My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5010 9th St
Zephyrhills
>
Building Department
>
Building Plans
>
5010 9th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 3:50:36 PM
Creation date
2/18/2025 3:59:44 PM
Metadata
Fields
Template:
Building Plans
Street #
5010
Location
9th St
Contractor
The Kern Family
Building Plans - Permit #
18523
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIO <br />NO I DATE I DESCRIPTION I <br />Framina Layout Notes: <br />Framing layout drawn by Daniel M. Ossman Drafting Service, Inc. is a schematic <br />representation only. It is the responsibility of the General Contractor to make a field <br />inspection to verify "ALL" existing field conditions including accuracy in dimensions with <br />proposed plans. General Contractor "MUST' certify in writing (the time and date) that <br />this field inspection was conducted on and submitted to truss manufacture. If this field <br />inspection was "NOT" done prior to giving said plans to the truss manufacture, then the <br />"GENERAL CONTRACTOR WILL BE HELD LIABLE FOR ALL COST OF ANY / ALL <br />MISTAKES" on pre-engineered trusses that are constructed for said project. Daniel M. <br />Ossman Drafting Service, Inc. "WILL NOT BE HELD LIABLE" for errors made on any <br />framing (fEoor or roof) truss layouts. <br />2 Upon receiving said plans from the General Contractor— the truss manufacture <br />"MUST" make a their "OWN" field inspection to "DOUBLE CHECK" all existing field <br />conditions, roof slopes, overhangs, and dimensions prior to the manufacturing of any / all <br />trusses. Truss manufacture "MUST" certify (the time and date) that this field inspection <br />was conducted on by their company. This certification must be given to the General <br />Contractor in writing prior to the manufacturing of any / all trusses on said project. <br />3 All thickened slabs / footing on foundation plan are located according to the schematic <br />truss layout drawn by Daniel M. Ossman Drafting Service, Inc. Only truss manufacture <br />can change these locations due to truss bearing points and "MUST notify General <br />Contractor of these changes as soon as possible. <br />4 All hurricane truss straps specified on said project are to be used unless otherwise <br />specified by truss manufacture. All hurricane straps specified are "Simpson Strong Tie" <br />( or equal ), unless noted otherwise. Only truss manufacture can change any / or all <br />truss straps that are specified on truss layout drawn by Daniel M. Ossman Drafting <br />Service, Inc. Truss manufacture must first notify General Contractor in writing of these <br />changes as soon as possible. <br />5 Truss design drawings shall be prepared in accordance to and conformance with section <br />R802.1.6.1. These documents shall be provided by the truss manufacture at time of truss <br />delivery and approved by the building official prior to the installation of the roof truss. <br />(See code section items 1-13). <br />6 This plan as indicated is diagrammatical in nature for permit and contract purposes only. <br />Any revisions as required by the truss company's engineer as indicated on truss company's <br />sealed drawings shall superseded this drawing. This also includes truss company's <br />specified hurricane and other anchors supersede one shown on this drawing. <br />7 if shingles are being used, shingles MUST comply with section 905.2.2, 905.2.4.1 and <br />table R - 905.2.6.1 for wind resistance, FBC residential code 5th edition (2014) residential. <br />8 CONTRACTOR, MUST COORDINATE WITH TRUSS