My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6419 Simons Rd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6419 Simons Rd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 4:31:53 PM
Creation date
2/18/2025 4:03:33 PM
Metadata
Fields
Template:
Building Plans
Street #
6419
Location
Simons Rd
Contractor
Florida Low Voltage Systems
Building Plans - Permit #
3995
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE ALARM NOTES: <br />SEQUENCE OF OPERATION: <br />1. THE FIRE ALARM SYSTEM SHALL OPERATE AS FOLLOWS: <br />A. MANUAL PULL STATION: <br />1) IDENTIFY THE INDIVIDUAL STATION ON THE SYSTEM CONTROL PANEL <br />2 SOUND THE LOCAL AUDIBLE ALARM AT THE FACP. <br />3 ILLUMINATE THE ALARM RED LED. <br />4 SOUND AUDIBLE ALARM AND ACTUATE THE VISUAL ALARMS (STROBES) <br />IN THE BUILDING. <br />B. AN AREA SMOKE DETECTOR OR HEAT DETECTOR ,OR SPRINKLER WATER — <br />FLOW SWITCH SHALL CAUSE THE FOLLOWING: <br />1) IDENTIFY THE INDIVIDUAL DETECTOR ON THE SYSTEM CONTROL PANEL. <br />2 SOUND THE LOCAL AUDIBLE ALARM AT THE FACP. <br />3 ILLUMINATE THE ALARM RED LED. <br />4 SOUND AUDIBLE ALARM AND ACTUATE THE VISUAL ALARMS (STROBES) <br />IN THE BUILDING. <br />C. SMOKE DUCT DETECTORS <br />1) IDENTIFY THE INDIVIDUAL DETECTOR ON THE SYSTEM CONTROL PANEL <br />2 SOUND THE LOCAL AUDIBLE SUPERVISORY ALARM AT THE FACP. <br />3 ILLUMINATE THE SUPERVISORY LED. <br />4 SHUT DOWN ITS RESPECTIVE AIR HANDLER UNIT. <br />D. RECEIPT OF A TROUBLE SIGNAL AT THE FACP SHALL CAUSE THE <br />FOLLOWING ACTIONS AND INDICATIONS: <br />1) IDENTIFY THE ORIGIN OF THE TROUBLE ON THE SYSTEM CONTROL PANEL <br />2) SOUND THE LOCAL AUDIBLE TROUBLE SIGNAL AT THE FACP. <br />3 ILLUMINATE THE TROUBLE LED. <br />ALARMS, TROUBLES AND SUPERVISORY SIGNALS SHALL BE DISPLAYED ON <br />THE MAIN FIRE ALARM PANEL AS WELL AS ON ALL REMOTE ANNUNCIATOR PANELS. <br />ALARMS, TROUBLES AND SUPERVISORY SIGNALS SHALL BE TRANSMITTED TO <br />A LISTED CENTRAL STATION. <br />CENTRAL STATI❑N TRANSMISSI❑N ❑F SIGNALS <br />— ALL SIGNALS (ALARM/ TROUBLE/SUPERVISORY) WILL BE TRANSMITTED TO THE <br />CENTRAL STATION. <br />— THE MEANS OF TRANSMISSION WILL BE (2) DEDICATED PHONE LINES. <br />— ALL SIGNALS WILL BE TRANSMITTED AS FOLLOWS: <br />A POINT ADDRESSABLE SIGNAL WILL BE TRANSMITTED TO THE CENTRAL STATION, <br />SYSTEMS POINTS WILL BE IDENTIFY AT THE CENTRAL STATION AS FOLLOW - <br />DEVICE TYPE ( PULL STATION, SMOKE, ETC) + DEVICE LOCATION <br />(FLOOR + GENERAL DESCRIPTION) + INDIVIDUAL BUILDING PHYSICAL ADDRESS <br />OR BUILDING NUMBER. <br />— THE FIRE ALARM DIALER IS AN OPTIONAL BOARD THAT MOUNTS INSIDE <br />THE FIRE ALARM