TRUSS AND FRAMING NOTES: <br />1. TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE APPLICABLE <br />PROVISIONS OF THE "NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION" OF NFPA AND WITH THE TPI "DESIGN SPECIFICATION <br />FOR METAL PLATE CONNECTED WOOD TRUSSES". CHORD MEMBERS <br />SHALL BE K.D. SOUTHERN PINE, SURFACED DRY, NO.2 MINIMUM. <br />LIVE LOAD DEFLECTION SHALL BE LIMITED TO L/360. CONNECTOR <br />PLATES SHALL BE MADE OF ASTM A446, GRADE A, HOT -DIPPED <br />GALVANIZED (G60) STEEL AND APPLIED TO BOTH FACES OF TRUSS <br />AT EACH JOINT. TRUSSES WITH THREE SUPPORTS SHALL PROVIDE <br />FOR HORIZONTAL MOVEMENT AT ONE. <br />2. ROOF TRUSS SUPPLIER SHALL BE RESPONSIBLE FOR THE DESIGN OF <br />THE ROOF TRUSS SYSTEM. DESIGN OF THE SYSTEM SHALL BE PREPARED <br />SIGNED AND SEALED BY A QUALIFIED FLORIDA REGISTERED PROFESSIONAL ENGINEER. <br />COPIES OF COMPLETE SHOP DRAWINGS, INCLUDING TRUSS LAYOUT AND <br />BRACING, SHALL BE SUBMITTED FOR THE CONTRACTOR'S REVIEW. <br />DURATION FACTORS USED FOR DESIGN SHALL BE 1.25 FOR D+L AND <br />1.33 FOR D+W LOADS. SUBMITTALS SHALL INDICATE UPLIFT LOADS PER <br />PROJECT WIND SPEED AND DESIGN CRITERIA. <br />3. TRUSSES AND RAFTERS SHALL BE SECURED TO SUPPORTS WITH HURRICANE <br />ANCHORS AND 8d NAILS, MINIMUM. TRUSS TO TRUSS CONNECTORS SHALL <br />BE BY THE TRUSS FABRICATOR INCLUDING VALLEY TRUSSES. <br />4. TRUSSES SHALL BE SECURELY BRACED DURING ERECTION AND AFTER <br />PERMANENT INSTALLATION IN ACCORDANCE WITH "BRACING WOOD TRUSSES: <br />COMMENTARY AND RECOMMENDATIONS (BWT-85)" AS PUBLISHED BY TPI, AS <br />CALLED FOR BY THE TRUSS FABRICATOR AND AS SHOWN ON DRAWINGS. <br />CONSTRUCTION AND/OR PERMANENT LOADS SHALL BE PLACED ONLY ON <br />COMPLETED NAILED SHEATHING AND BRACING. <br />5. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL <br />BE PRESSURE TREATED, USING WOLMAN CC OR EQUIVALENT. <br />6. THE CONTRACTOR SHALL COORDINATE ALL ROOF PENETRATIONS, DUCT LAYOUT <br />AND OTHER CEILING WORK WITH TRUSS AND OTHER STRUCTURAL FRAMING. <br />7. ALL DOORS, WINDOWS AND STOREFRONT, THEIR FRAMES, FASTENERS AND ANCHORAGES <br />SHALL SATISFY THE 150 MPH WIND SPEED REQUIREMENTS OF RFBC 2010, CHAPTFER 3. <br />8. PATIO DOORS SHALL BE SAFTY GLAZED PER RFBC 2010, SECTION R 308.4. <br />ROOF SHEATHING (UNBLOCKED <br />USE 15/32" THICK APA RATED SHEATHING, 32/16, EXPOSURE <br />1 (OR 1 /2" OSB). USE PANEL CLIPS BETWEEN EACH SUPPORT. <br />MINIMUM NAILING OF PLYWOOD SHALL BE WITH 8d COMMON NAILS <br />AT 6" O.C. AT SUPPORTED EDGES. AT 12" O.C. ALONG <br />INTERMEDIATE SUPPORTS, NAILING SHALL BE 4" O.C. FOR PERIMITERS <br />AND HIPS, FOR A 5'-0" WIDTH. ( NO STAPLES ). <br />FLOOR SHEATHING, GLUE -NAILED SUB -FLOORING <br />USE 3/4" THICK APA RATED SHEATHING, 48/24, C-D, EXPOSURE I. PANELS <br />SHALL BE TONGUE