IRRIGATION DETAILS
<br />PEDESTAL MOUNT IRRIGATION
<br />CONTROLLER ON CONCRETE °
<br />FOOTING. USE GALV. J'
<br />BOLTS TO SECURE THE
<br />CONTROLLER TO THE PAD.
<br />OR RECEPTACLE AND
<br />LOCKING SWITCH.
<br />14 GA, WIRES
<br />1" SCH. 40 CONDUIT FROM FIELD.
<br />WITH SWEEP ELL FOR
<br />120 VOLT SOURCE. 1 1/2" PVC
<br />m ©A, SCHEDULE 40
<br />CONCRETE BASE: CONDUIT WITH
<br />5" MIN. THICKNESS, LONG SWEEP ELL.
<br />EXTEND 6" BEYOND < M
<br />OUTSIDE DIMENSIONS
<br />OF ENCLOSURE WITH - I _ I-=1
<br />(-
<br />SLOPE FOR DRAINAGE. -IT _ I_ITI
<br />8 Ff. COPPER CODE. I �• I
<br />AS PER LOCAL CODE.
<br />1 PEDESTAL MOUNT CONTROLLER
<br />1" - 12" 32-8409.16-03
<br />2' MINIMUM, 4" MAXIMUM
<br />2" ABOVE FINISH
<br />BELOW TOP OF BOX.
<br />GRADE AT SHRUBS.
<br />1OX15 RECTANGULAR VALVE BOX.
<br />3/4- ABOVE FINISH
<br />REMOTE CONTROL VALVE, ONE PER BOX.
<br />GRADE AT LAWN.
<br />PLASTIC I.D. TAG AT EACH VALVE.
<br />WATER PROOF WIRE CONNECTORS
<br />ON 30' LOOPED WIRES.
<br />w
<br />OUTLET PIPE SAME SIZE
<br />AS VALVE, VALVE, 24" MIN.
<br />TFI
<br />2"
<br />J-,-
<br />TO FIRST FITTING.
<br />^ 1GL r-j=Tr T
<br />0
<br />45 DOWN AS
<br />I
<br />m
<br />RAL
<br />LATERAL
<br />PIPE
<br />SENSOR
<br />-INCH SCH 40 RISER
<br />NSION (FIPT X MIPT)
<br />JRED TO ENCLOSURE
<br />SCH 40 NUT
<br />TO CONTROLLER
<br />TROLLER PEDESTAL
<br />NOTE: MOUNT SENSOR WHERE
<br />IT WILL BE EXPOSED TO UNOBSTRUCTED
<br />RAINFALL, NOT IN PATH OF SPRINKLER
<br />SPRAY.
<br />RAIN SENSOR
<br />4
<br />III
<br />= III
<br />-=11--'II:,, III=III=1I '
<br />o - L-
<br />3 TURF POP UP HEAD.
<br />B"
<br />z 1/2" MARLEX STREET ELL.
<br />TO CURB OR
<br />BARB ELL X MI
<br />WALK.
<br />WALL
<br />MERLE
<br />R FENCE.
<br />STREET
<br />STREET ELL.
<br />4 U pCv O
<br />Pll�IRZIILATERAL O O v O O
<br />LINE AS PER
<br />IRRIGATION PLAN.
<br />CONCRETE BRICK SUPPORT,
<br />TWO ON EACH SIDE.
<br />6" THICK LAYER OF GRAVEL - PVC TEE (S%SXT)
<br />OR ELL. f112"LYETHYLENE FLEXIBLE
<br />SCHEDULE 80 RISER. LATERAL LINE. TUBING, LENGTH AS REQUIRED.
<br />MAIN LINE.
<br />ELECTRIC REMOTE CONTROL VALVE TURF SPRAY & STREAM BUBBLER ASSY.
<br />4 1 1/2" - 12" 328406.13-01 5 3" - 12' 328403.13-02
<br />1 0 " DIAMETER ROUND VALVE
<br />SET BOX 2" ABOVE GRADE AT SHRUBS. -
<br />BOX, SEE SPECIFICATIONS.
<br />SET BOX
<br />FLUSH TO GRADE
<br />AT LAWN.
<br />FINISH GRADE. �1
<br />3o I=111
<br />m FOUR COMMON
<br />`1 BRICK SUPPORTS.