CABINET ON TOP OF THE FIRE ALARM MAIN BOARD. <br />CODES & PLAN NOTES <br />— INSTALLATION SHALL BE IN ACCORDANCE WITH FFPC 7TH Edition, NFPA 72 2016 Edition, <br />NFPA 70 2017 Edition, FBC 7th Edition 2020 AND ANY OTHER APPLICABLE CODES. <br />— ALL NEW SYSTEMS SHALL INCLUDE A DOCUMENT CABINET. <br />— ALL DRAWINGS ARE SCALED TO 1/8 = 1Ft UNLESS OTHERWISE NOTED. <br />— CONFIRM LOCATION OF POWER SUPPLY PRIOR TO ROUGH IN. <br />— REFER TO FLOOR PLANS FOR LOCATION OF DUCT DETECTORS (SUPPLY OR <br />RETURN SIDE), COORDINATE WITH MECHANICAL CONTRACTOR THE ACTUAL <br />LOCATIONS OF THE AHUs. <br />— ALL STROBES WILL BE SET @ 75cd UNLESS NOTED. <br />— CEILING HEIGHT IS 10ft UNLESS NOTED. <br />— FIRE ALARM SYSTEM PROVIDED IS FULLY ADDRESSABLE. <br />— COORDINATE WITH MECHANICAL CONTRACTOR LOCATION OF DUCT SMOKE DETECTORS <br />— ELECTRICAL LOAD, PANEL, BREAKER LOCKOUT IS ON SEPARATE PERMIT <br />PERMIT BY THE ELECTRICAL CONTRACTOR. FBC 107.2 <br />24/5 STANDBY TEST IS REQUIRED BEFORE FINAL FIRE. IF BUILDING IS OCCUPIED <br />DURING THIS TEST, FIREWATCH WILL BE REQUIRED. <br />CEILING MOUNTED <br />3' (MIN) <br />SMOKE/HEAT <br />PER NFPA 72 <br />4. <br />DE CTOR <br />24' MIN HANDICAP <br />A/C SUPPLY DIFFUSER / <br />ACCEPTABLE HERE <br />4" <br />BEDROOM STROBE <br />I <br />AUDIO/VISUAL <br />CEILING MOUNTED NOTIFICATION <br />ALL <br />D7DETECTO <br />12' (MAX) <br />VISUAL -ONLY <br />DEVICES DEVICE �TO BE WHITE). <br />EA <br />,j� <br />SEE PLAN OR LOCATION. <br />WAL <br />HEAT <br />TO THE BOTTOM. <br />WALL MOUNTED <br />MORE THAN TWO APPLIANCES <br />5'-0 <br />SMOKE DETECTO <br />IN THE SAME ROOM OR ADJACENT <br />MAX FROM EXIT DOOR <br />TO THE TOP. <br />SPACE WITHIN THE FIELD OF VIEW <br />SHALL FLASH IN SYNCHRONIZATION. <br />MANUAL �— <br />PULL <br />s <br />STATION <br />REMOTE <br />80' MIN <br />® g <br />ANNUNGATOR <br />96" MAX <br />NFPA 72 2013 <br />MAGNETC <br />D <br />HOLDER <br />(ADAAG) <br />80' ABOVE HIGHEST FLOOR <br />J <br />LEVEL OR 6' BELOW CEILING <br />Q ; <br />TO THE BOTTOM QU THE <br />x <br />STROBE. WHICHEVER IS LOWER. <br />48' (ADA) <br />a o <br />TO THE WORKING MECHANISM <br />Q <br />48" ALSO MEETS THE <br />REQUIREMENTS OF NFPA 72 2013 <br />FINISHED <br />FLOOR <br />IMPORTANT NOTE <br />NOTE <br />NOT ALL DEVICES % MN ON THIS DETAIL APPLY TO THIS PROJECT. SEE <br />CHECK WITH MANUFACTURE'S INSTALLATION SHEET <br />THE PLAN MEN LAYOUT OF THE Fff ALARM SYSTEM TO VEWY *1W <br />FOR THE EXACT ROUGH -IN HEIGHTS, LOCATION OF <br />DEVICES APPLY, AND *1CH DO NOT. <br />BACK BOXES, AND WIRING REQUIREMENTS. <br />FIRE ALARM DEVICE MOUNTING <br />GUIDE <br />LOW VOLTAGE WIRING <br />WHERE LOW VOLTAGE WIRING IS PERMITTED BY <br />THESE DRAWINGS AND APPROVED BY THE <br />LOCAL AUTHORITY HAVING JURISDICTION TO BE <br />FREE —WIRED, THESE WIRES SHALL BE PLENUM <br />RATED AND U.L. LISTED FOR THE APPLICATION. <br />FIRE ALARM SYMBOL LEGEND (TYPICAL) <br />NOT ALL DEVICES SHOWN ON THIS DETAIL APPLY TO THIS PROJECT. SEE THE PLAN VIEW <br />LAYOUT OF THE FIRE ALARM SYSTEM TO VERIFY WHICH DEVICES APPLY, AND WHICH DO NOT. <br />FRCP <br />FIRE ALARM CONTROL PANEL <br />ANN <br />FIRE ALARM ANNUNCIATOR <br />FCPSI <br />NAC POWER SUPPLY <br />FF-A-T-C-1 <br />FIRE ALARM TERMINAL CABINET <br />2 <br />ADDRESSABLE SMOKE PHOTO DETECTOR <br />t <br />ADDRESSABLE HEAT DETECTOR <br />�- <br />ADDRESSABLE DUCT SMOKE <br />ADDRESSABLE RELAY <br />ADDRESSABLE PULL STATION <br />Fs <br />ADDRESSABLE MONITOR MODULE FOR TAMPER SWITCH <br />FT S] <br />ADDRESSABLE MONITOR MODULE FOR FLOW SWITCH <br />HORN/STROBE WALL MOUNT <br />LF <br />LOW FREQUENCY/STROBE WALL MOUNT <br />LF <br />LOW FREQUENCY HORN WALL MOUNT <br />STROBE WALL MOUNT <br />FSDR <br />FIRE/SMOKE DAMPER RELAY <br />REVIEW DATE <br />CITY OF ZEPHYRHOLLS <br />FIRE AND LIFE SAFETY EXAMINE <br />ALL WORK SHALL COMPLY WITH <br />NFFA CODES AND STANDARDS <br />THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SAMUEL P <br />DEAN: P.E. ON [04.26.2022] USING A SHA-1 AUTHENTICATION CODE. <br />PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND <br />SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BE VERIFIED ON <br />ANY ELECTRONIC COPIES. <br />LST. 2027-A.00 <br />FLORIDA LOW VOLTAGE SYSTEMS <br />4020 W CAYUGA ST. <br />TAM PA, FL 33614 <br />813-353-0831 <br />EC 13010771 <br />EF 20001786 <br />r <br />L <br />M <br />CD <br />z <br />J <br />IL <br />O <br />to <br />cn <br />r� <br />L) <br />cl) <br />co <br />v 1' <br />uj <br />N <br />CAD DATE: 2/10/2022 <br />NO. ISSUE/REVISION DATE <br />0 <br />N 39 <br />S TA E L <br />11� <br />I <br />Y,L.,; <br />APR 2 6 2022 <br />SAMUEL P. DEAN P.E. <br />CONSULTING ENGINEER <br />REGISTRATION NUMBER 83915 <br />CA # 29694 <br />1503-A WEST BUSCH BLVD. <br />TAMPA FLORIDA 33612 <br />PHONE: (813) 961-3075 <br />FAX: (813) 961-1031 <br />email: sdean@beltengineering.com <br />I CERTIFY THAT TO THE BEST OF MY KNOWLEDGE <br />AND BELIEF ALL OF THE FIRE ALARM ELEMENTS <br />FOR THIS STRUCTURE HAVE BEEN DESIGNED TO <br />BE IN COMPLIANCE WITH THE FLORIDA BUILDING <br />CODE 7TH EDITION 2020. ALL OTHER ELEMENTS, <br />SYSTEMS AND ASSEMBLIES ARE THE TOTAL <br />RESPONSIBILITY OF OTHERS. <br />SHEET: <br />FA-1 <br />