Laserfiche WebLink
I P -- 1 I -- -I - <br />11 11 T9111' 1 <br />INTERIOR UNIT <br />1.5" FIBERGLASS SUPPLY DUCT R-6 <br />CROWN SPIN -IN FITTING <br />WITH DAMPER <br />i <br />ROUND METAL DUCT R-6 <br />(EXTERNAL INSULATION) <br />CEILING <br />INSULATED ROUND R-6 <br />FLEXIBLE DUCT <br />(MAX. 10'-0" LONG) <br />ATTACH WITH <br />PANDUIT STRAP 6 TAPE PER CODE <br />PRE -INSULATED TITUS <br />2x2 SUPPLY DIFFUSER <br />CEILING DIFFUSER <br />CEILING DIFFUSER RUNOUT DETAIL <br />NOT TO SCALE <br />INTERIOR UNITS - HVAC NOTES <br />DETAILS AND SCHEDULES <br />SYSTEM DESCRIPTION" 2.0 Ton Split System With Heat Pump <br />EQUIPMENT SCHEDULE: GOODMAN <br />15 SEER HEAT PUMP SYSTEM with "R-41OA" Refrigerant <br />CU MD #RQPL-B048-JK010AA Heat Pump <br />BTUH COOLING CAPACITY 24,000 SEER 15.00 HSPF 7.8 <br />BTUH HEATING CAPACITY 24,000 <br />BLOWER SPEED CFM ® .3" WC Cooling 800 Heating 800 <br />ELECTRICAL REQUIREMENTS <br />CU-1 MCA 35 MOCP 60 AMPS VOLTS 120 240 1 60 <br />AH-1 MINIMUM AAPACITY 28.4 MAX FUSE 40 AMPS <br />PIPING SIZE 3 8" LIQUID 1 1 8" SUCTION w 1 2" INSULATION <br />3 4" CONDENSATE DRAIN <br />CONTROLS: Programmable Thermostat <br />FILTER TYPE: 1" pleated throw -a -ways <br />DUCT SYSTEM: R-6 fiberglass/foil-flex w/Crown #1580 register boxes, <br />damper collars, and Air Mate grilles. All joints sealed with Fasson #0801 <br />pressure sensitive tape. <br />All work shall conform to the requirements of the Current Florida Unified <br />Mechanical Code, 2008 National Electrical Code, and all Pasco <br />Country Codes. <br />Note: General Contractor has the option of utilizing an Equivalent Manufacturers HVAC <br />Package Heat Pump System. <br />GENERAL A/C NOTES: <br />1. PLANS INDICATE THE GENERAL LAYOUT AND LOCATION OF THE MECHANICAL SYSTEM COMPONENTS. <br />UNLESS SPECIFIED DIMENSIONS ARE NOTED, THE ACTUAL LOCATION OF THOSE COMPONENTS SHALL BE <br />DETERMINED IN THE FIELD IN COORDINATION WITH THE WORK OF OTHER TRADES, THE USE OF <br />MANUFACTURER'S SHOP DRAWINGS AND SIMILAR CERTIFIED DATA. <br />2. CONSTRUCTION SHALL COMPLY WITH LOCAL BUILDING CODES ADOPTED AT THE TIME OF PERMIT <br />APPLICATION AND THE 2010 FLORIDA UNIFIED BUILDING CODE, FLORIDA MECHANICAL AND <br />ENERGY CODES. <br />3. SUBMIT SHOP DRAWINGS OF ALL EQUIPMENT AND MATERIAL FOR REVIEW. INSTALL AND TEST ALL <br />EQUIPMENT AND MATERIAL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. <br />4. DUCTWORK, AIR DEVICES AND OTHER ITEMS OF THE AIR DISTRIBUTION SYSTEM SHALL BE SUPPORTED <br />DIRECTLY FROM THE BUILDING STRUCTURE AND NOT TO THE CEILING OR CEILING SUSPENSION SYSTEM. <br />COORDINATE LOCATION OF ALL AIR DEVICES, WALL CAPS, ROOF CAPS AND LOUVERS WITH ELECTRICAL, <br />ARCHITECTURAL AND PLUMBING WORK. <br />5. