Laserfiche WebLink
I A <br />' <br />EN❑INEER'S <br />NOTES: <br />1, <br />WIND <br />DESIGN SPEED = 110 (3 sec <br />gust) <br />2, <br />WIND <br />IMPORTANCE FACTOR = LO CONSTRUCTION <br />CATEGORY II <br />3, <br />WIND <br />EXPOSURE CATEGORY = "B" <br />4, <br />INTERNAL PRESSURE COEFFICIENT = <br />+/- 0.18 <br />(ENCLOSED BLDG) <br />5, <br />COMPONENTS <br />& CLADDING DESIGN PRESSURES <br />PER ASCE 7 <br />(ROOF) <br />ROOF > 10 to 30 degrees (110) <br />ZONE 1 <br />ZONE 2 ZONE 3 <br />@ 10 <br />SOFT +12.5/-19.9 @ 10 SQFT +12.5/-42.1 <br />@ 10 SOFT <br />+12.5/-42.1 <br />@ 20 <br />SOFT +11.4 /-19.4 @ 20 SOFT +11.4 /-38.2 <br />@ 20 SOFT <br />+11.4 /-38.2 <br />@ 50 <br />SOFT +10 /-M.6 @ 50 SOFT +10 /-33 <br />@ 50 SOFT <br />+10 /-33 <br />@ 100 <br />SOFT +10 /-18.1 @ 100 SOFT +10 /-29.1 <br />@ 100 SOFT <br />+10 /-29.1 <br />(WALLS) <br />ZONE 4 <br />ZONE 5 <br />@ 10 <br />SOFT +21,8 /-23.6 @ 10 SOFT +21.8 /-29.1 <br />@ 20 <br />SOFT +20.8 /-22.6 @ 20 SOFT +20.8/-27.2 <br />@ 50 <br />SOFT +19,5 /-21.3 @ 50 SOFT +19,5 /-24.6 <br />@ 100 <br />SQFT+18.5 /-20.4 @ 100 SQFT+18,5 /-22.6 <br />CODES: <br />FLORIDA RESIDENTIAL CODE, FLORIDA BUILDING CODE, 2007 EDITION, <br />WITH 2O09 SUPPLEMENT. <br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STURCTURES (ACI 530-02) <br />NATI❑NAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br />BUILDING CATEGORY: II <br />CONSTRUCTION TYPE: 5-B <br />GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL PERFORM THEIR WORK IN <br />ACCORDANCE WITH ALL APPLICABLE CODES GOVERNING EACH TRADE. <br />TECHINCAL CEDES SHALL APPLY; <br />PLUMBING, MECHANICAL, FUEL GAS ENERGY EFFICIENCY, ACCESSIBILITY, AND <br />2007 NATIONAL ELECTRICAL CODES` (NFPA 70). <br />❑RDINACE 92-19 - APPENDIX "J' TO FBC PLUMBING 2007 CODE. <br />1. TANK TYPE WATER CLOSET VOLUME - 1.6 GALLONS <br />2. WALL MOUNT WATER CLOSET VOLUME - 3.5 GALLONS. <br />3. WATER - FLOW RATE <br />PUBLIC FACILITIES 0.5 G.P.M. <br />PRIVATE FACILITIES 2.2 G.P.M. <br />SHOWER HEADS 2.5 G,P,M. <br />4. PVC IS NOT ALLOWED AS INTERIOR WATER PIPING, IT IS ALLOWED FOR WATER <br />SUPPLY LINES OUTSIDE OF THE HOME, CPVC IS ALLOWED FOR INTERIOR AND <br />EXTERIOR USE. THE MINIMUM SIZE SULLY LINE FOR A HOME IS 3/4'. <br />STRUCTURAL DESIGN CRITERIA <br />AREAS LIVE LOADS DEAD LOADS <br />DWELLING 40 psf 10 psf <br />BALCONIES 40 psf 10 psf <br />SHINGLE ROOF 20 psf 10 psf <br />BUILT-UP ROOF 20 psf 10 psf <br />TILE ROOF 25 psf 15 sf <br />THE F❑LL❑WING SHALL C❑M(�LY WITH THE 2007 FBC: <br />PORCHES AND BALCONIES - SECTION 1406,3 & 1012.4 <br />1. HANDRAILS - SECTION R311.5,6 <br />2. GUARDRAILS - SECTION R312 <br />ALL ENCLOSED PORCHES, DECKS AND SIMILAR STRUCTURES IF MORE THAN 30' ABOVE GRADE <br />SHALL HAVE A GUARDRAIL, GUARDRAILS ARE REUIRED TO BE A MINIMUM OF 36' HIGH FOR <br />DWELLING UNITS AND SHALL HAVE INTERMEDIATE RAILS OR ORNAMENTAL PATTERN SUCH THAT <br />A 4' DIAMETER SPHERE CANNOT PASS, <br />3. STAIRS - SECTION R311.5 <br />4. CHIMNEY & FIREPLACE - SECTION R1002 & R1004 (MFGR) <br />SECTION R1001 & R1003 (MAS) <br />5. EGRESS WINDOWS - SECTION R310,1 <br />ALL BEDROOMS SHALL HAVE AT LEAST ONE WINDOW APPROVED FOR EMERGENCY EGRESS. THE <br />MAXIMUM SILL HEIGHT FOR EGRESS WINDOWS IS 44 INCHES ABOVE THE FLOOR, THE CLEAR <br />OPENING HEIGHT IS 22', THE CLEAR OPENING WIDTH IS 20' AND THE NET CLEAR OPENING AREA <br />IS 5 SQ. FT. FOR GROUND FLOOR WINDOW AND 5.7 SQ, FT. FOR A SECOND STORY WINDOW, <br />GENERAL NOTES: <br />WINDOW AND DOOR MANUFACTURERS TO PROVIDE CERTIFICATION/RATING THAT THEIR WINDOWS AND DOORS <br />WILL WITHSTAND THE PRESSURE RESULTING FROM THE SPECIFIED DESIGN COMPONENTS AND CLADDING WIND <br />PRESSURE AND PR❑VIDE INSTALLATION INFORMATION WITH THEIR PRODUCTS, <br />CONTRACTOR TO INSTALL WINDOWS AND DOORS ACCORDING TO INSTRUCTIONS SUPPLIED BY MFGR AND HAVE <br />MANUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE AT THE TIME OF INSPECTION FOR REVIEW BY THE <br />BUILDING INSPECTOR. <br />ALL HURRICANE CLIPS, STRAPS AND FASTENERS ARE TO BE APPLIED ACCORDING TO THE FASTENERS <br />SCHEDULE AND MANUFACTURERS SPECIFICATIONS, IF DESIRED, EQUALVENT CONNECTORS MADE BY ANOTHER <br />SUPPLIER MAY BE USED IN PLACE OF THE CONNECTORS SHOWN. <br />THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTION OF VARIOUS <br />CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SH❑RING AND ANY OTHER TEMPORARY SUPPORTS <br />AS REQUIRED TO SAFELY COMPLETE THE WORK. <br />ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE TEMPERED GLASS <br />ALL WINDOWS WITHIN 24' OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18' OF FLR TO BE TEMPERED GLASS. (FBC, R308.4) <br />ATTIC ACCESS OPENING SHALL BE A MINIMUM OF 22' X 36'. ACCESS IS NOT REQUIRED FOR ATTICS WITH A CLEAR HEIGHT <br />OTTSTNTRELEDCTGALL <br />ATTICS <br />THAVE <br />LTS IGINSTALLED <br />AROLYED <br />AHEPOINOF INCHES, <br />ALL TRIIALWIRN6 INSTALLEDWIHIN6FT OF ATTICENTRYSH❑ULD BE PROTECTED CONTROLLED <br />GUARD STRIPS. <br />FIRE -STOPPING SHALL BE PROVIDED TO CUT OFF ALL VERTICAL AND HORIZONTAL CONCEALED DRAFT OPENINGS SUCH AS: <br />AR❑UNDLVDENTSA AND IPIPES. FIf EDSRTOPPINGLI CEILING, COVE <br />SHALL C❑NSISTN[IFTAIR 2-IINCHRN❑MIMALAT THE WOOD OR 2 ATHIICKONESOSM[IF I OPENINGS <br />NOMINAL WOOD. <br />ENTRY DOORS LOCATED IN GARAGES SHALL NOT OPEN DIRECTLY INTO BEDROOMS, <br />V TOP P <br />HURRICAN CLIPS ARE REQUIRED ON ALL TRUSSES AND RAFTERS. IF PLYWOOD OR OSB SHEATHING ODES NOT ❑ ER ❑ PLATE, E, <br />HURRICANE CLIPS MUST BE COVER BOTH TOP PLATES, <br />UPLIFT PROTECTION: PLYWOOD OR ❑SB COVERING ENTIRE EXTERIOR OF HOME WITH NAILS SPACED 3' D.C. AT TOP AND BOTTOM, <br />6' D.C. ON EDGES AND THE REMAINDER AT 12' D.C. OR PLAYW❑OD OR OSB AT CORNERS, WITH HURRICANE STRAPING ON EVERY <br />EXTERIOR STUD, CRIPPLE, JACKSTUD ETC. AT TOP AND BOTTOM, <br />SITE WORK: <br />FOUNDATION DESIGN IS BASED ON ALL ALLOWABLE SOIL PRESSURE ❑F 2000 PSF. SHOULD FIELD CONDITIONS <br />INDICATE THIS MINIMUM CONDITION DOES NOT EXIST, THE SUBCONTRACTOR SHALL IMMEDIATELY NOTIFY CONTRACTOR, <br />THE SUBGRADE UNDER THE NEW CONCRETE FOUNDATIONS SHALL BE COMPACTED TO 95% OPTIMUM DENSITY. <br />AS DETERMINED BY ASTM -1557 (MODIFIED PROCTOR) <br />S❑IL COMPACTION TESTS TO BE TAKEN BY A QUALIFIED SOILS LAB PRIOR TO POURING CONCRETE, <br />FOOTINGS SHALL BE NEAT EXCAVATED WHERE POSSIBLE WITH SIDES AND TOP EDGES FREE OF LOSE OR WET MATERIALS, <br />WHERE NEAT EXCAVATION IS NOT POSSIBLE FOOTINGS EXCAVATED SHALL BE ❑PEN CUT WITH EDGES FORMED AND BRACED. <br />ALL FO❑TINGS WITH FORMED EDGES SHALL BE BACKFILLED FROM BOTTOM TO TOP OF FOOTING WITH SELECT FILL, <br />THE BOTTOM EXCAVATION SHALL BE CLEAN AND DRY WITH ALL LOOSE MATERIAL REMOVED FOR AN ESSENTIALLY FLAT <br />BEARING SURFACE, PROVIDE S❑IL TREATMENT FOR TERMITES, <br />SET BACKS PER 106,3.1 <br />FOUNDATION INSPECTIONS <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRECHED FROM MARKER TO MARKER <br />TO VERIFY REQUIRED SETBACKS, <br />CAST IN PLACE CONCRETE <br />1, CONCRETE TO BE NORMAL WEIGHT WITH THE FOLLOWING MINIMUM COMPRESSIVE STRENGTHS AT 28 DAYS <br />FO❑TINGS SLAB ON GRADE, SLAB FILL.....3000 PSI <br />MASONARY WALL TIE BEAMS, TIE COLUMNS.....3000 PSI <br />2. CONCRETE SHALL BE READYMIX PER ASTM C94: <br />P❑RTLAND CEMENT - ASTM C150 <br />AGGREGATES - ASTM C33 (3/4' MAX) <br />NO CALCIUM CHL❑RIDE <br />AIR ENTRAINING - ASTM C260 <br />WATER REDUCING - ASTM C494 <br />FLYASH - ASTM C618-78 CLASS F (20% MAX) <br />WATER - CLEAN AND POTABLE <br />3. REINFORCING STEEL: ASTM A615 GRADE 60, DEFORMED BARS <br />4. REQUIRED SLUMP RANGE - 3" - 5' <br />5. WELDED WIRE FABRIC - ASTM A185 <br />FIBERMESH MAY BE SUBSTITUTED FOR W WF WHERE SPECIFICALLY STATED ON PLANS <br />6. MOISTURE BARRIER: 6 MIL POLYETHYLENE <br />7. CODES AND STANDARDS: <br />ACI 301 "SPEC FOR STRUCTURAL CONCRETE FOR BUILDINGS.' <br />ACI 305 "RECOMMENDED PRACTICE FOR HOT WEATHER CONCRETING.' <br />ACI 318 'BLDG CODE REQUIREMENTS FOR REINF. CONCRETE.' <br />ACI 315 'DETAILS AND DETAILING OF CONCRETE REINFORCEMENT,' <br />8. REFORCING BAR COVER: <br />FO❑TINGS 3' <br />COLUMNS 1 1/2' <br />BEAMS AND WALLS 1 1/2' <br />SLABS 3/4' (INTERIOR) 1 1/2' (EXTERIOR) <br />9. PROVIDE CORNER BARS AT ALL WALL FOOTING CORNERS TO MATCH HORIZ❑NTAL BARS, <br />(25' MINIMUM LAP) <br />10. ALL BUILDING SLAB ON GRADE SHALL BE NOMINAL 4' THICK, FIBER -MESH CONIC OR REINFORCED <br />WITH 6XG-W1.4 W.W.F. AS SPECIFIED PER PLAN ON 6 MIL VAPOR BARRIER. <br />11. ANCHOR BOLTS FOR WOOD PLATED TO CONCRETE OR MASONRY: <br />'J' BOLTS -USE 5/8'X8' 'J" BOLT WITH 7" ENBEDMENT AND 1' PROJECTION WHEN INSTALLED <br />PRIOR TO PLACING CONCRETE. WASHER 3"X3"X1/8' <br />EXPANSION ANCHORS -USE 5/8'X3 1/2' IMBED AT L❑CATIONS IN LIEU OF 5/8"X8" 'J" BOLTS <br />EPDXY ANCHORS IN CONCRETE -USE 5/8"X4-1/4" IMBED WITH 2' MIN EDGE DISTANCE <br />EPDXY ANCHORS IN TOP OF BLOCK WALLS -USE THREADED ROD (3/4'X7' INBED) <br />ON TOP OF 8' MASONRY WALLS WITH ADHESIVE OR ANCHOR BOND, WHEN <br />USED IN LIEU OF 5/8'X8' 'J' BOLTS <br />12.FOOTING SIZES SHOWN ARE TYPICAL ONLY FOR STATED SOIL BEARING PRESSURE AND CONSISTED <br />COMPACTION, CONTRACTOR SHALL BE RESPONSIBLE FOR FOOTINGS COMPLYING WITH THE DESIGN <br />REQUIREMENTS OF SPECIFIC SOIL CONDITIONS. <br />STEMWALL - 20' WIDE X 10' DEEP W/2 145 REBAR <br />MONOLITHIC - 1 STORY (20' DEEP X 12' WIDE), 2 STORY (20' DEEP X 16' WIDE) <br />2 STORY (20' DEEP X 16' WIDE) <br />F❑❑TER DEPTH - BOTTOM OF FO❑TER MUST BE MINIMUM OF 12' BELOW GRADE <br />FIREPLACE - 12' DEEP WITH MATT OF #5 REBAR <br />13.PROVIDE 1/2' EXPANSION JOINT MATERIAL BETWEEN ALL CONCRETE SLABS AND ABUTTING <br />CONCRETE OR MASONRY WALLS OCCURRING IN EXTERIOR OR UNHEATED AREA'S. <br />I _' [It JUL l' _-1 <br />j_� a �-- <br />d 0�------0 - <br />0 S 10° <br />----------------------------- 2 -- <br />t'I; O d <br />1�1 0,-- j Q <br />GABLE ROOFS <br />0 S 10` <br />MASONRY WALLS: <br />1, HOLLOW LOAD BEARING UNITS (CMU) SHALL CONFORM TO ASTM C90, NORMAL WEIGHT, TYPE I, <br />GRADE N. MINIMUM NET COMPRESSIVE STRENGTH = 1900 PSI <br />2. MORTAR SHALL BE TYPE M OR S AND CONFORM TO ASTM C270. <br />3. CONCRETE GROUT SHALL CONFORM TO ASTM C476: <br />3000 PSI AT 28 DAYS <br />3/8' MAXIMUM AGGREGATE <br />8' - 11' SLUMP <br />4. BARS SHALL HAVE MINIMUM CLEARANCE OF 1/2' FROM MASONRY. THE CLEAR DISTANCE BETWEEN <br />BARS SHALL NOT BE LESS THAN ONE BAR DIAMETER, NOR LESS THAN 1'. <br />5. VERTICAL REINF❑RCING SHALL BE AT ALL CORNERS, EACH JAMB OPENINGS OVER 4 FT. WIDE, UNDER ALL <br />GRIDER LOADS, AND NOT TO EXCEED 8'-0" ❑/C FOR STRAIGHT WALLS, OR AS SHOWN ON THE DRAWINGS. <br />6. FILL CELLS WITH CONCRETE GROUT AS SPECIFIED. PROVIDE ACI 90 DEGREE STANDARD HOOKS <br />7. REINFORCING BARSNDSHALL BEAMS, <br />STRAIGHT FOR BENDS AROUND CORNERS AND WHERE BENDS ❑R HOOKS <br />ARE DETAILED ON THE PLANS, <br />8. REINFORCING BARS SHALL BE LAPPED 25' MIN WHERE SPLICED AND SHALL BE WIRED TOGETHER. <br />9. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, IT SHALL NOT BE SLOPED MORE THAN ONE <br />HORIZONTAL IN SIX VERTICAL. DOWELS SHALL BE GROUTED INTO A CORE IN VERTICAL ALOGNMENT, EVEN THOUGH <br />IT IS IN AN ADJACENT CELL TO THE VERTICAL WALL REINF❑RCEMENT. <br />10.CLEANOUTS SHALL BE PROVIDED IN THE BOTTOM COURSE OF MASONRY IN EACH GROUT POUR WHEN THE POUR HEIGHT <br />EXCEEDS 5', PROVIDE 4"X4" OBSERVATION HOLE TO VERIFY CONCRETE GROUT PLACEMENT. <br />11. PLACE ALL MASONRY IN RUNNING BOND WITH 3/8' MORTAR JOINTS. PROVIDE COMPLETE COVERAGE FACE SHELL <br />MORTAR BEDDING, HORIZ❑NATL AND VERTICAL, FULLY MORTAR WEBS IN ALL COURSES OF PIERS, COLUMNS, AND <br />PILASTERS AND ADJACENT TO GROUTED CELLS, <br />12, PROVIDE 8'X8' PRECAST REINFORCED CONCRETE LINTELS OVER ALL MASONARY OPENINGS NOT SHOWN TO HAVE A <br />STRUCTURAL BEAM. MINIMUM END BEARING = 8" (MINIMUM CAPICITY OF 1000 PLF.) <br />13. PROVIDE METAL CAVITY CAPS, 6' WIRE MESH, OR DUR-O-STOP BY DUR-A-WALL, INC. WHERE REQUIRED TO RETAIN <br />GROUT IN VERTICAL CELLS, <br />PRE -CAST & PRE -STRESSED LINTELS <br />PRE -CAST AND PRE -STRESSED CONCRETE COMPONENTS SHALL BE USED AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. PRE -CAST LINTELS HAVE <br />BEEN REVIEWED AND PLACED BASED ON DESIGN ALLOWABLE LOAD INFORMATION PROVIDED BY SPECIFIED PROVIDER. ENGINEER <br />OF RECORD MUST PROVIDE IN WRITING ANY CHANGE IN LINTEL MANUFACTURER. ALL OTHER STRUCTURAL PRE -CAST COMPONENT <br />MANUFACTURERS MUST SUBMIT DESIGN LOAD INFORMATION TO ENGINEER OF RECORD FOR APPROVAL. ENGINEER OF RECORD RESERVES THE RIGHT <br />RE❑MAKE SPONSIBLIE FORNGES INSURINGER SUCH INFORMATION❑RREQUE❑STEDSBEEN AB❑VE HAS BEEN S❑UBMITTEDWT❑ EONGINEER❑R AS O� RECORD INTAC�❑MELYAM❑ANNER WHESHALL NEAVAILABLE, <br />CARPENTRY: <br />1. DIMENSIONED LUMBER SHALL BE DRESSED S4S, AND SHALL BEAR THE GRADE STAMP OF THE MANUFACTURER'S ASSOCIATION. <br />2. ALL LUMBER SHALL BE SOUND, SEASONED, AND FREE FROM WARP. <br />3. ALL STRUCTURAL BEAMS AND HEADERS SHALL BE SOUTHERN YELLOW PINE (SYP.) NO, 2 GRADE OR BETTER, <br />WITH SINGLE MEMBER (UNFACT❑RED) STRESSES AS FOLLOWS <br />Fv = 90 PSI <br />Fc = 975 PSI <br />E = 1,600,000 PSI <br />1% MAXIMUM MOISTURE CONTENT <br />FRAMING LUMBER SHALL BE #2 APRUCE-PINE-FUR OR BETTER. <br />INTERIOR NON -LOAD BEARING WALLS MAY BE UTILITY GRADE, <br />4. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. <br />5, PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH A CCA SALT TREATMENT IN ACCORDANCE WITH F,S, TT-W-571 <br />AND BEAR THE AMERICAN WOOD PRESERVERS INSTITUTE EQUALITY MARK LP-2. <br />6. SHEATHING FOR ROOFS AND WALLS SHALL BE APA RATED (EXPOSURE 1) SHEATHING WITH EXTERIOR GLUE, <br />ALL ROOF SHEATHING TO BE INSTALLED WITH PLYCLIPS, (MAXIMUM 24' O.C.) <br />7. NAILING FOR PLYWOOD ROOFS AND WALL SHEATHING SHALL BE 8d COMMONS @ 4' D.C. @ PANEL EDGES, AND 6" <br />O.C. INTERMEDIATE, FOR 1/2' SHEATHING OR LESS. NAILING FOR STRUCTURALLY APPROVED ARCHITECTURAL WALL PANELS (1/4"+) <br />SHALL BE 6d COMMON @ 4' D.C. AT PANEL EDGES, AND 6' D.C. INTERMEDIATE. <br />8, ALL FLO❑RING MATERIAL TO BE 3/4' T&G PLYWOOD, NAILED AND GLUED TO FLOOR J❑ISTS. FLOOR NAIL <br />WITH 10d NAILS AT 3' O.C. AT PANEL EDGES, 6' D.C. IN THE FIELD. STAGGER NAILS AT 2' O.C. AT BUTT ENDS OF PLYWOOD SHEATHING. <br />9. INSTALL BRIDGING IN ALL (2X) FLOOR OR ROOF J❑ISTS AT 8'-0' MAXIMUM. INSTALL BLOCKING IN ALL BEARING <br />WALLS AND PARTITIONS OVER 9'-0' @ MID -HEIGHT. BRACE GABLE END WALLS AT 4'-0' D.C. WHERE WALL FRAMING IS NOT <br />CONTINUOUS FROM FOUNDATION TO ROOF. <br />10. ALL NAILING AND BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION REQUIREMENTS. <br />ALL NAILS EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED. <br />11. ALL CONNECTION HARDWARE SHALL BE GALVANIZED AND SUPPLIED BY SIMPS❑N STR N TIE CO.❑R EQUIVA <br />LENT. SUBMIT CUT <br />SHEETS FOR ALL CONNECTION HARDWARE TO CONTRACTOR FOR APPROVAL. <br />ALL NAIL HOLES SHALL BE FILLED OR AS PRESCRIBED BY THE MANUFACTURER. <br />12. PROVIDE A SINGLE PLATE AT THE BOTTOM AND DOUBLE PLATE AT THE TOP OF ALL LOAD BEARING STUD WALLS, STAGGER END <br />JOINTS IN DOUBLE PLATES AT LEAST 4'-0'. 2X4 SILL PLATES FOR BEARING WALLS SHALL BE BOLTED TO FOUNDATION <br />AT A MAXIMUM OF 4'-0' O,C, <br />13.LOAD BEARING STUDS SHALL BE DOUBLED AT ALL ANGLES AND AROUND ALL OPENINGS, AND AT STRUCTURALLY APPROVED <br />ARCHITECTURAL WALL PANEL JOINTS. STUDS SHALL BE TRIPLED AT ALL CORNERS. <br />14. WOOD LINTELS OVER OPENINGS SHALL BE DOUBLED 2X12 HEADERS UNLESS NOTES OTHERWISE ON PLANS, WITH CONTINUOUS 3\4' PLYWOOD <br />FILLER CUT TO FULL DEPTH OF BEAM BETWEEN 2x MEMBERS, <br />15.RAFTER SCHEDULE FOR C❑NVENTI❑NAL FRAMED AREAS. <br />MAXIMUM <br />MEMBER SIZE SPAN (SYP #2) MAXIMUM <br />2 X 4 9 FT 6 FTSPAN (SYP #2) <br />2 X 8 12 FT 10 FT <br />2 X 10 14 FT 12 FT <br />2 X 12 16 FT 14 FT <br />NOTE 1 RAFTERS MUST BE BRACED LATERALLY BY A CONTINIOUS NAILING ❑F SHEATHING OR BRACED @ 24' ❑.C, WITH MINIMUM IX4. <br />NOTE 2: RAFTER SPACING NOT TO EXCEED 24' O.C. <br />NOTE 