MASONRY WALLS <br />0 <br />01 CONRETE MASONARY UNIT SHALL BE HOLLOW UNIT <br />MASONARYIN ACCORDANCE WITH ASTM C-SO AND SHALL <br />HAVE MINIMUM F'M OF 1500 P.S.I. <br />02 MORTAR SHALL CONFORM TO ASTMC -210 AND SHALL BE <br />EITHER TYPE M OR 5, <br />03 REINFORCING STEEL SHALL BE GARAGE 40 MINIMUM AND <br />IDENTIFIED IN ACCORANCE WITH ASTMA-615.LAP SPLICES <br />WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR 05 REBAR <br />3011 FOR 06 REBAR AND 36" FOR 01 REBAR. <br />04 GROUT FOR POURED CELLS AND LINTELS SHALL HAVE A <br />MAXIMUM COURSE AGGREGATE SIZE OF 3/8" PLACED AT 8 TO <br />11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE <br />STRENGTH OF 3000 P.S.I. ( WHEN TESTED PER ASTM C-101S) <br />05 PROVIDE CLEAN OUT OPENINGS (12 SQ IN.) IN CELLS <br />CONTAINING SPLICED REINFORCEMENT. WHEN THE GROUT <br />POUR EXCEEDS 5 FEET IN HEIGHT, <br />GLAZING <br />GLAZING THE FOLLOWING SHALL BE CONSIDERED SPECIFIC <br />HAZARDOUS LOCATION FOR THE PURPOSE OF- <br />01 GLAZING IN SWING DOORS, FIXED AND SLIDING PANEL OF <br />SLIDING DOORS ASSEMEBLIES, <br />02 GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, <br />WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATH TUBS AND <br />SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE <br />OF THE GLAZING IS LESS THAN 60" ABOVE THE DRAIN INLET. <br />03 GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL <br />ADJACENT A DOOR WHERE THE NEARBY VERTICAL EDGE lS <br />WITHIN A 24" RADIUS OF THE DOOR IN A CLOSED POSITION <br />AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE <br />FINISH FLOOR OR WALKING SURFACE. <br />04 GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL <br />OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS (2) AND <br />(3) ABOVE. THAT MEETS ALL THE FOLLOWING <br />(A) EXPOSED AREA OF AN INDIVIDUAL PANEL OTHER THAN <br />THOSE LOCATIONS <br />(B) BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR <br />(C) TOP EDGE GREATER THAN 36" ABOVE THE FLOOR <br />(D) ONE OR MORE WALKING SURFACES WITHIN 36" <br />HORIZONTALLY OF THE PLANE OF THE GLAZING <br />REFER TO THE THE 2004 FLORIDA BUILDING CODE <br />RESIDENTIAL -SECTION R308 FOR ADDITONAL AREAS THAT <br />MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE <br />PURPOSE OF GLAZING <br />14'-O" <br />20'-0" <br />-4" 6'-an l0'-O" 10'-011 <br />THE BUILDER WANTS 8" BETWEEN THE UNITS <br />r <br />DESIGN PRESSURES <br />THE DESIGN WIND PRESSURE RATINGS ARE LISTED <br />FOR EACH OPENING.THE WINDOWS AND DOORS <br />CHOOSEN BY THE HOMEOWNER OR CONTRACTOR <br />WILL NEED TO MEET OR EXCEED THESE PRESSURES <br />LISTED BY EACH OPENING, THIS MANUFACTURERS <br />INFORMATION WILL BE REQUIRED BEFORE ANY <br />INSTALLATION OF THESE PRODUCTS. <br />tn <br />N <br />N <br />A <br />m" <br />O <br />m <br />R. S. HALE' <br />ATTIC VENTILATION <br />PAGE 3 <br />DESIGN SERVICES INC. <br />MOBILE/ OFFICE 352-206-5821 <br />OFFICE FAX 352-588-2342 <br />P 0 BOX 1325 SAN ANTONIO <br />FLA, 335-16 <br />EMAIL: Han ley06ivembargmail.com <br />FOR GABLES OR HIP ROOFS VENTILATION SHALL BE <br />PROVIDED TO FURNISH CROSS VENTILATION OF EACH <br />SEPERATE ATTIC. THE RATIO OF TOTAL NET FREE <br />VENTILATING AREA TO THE AREA OF THE CEILING <br />SHALL BE NOT LESS THAN 1/150, <br />THE PLUMBING , ELECTRICAL AND MECHANICAL PARTS OF <br />THE PLAN ARE NON-STRUCTURAL AND MAY BE ADJUSTED <br />BY THE SUB -CONTRACTORS PERMITTED TO DO THE JOB. <br />BUT THE CHANGES MUST MEET THE MINIMUM STANDARDS OF <br />THE CURRENT FLORIDA BUILDING CODE. THESE CHANGES <br />ARE NOT REQUIRED TO BE VERIFIED BY THE ENGINEER OF <br />RECORD FOR THIS PLAN. <br />