<br />10" DIA. PVC PIPE
<br />EXTENSION, LENGTH
<br />AS REQUIRED.
<br />ISOLATION VALVE AS I / /T PVC MAIN LINE.
<br />SPECIFIED. L SLIP/THREAD COUPLING.
<br />SCHEDULE BO THREADED
<br />NIPPLE.
<br />BRONZE ISOLATION VALVE
<br />U 1 1/2" - 12" 328406.33-01
<br />G
<br />III=1 j-L • "
<br />-Uy=Uy
<br />INSTALL ASSEMBLY _ _ _
<br />OVE
<br />FINISHED GRADE.-FI-1, ly�yl I-
<br />III III III
<br />m DO NOT USE SIDE INLET.
<br />HIGH POP HEAD.
<br />8"
<br />z_ 1/2- MARLEX STREET ELL.
<br />TO CURB 0
<br />BARB ELL X MIPT.
<br />WALK.
<br />f STREET AELLX��
<br />LATERAL -/
<br />LINE. \1
<br />PVC TEE (SXSXT)
<br />OR ELL.
<br />1/2- POLYETHYLENE FLEXIBLE
<br />TUBING, LENGTH AS REQUIRED.
<br />SHRUB SPRAY HIGHPOP WIFLEX ASSEMBLY
<br />U 3" = 12" 328403.29-01
<br />IRRIGATION NOTES
<br />1. IRRIGATION SYSTEM DESIGN REQUIREMENTS: 26 GPM ® A
<br />MINIMUM OF 50 PSI AT THE POINT OF CONNECTION. THE
<br />IRRIGATION CONTRACTOR SHALL VERIFY THE AVAILABLE GPM AND
<br />PSI PRIOR TO INSTALLATION OF THE SYSTEM.
<br />2. PLANNED SOURCE IS AN EXISTING RECLAIMED WATER
<br />ASSEMBLY AND METER ON THE MAIN SITE, AND AN EXISTING
<br />RECLAIMED WATER ASSEMBLY ON THE SECONDARY SITE ACROSS
<br />8TH STREET. LOCATE EXISTING SYSTEM COMPONENTS, INCLUDING
<br />MAINLINE, TO DETERMINE THE BEST POINTS OF CONNECTION.
<br />3. DO NOT WILLFULLY INSTALL THE IRRIGATION SYSTEM AS
<br />SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD
<br />THAT CONDITIONS EXIST THAT MIGHT NOT HAVE BEEN KNOWN IN
<br />THE DESIGN PROCESS. FOR EXAMPLE : OBSTRUCTIONS, GRADE
<br />DIFFERENCES, WATER LEVELS, DIMENSIONAL DIFFERENCES. ETC.
<br />REFER TO THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH
<br />PROPOSED TREES OR SHRUBS.
<br />4. PIPING MAY SOMETIMES BE INDICATED AS BEING LOCATED IN
<br />UNLIKELY AREAS: I.E., UNDER BUILDINGS OR PAVEMENT,
<br />OUTSIDE OF PROPERTY LINES, IN LAKES OR DITCHES, ETC.
<br />THIS IS DONE FOR GRAPHIC CLARITY ONLY. WHENEVER POSSIBLE,
<br />PIPING IS TO BE INSTALLED IN OPEN, LANDSCAPE AREAS.
<br />5. IF REQUIRED, THE IRRIGATION CONTRACTOR SHALL PROVIDE
<br />THE NECESSARY "RIGHT OF WAY" USE PERMITS.
<br />6. PIPE SIZES SHALL CONFORM TO THOSE ON THE DRAWINGS.
<br />SUBSTITUTING WITH SMALLER PIPE SIZES WILL NOT BE
<br />PERMITTED.
<br />7. MAINLINE IS TO BE INSTALLED WITH A MINIMUM OF 24"
<br />DEPTH OF COVER. LATERAL LINES ARE TO BE INSTALLED WITH A
<br />MINIMUM OF 12" DEPTH OF COVER.
<br />8. UNLESS OTHERWISE INDICATED, ALL SLEEVES ARE TO BE
<br />PVC CLASS 200 AND TWO (2) NOMINAL SIZES LARGER THAN
<br />THE PIPE TO BE SLEEVED. FOR EXAMPLE: THE SLEEVE FOR A
<br />2" PIPE SHALL BE 3". NO IRRIGATION SLEEVE SHALL BE
<br />SMALLER THAN 2".