3: RIDGE BOARDS TO BE ONE SIZE LARGER THAN RAFTER UNLESS OTHERWISE NOTED ON PLANS. <br />NOTE 4: CONNECTOR SCHEDULE, <br />A. SIMPSON MTS20 (❑R EQUAL) BETWEEN CAT BLOCKING AND ROOF TRUSSES. <br />B. SIMPS❑N H5 (OR EQUAL) BETWEEN RAFTER TAILS TO CAT BLOCKING, <br />C. SIMPSON H5 (OR EQUAL) BETWEEN RAFTERS AND RIDGE BOARD. <br />D. SIMPS❑N CS20 AT ENDS OF RIDGE BOARD, OR SIMPSON JOINT HANGER WHERE APPLICABLE. <br />TIMBER MATERIALS: <br />ALL TIMBERS MATERIALS SHALL BE AS FOLLOWS: <br />LUMBER UTILIZED IN BOTTOM PLATE, TOP PLATES, POST, STUD PACKS AND BEAMS SHALL BE #2 YELLOW PINE (❑R BETTER). <br />EXTERIOR AND INTERIOR LOAD BEARING STUDS SHALL BE #2 SPRUCE (❑R BETTER), ALL OTHER STUDS SHALL BE "STUD GRADE' <br />SPRUCE SPACE 16" D.C.. ALL SPLICES AT TOP PLATE MUST BE MINIMUM 4'-0' AND NAILED 4" D.C. W/ 12d COMMON NAILS. <br />EXTERIOR WALLS SHALL BE CONSTRUCTED WITH 1/2' PLYWOOD ❑R 7/16' O.S.B. (2-M-W RATING) NAILED WITH 8d NAILS SPACED AT <br />3' O,C, ALONG ALL HORIZONTAL JOINTS AND EDGES, 6' ❑,C. ALONG ALL VERTICAL JOINTS AND EDGES AND 12' ❑.C. ALONG ALL INTERMEDIATE STUDS. <br />ALL OPENINGS 5'-0' WIDE OR LARGER STRAP HEADER BEAM TO THE HEADER STUDS WITH SIMPS❑N LSTA24 STRAP TIES AT EACH END <br />OF HEADER BEAM, ANCHOR BOTTOM OF HEADER STUDS TO FOUNDATION WITH SIMPSON HTT16 TENSION TIE, <br />INTERIOR STUD WALLS TO BE OF 2X4 #2 SPRUCE OR BETTER WITH SINGLE 2X4 P.T. PINE BOTTOM PLATE AND SINGLE 2X4 #2 SPRUCE TOP PLATE WITH <br />STUDS SPACED MAXIMUM 24' ❑.C. WALLS TO HAVE 1/2' GYPSUM BOARD EACH SIDE, WITH WALLS AT GARAGE TO HAVE MIN R-11 INSULATION. <br />ANCHOR WOOD SHEAR WALLS SEGMENTS TO FOUNDATION WITH SIMPSON LTT20B TENSION TIE AT EACH END OF WALL SEGMENTS AND AT ANY <br />WALL SEGMENT INTERSECTION (BUILDING CORNERS). <br />TRUSSES <br />2. THIS <br />LAYOUT DEFINES <br />ON PLANS ARE DSCHEMAPREFABRICATED, <br />IBC IONLY. TRUSS MANUFACT❑URERTANDD/IIR IENGI❑NEERAND <br />SHALL BE TRUSSES <br />EWFOR TRESSES <br />DESIGN AND SPACING OF ALL TRUSSES AND SHALL SUBMIT SHOP DRAWINGS TO THE BUILDER FOR APPROVAL, <br />3. THE WOOD TRUSS MANUFACTURER MUST PARTICIPATE IN A CODE APPROVED THIRD PARTY QUALITY ASSURANCE PROGRAM SUCH AS THE TRUSS PLATE <br />INSTITUTE'S "QUALITY CONTROL INSPECTION PROGRAM' OR EQUIVALENT. <br />4. WOOD TRUSS MEMBERS AND CONNECTORS SHALL BE DESIGNED FOR ALL LOADS LIVE, DEAD AND CONCENTRATED LOADS, <br />PLUS WIND LOADS IN ACCORDANCE WITH THE FBC SEC, 1606. <br />5.REFER TO THE FLOOR PLAN AND OTHER STRUCTURAL DETAIL SHEETS FOR IMPORTANT INFORMATION NOT SPECIFICALLY ADDRESSED BY THE <br />TRUSS FRAMING LAYOUT SUCH AS BEARING WALL HEIGHTS AND CEILING VAULT DETAILS. <br />6. W❑❑D TRUSS DESIGN SHOP DRAWINGS SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING INFORMATION: <br />A. SPAN LENGTH, OVERHANG AND EAVE DIMENSIONS, SLOPE AND SPACING OF WOOD TRUSSES. <br />B. ALL DESIGN LOADS AND THEIR POINTS OF APPLICATION, VALLEY AND CONVENTIONAL FRAMING MUST BE CONSIDERED. <br />C. ADJUSTMENTS TO ALLOWABLE VALUES. <br />D. REACTIVATE FORCES AND THEIR LOCATIONS. <br />E. BEARING TYPE AND MINIMUM BEARING LENGTH. <br />F. DEFLECTIONS <br />G. METAL CONNECTOR PLATE, TYPE, GAUGE, SIZE, AND L❑CATI❑N. <br />H. LUMBER SIZE, SPECIES, GRADE AND MOISTURE CONTENT, <br />I. L❑CATION AND CONNECTION DESIGN OF REQUIRED CONTINUOUS LATERAL BRACING, <br />J. NET UPLIFT LOADS BASED ON ACTUAL BUILDING DEAD LOAD. <br />K. WEB REINF❑RCEMENT DETAILS FOR GABLE END TRUSSES. <br />L. VALLEY SETS FOR OVER -BUILD CONDITIONS. <br />7, LIMIT DEFLECTIONS FOR LIVE LOAD TO SPAN/360 (ROOF), SPAN/460 (FLOOR), AND LIMIT TOTAL LOAD DEFLECTIONS TO <br />SPAN/240 (ROOF), SPAN/360 (FLOOR) UNLESS SPECIFICALLY NOTED OTHERWISE. <br />8. FIRE RETARDANT WOOD IS NOT ALLOWABLE FOR USE AS TRUSS CHORDS OR WEBS. <br />9,W❑❑D TRUSSES SHALL BE DESIGNED S❑ THAT MINIMAL HORIZ❑NTAL REACTIONS ARE IMPOSED ON THE SUPPORTING STRUCTURE UNDER <br />VERTICAL LOADS, NO SLIP CONNECTIONS ARE ALLOWED UNLESS OTHERWISE N❑TED, CONTACT CONTRACTOR AS REQUIRED. <br />W. WOOD TRUSSES