Laserfiche WebLink
DESIGN CRITERIA NOTES: <br />1. THE INTENDED DESIGN STANDARDS AND/OR CRITERIA ARE AS FOLLOWS: <br />GENERAL FLORIDA BUILDING CODE 2017 (SIXTH EDITION). <br />2017 CODE CYCLE, NEC 2014 AND FIRE CODES. <br />6TH EDITION FLORIDA FIRE PREVENTION CODE, 2015 NFPA 1, 2015 <br />NFPA 101, 2013 NFPA 13,134,13D, 2013 NFPA72, NFPA 70. <br />ANSUAF&PA - WFCM SBCCI - SSTD - 10 <br />FC&PA - GUIDE TO CONCRETE MASONRY CONSTRUCTION IN HIGH <br />WIND AREAS <br />CONCRETE AC1318 <br />MASONRY ACI 530 <br />STRUCTURAL STEEL AISC <br />WOOD NDS <br />WOOD TRUSSES ANSI/TPI <br />FOUNDATION OWNER SOIL INVESTIGATION REPORT ASSUMED MINIMUM <br />SOIL BEARING PRESSURE 2,000 P.S.F. <br />2. DESIGN GRAVITY LIVE LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS: <br />ROOF 20 PSF <br />ATTIC 10 PSF <br />ATTIC WITH STORAGE 30 PSF <br />3. DESIGN GRAVITY DEAD LOADS ARE THE ACTUAL WEIGHT OF ALL COMPONENTS. <br />4. OCCUPANCY: MODERATE -HAZARD FACTORY INDUSTRIAL GROUP F-1. <br />5. TYPE OF CONSTRUCTION = III-B <br />DESIGN WIND CRITERIA: <br />1. DESIGN WIND LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE BASED ON THE <br />FLORIDA BUILDING CODE 2017 (SIXTH EDITION). <br />WIND SPEED - 145 MPH <br />BUILDING CATEGORY 11 / IMPORTANCE FACTOR = 1.00 / EXPOSURE B <br />INTERNAL PRESSURE COEFFICIENT: ENCLOSED BUILDING = (+/_) 0.18 <br />WINDOW AND DOOR ASSEMBLY CRITERIA: <br />1. ALL DOORS AND WINDOWS MUST BE DESIGNED BY THE MANUFACTURER TO MEET THE <br />FBC AND MUST INCLUDE LABELING (AAMA OR WDMA). <br />ALL DOORS AND WINDOWS SHALL BE ATTACHED TO THE BUCK STRIPS OR WOOD FRAMING <br />PER THE MANUFACTURER'S DESIGN ANCHOR SIZES AND CLADDING WIND PRESSURES TABLE <br />BELOW. <br />SEE JAMB DETAIL BELOW FOR BUCK STRIP ATTACHMENTS TO MASONRY IF APPLICABLE. <br />ROOF ASSEMBLIE <br />1. ALL ROOF ASSEMBLIES MUST MEET THE FBC WIND RESISTANT RATINGS FOR THE <br />SPECIFIED WIND LOADING. <br />2. THE ROOFING MANUFACTURER SHALL SUBMIT ALL NECESSARY DOCUMENTS VERIFYING <br />COMPLIANT FBC WIND RESISTANT RATINGS FOR ROOF FASTENERS, UNDERLAYMENT AND <br />FLASHING. <br />GENERAL STRUCTURAL NOTES <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY <br />PRECAUTIONS AND REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT ADVISE <br />OR NOR ISSUE DIRECTION AS TO SAAFETY PRECAUTIONS AND PROGRAMS. <br />2. THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR <br />SHALL PROVIDE ALL TEMPORARY BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE <br />IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN <br />COMPLETED. THE DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, <br />SHORING, TEMPORARY SUPPORT, ETC., ARE THE SOLE RESPONSIBILITY OF THE <br />CONTRACTOR. <br />3. