Laserfiche WebLink
- ARROW INDICATES <br />LONG DIR. OF PLYWD. <br />O 24" O.C. <br />GABLE END TRUSS <br />(WEBS REMOVED <br />FOR CLARITY) <br />X 10d COMMONS OR 8d RING SAHNK O 4 <br />O.C. ON EACH SHEET OF PLYWOOD <br />0 = 10d COMMONS OR 8d RING SHANK O 6" <br />O.C. ON EACH SHEET OF PLYWOOD <br />❑ - 10d COMMONS OR 8d RING SHANK O 8" <br />O.C. ON EACH SHEET OF PLYWOOD <br />NAILING SCHED./GABLE <br />SCALE: N.T.S. <br />ROOF EDGE <br />0 - 8d O 6" O.C. ON EACH SHEET OF PLYWOOD <br />NAILING SCHED./HIP <br />SCALE: N.T.S. <br />I <br />O O <br />O RIDGE O <br />I I <br />O O. <br />-1 <br />O3 0 JP��� 1LIJ <br />4'-0" O I 0 <br />L_ <br />- - - - - - - - - - <br />ROOF SHEATHING NAILING PATTERN <br />NOT TO SCALE <br />ZONE <br />0 <br />Structural Notes- <br />"i <br />8d RING -SHANK NAILS 0 6" O.C. 0 EDGES <br />& 12" O.C. INTERMEDIATE <br />8d RING -SHANK NAILS 0 6" O.C. 0 EDGES <br />& 12" O.C. INTERMEDIATE <br />8d RING -SHANK NAILS 0 6" O.C. 0 EDGES <br />& 6" O.C. INTERMEDIATE <br />5'- 0" <br />1. DESIGN CRITERIA: <br />1.1 Dwelling floors - 40 PSF live load. <br />1.2 Balconies -60 PSF live load. <br />1.3 Walkways - 80 PSF Live load. <br />1.4 Roof - 30 PSF live load. 17 PSF (7 PSF T/C & 10 PSF B/C) dead <br />load for shingle roofs: 25 PSF(15 PSF T/C & 10 PSF B/C) dead load for concrete <br />tile roofs. <br />1.5 Wind -137 MPH, per FBC unless noted otherwise. <br />1.6 Net uplift dead loads 10 PSF Shingle 15 PSF tile. <br />1.7 Building Risk Catagory - II <br />1.8 Wind Exposure - B <br />1.9 Internal Wind Pressure Coefficient (GCpi) - +/-0.18 <br />1.10 Flood Zone Classification - X <br />1.11 Design conducted under the assumption that the building acts as an unprotected, <br />enclosed structure. Design uses ASCE 7-10, simplified method. <br />2.) CODES: <br />2.1 The Florida Building Code (2010). <br />2.2 Building code requirements for reinforced concrete (ACI 318-05) <br />2.3 American Society of Civil Engineers minimum design loads for buildings and other <br />structures (ASCE 7-10). <br />2.4 Specification for the design, Fabrication and erection of structural steel for <br />buildings (AISC 9th edition). <br />2.5 "Design Specification for light metal plate connected wood trusses" by the Truss <br />Plate Institute (TPI 1-2002). <br />2.6 Building Code Requirments of Masonry Structures (ACI 530-05) <br />1.7 National Design Specification for Wood Structures (AF&PA-NDS-05) <br />3. SOIL: <br />3.1 Minimum allowable soil pressure 2000 PSF. <br />4.) CONCRETE: <br />4.1 Concrete compressive strength at 28 days: 2500 psi (normal weight). <br />4.2 Reinforcing bars: ASTM A615 (Grade 60). <br />4.3 Welded wire fabric (WWF): ASTM A185. <br />4.4 Detail reinforcement in accordance with ACI 315. <br />4.5 Concrete coverage of reinforcement: Footings 3: bottom and sides. <br />4.6 Earth supported slabs: (including exterior walk and drive slabs) 4" thick, reinforced <br />with 6x6 w1.4x w1.4 W.W.F. at mid depth of slab. fibermesh may be used in lieu of WWF <br />contractor's option. <br />4.7 Concreting operations shall comply with ACI standards. <br />4.8 Lap splice shall be as follows: #5 bar 25", #4 bar 20", #3 bar 15". <br />5.) MASONRY: <br />5.1 Design and construction shall conform to the specification of the National concrete <br />masonry Association and ACI 530. <br />5.2 Minimum masonry unit strength: (Fri) 1900 PSI <br />5.3 Mortar shall be type S or M. <br />5.4 All Block cells and cavities below grade shall be filled with concrete. <br />5.5 Fill cells w/(1) #5 bar shall be located PER PLAN ( 6'-0" O/C TYP.) at each corner and <br />each side of openings greater than or equal to 6'-0". fill cells w/(2) #5 vert. shall be <br />located at each side of openings 10'-0" and greater, at all girder bearings, including <br />hip -set girders. <br />NAILING SCHEDULE <br />Ledger stri , face nail <br />16d common <br />3 at each joist <br />Sole plate to joist or <br />16d common <br />6O.C. <br />blocking, face nail <br />Top of sole plate to stud, <br />16d common <br />2 <br />end nailed <br />Stud to sole plate, toe nail <br />8d common <br />4 <br />Doubled studs, face nail <br />16d common <br />24 O.C. <br />Doubled top plates, face <br />1 d common <br />16 O.C. <br />nail <br />Continuous header to <br />8d common <br />stud, toe nail <br />1 x sheathing or less to <br />8d common <br />3 <br />each bearing, face nail, ea stud <br />Over 1 x sheathing to <br />8d common <br />3 <br />each bearing, face nail, ea stud <br />3/4" Floor sheathing <br />8d common <br />4" o.c. 0 edges & <br />6 o.c. intermediate <br />Build-up corner studs <br />16d common <br />24" O.C. <br />Build-up girders and <br />20d common <br />32 O.C. at top <br />beams up to three members, <br />and bottom <br />face nail <br />staggered on opp. <br />sides, 2 at ends and at <br />each splice <br />1 Gypsum Sheathing <br />11 go 1-3/4' <br />4 O.C. at edges <br />7 16" head <br />8" o.c. at other bearing <br />Gypsum Sheathing <br />11 go 1-3/4" <br />4 O.C. at edges <br />3/8" head <br />8" o.c. at other bearin <br />Gypsum Wallboard <br />0.120" nail, min. <br />7"O.C. on ceilings <br />1/2 <br />1-1/2"long, 3/8" head <br />8"O.C. on walls <br />Gypsum Wallboard <br />0.120" nail, min. <br />7"O.C. on ceilings <br />5/8" <br />1-3/4"long, 3/8" head <br />8"O.C. on walls <br />Hardboard Lap Siding, <br />8d corrosion resistant <br />16 O.C. at top <br />Direct to Studs <br />with minimum shank <br />and bottom edges <br />dia. of 0.0990 inch <br />and minimum head <br />dia. of 0.240 inch <br />Hardboard Lap Siding, <br />10d corrosion resistant <br />16 O.C. at top <br />over sheathing <br />with minimum shank <br />and bottom edges <br />dia. of 0.0990 inch <br />and minimum head <br />dia. of 0.240 inch <br />Hardboard Panel siding, <br />6d corrosion resistant <br />4 O.C. at edges <br />Direct to Studs <br />with minimum shank <br />& boundaries <br />dia. of 0.0920 inch <br />12" O.C. at <br />and minimum head <br />Intermediate <br />dia. of 0.225 inch <br />supports <br />Hardboard Panel siding, <br />8d corrosion resistant <br />6 O.C. at edges <br />Over sheathing <br />with minimum shank <br />12" O.C. at <br />dia. of 0.0920 inch <br />Intermediate <br />and minimum head <br />supports <br />dia. of 0.225 inch <br />* Ceiling joists, laps over <br />partitions, face nail <br />16d common <br />3 minimum <br />* Ceiling joists to parallel <br />rafters, face nail <br />16d common <br />3 minimum <br />* Collar tie to rafter, face nail <br />10d common <br />3 <br />* Roof ra ter to 2x ridge <br />beam, toe nail <br />16d common <br />2 <br />* Applicable to conventional roof framing only <br />6. WOOD: <br />6.1 Wood framing structural members: #2 southern yellow pine (unless noted otherwise) with <br />allowable bending stress (Fb) = 1250 PSI and a modulus of elasticity = 1,600,000 PSI <br />(does not include interior non load bearing stud walls). <br />6.2 Design, fabricate and erect wood trusses in accordance with the "design specification <br />light metal plate connected wood trusses" by the truss plate institute (TPI-02), and <br />HIS 91 (if applicable). <br />6.3 All exposed wood or wood in contact with earth or concrete to be pressure treated. <br />6.4 Roof sheathing: 5/8" C.D. grade plywood (or 19/32" OSB), when using fiberglass/asphalt <br />shingles over felt. <br />6.5 Untreated wood shall not be in direct contact with concrete. SEAT plates shall be provided <br />at bearing locations without wooden top plates. <br />7. GANG- LAM LVL: <br />7.1 Gang -Lam. stress grades shall provide the following minimum properties: <br />E = 2,000,000 PSI <br />Fb = 3,100 PSI <br />Ft = 2,300 PSI <br />Fc1 = 1020 PSI (perpendicular) <br />Fc11 = 3,180 PSi (parallel) <br />Fv = 290 PSI <br />Contact engineer if other types of LVL beams are to be used. <br />8. STEEL: <br />S.? installation of aN steel to be performed by a qualified, licensed steel erector. <br />8.2 Fabricate and erect aii structurai steel in accordance with AiSC "Specifications for the design, <br />fabrication, and erection of structural steel for buildings." <br />8.3 Structural steel to be ASTM A36 unless noted otherwise. <br />8.4 Steel tubing shall be ASTM A500, grade B. <br />8.5 Welded connections: E70XX electrodes, minimum size fillet welds 3/16", AWS certified welders. <br />8.6 Where steel beams are continuous over columns, provide web stiffener plates on each side of the <br />web, of a thickness equal to beam flange thickness, located at the center line of the tube column. <br />8.7 The steel frame is "non -self supporting". Adequate temporary support shall be provided by the <br />Contractor until required connections or elements are in place. <br />9. ;. TR Q SSE S: <br />9.1 ALL CONNECTORS SPECIFIED AS PER SIMPSON CATALOG C-2005. CONTACT <br />FLORIDA STRUCTURAL ENGINEERING FOR ALL CONNECTOR SUBSTITUTIONS. <br />9.2 PRE-ENGINEERED WOOD TRUSSES TO BE SPACED 0 24" O.,C. TYPICAL <br />UNLESS NOTED OTHERWISE ON TRUSS ENGINEERING PACKAGE. <br />9.3 iF THE TRUSS INFORMATION PROVIDED IN THESE CONSTRUCTION DOCUMENTS <br />IS REVISED BY ANY OTHER PARTY (TRUSS MANUFACTURER, CONTRACTOR, OTHER <br />DESIGN PROFESSIONAL), iT iS THE CLIENTS RESPONSIBILITY TO SUBMIT CHANGES TO <br />FLORIDA STRUCTURAL ENGINEERING FOR REVIEW. THE CLIENT IS RESPONSIBLE FOR ANY <br />CONSTRUCTION COSTS RESULTING FROM TRUSS PACKAGE REVISIONS DEVELOPED BY OTHERS. <br />PRE-ENGINEERED WOOD TRUSSES <br />- <br />0 24" O.C. MAX <br />SHINGLES OVER 15# FELT <br />1/2" CDX PLYWOOD ROOF SHEATHING, SEE