MUST BE CHECKED FOR WIND. WIND VEL❑CITY, DESIGN VELOCITY PRESSURES, AND MEAN ROOF HEIGHT MUST BE <br />SHOWN ON THE SUBMITTED SHOP DRAWINGS. <br />11, CONTINUOUS BOTTOM CHORD LATERAL BRACING IS REQUIRED AT A MINIMUM SPACING OF 10' D.C. UNLESS NOTED OTHERWISE. <br />BOTTOM CHORD BRACING IS CONTINUOUS FROM ONE END OF THE BUILDING TO THE OTHER END. OVERLAP CONTINUOUS BRACING AT LEAST <br />ONE TRUSS SPACE, USE A MINIMUM OF 2 X 4 (ROOF), 2 X 6 (FLOOR) GRADE MARKED LUMBER AT LEAST 10' LONG, WITH <br />2- 16d NAILS AT INTERMEDIATE AND 3- 16d AT END CONNECTIONS. <br />12.CROSS BRACING IS REQUIRED AT MINIMUM 10' O,C, UNLESS NOTED OTHERWISE. LOCATE CROSS BRACING AT OR NEAR THE BOTTOM <br />CHORD BRACING. INSTALL CROSS BRACING AT EACH END AND AT 20' D.C. ALONG THE LENGTH OF THE LATERAL BRACING, CROSS BRACING IS ACCOMPLISHED <br />BY ATTACHING DIAGONAL WEB BRACING TO OPPOSITE SIDES OF THE SAME GROUP OF SIMILAR WEB MEMBERS, SLOPE CROSS BRACING IN OPPOSITE <br />DIRECTIONS AR APPROXIMATELY 45 DEGREES FORMING A CROSS "X'. USE A MINIMUM OF 2X4 GRADE MARKED LUMBER WITH AT LEAST 3- 16d NAILS <br />AT EACH CONNECTION, <br />13, TRUSS ERECTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING OF TRUSS SYSTEM DURING CONSTRUCTION. <br />14.HANDLING, INSTALLATION, AND BRACING OF WOOD TRUSSES SHALL BE IN ACCORDANCE WITH "HIB-91', PUBLISHED BY THE TRUSS PLATE INSTITUTE. <br />� id <br />1 (a 0 1 <br />GABLE ROOFS <br />10` < 0 < 45` <br />Q I� <br />d <br />10 < 0 S 30 <br />oJJJJJI�� <br />d O 0 La (311 0 13 d <br />HIP ROOFS NOTE: a = 4 Feet in at[ cases <br />a� �� �0,� �a� 10°< 0 S30° <br />GABLE ROOFS COMPONENT & CLADDING LOADING DIAGRAMS <br />10* < 0 < 45° <br />15.ALL WOOD TRUSSES SHALL BE FASTENED TO THEIR SUPPORTS WITH APPROVED HURRICANE ANCHORS, RATED TO CARRY UPLIFT LOADS <br />SPECIFIED BY TRUSS MANUFACTURER <br />16.ALL CONNECTION HARDWARE SHALL BE GALVANIZED AND SUPPLIED BY SIMPSON STRONG -TIE OR APPROVED EQUIVALENT MANUFACTURER. ALL <br />NAIL HOLES SHOULD BE FILLED, OR AS PRESCRIBED BY THE MANUFACTURER. <br />17,TRUSSES ARE TO BE DESIGNED TO ALLOW FOR THE PROPER ROUTING OF A/C DUCT WORK AND PLUMBING. <br />CHASES SHALL NOT BE BLOCKED BY WOOD TRUSSES, <br />18. PILING OF PLYWOOD ON WOOD TRUSSES IS NOT ALLOWED. <br />19.INSTALLATION OF BROKEN, DAMAGED, WARPED, OR IMPROPERLY REPAIRED WOOD TRUSSES IS NOT ALLOWED. <br />20.IMPORPER OR UNAUTHORIZED FIELD ALTERATIONS OF WOOD TRUSSES IS NOT ALLOWED. <br />21.GABLE ENDWALL TRUSSES MUST TRANSFER LATERAL LOADS TO THE SHEAR WALLS AND/OR THE ROOF DIAPHRAGM. <br />22.W❑❑D TRUSSES THAT D❑ NOT MEET INTERIOR LOAD BEARING WALLS MUST BE SHIMMED, DO NOT PULL WOOD TRUSSES DOWN TO INTERIOR BEARINGS, <br />23.SUBMITTALS: ALL SUBMITTALS SHALL BEAR THE EMBOSSED SEAL OF A LICENSED STRUCTURAL ENGINEER IN THE STATE OF FLORIDA AND SHALL BE <br />SUBMITTED TO CONTRACTOR/ENGINEER FOR REVIEW PRIOR TO WOOD TRUSS FABRICATION, <br />A, SUBMIT SEALED WOOD TRUSS DESIGN CALCULATIONS AND PROFILES FOR EACH TYPE OF TRUSS WITH PERMANENT BRIDGING REQUIREMENTS. <br />B. SUBMIT WOOD RUSS ERECTION PLAN, INCLUDING CONNECTIONS DEATILS AND UPLIFT ANCHORS. <br />C. SUBMIT WOOD TRUSS TEMPORARY ERECTION BRACING PLAN. <br />D. MAINTAIN COPY OF SUBMITTAL ON JOBSITE. <br />R❑❑FING (FIBERGLASS SHINGLES) <br />1. THE INSTALLATION OF FIBERGLASS SHINGLES SHALL COMPLY WITH THE PROVISIONS OF FRC R905. <br />2. FIBERGLASS SHINGLES SHALL BE FASTENED TO SOLIDLY SHEATHED DECKS, <br />3. UNLESS OTHERIWSE NOTED, REQUIRED UNDERLAYMENT SHALL CONFORM WITH ASTM D 226 TYPE I, OR ASTM D 4869 TYPE 1. <br />4. SELF -ADHERING POLYMER MODIFIED BITUMEN SHEET, SELF -ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL C❑M�LY <br />WITH ASTM D 1970. <br />5. FIBERGLASS SHINGLES SHALL HAVE SELF -SEAL STRIPS OR BE INTERLOCKING, AND COMPLY WITH ASTM D 225 OR ASTM D 3462. <br />6. FASTENERS FOR FIBERGLASS SHINGLES SHALL BE GALVANIZED, STAINLESS STEEL, ALUMINUM OR COOPER ROOFING NAILS. <br />MINIMUM 12 GAUGE (0.105 INCH) SHANK WITH A MINIMUM 3/8 INCH DIAMETER HEAD