AND GROOVE EDGES. NAILING SHALL BE 8d DEFORMED <br />NAILS ® 6" O.C. ALONG EDGES AND 12" O.C. AT INTERMEDIATE <br />SUPPORTS FOR GLUE -NAILED FLOORS. USE ADHESIVES CONFORMING TO APA <br />SPEC Y510J; NON -VENEERED PANELS WITH SANDED SURFACES AND EDGES <br />SHALL USE ONLY SOLVENT BASED GLUES. <br />WALL SHEATHING <br />EXTERIOR AND INTERIOR BEARING STUD WALL SHEATHING SHALL BE 15/32" <br />THICK APA RATED, EXPOSURE I OR 1 /2" OSB. NAILING OF PLYWOOD SHALL BE 8d NAILS <br />AT 6" O.C. AT EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS, U.O.N. <br />STRUCTURAL WOOD <br />1. LUMBER FOR STRUCTURAL FRAMING AND STUD WALLS SHALL BE SURFACED <br />® 15% M.C. MAX, KID, SOUTHERN YELLOW PINE MEETING OR EXCEEDING THE <br />FOLLOWING MINIMUM GRADES: <br />2X4 STUD WALLS - STUD GRADE <br />2X6 AND LARGER FRAMING - NO. 2 GRADE, Fb=1200 PSI, MIN. <br />4X4 POSTS - STUD GRADE <br />2. MINIMUM TWO-2X STUDS UNDER ALL CONCENTRATED LOADS. <br />3. ML = MICRO -LAM BEAMS BY "TRUSJOIST", GRADE Fb = 2925 PSI <br />OPEN WEBB 4X2 WOOD FLOOR TRUSSES, SHALL BE 16" DEEP BY <br />TRUSJOIST-MACILLAN WITH INSTALLATION IN ACCORDANCE WITH <br />RECOMMENDATIONS AND GUIDLINES OF THE VENDOR. PROVIDE STRUT <br />BRACING, BRIDGING AND BLOCKING AS REQUIRED OR SHOWN. SHOP DRAWINGS <br />SHALL BE SUBMITTED FOR THE ENGINEERS REVIEW. PERMANANT BRACING, <br />BRIDGING AND SHEATHING SHALL BE INSTALLED PRIOR TO FLOOR LOADS. <br />4. ALL FRAMING CONNECTIONS SHALL BE BASED ON (USP) LUMBER CONNECTORS. <br />NAILING REQUIEMENT LITERATURE. A CATALOG OF CONNECTORS SHALL BE <br />KEPT ON SITE AT ALL TIMES AND REFERED TO BY THE FRAMING <br />SUBCONTRACTOR. ALL NAILS AND CONNECTORS EXPOSED TO THE ATMOSPHERE <br />SHALL BE GALVANIZED. <br />5. PROVIDE WOOD FRAME SUPPORT AND ACCESS PLATFORM ABOVE BOTTOM TRUSS <br />CHORDS AS REQUIRED BY MECHANICAL CONTRACTOR. CONTRACTOR SHALL VERIFY <br />LOCATIONS AND PROVIDE ROOF TRUSS FABRICATOR WITH LOADS, INSTALLATION <br />DIMENSIONS AND CLEARANCE REQUIREMENTS NECESSARY FOR TRUSS DESIGN AND <br />MODIFICATIONS TO STANDARD TRUSSES. <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE = 2000 PSI <br />BUILDING SLAB AND FOOTING SUBGRADES INCLUDING ALL FILL SHALL BE COMPACTED <br />TO 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE <br />PER ASTM D-1557. SOIL SHALL BE GRANULAR MATERIAL CONTAINING LESS THAN <br />11% OF FINES PASSING A #200 SIEVE. DENSITY TESTING AT CONTRACTORS OPTION. <br />DESIGN CRITERIA AND STRUCTURAL NOTES <br />1. ALL WORK SHALL BE IN ACCORDANCE WITH THE RESIDENTIAL FLORIDA BUILDING <br />CODE 2010, LOCAL ORDINANCE AND REGULATIONS. <br />2. LIVE LOADS <br />ROOF = 30 PSF <br />FLOOR = 40 PSF <br />DEAD LOADS: <br />ROOF -TOP CHORDS = 7.5 PSF, BOTTOM CHORD = 10 PSF <br />FLOOR = 20 PSF <br />3. WIND LOADS: 150 MPH WIND SPEED = 25 