V.C. OR PLUGS <br />NOTE: ROAD SURFACE a^•a • SERVICE LATERAL r� OF MAIN SEWER HOUSE CONNECT ON <br />lines crossing. lines parallel. STEEL TROWEL FINISH DROP MANHOLE TO BE USED WHEN THE `, . <br />POTABLE WATER AND SANITARY SEWER CONFLICT DETAIL DIFFERENCE BETWEEN INVERTS IS 2' PLAN <br />OR MORE. CURB <br />DROP MANHOLE Al <br />(BENCH AND INVERTS) <br />RIGHT OF WAY VARIES L <br />SIDEWALK 24' <br />8" PVC PIPE z x¢ CURB g GUTTER MIN. <br />2 <br />Update per new site <br />plan. <br />07/15/10 <br />1 <br />Per City comments. <br />05/08/08 <br />No. <br />Revisions <br />Date <br />MIN. 12 LONG T <br />STREET ALLEY EASEMENT, <br />TEMPORARY BLOW -OFF ASSEMBLY RED BRICK M R/w, ❑k PR❑PARTY LINE MIN. <br />TO BE REMOVED AFTER TESTING PVC CLEAN -OUT AT R/W LINE OR EASEMENT LINE <br />TOP OF <br />INLET TREATED WOOD MARKER PAVEMEN I DEPTH 7'-0' 3 <br />SEWER WYE BRANCH STAKE, 2' X 4' OR GREATER M <br />O TO BE DETERMINED IN TR?TCH <br />CONCRETE VALVE PAD6' P.V.C. 0 <br />J THE FIELD. MIN. WWITH I.D. TAG SERVICE PIPE SERVICE LATERAL6' P.V.C. SERVICENL� THE (TYPJ 1% MIN. SLOPE LATERAL CONCRETE CRADLE LL�WORD (WATER) ON COVER 6' MIN. R/W LINE 0 <br />DEPTH LESS STREET ❑ 1�1 __—THAN 7'-Y +� <br />A TO BE DETERMINED IN <br />FINAL GRADE p I OUTLET THE FIELD 60• MAX. 6' X 6' X 4' X 4' ST X Q <br />MIN. SLOPE 1/8' PE MAX O U- <br />a n ' to SEWER 4 P.V,C. DOUBLE 'Y' BRANCH O <br />PLUG <br />SEAL 8 SLOPE WHERE UNDISTURBED t <br />FOOT. USE GREATER <br />EART <br />CONNECTION BY CUSTOMER E <br />(TYPJ 4' MIN. <br />•'`••',.v �'r,;;�`+'•� 6 � 1 �;�l,t "ti>������ � POSSIBLE STREET WITHOUT CURB STREET WITH CURB <br />2" cALv. COUPLING WITH -_ SINGLE SERVICE CONNECTION DOUBLE SERVICE CONNECTION <br />rn <br />BPLUG ELOW NGRADEUNDISTURBED MATERIAL <br />ED 4" _._ ..._.__._- ", _.:. I Co _ <br />Z C <br />DEPTH LESS THAN 7'-0' DEPTH 7'-0' ❑R GREATER It c <br />J pip C <br />VALVE BOX (TOP SECTION) UJ <br />VALVE BOX FLOW SANITARY SEWER MAIN (TYPE 'A') I (TYPE 'B') t• M C 4) <br />C.I. SLIP TYPE <br />♦ _ C <br />c <br />n SECTION aC z I* uj d W <br />c `O (D w o <br />p`" NOTE: - CONTRACTOR SHALL MAKE, ON A CLEAN SET OF PLANS, THE FINAL STATIONING OR C to rL <br />E <br />DISTANCE AND DIRECTION FROM MANHOLE OF EACH SERVICE LATERAL AND THEN GIVE co <br />TO ENGINEER FOR RECORD PURPOSES. CA FL 00 i0 0 <br />- INLET PROVIDE 2' x 4' PRESSURE TREATED WOOD MARKER STAKE AT ALL SANITARY SERVICES <br />d !s (INCLUDE IN PIPE PRICE), TOP OF STAKE TO BE PAINTED WITH GREEN PAINT. <br />WATER MAIN SEWER A ' �i A <br />THE MINIMUM DIAMETER OF ALL SERVICE LATERALS SHALL BE 6 INCHES. <br />STEEL TROWEL FINISH <br />SANITARY SEWER - SINGLE WYE CONNECTION SEWER LATERAL <br />TAPPED PLUG <br />GATE VALVE OR REDUCER AND TYPICAL CLEAN -OUT CONNECTION <br />STANDARD MANHOLE <br />NOTES: (BENCH AND INVERTS) <br />- MECHANICAL JOINTS/UNDERGROUND PIPING SHALL BE RESTRAINED AS SPECIFIED <br />IN JOINT RESTRAINT TABLE (DETAIL 46) <br />- VALVE EXTENSION ROD SHALL BE UTILIZED, AS NECESSARY, SO THAT VALVE OPERATING <br />R NUT IS A MAXIMUM 0F 3 BELOW GRADE. <br />PERMANENT CU <br />BLOW -OFF DETAIL '0 <br />NOTE: NOTE: <br />CONNECTION BY CUSTOMER CU <br />a <br />NOTE: ECCENTRIC CONES PRECAST CONCRETE <br />PRECAST CONCRETE ARE ACCEPTABLE, SET <br />SHALL ATTAIN A MINIMUM IN LINE WITH FLOW. SHALL ATTAIN A MINIMUM C <br />COMPRESSIVE STRENGTH EXTERIOR COATING COMPRESSIVE STRENGTH CONCRETE WALK O 0 V u) <br />OF 4,000 p.s.i. AT 28 DAYS. KOPPERS BITUMASTIC OF 4,000 p.s.i. AT 28 DAYS. PRECAST CONCRETE MARKER, PAINTED GREEN V O •CU <br />p C.I. MANHOLE FRAME & COVER BLACK SOLUTION, C.I. MANHOLE FRAME & COVER SHALL ATTAIN A MINIMUM V �A' <br />2 COATS. DOUBLE WYE BRANCH 05 W <br />USF NO. 170-E ORS OR EQUAL OR USF NO. 170-E ORS OR EQUAL COMPRESSIVE STRENGTH C.I. CLEANOUT COVER Q <br />I W/ WORD "SANITARY", TYPE II PORTLAND I W/ WORD "SANITARY", <br />H-20 LOAD RATED. CEMENT MUST BE 4. H-20 LOAD RATED. OF 4,000 p.s.i. AT 28 DAYS. CAP co <br />4. <br />USED IN THE C.I. MANHOLE FRAME & COVER O I..L. <br />2" BELOW MANHOLE FINISHED GRADE 2" BELOW MANHOLE FINISHED GRADE USF NO. 170-E ORS OR EQUAL <br />(TYP. ALL MANHOLES) MANUFACTURING (TYP. ALL MANHOLES) I W/ WORD "SANITARY", r , C <br />PROCESS NOTE: CENTER RING & COVER H-20 LOAD RATED. f- TO SANITARY SEWER MAIN - �/ <br />BRICK LEVELING COURSE BRICK LEVELING COURSE TYPE ALL MANHOLE MANHOLES) FINISHED GRADE I P PL r <br />( SERVICE PIPE <br />12" MAX. 12" WIDE 12" MAX. CD <br />WRAPID SEAL 12' WIDE WRAPID SEAL R/W OR EASEMENT LINE (n Q <br />PRECAST ° �— 2 IA. ALL PRECAST 2' IA• • JOINTS TO BE BRICK LEVELING COURSE— <br />ALL(� AQ�' <br />UNITS MFG. T UNITS MFG. IN SEALED W/ 0-RING 12" WIDE 8" MAX. / MARKER, PAINTED GREEN O ' V <br />ACCORDANCE W/ ACCORDANCE W/ SEALS OR SINGLE <br />A.S.T.M. SPEC. JOINTS TO BE OFFSET SEAL WRAPID SEAL d O <br />C-478 , •' , • A.S.T.M. <br />. SPEC. °: ° • <br />SEALED W/ 0-RING (ASTM C-443) ALL PRECAST ° 22)IA..�a a ` <br />SEALS OR SINGLE UNITS MFG. IN ° �^ <br />OFFSET SEAL j ." ACCORDANCE W/ <br />(ASTM C-443) y WRAPID SEAL A.S.T.M. SPEC. CONNECTION BY CUSTOMER U <br />WRAPID SEAL 3" MIN- . ° C-478 <br />F ' 6" WIDE 5' OR LESS <br />NOTE: 6" WIDE I • EXTERIOR COATING, PLAN <br />ECCENTRIC CONES KOPPERS BITUMASTIC _ <br />ARE ACCEPTABLE, SET w — — w BLACK SOLUTION, GROUT R/W OR EASEMENT LINE <br />IN LINE WITH FLOW. 5" MIN. J 2 COATS. C.I. CLEANOUT COVER <br />T m ° Q OR U.S. FOUNDARY & MANUFACTURING CORP. <br />TYPE II PORTLAND USF 7621 REVERSIBLE HANDHOLE RING AND FE RING MARKER, PAINTED GREEN <br />C_ > =sue' ,,3: <br />5" MIN. > > CEMENT MUST BE AND C.I. COVER <br />WRAPID SEAL • USED IN THE <br />• WRAPID SEAL MANUFACTURING CONCRETE SIDEWALK 6„ FINISHED GRADE <br />° ° • • ° <br />EXTERIOR COATING, 6" WIDE • i w ° ° ° • ° e ° ° ° ° ° ° • °e• ° a ' a ° ° + o • • 10" MIN. 6" <br />KOPPERS BITUMASTIC 6" WIDE NOTE: ° • e e ° ° o e ° ° ° e <br />BLACK SOLUTION, INLET T ROAD SURFACE \ <br />2 COATS. I� SEWER • '• w ECCENTRIC CONES i a <br />T Of ARE ACCEPTABLE, SET a.. `e a o '• a Y '�.