OF A LENGTH TO PENETRATE THROUGH <br />THE ROOFING MATERIALS AND A MINIMUM OF 3/4 INCH INTO THE ROOF SHEATHING. THE CORROSION RESISTANCE OF NAILS <br />NAILS AND SCREWS SHALL MEET ASTM A641, CLASS I OR EQUAL, THE CORROSION RESISTANCE OF CLIPS SHALL MEET ASTM A153, <br />WHERE THE ROOF SHEATHING IS LESS THAN 3/4 INCH THICK, THE NAILS SHALL PENETRATE THROUGH THE SHEATHING. <br />7,FLASHING MADE FROM METAL SHALL BE CORROSION RESISTANT AND SHALL BE NOT LESS THAN 26 GAGE. <br />& FIBERGLASS SHINGLES SHALL BE SECURED TO THE ROOF WITH NOT LESS THAN FOUR FASTENERS PER STRIP SHINGLE OR TWO <br />FASTENERS PER INDIVIDUAL SHINGLE, UNLESS OTHERWISE NOTED, ATTACHMENT OF FIBERGLASS SHINGLES SHALL <br />CONFORM WITH ASTM D 3161 (MODIFIED TO 110 MPH) OR M-DC PA 107-95, <br />PROTECTION AGAINST TERMITES <br />R320,1 <br />Termite protection shall be provided by registered termiticides, including soil applied pesticides, baiting systems, and <br />pesticides applied to wood, or other approved methods of termite protection [abeled for use as a preventative treatment <br />to new construction (see Section 202, Registered Termiticide), Upon completion of the application of the termite protective <br />treatment, a certificate of compliance shall be issued to the buitolinQ department by the licensed pest control company <br />contains the following statement: 'The building has received a complete treatment for the prevention of subterranean <br />termites, Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and <br />Consumer Services.' <br />R320.1.1 <br />If soil treatment used for subterranean termite prevention, the initial chemical soil treatment inside the foundation <br />perimeter shall be done after all excavation, backfiRing and compaction is complete. <br />R320.1.2 <br />If soil treatment is used for subterranean termite prevention, soil area disturbed after initial chemical soil treatment shall <br />be retreated with a chemical soil treatment, including spaces boxed or formed. <br />R320.1.3 <br />If soil treatment is used for subterranean termite prevention, space in concrete floors boxed out or formed for the <br />subsequent installation of plumbing traps, drains or any other purpose shall be created by using plastic or metal <br />permanently placed forms of suf Fiicient depth to eliminate any planned soil disturbance after initial chemical soil treatment, <br />R320.1.4 <br />If soil treatment is used for subterranean termite prevention, chemically treated soil shall be protected with a minimum <br />6 mil vapor retarder to protect against rainfall dilution, If rainfall occurs before vapor retarder placement, retreatment <br />is required. Any work, including placement of reinforcing steel, done after chemical treatment until the concrete floor <br />is ppoured, shall be done in such manner as to avoid penetrating or disturbing treated soil. <br />R320.1.5 <br />If soil treatment is used for subterranean termite prevention, concrete overpour or mortar accumulated along the <br />exterior foundation perimeter shall be removed prior to exterior chemical soil treatment, to enhance vertical penetration <br />of the chemicals. <br />R320.1.6 <br />If soil treatment is used for subterranean termiterevention, chemical soil treatments shall also be applied under all <br />exterior concrete or grade within 1 foot (305 mm) op the primary structure sidewalls. Also, a vertical chemical barrier <br />shall be applied promptly after construction is completed, inctudingg initial landscaping and irrigation/sprinkler installation, <br />Anyy soil disturbed after the chemical vertical barrier is applied Nall be promptly retreated. <br />R320,1.7 <br />If a registered termiticide formulated and registered as a bait system is used for subterranean termite prevention, <br />Sections R32011 through R32016 do not apply; however, a signed contract assuring the installation, maintenance and <br />monitoring of the baiting system for a minimum of five ears