MANUFACTURE FOR ALL VAULTED, TRAY, <br />FLAT AND OR OTHER CEILING TYPES. CONTRACTOR IS 100% RESPONSIBLE FOR THE <br />EXTERIOR WALL CONSTRUCTION METHOD WHERE A GABLE END IS CONSTRUCTED. <br />ALL EXTERIOR WALLS MUST COMPLY WITH THE FBC RESIDENTIAL CODE 5TH EDITION <br />(2014) RESIDENTIAL, SECTION R - 609 FOR CONSTRUCTION METHODS. SEE ADDITIONAL <br />ATTACHED STRUCTURAL SHEETS FOR GABLE END BRACING DETAILS. DANIEL M. OSSMAN <br />DRAFTING SERVICE AND ARCHITECT WHO SIGNED / SEALED THE PLANS, ASSUMES NO <br />RESPONSIBILITY DUE TO NEGLIGENCE OF THE CONTRACTORS FAILURE TO FOLLOW <br />THE BUILDING CODE FOR GABLE END CONSTRUCTION. <br />Connection Schedule <br />Manufacturer <br />Model No. <br />Uplift <br />FI Product Approval <br />Location / Use <br />Name <br />Number <br />Simpson <br />Sp1 <br />#685 <br />FI 10456.11 R3 <br />Bottom plate to wood stud connection. <br />Strong Tie <br />Simpson <br />SP2 <br />#1065 <br />FI 10456.11 R3 <br />Top plate to wood stud connection. <br />Strong Tie <br />Simpson <br />Strong Tie <br />ABU44 <br />#2200 <br />FI 10860.4 R3 <br />4 x 4 bottom post connection to wood post. <br />Simpson <br />BC4 <br />#980 <br />FI 10860 R3 <br />4 x 4 top post connection to wood post. <br />Strong Tie <br />Simpson <br />HUSC210- <br />#3295 <br />FI 10655.25 R3 <br />2 - 2 x 10 wood beam hanger to exterior frame wall <br />Strong Tie <br />2 <br />of house. <br />Simpson <br />Roof structure connection to exterior frame wall or <br />Strong Tie <br />1-110 <br />#995 <br />FI 10456.3 R3 <br />wood beam. <br />Simpson <br />MTS20 <br />#1000 <br />FI 10456.8 R3 <br />Alternate - Roof structure connection to exterior <br />Strong Tie <br />frame wall or wood beam. <br />N <br />1. Any products that are substituted, must "MUST" or "EXCEED" products specified. Contractor "MUST" provide <br />data to building inspector at time of inspection. Only truss company can modify hurricane clips and connections <br />specified and must coordinate with General Contractor with any changes to plans. <br />2. It's the responsibility of the truss manufacture to coordinate all cathedral ceiling locations with General <br />Contractor before the manufacturing of any floor and / or roof trusses. All ceiling heights are to be a minimum <br />of 10' - 0" unless otherwise specified by General Contractor. <br />Main house roof pitch: 6.5 / 12 <br />Front porch roof pitch: 5 / 12 <br />Main house finish ceiling height: 10'-0" <br />Front porch finish ceiling height: 8' - 0" <br />All door and window header height to <br />start at: 8' - 0" <br />ROOF FRAMING LAYOUT <br />&. Jt -1 n,v 1.J 1 v <br />e 24 1, O. G , (GYP,) <br />PR E- - E t J l I� EE.QE.D <br />tZOo PTQ LJ SS E.,5 <br />E 2.4 110.G. <br />SEE ST2UCTUP.D,L <br />�LAEL-r FOR <br />EApE.e SIZE <br />(TYP.) <br />-2xi0WOOP <br />aEAt- I O YP) <br />� x g- P. T. WCo <br />;,05T (TyP) <br />V � � <br />� a+ <br />V � � <br />•� c c <br />ot <br />00 <br />c <br />• C c. � <br />n a� 0 <br />U7 L T- N <br />r <br />C �o Woo <br />a���oCy) <br />c ca o��(5 <br />U 04 V1 <br />Nc�M <br />M •Ucri� O <br />�wu <br />E IV 2 E <br />O L-� U 2 W n <br />cnQ>� <br />oCc>> D E o <br />t E �_ °, <br />2 c E —0 4) > <br />cM oUC <br />72 v co <br />N - U) <br />c ._ � �_ 0 <br />-r CN <br />W U-) <br />(3) M <br />co <br />U) L. <br />Ri <br />< � U- <br />0 <br />C) s <br />CL <br />LC) (D <br />..J <br />jOB NO. <br />5010 9TH STREET <br />DATL <br />APRIL 3, 2017 <br />DRAWN BY <br />Daniel M. Ossman <br />SCALE: 1 /4" = 1' - 0" <br />SHFF-T NO. <br />A-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.