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES AND <br />SEQUENCES OR PROCEDURES TO PERFORM THE WORK. THE SUPERVISION OF THE WORK IS <br />THE SOLE RESPONSIBILITY OF THE CONTRACTOR. <br />4. LOADING APPLIED TO THE STRUCTURE DURING THE PROCESS OF CONSTRUCTION SHALL <br />NOT EXCEED THE SAFE LOAD -CARRYING CAPACITY OF THE STRUCTURAL MEMBERS. <br />5. THE ARCHITECT IS RESPONSIBLE FOR THE STRUCTURAL COMPONENTS OF THE BUILDING <br />AND THEIR CONNECTIONS ONLY. HE IS NOT RESPONSIBLE FOR THE SELECTION OF <br />MATERIALS, FLASHING, PAINTING, WATERPROOFING, ELECTRICAL, MECHANICAL, ETC. <br />FOUNDATION NOTES: <br />1. THE OWNER SHALL EMPLY A GEOTECHNICAL ENGINEER TO EVALUATE THE BUILDING SITE, <br />PROPOSED FILL MATERIAL AND TO VERIFY THAT THE ASSUMED BEARING CAPACITY OF 2,000 <br />P.S.F. IS OBTAINABLE. <br />2. IT IS THE CONTRACTORS RESPONSABILITY TO OBTAIN A COPY OF THE GEOTECHNICAL <br />REPORT FOR BIDDING PURPOSES RELATING TO SUBGRADE PREPARATION, FILL MATERIAL, <br />PROOFROLLING, AND TESTING REQUIREMENTS. <br />3. THE BUILDING SITE SHOULD BE STRIPPED AND CLEARED OF ALL SURFACE VEGETATION <br />AND ORGANIC MATERIALS, THE CONTRACTOR IS TO NOTIRY THE ARCHITECT/ENGINEER IF <br />SOIL CONDITIONS ARE UNCOVERED THAT PREVENT THE REQUIRED SOIL BEARING <br />PRESSURE FROM BEING OBTAINED. <br />4. ALL FOOTINGS HAVE BEEN DESIGNED BASED UPON AN ASSUMED SOIL BEARING <br />PRESSURE OF 2,000 PSF. ALL FOOTINGS SHALL BEAR ON UNDISTURBED, FIRM NATURAL SOIL <br />OR COMPACTED FILL. ALL BEARING SURFACES (FOOTINGS & SOG) ARE TO BE EVALUATED <br />BY A GEOTECHNICAL ENGINEER / TESTING LAB PRIOR TO POURING CONCRETE, SUBGRADE <br />SOILS SHALL BE COMPACTED TO A DENSITY OF 95% BASED ON THE MODIFIED PROCTOR <br />DENSITY. <br />5. HORIZONTAL CONSTRUCTION JOINTS IN FOOTINGS WILL NOT BE PERMITTED. WHERE <br />VERTICAL CONSTRUCTION JOINTS OCCUR IN CONTINUOUS FOOTINGS, PROVIDE A <br />CONTINUOUS 2"X4" KEYWAY. <br />6. NO UNBALANCED BACKFILLING SHALL BE DONE AGAINST FOUNDATION WALLS UNLESS <br />WALLS ARE SECURELY BRACED AGAINST OVERTURNING. EITHER BY TEMPORARY <br />BRACING OR BY PERMANENT CONSTRUCTION. <br />PLYWOOD/ GYPBOARD SHEATHING NOTES: <br />1. ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN <br />PLYWOOD ASSOCIATION (APA) SPECIFITACIONS. <br />2. ALL ROOF PANEL SHEATHING SHALL BE 16/32" (1/2" NOM) EXPOSURE - 1 APA RATED <br />SHEATHING. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY USE OF PANEL CLIPS OF <br />BLOCKING BETWEEN FRAMING. SEE NAILING SCHEDULE, IF NOT SPECIFIED, CONNECT ROOF <br />SHEATHING WITH 10 d RING SHANK NAIL AT 4" O/C AT SUPPORTED PANEL EDGES AND 4" O/C/ <br />AT INTERMEDIATE SUPPORTS. <br />3. INSTALL ALL PLYWOOD SHEATHING WITH THE LONG DIMENSION OF THE PANEL <br />PERPENDICULAR TO THE SUPPORTS AND WITH PANELS CONTINUOUS OVER TWO OR MORE <br />SPANS, STAGGER PANEL END JOINTS, ALLOW 1/8" SPACES AT ALL FLOOR, ROOF AND WALL <br />PANEL EDS AND EDGES. <br />4. ALL NAILING SHALL BE CAREFULLY DRIVEN AND NOT OVERDRIVEN. THE USE OF STAPLES <br />ARE PROHIBITED FROM USE. <br />Data Area Building <br />NUMBER NAME AREA <br />1 <br />Existing Work Area <br />9,147 SF <br />2 <br />New Office Area <br />880 SF <br />3 <br />Existing Office <br />Area <br />2,560 SF <br />Total Area: 3 <br />12,587 SF <br />CAST -IN -PLACE CONCRETE NOTES: <br />1. CONCRETE MIXES SHALL BE DESIGNED PER ACI 301, USING PORTLAND CEMENT <br />CONFORMIN TO ASTM C-150, AGGREGATE CONFORMING TO ASTM C-33. CONCRETE SHALL BE <br />READY -MIXED IN ACCORDANCE WITH ASTM C-94. <br />2. CONCRETE SHALL CONFORM TO THE FOLLOWING COMPRESSIVE STRENGTH AND SLUMP. <br />CONCRETE MIN. F'C (28 DAYS) SLUMP AGG SIZE <br />SLAB ON GRADE 3,000 P.S.I. 3" TO 5" # 57 <br />FOUNDATIONS 3,000 P.S.I. 3" TO 5" # 57 <br />RETAINING WALLS 4,000 P.S.I. 3" TO 5" # 57 <br />GROUTED CELL 2,500 P.S.1. 8" TO 1 V # 89 (3/8") <br />3. ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 301. <br />SPECIFICATION FOR STRUCTURAL CONCRETE BUILDINGS. <br />4. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60. <br />5. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A-185 (FLAT SHEETS ONLY). <br />6. AL REINFORCING STEEL SHALL BE SET AND TIED IN PLACE PRIOR TO PORING OF <br />CONCRETE, EXCEPT THAT VERTICAL DOWELS FOR MASONRY WALL REINFORCING MAY BE <br />"FLOATED" IN PLACE. <br />7. REINFORCING STEEL, INCLUDING HOOKS AND BENDS, SHALL BE DETAILED IN <br />ACCORDANCE WITH ACI 315. ALL REINFORCING STEEL INDICATED AS BEING CONTINUOUS <br />(CONT) SHALL BE LAPPED (#5 = 30"). <br />8. UNLESS OTHERWISE NOTED, THE FOLLOWING MINIMUM CONCRETE COER SHALL BE <br />PROVIDED FOR REINFORCEMENT: <br />A) CONCRETE EXPOSED TO EARTH (FOOTINGS) = 3" <br />B) SLAB ON GRADE (WIRE MESH = 1 1/2" TOP & BOTTOM. <br />C) CONCRETE NOT EXPOSED TO EARTH O WEATHER = 1 1/2". <br />9. WHERE REINFORCEMENT OR ANCHOR BOLTS ARE MISPLACED, A DRILLED AND EPDXY <br />SYSTEM MAY BE USED WITH ENGINEERS APPROVAL: USE A TWO COMPONENT EPDXY <br />SYSTEM MEETING ASTM C881 HILTI HY 15D/SIMPSON-SET/ALLIED A-100/ULTRA BOND/ OR <br />EQUAL. <br />HOLE DIAMETER = BAR/ANCHOR DIAMETER + 1/8" <br />HOLE DEPTH = 15 X BAR/ANCHOR DIAMETER <br />FOLLOW MANUFACTURERS INSTALLATION PROCEDURES, I.E. BLOW OUT HOLES WITH <br />COMPRESSED AIR AND BRUSH CLEAN. <br />SLAB ON GRADE NOT <br />1. PROVIDE 4" CONCRETE SLABS REINFORCED WITH 6X6-W2.9 X 2W.9 CHAIRED AT 3FT O/C. <br />OVER 10 MILL POLYETHYLENE VAPOR BARRIER MEETING ASTM E 1745 CLASSES A,B,&C, <br />OVERLAP 6" WITH 4" COMPATIBLE TAPE. <br />2. REFER TO GEOTECHNICAL REPORT FOR PREPARATION