from the issue of the certificate of occupancy shall be <br />provided to the building official prior to the pouring o . the slab, and the system must be installed prior to final building <br />approval. If the baiting system directions for use require a monitoring phase prior to installation of the pesticide active <br />ingredient, the installation of the monitoring phase components shall be deemed to constitute installation of the system. <br />GLAZING SECTION R308 <br />R308.1 Identification, <br />Except as indicated in Section R30811 , each pane of glazing installed in hazardous locations as defined in <br />Section R308.4 shall be provided with a manufacturer?s or installer?s label, designating the type and <br />thickness of glass and the safety glazing standard with which it complies, which is vislbte in the final <br />installation. The label shall be acid etched sandblasted, ceramic -fired, embossed mark, or shall be of a <br />type which once applied cannot be removed without being destroyed. <br />Exceptions: <br />1. For other than tempered glass, labels may be omitted provided the building official approves the use <br />of a certificate, affidavit or other evidence confirming compliance with this code, <br />2. Tempered spandrel glass may be identified by the manufacturer with a removable paper label. <br />R308.1.1 Identification of multipane assemblies. <br />Multi -pane assemblies having individual panes not exceeding 1 square foot (0.09 m 2 ) in exposed area shall <br />have at least one pane in the assembly identified in accordance with Section R308.1 All other panes in the <br />assembly shall be labeled ?16 CFR 1201.? <br />R308.2 Louvered windows or Jalousies. <br />Regular, float, wired or patterned glass in jalousies and louvered windows shall be no thinner than nominal <br />3 / 16 inch (4,76 mm) and no longer than 48 inches (1219 mm). Exposed glass edges shall be smooth. <br />R308.2,1 Wired glass prohibited, <br />Wired glass with wire exposed on longitudinal edges shall not be used in jalousies or louvered windows. <br />R308.3 -Human impact loads. <br />Individual ggLazed areas includin glass mirrors in hazardous locations such as those indicated as defined in <br />Section R308,4 shall pass the est requirements of CPSC 16 CFR, Part 1201. Glazing shall comply with the <br />CPSC 16 CFR, Part 1201 criteria for Category I or Category II as indicated in Table R308.3 <br />Exceptions: <br />1, Polished wired glass for use in fire doors and other fire resistant locations shall comply with <br />ANSI Z97.1. <br />2. Louvered windows and jalousies shall comply with Section R308.2 <br />CONTRACTOR IS TO VERIFY ANY STRUCTURAL <br />OR CODE REQUIREMENTS PRIOR TO CONSTRUCTION, AND TO BUILD ACCORDINGLY, <br />CONTRACTOR TO VERIFY DIMENSIONING PRIOR TO CONSTRUCTION AND TO <br />NOTIFY OWNER & ENGINEER FOR ANY DIMENTI❑NAL CORRECTIONS PRIOR <br />TO CONSTRUCTION. <br />3�(P `ir f l/jt°a <br />0_6.7 3�3 INDEX OF DRAWINGS 0� <br />/11 '� �IJ 4 , 1 COVER <br />q (0�5u;lGl�n 2 FLOOR PLAN FOUNDATION PLAN <br />c 3 ELECTRICAL & HV �_ <br />�je f l �EVIEW DATE_ �� 2-y %v 0 <br />S 4 LINTEL <br />h�-Mti°inj �t�1 5 TRUSS CITY OF ZEPHYRHILL <br />6 ELEVATIONS, DETARV�4S EXAMINER <br />7 SPECS <br />SUBMITTAL DATA , z� <br />PARCEL:13-26-21-0140-00000-0380 <br />I hereby certify that I have reviewed this plan and Pound it to <br />be in compliance with ASCE 7 and the Florida Building Code 2007 edition, <br />with 2009 supplement, <br />David W, Smith, P.E. #53608 ENGINEER LICENCE #53608 <br />BENJAMIN RODRIGUEZ <br />39645 MEADOWOOD LOOP <br />ZEPHYRHILLS, EL 33542 <br />D.W. SMITH ,M.S.,P.E.#53608 <br />FLORIDA PROFESSI❑NAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE-DADE CITY,FL❑RIDA 33525 <br />PHONE:352-521-0865 FAX:352-521-0867 E-MAIL: dwsflpe@earthlink.net <br />ENGINEER'S NOTES SHEET OF <br />1 OF 7 <br />SCALE DATE JOB NO. <br />11 MAR 2010 <br />DESIGN/DRAWN CHECKED 2010-1 2 <br />R. GOLLHARDT D.W.S. <br />