•� <br />OR 4'-0' DIA. FLEXIBLE BOOT W/ 0— IN LINE WITH FLOW. /f57 WHITE STONE a F a c� <br />TYPE II PORTLAND S.S. STRAP CLAMPS a_— 4'-O" DIA. c,'• <br />FLEXIBLE BOOT W/ UNDISTURBED •% �'• <br />CEMENT MUST BE ° SOIL +, <br />USED IN THE (ASTM C-923) <br />S.S. STRAP CLAMPS CURB � <br />MANUFACTURING N (ASTM C-923) <br />• NOTE: - A BEDDING OF CLASS I, CLASS II, OR CLASS III MATERIAL <br />SHALL BE REQUIRED WHEN THE MANHOLE BOTTOM CANNOT z a ]VI <br />91 P <br />POURED IN s • •• ._ BE INSTALLED ON UNDIST REED SO OR IF THE NATIVE SOIL 8" PVC PIPE <br />L U IL <br />'., . IS CLASS IV OR CLASS V MATERIAL. CIO $UP.�; <br />' PLACE CONC. MIN. 12" LONG M i <br />Vas <br />3' CLEAR OR PRE -CAST 3" CLEAR - THIS TYPE OF CONSTRUCTION SHALL BE LIMITED TO DEPTHS Ll 04 <br />• - + • . • . • • • • ° ° ° OF (0-5) FEET. PVC CLEAN -OUT AT R/W LINE OR EASEMENT LINE • ' • •r s <br />EXTERIOR COATING SHALL BE KOPPERS BITUMASTIC BLACK SOLUTION, / RED BRICK <br />GROUT FILLET SERVICE PIPE raiberele�, <br />NO. 4 REBAR AT 12" O.C. NO. 4 REBAR AT 12" O.C. SLOPE GROUT ON EACH 2 COATS. 1% MIN. SLOPE DOUBLE WYE BRANCH Nov 4, 2010 <br />REINFORCE PER EACH WAY GROUT FILLET EACH WAY <br />SLOPE GROUT ON EACH SIDE OF FLOW CHANNELS - WRAPID SEAL MUST BE USED ON ALL JOINTS, CASTINGS AND RISER RINGS. Date <br />A.S.T.M. C-478 SIDE OF FLOW CHANNELS PIPE & REINFORCE PER WRAPID SEAL MUST BE USED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. <br />ASTM C-478 <br />NOTE: 1. <br />WRAPID SEAL MUST BE USED ON ALL JOINTS, CASTINGS AND RISER RINGS: ON ALL JOINTS <br />FITTINGS <br />- PASCO COUNTY SHALL HAVE THE OPTION OF SPECIFYING THE TYPE OF INTERIOR LINING <br />ON AIR RELEASES, MANHOLES, GREASE/WATER, OIL/WATER SEPARATORS, AND WETWELLS. <br />NOTE: 1. <br />WRAPID SEAL MUST BE USED ON ALL JOINTS, CASTINGS AND RISER RINGS: ON ALL JOINTS <br />TO BE INSTALLED FOR EACH INDIVIDUAL MANHOLE. <br />2. <br />WRAPID SEAL MUST BE USED IN ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS. <br />ON AIR RELEASES, MANHOLES, GREASE WATER, OIL WATER SEPARATORS, AND WETWELLS. <br />/ / <br />- PASCO COUNTY SHALL HAVE THE OPTION OF REQUIRING A NEGATIVE PRESSURE TEST <br />/ <br />3. <br />PASCO COUNTY SHALL HAVE THE OPTION OF SPECIFYING THE TYPE OF INTERIOR LINING <br />2. <br />WRAPID SEAL MUST BE USED IN ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS. <br />PER ASTM C-1244 <br />TO BE INSTALLED FOR EACH INDIVIDUAL MANHOLE. <br />3. <br />PASCO COUNTY SHALL HAVE THE OPTION OF SPECIFYING THE TYPE OF INTERIOR LINING <br />- LIFT HOLES MUST NOT PENETRATE THE WALLS <br />\ <br />4. <br />PASCO COUNTY SHALL HAVE THE OPTION OF REQUIRING A NEGATIVE PRESSURE TEST <br />TO BE INSTALLED FOR EACH INDIVIDUAL MANHOLE. <br />CONNECTION BY CUSTOMER <br />PER ASTM C-1244 <br />4. <br />PASCO COUNTY SHALL HAVE THE OPTION OF REQUIRING A NEGATIVE PRESSURE TEST <br />5. <br />LIFT HOLES MUST NOT PENETRATE THE WALLS <br />PER ASTM C-1244 <br />UNDISTURBED MATERIAL <br />SANITARY SEWER MAIN ELEVATION <br />5. <br />LIFT HOLES MUST NOT PENETRATE THE WALLS <br />MANHOLE <br />STANDARD MANHOLE <br />DROP MANHOLE <br />SHALLOW CONSTRUCTION <br />SANITARY SEWER -DOUBLE WYE CONNECTION <br />(CLOSED BOTTOM) <br />AND TYPICAL CLEAN -OUT <br />Drawn: YZY <br />Checked: <br />Scale: As Shown <br />Dwg: Utility Details <br />Job No: 1372-10 <br />Sheet 21 <br />Of 27 Sheets <br />