SCHED- <br />ON SHEET S1 FOR ATTACHMENT. <br />SIMPSON HTS20 0 EA. TRUSS --\ <br />0 EA. BEARING LOCATION 12 <br />VI F <br />METAL DRIP EDGE <br />MATCH EXISTING FACIA <br />MATCH EXISTING SOFFIT - <br />DOUBLE 2%4" TOP PLATE <br />TYVEK - <br />MATCH EXISTING BRICK <br />1 /2" CDX PLY W/ 8d 0 4" O.C: <br />0 EDGES & BOUNDARIES, 12" <br />O.C. IN FIELD <br />1" AIRSPACE <br />FLASHING & WEEP HOLES <br />CAD 36" O.C. <br />SIMPSON SP1 ® EA. STUD <br />GRADE <br />C "X" BRACING DETAIL <br />S1 NOT TO SCALE <br />R-30 BATT <br />\--1 /2" GYPSUM <br />SIMPSON SP2 0 EA. STUD <br />2"X4" STUDS 0 16" O.C. <br />-5/8" TYPE X GYPSUM <br />-BLOCKING 0 MID HEIGHT <br />SIMPSON BT 0 24" O.C. MAX, E.W. <br />-R-13 BATT TYP. <br />-2"x4" BOTTOM PLATE W/ 1 /2" <br />DIA. ALLTHRED BOLTS W/ 6" MIN. <br />EMBED USING SIMPSON SET EPDXY <br />SPACED 0 24" MIN. <br />d <br />a <br />EXISTING CONCRETE SLAB <br />EXISTING FOUNDATION <br />TYP EXTERIOR WALL SECTION E <br />SCALE: 1 /2"=1'-O" <br />UM 94" CROSS <br />.ING EE PLAN <br />LOCATIONS) <br />16d PER JOINT <br />PRE-ENGINEERED WOOD TRUSSES <br />\ AT LEAST ONE TRUSS <br />SPACE <br />OVERLAP <br />�-MINIMUM (2) 12d PER JOINT <br />MINIMUM 1 "x4" TRUSS BRACING <br />D RAT -RUN BRACING DETAIL <br />S1 NOT TO SCALE <br />,)n'-n" MAY )n,-n" MAY <br />"X" BRACE SEE DETAIL7-\ <br />I <br />11■■ <br />ei�i� <br />�IA1 <br />NINE <br />nllfl <br />B <br />A HIP ROOF F-RAMING S1 <br />Si NOT TO SCALE <br />R❑❑E BRACING PLAN <br />NOT TO SCALE <br />BRACING 1"X4" MIN <br />C� <br />co <br />CD <br />00 <br />0'J <br />LO <br />co <br />LO <br />�-4k <br />co� <br />4A <br />Cc <br />r--1 <br />o <br />W Q)co <br />a <br />w <br />-I--� <br />p <br />N <br />1 <br />0 <br />0 <br />U <br />_ <br />M <br />I~ <br />N Z <br />w <br />Cd N <br />CX p 0 <br />Cd <br />�a <br />171 <br />o <br />O ,� °�° «c <br />CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO START OF ANY <br />CONSTRUCTION. FLORIDA STRUCTURAL ENGINEERING IS NOT <br />RESPONSIBLE FOR ANY DIMENSIONS. <br />FLORIDA STRUCTURAL ENGINEERING IS RESPONSIBLE FOR PROPOSED <br />CHANGES TO ORIGINAL STRUCTURE SHOWN ON THESE PAGES <br />ONLY. FLORIDA STRUTURAL ENGINEERING IS NOT RESPONSIBLE <br />FOR EXISTING STRUCTURAL COMPONENTS. <br />Plans and specifications comply with the Florida <br />Building Code, section 1609 for 137 mph, 3 second <br />gust, wind zone. (2010 Ed.) <br />This drawing is valid for 12 months after the date <br />it is signed and sealed or until the requirements of <br />the 2010 edition of the Florida Building Code are <br />changed. <br />This drawing Is signed and sealed for the structural <br />portions of the drawing only. Architectural, <br />electrical, or mechanical details, if shown, are for <br />visual reference only and are not covered under <br />this seal. <br />Project Name & Address: <br />VILLAGE WALK <br />39216 VILLAGE CHASE <br />ZEPHYRHILLS, FL 33540 <br />Date: Scale: <br />09/24/13 VARI❑US <br />L GABLE END BRACING <br />4'-0" O/C MAX FOR Sheet: <br />FIRST (4) RORWS VAMM>�l/ <br />(2) 2°x 4" BkA ��r;:----LOG <br />SEE DETAIL����F�,`cENSF -cMs�, <br />`��•.. ' •,cam <br />01 <br />No. , <br />I NP�,� <br />S-110 <br />