<br />9. WHEREVER PRACTICAL, INSTALL VALVES IN MULCHED BEDS
<br />AND/OR OUT OF HIGH TRAFFIC AREAS. ALL VALVES AND WIRE
<br />SPLICES SHALL BE INSTALLED IN VALVE BOXES.
<br />10. REFER TO VALVE DESIGNATION SYMBOLS FOR CONTROLLER,
<br />STATION NUMBER AND DESIGNED FLOW RATE FOR EACH REMOTE
<br />CONTROL VALVE.
<br />11. ALL 24 VOLT CONTROL CABLE TO BE ILL LISTED, SINGLE
<br />STRAND, TYPE OF 600 VOLT CONTROL CABLE. SIZE AND COLOR
<br />AS FOLLOWS:
<br />COMMON WIRES - SIZE AWG #12 OR LARGER AND
<br />WHITE IN COLOR.
<br />HOT WIRES - SIZE AWG #14 OR LARGER AND RED
<br />IN COLOR.
<br />SPARE WIRES - SIZE AWG #14 OR LARGER AND
<br />BLUE IN COLOR.
<br />12. ALL SPLICES TO THE 24 VOLT CONTROL WIRING SHALL BE
<br />MADE WITH RAIN BIRD #OBTWC 24-600 VOLT, DIRECT BURY
<br />SPLICE KITS.
<br />13. ALL CONTROL VALVE WIRES SHALL BE BUNDLED AND TAPED
<br />TOGETHER AT 20' INTERVALS AND PLACED ALONG THE S1DE OF
<br />THE MAINLINE PIPE.
<br />14, ALL POP-UP SPRINKLER HEADS SHALL BE INSTALLED LEVEL
<br />AND FLUSH TO GRADE. MOUNT ALL SPRINKLERS ON FLEXIBLE
<br />CONNECTIONS AS FOLLOWS:
<br />1/2" INLET SPRAY HEADS FLEXIBLE PIPE
<br />3/4" INLET ROTOR HEADS PVC SWING JOINT
<br />15. INSTALL HEADS 12" OFFSET FROM WALLS AND B" OFFSET
<br />FROM PAVING EDGES. INSTALL CONCRETE DONUTS AT HEADS
<br />CLOSE TO DRIVING SURFACES.
<br />>M- W
<br />J �
<br />O
<br />� � t
<br />U
<br />c
<br />w c
<br />c
<br />Q
<br />t
<br />U'
<br />c
<br />i
<br />16. LOCATION OF ALL SPRINKLER HEADS SHALL BE SITE
<br />ADJUSTED TO MINIMIZE WATER OVERTHROW ONTO BUILDING
<br />SURFACES AND WALKWAYS. THROTTLE VALVES ON SPRAY ZONES
<br />o�
<br />17
<br />JJ
<br />rFENCE OR WALL.
<br />PVC SLIP -THREAD ADAPTER.
<br />AS REQUIRED TO PREVENT FOGGING.
<br />1 SHRUB NOZZLE.
<br />12"
<br />BUBBLER NOZZLE AS SPECIFIED.
<br />17. EXACT CONTROLLER LOCATION(S) SHALL BE COORDINATED
<br />CURB OR
<br />WITH AN OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION.
<br />WALK.
<br />3" ABOVE GRADE,
<br />UNLESS OTHERWISE STATED, THE GENERAL CONTRACTOR SHALL
<br />THERMOPLS71C
<br />WATER WELL AS PER
<br />PROVIDE 110 VOLT POWER TO THE CONTROLLER LOCATION(S).
<br />RISER UV RESISTANT
<br />PLANTING DETAIL
<br />THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE
<br />1/2' MALE NPT
<br />THREADED
<br />• ".-�I
<br />_
<br />.III -III-
<br />FINISHED GRADE.
<br />CONNECTION FROM THE POWER SOURCE TO THE CONTROLLER(S).
<br />}
<br />M
<br />p'
<br />III
<br />=�1.1
<br />I__I
<br />-ll1=ll1-11I-LLI
<br />18. AT EACH IRRIGATION CONTROLLER, INSTALL A "SECONDARY
<br />LL
<br />- _TTi_ -III
<br />-III _
<br />III-
<br />1-iilj=
<br />.�-I �I
<br />SURGE ARRESTER" TO THE INCOMING (120 VOLT) POWER SUPPLY
<br />.III
<br />STRAIGHT
<br />I -1 -1 I
<br />-T�-�
<br />lil
<br />_�� �'"
<br />ROOT BALL I-
<br />(INTERMATIC #AG2401 OR EQUAL).