OF SITE. AS A MINIMUM THE <br />FOLLOWING SHOULD BE PERFORMED. REFER TO GEOTECHINICAL REPORT FOR PROOF - <br />ROLLING REQUIREMENTS IF ANY. <br />A. CLEAR AND STRIP ALL TOPSOILS OF VEGETATION AND ORGANIC MATERIALS. <br />B. COMPACT SUBGRADE TO MEET 95% DENSITY. <br />C. ALL FILL MATERIAL SHALL BE CLEAN APPROVED ENGINEERED FILL COMPACTED IN 12" <br />LIFT TO MEET 95% DENSITY BASED ON THE MODIFIED PROCTOR TEST. <br />D. ALL TRENCHES AND DISTURBED SOILS SHALL BE RE -COMPACTED AND TESTED. <br />E. TREAT ALL SOILS FOR TERMITES. <br />3. ALL WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A-185. (FLAT SHEETS <br />ONLY) LAP ADJOINING PIECES AT LEATS ONE FULL MESH. <br />4. UNLESS OTHERWISE APPROVED, ALL WELDED WIRE FABRIC SHALL BE CHAIRED INTO <br />POSITION INDICATED. <br />5. ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENT OF ACI 301, <br />"SPECIFICATION FOR STRUCTURAL CONCRETE BUILDINGS". "GUIDE FOR CONCRETE FLOOR <br />AND SLAB CONSTRUCTION" ACI 301. HOT WEATHER CONCRETING SHALL BE IN ACCORDANCE <br />W/ACI 305. <br />6. SEE THE ARCHITECTURA DRAWINGS FOR EXACT LOCATION OF DEPRESSED SLAB AREAS, <br />SLOPES AND DRAINS. SLOPE SLAB TO DRAINS WHERE SHOWN. <br />7. ALL SLAB ARE TO HAVE SAW CUT CONTROL JOINTS AT 12FT ON CNETER, SEE DETAIL. ALL <br />SLABS ARE TO E CURED WITH A DISSIPATING MEMBRANE -FORMING CURING COMPOUND. <br />MASONRY NOTES <br />1. MASONRY CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE <br />"SPECIFITACIONS FOR MASONRY STRUCTURES (ACI 530.1) PUBLISHED BY THE AMERICAN <br />CONCRETE INSTITUTE. <br />2. HOLLOW LOAD -BEARING MASONRY UNITS SHALL CONFORM TO ASTM C-90, AND BE MADE <br />WITH NORMAL WEIGHT AGGREGATE. THE MINMUM NET AREA COMPRESSIVE STRENGTH <br />SHALL BE (fm) = 1,500 PSI AT AN AGE OF 28 DAYS, AS DETERMINED BY THE UNIT STRENGTH <br />METHOD OF ACI 530.1. <br />3. FILL ALL BOND BEAMS AND REINFORCED CELLS SOLIDLY WITH GROUT, GROUT SHALL <br />CONFORM TO ASTM C476 AND SHALL OBTAIN A MIN. 28 DAY COMPRESSIVE STRENGTH OF (fc) <br />2,500 PSI, 8 TO 11" SLUMP, MAXIMUM AGGREGATE SIZE - 3/8", TESTED PER ASTM C-1019 EACH <br />5,000 SF. PROVIDE CLEANOUTS / OBSERVATION HOLES FOR ALL VERTICAL REINFORCEMENT. <br />VIBRATE ALL GROUT POURS WITH MECH VIBRATOR OR SELF -CONSOLIDATING GROUT (SCG) <br />MAY BE USED WITH A SPREAD OF 22" TO 30". <br />4. REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ASTM A-615, GRADE 60. PROVIDE A <br />MINIMUM LAP # 5 = 30". #6 = 36" AT ALL SPLICES, UNLESS INDICATED OTHERWISE. <br />5. MORTAR SHALL CONFORM TO ASTM C-270, TYPE S. ALL MORTAR SHALL MEET THE <br />"PROPORTION SPECIFICATIONS" OF ASTM C-270 AND BE MADE WITH PORTLAND CEMENT/LIME. <br />6. UNLESS OTHERWISE INDICATED, ALL WALLS SHALL BE LAID IN RUNNING BOD. BOND <br />CORNES AND