PSF, BASIC <br />DESIGN PER RFBC 2010. <br />4. MATERIALS OF CONSTRUCTION AND NOTES <br />ALL CONCRETE TO BE IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS <br />FOR REINFORCED CONCRETE" (ACI 318-95). <br />ALL CONCRETE ------ f'c = 2,500 PSI, 5" SLUMP MAX, FILLED CELLS <br />2,500 PSI, "PEAROCK CONCRETE", 9" SLUMP MAX. USE WATER OR CURING <br />COMPOUND FOR SLAB -ON -GRADE AND PLACE NO CONSTRUCTION MATERIALS <br />THEREON UNTIL CONCRETE HAS REACHED 2/3 OF IT'S COMPRESSIVE STRENGTH. <br />CONCRETE TESTING AT CONTRACTOR'S OPTION. <br />ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI <br />AND SHALL CONFORM TO ASTM A-615. LAP SPLICE BARS 25 TIMES. <br />ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 82-02.. <br />MASONRY <br />1. HOLLOW REGULAR WEIGHT CONCRETE MASONRY UNITS EIGHT 8 INCHES AND OVER <br />IN WIDTH SHALL CONFORM TO STANDARD SPECIFICATIONS FOR HOLLOW LOAD - <br />BEARING CONCRETE MASONRY UNITS, GRADE N-II CONFORMING TO ASTM C90-03, <br />WITH A 28 DAY COMPRESSIVE STRENGTH OF NOT LESS THAN 1,500 PSI, f'm <br />(net section area). <br />2. BRACE HOUSE WALLS UNTIL FILL AND CONCRETE FLOOR SLAB ARE INSTALLED. <br />3. MORTAR MIXES SHALL MEET ASTM C-270-04, PROPORTION PER THE FOLLOWING TYPES: <br />TYPE S (1,800 PSI) OR M (2,500 PSI). <br />4. CELLS CONTAINING VERTICAL REINFORCING BARS SHALL BE FILLED WITH 'PEAROCK" <br />CONCRETE AT A 28 DAY COMPRESSIVE STRENGTH OF 2,500 PSI AND CONTAINING <br />NOT LESS THAN 5 BAGS OF CEMENT PER CUBIC YARD AND A SLUMP OF <br />9 INCHES MAXIMUM. <br />NOTE: VARIOUS ITEMS WITHIN THE GENERAL <br />NOTES DO NOT APPLY TO THIS PROJECT. <br />GARDEN VILLAS <br />FOR <br />GARDEN VILLAS, LLC <br />38070DAUGHTERYROAD <br />ZEPHYRHILLS, FLORIDA 33540 <br />SECTION 2, TO u�NSHIP 2 6S, RANGE 21 E <br />LOCATION MAP <br />Nrs <br />�Qq"coo"�v <br />UTILITY COMPANIES: <br />TELEPHONE: <br />VERIZON <br />27835 WESLEY CHAPEL BLVD. <br />SUITE 100 <br />WESLEY CHAPEL, FLORIDA <br />813-907-8511 <br />CABLE: <br />BRIGHT HOUSE NETWORK <br />CONSTRUCTION DEPARTMENT <br />2728 S. FALKENBURG ROAD <br />ZEPHYRHILLS, FLORIDA 33539 <br />813- 788- 7634 <br />ELECTIRC: <br />DUKE ENERGY <br />36906 EILAND BLVD. <br />ZEPHYRHILLS, FLORIDA 33539 <br />813- 782- 7237 <br />OV3 (q/0 <br />�P <br />.7LILIJP <br />ALL WORK SHALL COMPLY WIT11 X11NG � � <br />CoDES. TLORIDABl)IL <br />PREVAILINC <br />CODE. N �� 1DN' At. ELECTRIC CODE AND <br />CITY OF ZE.P�iVV--'S ORDiNpNCES <br />OWNER: GARDEN VILLAS, LLC <br />38070 DA UGHTERY ROAD <br />ZEPHYRHILLS, FLORIDA 33540 <br />CONTRACTOR: TO BE DETERMINED <br />SURVEYOR: TO BE DETERMINED <br />REVIEW UK I✓--I,-- <br />CITY OF ZEPHYRHILLS <br />PLANS EXAMINER <br />BEFORE DIGGING CALL <br />SUNSHINE STATE ONE -CALL OF FLA <br />1-800-432-4770 <br />FSS 93,240, SECTI❑NS 556.101-556,111 <br />REQUIRES MIN. OF 2 DAYS AND MAX. OF <br />5 DAYS NOTICE BEFORE YOU EXCAVATE, <br />3,% <br />WA TER: <br />CITY OF ZEPHYRHILLS <br />5335 8th STREET <br />ZEPHYRHILLS, FLORIDA 33542 <br />813- 780- 0008 <br />ATTN.