Laserfiche WebLink
— — — — — — — — — — - — — — — — — — — - — — — — — — — — — — — — — — — <br />GENERAL NOTES: <br />I <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2001 FLORIDA BUILDING CODE A CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />AND 2009 SUPPLEMENTS PEST CONTROL COMPANY BEFORE A " CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE <br />ARKAY ENGINEERING INC: A REGISTERED LICENSED, FLORIDA PROFESSIONAL STRUCTURAL SHALL STATE: (PER FBC) <br />ENGINEERING COMPANY, HAS APPLIED RATIONAL ANALYSIS FOR THE STRUCTURAL DESIGN THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN EXISTING CHURCH <br />OF THIS STRUCTURE � RE TERMITES. THE TREATMENT 18 INACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT I <br />OF AGRICULTURE AND CONSUMERS SERVICES <br />THE BUILDING l INCLUDING ALL COMPONENTS AND CLADDINGS SHALL BE DESIGNED FOR THE I <br />FOLLOWING SUPERIMPOSED LOADS INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION <br />FLOORS: BACKFILLINGs 4 COMPACTION ARE COMPLETE ( PER FBC) <br />LIVE LOADS - 40 P.S,F, <br />DEAD LOADS - 10 P,S,F, ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE- TREATED <br />INCLUDING ANY BOX OR FORMED AREAS ( PER FBC) <br />SLAB, <br />- LIVE LOADS 50 P,S,F, BOXED AREA IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE I <br />DEAD LOADS - 10 P.S.F. WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF AN <br />ROOF= ADEQUATE SIZE t DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />LIVE LOADS (TRUSS TOP CORD) - 20 P,S,F, INITIAL TREATMENT ( PER FBC) <br />DEAD LOADS (TRUSS TOP CORP) - 10 P.S.F. <br />DEAD LOAD (TRUSS BOTTOM CORD) - 10 P,S.F, A MINIMUM 6 MILL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL - - - - - - - - <br />ASSUMED TRUSS SELF WEIGHT ( DEAD LOAD) - 1 P.S.F. EXIT E <br />DILUTION IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE TREATMENT SHALL- _ --� <br />WIND DESIGN ASSUMPTIONS, BE REQUIRED (PER FBC) ' <br />COMPLIES WITH SECTION 1609 FBC ATTIC STAIRS ) <br />BUILDING EXPOSURE - IS ANY CONCRETE OVERPOUR , MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION <br />BUILDING IMPORTANCE FACTOR ■ 1,0 PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT. ( PER FBC) <br />MEAN ROOF HEIGHT 30' OR LESS - -� , <br />HEIGHT / EXPOSURE ADJUSTMENTS COEFFICIENT . 1,0 <br />ENCLOSED BUILDING PH. <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />INTERNAL PRESSURE COEFFICIENT ■ + / - 0,18 WITHIN 12" OF THE STRUCTURE SIDE WALLS (PER FBC) ' ® ' <br />- - - - - AIR HANDLER IN6rALLED IN <br />SEE WIND SPEED AT BOTTOM RIGHT OF ALL SHEETS ATTIC AREA Musr coMPL7 I <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS WITH FLORIDA SUILONG CODE rL <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) ANY SOIL DISTURBED AFTER THE <br />SOIL BEARING < COMPACTION: <br />VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED (PER FBC) <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF <br />CONDENSATE AND ROOF DOWN SPOUTS DISCHARGE AT LEAST 12" AWAY FROM THE BUILDING <br />2000 P,S.F,( MINIMUM ) THE CONTRACTOR/PROPERTY OWNER IS RESPONSIBLE FOR VERIFYING <br />SIDE WALLS (PER FBC) <br />THAT THE SOIL ON THE SITE 18 PROPERLY PREPARED AND COMPACTED SUCH THAT IT CAN <br />SUPPORT A 2000 P,S,F, FOUNDATION LOADINGS <br />AFTER ALL WORK IS COMPLETE ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITH IN 12" OF THE BUILDING, THIS SHALL INCLUDE ALL GRADE STAKES TUB <br />ARKAY ENGINEERING INC: A REGISTERED LICENSED FLORIDA PROFESSIONAL STRUCTURAL <br />TRAP BOXES, FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS <br />ENGINEERING COMPANY, DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION <br />PER (FBC) <br />SITE NOR PERFORMING ANY SOIL TESTING <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE <br />ARKAY ENGINEERING INC $HALL NOT BE RESPONSIBLE FOR THE SITE SOIL ABILITY TO SUPPORT <br />CEMENTITIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) <br />THE BUILDING LOADS <br />AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" TO ALLOW FOR INSPECTION FOR FUTURE <br />FOUNDATION t SLAB - ON- GRADE NOTES <br />TERMITE INFESTATIONS (PER FBC) <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS:, <br />EXTERIOR WINDOWS 4 DOORS: <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />ALL EXTERIOR WINDOWS 4 GLASS DOORS OR ENTRANCE DOOR SHALL BE TESTED IN ACCORDANCE WITH <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2000 F.S.F. FOUNDATION LOADING, SLAB <br />ANSI/AMMA/NWWDA 101/1-52 STANDARD AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURE <br />y SHALL BE PLACE OVER A 6 MIL VAPOR BARRIER ON CLEAN ADEQUATELY COMPACTED <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY <br />AND TERMITE POISONED SOIL <br />CONCRETE UTILIZED IN THE FOUNDATION AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TEST OR ENGINEERED TO TRANSFER <br />COMPRESSIVE STRENGTH OF 3000 P,S.i, <br />1,5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A -615, LAP SPLICES, WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR <br />INSTALL ALL WINDOWS AND DOOR ASSEMBLIES PER THE MANUFACTURE ANCHORING, RECOMMENDATIONS <br />„ <br />05 REBAR , 30 FOR 06 REBAR t 35 FOR Ml REBAR <br />TO ACHIEVE THE DESIGN PRESSURES SPECIFIED <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER <br />FINAL SITE GRADING) THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />ELECTRICAL, PLUMBING, t MECHANICAL: <br />EXACT STEMWALL HEIGHT BASE UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />r AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSE ARE REQUIRED <br />IN ACCORDANCE WITH CHAPTER 411.003 (2) (1) OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL <br />A FOUNDATION SURVEY SHALL BE PERFORMED AMC) A COPY OF THE SURVEY SHALL BE ON SITE <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO <br />FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A <br />MEET ALL APPLICABLE CODES, THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HERON <br />STRING STRECTED FROM MARKER TO MARKER TO VERIFY REQUIRED SET BACKS <br />ARE BASE UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />MASONRY WALLS: ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT <br />CONCRETE MASONRY UNIT SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90 ALL ELECTRICAL OUTLETS IN BEDROOMS < FIXTURES SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />AND SHALL WAVE MINIMUM F'M OF 1500 P.S.I. "Am" CIRCUIT <br />MORTAR SWALL CONFORM TO ASTMC -210 AMC) SHALL BE EITWER TYPE M OR S <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN WALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N,E,C, <br />WITH ASTMA-615, LAP SPLICES WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR 05 REBAR <br />3o" FOR 09, REBAR AND 35" FOR 01 REBAR. <br />SAFETY GLAZING: <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL WAVE A MAXIMUM COURSE AGGREGATE SIZE <br />OF we" PLACED AT 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATION FOR THE PURPOSE OF <br />2000 P,S,I, ( WHEN TESTED PER ASTM C-IOI9 J <br />GLAZING <br />PROVIDE CLEAN OUT OPENINGS ( 12 SQ. IN. ) IN CELLS CONTAINING SPLICED REINFORCEMENT. WHEN <br />(1) GLAZING IN SWING DOORS, FIXED AND SLIDING PANEL OF SLIDING DOORS <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT <br />ASSEMBLIES <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WWIRLPOOLS, SAUNAS, STEAM <br />TIMBER MATERIALS: <br />ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />ALL TIMBERS MATERIALS SHALL BE AS FOLLOWS: <br />THAN 60" ABOVE THE DRAIN INLET <br />EXTERIOR WALLS SHALL BE CONSTRUCTED WITH I/2" PLYWOOD OR 1/16" O,S,B. (2-M-lU RATING) NAILED <br />(3) GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE„ <br />WITH SD NAILS SPACE AT 3 Or- ALONG ALL HORIZONTAL JOINTS AND EDGES, 6 OC ALONG ALL VERTICAL <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 RADIUS OF THE DOOR IN A CLOSED <br />�_ <br />JOINTS AND EDGES AND 12 OC ALONG ALL INTERMEDIATE STUDS <br />POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE FINISH FLOOR OR <br />WALKING SURFACE <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T, <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL OTHER THAN THOSE LOCATIONS — — — — — - — — — — — — — — — — — — — '= — — — — — — — — — - - - — - - — — <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE , THAT MEETS ALL OF THE FOLLOWING <br />MAXIMUM 24 OC. WALLS TO HAVE 1/2 GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />(A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT, <br />GARAGE TO HAVE MINIMUM R-11 INSULATION <br />(B) BOTTOM EDGE LESS THAN IS" ABOVE THE FLOOR <br />(C) TOP EDGE GREATER THAN 36" ABOVE THE FLOOR I <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH INS MUST BE COMPLETE, INSPECTED AMC) APPROVED <br />(D) ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY <br />PRIOR TO REQUESTING THE FRAMING INSPECTION, <br />OF THE PLANE OF THE GLAZING <br />TRUSSES: <br />DRAFTSTOPPING: I <br />IF THE CONTRACTOR , TRUSS MANUFACTURE OR ANY OTHER DESIGN PROFESSIONAL REVISE THE <br />IN SINGLE FAMILY DWELLINGS DRAFTSTOPPINGS SHALL BE PROVIDED ( PARALLEL TO THE MAIN <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS ARKAY ENGINEERING, INC IS <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE <br />FRAMING MEMBERS) IN FLOOR / CEILING ASSEMBLIES SEPARATING USEABLE SPACES, DRAFTSTOPPING EXISTING CHURCH <br />DESIGN INTENT PRIOR TO COMMENCEMENT OF THE PROJECT <br />SHALL BE CONSTRUCTED SUCH THAT THE FLOOR / CEILING ASSEMBLEY IS BROKEN UP INTO TWO OR MORE <br />a <br />APPROXIMATED AREAS WITH NO AREA GREATER THAN 1000SQ,FT, <br />SOIL TERMITE TREATMENT: <br />I <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMItICiDEB, INCLUDING PESTICIDES <br />SS: <br />ATTIC ACCESS: <br />APPLIED TO SOIL, OR WOOD, BATING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQ, FT, AND WAVING <br />USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />MINIMUM 30 INCHES OF VERTICAL HEIGHT, ROUGH FRAMED OPENING NOT BE LESS THAN 22"X30" <br />INCHES, WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC IT SHALL BE INSTALLED' IN <br />ACCORDANCE WITH 2O04 FLORIDA BUILDING CODE RESIDENTIAL - SECTION 111305,1.3 <br />. I <br />50 CFM - - - - - <br />8X47><4, - - - - - <br />/]A <br />ATTIC STAIRS FR <br />25X20 <br />R!CHARF L.IKIDDI= P.E, <br />F4_ORL.4 Li^ENSE NUM( ER 312SC <br />Y CERTIFY THAT T4 5Ll PLANS AMC)SPECIFICATIONS <br />HERBE E PL D P <br />WERE PREPAIED BY ME OKUNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCk, WITH CHAPTER 16, SECTION *O9 OF THE <br />UI DI' CODF 7001 F 120.M H (3 CO GUST) <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE ' I ` , /� /� �{ I I � I I FLORIDAB L MG � . OR P SECOND <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND TAT Y AC FLAN 1/4 1 O WIND ZONE - 100 MPH FASTEST "SPEED AND THE ENTIRE 2001 <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE FLORIDA BUILDING CODE AMC) 200E SUPPLEMENTS <br />m <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />m <br />z In <br />z u tn fu <br />Z tn m <br />a no <br />~ <br />O W L► <br />Z ON <br />Ql � U <br />wIn <br />z <br />Qm <br />pi W 0 <br />U1 <br />< <br />W <br />O a.LL <br />A <br />U } <br />aC] <br />ry <br />Q OIN <br />m <br />in <br />I fU <br />w In <br />ui m <br />o Jw <br />C[)LL <br />mLL <br />0 <br />r- <br />Ulto � <br />co s <br />m0 <br />cs1cold <br />V J <br />z Q�1 <br />zam <br />Z <br />lu 1� �Q <br />�m <br />p� <br />w 0 U- <br />0 � <br />u_ d) <br />F- <br />>A <br />cN <br />a <br />Q1 <br />! <br />CD <br />_m <br />Z <br />O O <br />� <br />� z <br />Q <br />�N <br />U m <br />ILL <br />IL <br />N <br />TOTAL AREA <br />580 $0, FT. <br />FIG <br />�OF4 <br />,4RIC,AY I�'� <br />