<br />cc
<br />-*-RISER
<br />OFF OF LATERAL
<br />_III- -
<br />-III- -=
<br />-'-�
<br />- 1 /2" IPS FLEX HOSE WITH
<br />19. AT THE CONTROLLER, INSTALL A SUPPLEMENTARY EARTH
<br />cc
<br />o
<br />WHERE OCCURS.
<br />_
<br />-
<br />L
<br />PVC FLEX GLUE AND PRIMER. 3
<br />GROUND GRID WITH A MINIMUM OF TWO 4'X96" GROUNDING
<br />-III=III-
<br />LENGTH AS REQUIRED.
<br />PLATES. TEST THE RESISTANCE TO EARTH PER NFPA STANDARD
<br />=..�
<br />PCV LATERAL LINE. m
<br />#780. AN ACCEPTABLE EARTH GROUND SHOULD HAVE 15 OHMS
<br />(n
<br />p
<br />PVC THREAD THREAD
<br />OR LESS RESISTANCE. USE MORE PLATES OR GROUNDING RODS
<br />Z`
<br />w
<br />m
<br />[II
<br />COUPLER.
<br />IIPTHREAD
<br />S-
<br />ADAPTER.
<br />AS NEEDED TO ACHIEVE THE DESIRED RESISTANCE READING.
<br />LG•
<br />I I
<br />20. THE IRRIGATION CONTRACTOR SHALL PREPARE AN AS -BUILT
<br />LL
<br />PVC LATERAL
<br />KBI FR-500-4
<br />DRAWING ON REPRODUCIBLE PAPER DETAILING THE ACTUAL
<br />r Q
<br />I I LINE.
<br />4" FLEX RISER.
<br />INSTALLATION OF THE IRRIGATION SYSTEM, THE AS -BUILT
<br />G
<br />PVC SLIP SUP
<br />DRAWINGS SHALL LOCATE ALL MAIN LINE PIPING, CONTROL WIRES,
<br />WIRE SPLICES, SLEEVES AND VALVES BY SHOWING EXACT
<br />AU
<br />1.�
<br />I I TEE.
<br />PVC THREAD
<br />36"t
<br />MEASUREMENTS FROM PERMANENT FEATURES (BUILDINGS, EDGE
<br />O
<br />SUP ELL.
<br />OF PAVEMENT, POWER POLES, FIRE HYDRANTS, ETC.). INCLUDE
<br />r^
<br />V' LP J
<br />DEPTH OF COVER ON MAINLINE AND SLEEVES.
<br />J 'r/� {� Z
<br />NIPPLE AS REQUIRED.
<br />21. NO PRODUCT SUBSTITUTIONS WILL BE PERMITTED WITHOUT
<br />S H RUB S P R A Y KBI FIXED
<br />RISER
<br />BUBBLER 0 N F L E X H 0 S E R IS E R
<br />THE WRITTEN PERMISSION OF THE OWNER'S REPRESENTATIVE.
<br />IRRIGATION CONTRACTOR TO PROVIDE SUBMITTALS TO THE
<br />TN
<br />i O J U
<br />7
<br />$
<br />3" = 12"
<br />328403.23-01
<br />3" = 12" 328403.53-01
<br />OWNER'S REPRESENTATIVE FOR APPROVAL PRIOR TO
<br />INSTALLATION.
<br />/ 1
<br />V
<br />22. ANY OTHER EQUIPMENT REQUIRED THAT IS NOT OTHER WISE
<br />2 N
<br />DETAILED OR SPECIFIED SHALL BE INSTALLED AS PER
<br />LL �:
<br />MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODE.
<br />Z
<br />23. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
<br />N Z N U
<br />Comm. N. 12010.00
<br />Dale: 01 / 16/ 14
<br />D.- CJC
<br />ro nE ear a wr a+onuoa. me
<br />PUM9 N!D �EWII. WLIPLY MIX
<br />IMF MXMUY WWI. Nta.
<br />c 2014 HARVARD JOLLY. INC.
<br />IR2.0