- JOHN BOSTIC <br />WASTE WA TER: <br />CITY OF ZEPHYRHILLS <br />39825 ALSOTN AVENUE <br />ZEPHYRHILLS, FLORIDA 33542 <br />813- 780-0029 <br />ATTN.- JOHN BOSTIC <br />DRA WING INDEX <br />1. <br />SITE PLAN, NOTES AND DRAWING INDEX <br />� 2. <br />SURVEY PLAN <br />3. <br />SITE PLAN WITH PHASES <br />4. <br />MODEL <br />CENTER FLOOR PLANS <br />5. <br />MODEL <br />CENTER FL 0 OR PLANS UNITS 7-9 <br />6. <br />MODEL <br />CENTER ELEVA TIONS <br />7. <br />MODEL <br />CENTER ELEVATIONS <br />8. <br />MODEL <br />CENTER FOUNDATION PLAN <br />9. <br />MODEL <br />CENTER PLUMBING PLAN <br />10. <br />MODEL <br />CENTER ELECTRIC PLAN <br />11. <br />MODEL <br />CENTER MECHANICAL PLAN <br />12. <br />MODEL <br />CENTER TRUSS PLAN <br />13. <br />CONCRETE DETAILS <br />14. <br />WOOD DETAILS <br />15. <br />FLOOR <br />PLAN BUILDINGS 1-6 <br />16. <br />FL 0 OR <br />PLAN BUILDINGS 10-16 <br />DO NOT SCALE DRAWINGS <br />The contractor shall verify all plans and existing dimensions <br />and conditions on the job site and shall immediately notify <br />the engineer in writing of any discrepancies before <br />proceeding with the work or be responsible for some. <br />Emails: rroberts.egi®gmail.com troutwein-clem®outlook.com <br />I HEREBY CERTIFY: <br />THAT THE CONSTRUCTION PLANS SHOWN ARE IN COMPLIA CE <br />WITH CHAPTER 16, SECTION 1609 OF THE 2010 FLORIDA ILDIP <br />FOR 150 MPH ULTIMATE DESIGN WIND SPEEII,� (RISK C TEGO <br />ALONG WITH THE ENTIRE 2010 FLORIDA BUILDING COVEN RESIDENT L. <br />EGI-ENGINEERING GREAT IDEAS, LLC <br />William H Roberts P E <br />C10 <br />Cr <br />O <br />q <br />h <br />a <br />.■■.■■■■■ <br />■.■■.■■■■ <br />:: <br />_ME <br />, <br />i <br />i <br />• _ <br />• - <br />_ <br />' <br />ME <br />IN <br />■■ <br />■■ <br />■■ <br />■■ <br />.■ <br />■■ <br />■■ <br />IN <br />■■ <br />■■ <br />.■ <br />■■ <br />.■ <br />■■ <br />■■ <br />■■ <br />■■ <br />ME <br />ME <br />ME <br />M■ <br />■■ <br />.■ <br />IN <br />ME <br />ME <br />■N <br />EM <br />■M <br />ME <br />ME <br />ME <br />MIMMMMMMM <br />■■■■...■■ <br />- ' <br />11M <br />I <br />.10 <br />IN <br />�IN <br />.I <br />'■ <br />■ <br />'■ <br />IN <br />101 <br />011 <br />101 <br />IN <br />■■■■■■■■■ <br />i <br />DRAWN <br />CLEM TRAUTWEIN <br />NTS <br />:ODE CHECKED do APPROVED <br />II) <br />CET 4-20-15 <br />1906 W. Thonotosassa Road ! , <br />Suite 2 / <br />Plant City, Florida 33563 <br />P.E. #42712 4-28-15 <br />TEL (813) 752-7078 DATE <br />CA #29098 (NOT VALID WITHOUT FOR SEAL OR STAMP) <br />C 145 74A <br />SHEET OF 16 <br />