INTERSECTIONS OF ALL LOAD -BEARING WALLS. <br />7. PROVIDE VERTICAL REINFORCING AS SHOWN ON PLAN. PROVIDE BARS AT ALL WALL <br />CORNERS, INTERSECTIONS AND EACH SIDE OF ALL OPENINGS. TWO #5 EACH SIDE OF <br />OPENINGS GREATER THAN 6 FT, USE STD HOOKS INTO BOND BEAMS. <br />8. PROVIDE REBAR DOWELS FROM FOUNDATIONS TO MATCH VERTICAL REINFORCING SIZE <br />AND SPACING. DOWELS SHALL HAVE STANDARD 90 DEGREE HOOKS AND LAP WITH THE FIRST <br />LIFT OF REINFORCING. <br />9. PROVIDE STANDARD LADDER TYPE 9 GAUGE HORIZONTAL JOINT REINFORCING AT 16" ON <br />CENTER IN ALL WALLS, HOT DIPPED GALVANIZED PER ASTM A153. COORDINATE BRICK TIE <br />BACK REQUIREMENT, IF ANY WITH THE ARCHITECTURAL DRAWINGS. <br />10 PROVIDE PRECAST LINTELS ABOVE ALL WALL OPENINGS AS INDICATED IN LINTEL <br />SCHEDULE. SEE THE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL DOOR AND <br />WINDOW OPENINGS. <br />WOOD FRAMING NOTES <br />1. DIMENSIONED LUMBER SHALL BE DRESSED S4S, AND SHALL BEAR THE GRADE STAMP OF THE <br />MANUFACTURE'S ASSOCIATION. <br />2. ALL LUMBER SHALL BE SOUND, SEASONED, AND FREE FROM WARP. <br />3. LUMBER GRADES OR BETTER, SITH SINGLE MEMBER (UNFACTORED) STRESSES AS FOLLOWS: <br />Fv = 90 PSI <br />Fc = 1,450 PSI <br />E = 1,600,000 PSI. <br />19% MAXIMUM MOISTURE CONTENT. <br />4. ALL FRAMING LUMBER SHALL BE # 2 SPRUCE -PINE -FIR OR BETTER U.N.O. <br />5. INTERIOR LOAD BEARING (IF APPLICABLE) WALL STUDS SPACED AT 16" O.C. AND LESS THAN 8'4" IN <br />HEIGHT SHALL BE STUD GRADE, SPRUCE -PINE -FIR OR BETTER. <br />6. INTERIOR NON -LOAD BEARING WALLS SHALL BE UTILITY GRADE OR BETTER. STUDS SHALL BE AT 16" O.C. <br />WITH P.T. BOTTOM PLATE. <br />7. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. <br />8. PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH A CCA SALT TREATMENT IN ACCORDANCE <br />WITH F.S. 11-W-571 AND BEAR THE AMERICAN WOOD PRESERVES INSTITUTE EQUALITY MARK LP-2. <br />9. PLYWOOD FOR ROOF AND WALLS SHALL BE 7/16' (MIN) APA RATED SHEATHING EXTERIOR GLUE. ALL <br />ROOF SHEATHING TO INSTALLED WITH PLYWOOD CLIPS (MAXIMUM 24" O.C.) SEE PLANS FOR SHEATHING <br />THICKNESS). <br />10. ROOF SHEATHING SHALL BE NAILED WITH 8d COMMONS @ 4" O.C. AT EDGES AND 12" O.C. INTERMEDIATE. <br />11. WALL SHEATHING SHALL BE NAILED WITH 8d COMMONS @ 4" O.C. AT EDGE AND 12" O.C. INTERMEDIATE <br />HARDBOARD LAP SIDING OVER SHEATHING NAILED SHALL BE 10d GALV. WITH MIN. HEAD DIA. OF 0.240 INCH <br />STAGGERED @ 16" O.C. TOP AND BOTTOM. <br />12. INSTALL BLOCKING IN ALL WALL STUDS OVER 8'-0" @ MID -HEIGHT, AND SHEATHING JOINT. BRACE GABLE <br />END WALL AT 4'-0" O.C. WHERE WALL FRAMING IS NOT CONTINUOUS FORM FOUNDATION TO ROOF, OR AS <br />SHOWN ON DRAWINGS. <br />13. ALL NAILING AND BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION <br />REQUIREMENTS ALL NAILS EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED. <br />14. ALL CONNECTION HARDAWARE SHALL BE GALVANIZED AND SUPPLIED BY SIMPSON STRONG TIE CO., <br />HUGHES MANUFACTURING OR EQUIVALENT. SUBMIT CUT SHEETS FOR ALL CONNECTION HARDWARE TO <br />ENGINEER FOR APPROVAL. ALL NAIL HOLES SHALL BE FILLED OR AS PRESCRIBED BY THE MANUFACTURER. <br />PRE-ENGINEERED WOOD TRUSS NOTES: <br />1. WOOD TRUSS SYSTEMS SHALL BE DESIGNED BY THE MANUFACTURER TO SUPPORT THE FOLLOWING <br />LOADS. <br />A. ROOF TRUSS GRAVITY LOADING CASE <br />TOP CHORD LOADING <br />LIVE LOAD 20 PSF <br />DEAD LOAD - ASPHALT SHINGLES 10 PSF <br />TILE ROOF 20 PSF <br />BOTTOM CHORD LOADING <br />ATTIC LIVE LOAD 10 PSF <br />ATTIC LIVE LOAD WITH STORAGE - 30 PSF <br />DEAD LOAD 10 PSF <br />LIVE LOAD DEFLECTION LIMITED TO = U240 <br />B. ROOF TRUSS WIND LOADING CASE <br />TRUSSES ARE TO BE DESIGNED FOR THE WIND LOADING SHOWN IN "DESIGN <br />WIND CRITERIA" NOTES. SEE PLANS FOR OVERHANGS, OPEN AND PARTIALLY <br />ENCLOSED AREAS. IF TRUSSES ARE TO HAVE APPLIED OVERHANG PT TAILS, <br />THE TRUSS ENGINEERING SHOULD BE RUN WITH THE SPECIFIED OVERHANG SO <br />ACCURATE UPLIFT LOAD ARE SHOWN IN THE ABSENCE OF DRYWALL CEILINGS <br />PROVIDE BOTTOM CHORD BRACING AS DESIGNED BY MANUFACTURER. <br />2. WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH THE <br />APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE "NDS" NATIONAL DESIGN PECIFICATIONS FOR <br />WOOD CONSTRUCTION ANSUAF&PA AND THE NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED <br />WOOD TRUSS CONSTRUCTION "ANSI/TPI". <br />3. WOOD MATERIALS SHALL BE SOUTHERN PINE, DOUGLAS FIR OR LARCH AND SHALL BE KILN DIRED AND <br />USED AT 19% MAXIMUM MOISTURE CONTENT. PROVIDE GRADE No. 2 OR BETTER REQUIRED TO SATISFY <br />STRESS REQUIREMENTS. <br />4. CONNECTOR PLATES SHALL BE NOT LESS THAN 0.036 INCHES (20 GAUGE) IN COATED THICKNESS, SHALL <br />MEET OR EXCEED ASTM A653 GRADE 33 OR HIGHER AND SHALL BE HOT DIPPED GALVANIZED ACCORDING TO <br />ASTM A-525 (COATING G60). <br />5. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY AND PERMANENT BRACING AS REQUIRED FOR SAFE <br />ERECTION AND PERFORMANCE OF THE TRUSSES. THE GUIDELINES SET FORTH BY THE TRUSS PLATE <br />INSTITUTE PUBLICATION "HIB-91, COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND <br />BRACING METAL PLATE CONNECTED WOOD TRUSSES" SHALL BE A MINIMUM REQUIREMENT. <br />6. ROOF TRUSSES SHALL MATCH THE EXISTING ROOF SLOPE AND THE EXISTING ROOF OVERHANG. IT IS <br />CONTRACTOR RESPONSABILITY TO VERIFY EXISTING SLOPE AND EXISTING OVERHANG. <br />MASONRY BOND BEAM <br />8" X 8" WITH 1 # 5 CONTINUOUS <br />FILLED W/3000 P.S.I. CONCRETE <br />VERTICAL REBAR #5 REINFORCEMENT <br />IS TO HAVE A STANDARD HOOK INTO <br />THE UPPER MOST BOND -BEAM <br />PLACE METAL LATH OR WIRE <br />SCREEN OVER CORES NOT TO BE <br />FILLED (FELT PAPER PROHIBITED) <br />9 GA HOT -DIPPED GALVANIZED HORIZONTAL <br />JOINT REINFORCING AT 16" O.C. STARTING AT <br />FIRST COURSE ABOVE FOUNDATION. <br />LAP SPLICES 6", USE PREFAB L'S AND T'S AT <br />WALL INTERSECTIONS (TRUSS TIES OR LADDER <br />TIES). <br />1#5 VERTICAL REINFORCING IN GROUT FILLED <br />CORES WITH 2,500 P.S.I CONCRETE FROM <br />FOOTING TO BOND BEAM. SEE FOUNDATION <br />PLAN FOR LOCATION. <br />ALL CELLS BELOW SLAB SOLID <br />SHALL BE GROUTED WITH 3,000 <br />P.S.I. CONCRETE. <br />SET FIRST BLOCK COURSE <br />IN FULL MORTAR BEDDING. <br />SEE PLANS AND SECTIONS FOR <br />FOOTING SIZE, REINFORCEMENT <br />AND <br />DEPTH BELOW GRADE. <br />0 <br />ISO <br />8"X8"X16" CONCRETE BLOCK WALL LAID IN <br />RUNNING BOND WITH TYPE S MORTAR (1,800 <br />P.S.I.). <br />25" MINIMUN LAP FOR # 5 REBAR <br />PROVIDE 4"X4" INSPECTION <br />OPENING <br />AT EACH FILLED CELL TYPICAL. <br />VERTICAL DOWEL #5 REBAR <br />SEE FOUNDATION PLAN FOR <br />LOCATION <br />O <br />H <br />a_ <br />U) <br />Z <br />0 <br />U <br />U) <br />W <br />> <br />o <br />W <br />Of <br />W <br />Q <br />W <br />N <br />O <br />u <br />O <br />V <br />ewc <br />o <br />N <br />0 <br />Ln <br />0) <br />00 <br />w <br />J <br />O <br />p <br />H <br />= <br />M <br />p <br />M <br />O <br />oV <br />~ <br />OJ <br />V <br />r+ <br />X <br />v <br />t7 <br />w <br />GC <br />Z <br />L- <br />00CC <br />V <br />Q <br />N <br />a <br />W <br />�* <br />W <br />w <br />2 <br />m <br />C <br />Z <br />O <br />J <br />V <br />a <br />cn <br />QJ <br />L <br />N <br />H <br />a <br />N <br />W <br />0 <br />v <br />LL <br />LLJ <br />U <br />z <br />LLJ <br />J <br />1 <br />0 <br />�C <br />a <br />V <br />0 <br />LU <br />Lf <br />0 <br />J <br />CL <br />0 <br />Uj <br />C <br />SEAL MAY <br />- <br />r4 <br />Ict <br />In <br />M <br />rn <br />_I <br />LL <br />In <br />J <br />J_ <br />a <br />LU <br />N <br />J <br />Q <br />L1J <br />Uj <br />M <br />R* <br />co <br />c� <br />co <br />m <br />o <br />LL CO <br />c� CO <br />CO <br />i- co <br />co <br />o x <br />ca <br />� N <br />CO o0 <br />0 <br />N CO <br />00 <br />cM <br />cn CID <br />O 00 <br />EL <br />e <br />3 o <br />r'> 0 <br />o � <br />cY) I- <br />ALVARO RODRIGUEZ <br />ARCHITECT AR95835 <br />3603 W. FLORA STREET. SUITE 101 <br />TAMPA FLORIDA 33614 <br />TELEPHONE (813) 389 8082 <br />DATE: 02/23/2018 <br />JOB N: 02418 <br />GENERAL <br />NOTES <br />OTypical Concrete Block Detail <br />1/2" = 1'-0" <br />TYPICAL MASONRY WALL SECTION <br />1/2" = 11-0" <br />Sheet <br />A-2 <br />