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF <br />"SMACNA" DUCT CONSTRUCTION STANDARDS AND COMPLY WITH THE LATEST "NFPA" 90A REQUIREMENTS. <br />6. ALL DUCT DIMENSION AS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE DIMENSIONS. ADD 3" FOR <br />EXTERIOR DUCT DIMENSIONS. <br />7. ALL FLEXIBLE DUCT SHALL BE CLASS 1 R-6 INSULATED REINFORCED METAUZED JACKET, AIR -TIGHT, <br />INNER CORE, WITH ENCAPSULATED WIRE HELIX. <br />8. ALL WALL MOUNTED THERMOSTATS SHALL BE INSTALLED AT A CENTER LINE ELEVATION OF 54" ABOVE <br />FINISHED FLOOR UNLESS NOTED ON DRAWINGS. LOCATION OF THERMOSTAT SHALL BE COORDINATED WITH <br />OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF THE THERMOSTAT SHALL BE SUBJECT TO <br />APPROVAL OF THE ARCHITECT OR HIS REPRESENTATIVE IN THE FIELD. <br />9. PROVIDE A CONDENSATE DRAIN SYSTEM PER THE 2001 FLORIDA MECHANICAL CODE SECTION 307. <br />a. PROVIDE P-TRAPS AT ALL CONDENSATE DRAIN LINES. SLOPE DRAIN LINES TOWARD THE POINT OF DISCHARGE. <br />b. (MINIMUM 1 /8" PER FOOT). INSULATE DRAIN LINES WITH 1 /2" THICK CLOSED CELL <br />RUBBER PIPE INSULATION. <br />c. CONDENSATE LINES TO BE PVC. LINES TO BE A MINIMUM OF 3/4" diameter. <br />EXTEND TERMINATION OF DRAINS 12" FROM THE EXTERIOR WALL TO GREEN AREA. <br />10. PROVIDE REINFORCED CONCRETE EQUIPMENT PADS FOR THE CONDENSINIG UNITS. PADS TO BE SIZED <br />AND SPACED TO PROVIDE MANUFACTURER'S REQUIRED SERVICE CLEARANCES. <br />Elements of Load <br />Insulation / R-value <br />Area lin.ft. <br />U-Value I Heat Loss <br />Heat Gain <br />Gross Wall <br />1580 <br />GLASS Solar Gain <br />2093 <br />Glass 1 <br />Single <br />48 <br />0.42 <br />487 <br />Glass 2 <br />Select <br />0 <br />Skylight <br />Select <br />0 <br />Doors <br />Insulated or Storm <br />40 <br />0.4 <br />384 <br />368 <br />Net Walls <br />R-5 <br />1492 <br />0.06 <br />2148 <br />2059 <br />Ceilings <br />R-30 <br />929 <br />0.033 <br />736 <br />1380 <br />Floors <br />Select <br />0 <br />0 <br />Open Floors <br />Select <br />0 <br />0 <br />Slab Floors <br />No Insulation <br />929 <br />0.8 <br />17,837 <br />0 <br />Volume of your Building or Zone (cu.ft.) <br />18,084 <br />3208 <br />1384 <br />VARIFS <br />TYPICAL A& SLAB <br />People <br />750 <br />Appliances <br />3000 <br />Sub Total <br />24,800 <br />14,426 <br />Duct Loss Gain <br />2658 <br />4411 <br />Sensible Load <br />27,457 <br />18,837 <br />Latent Load <br />1843 <br />TOTAL BTUH <br />27,457 <br />20,680 <br />SLAB TO BE 4" <br />WIDER THEN THE <br />UNIT. <br />LEGEND: <br />SumMary <br />BTUH <br />Tons <br />Total Heating Load <br />27,457 <br />Total Cooling Load <br />20,680 <br />1.7 <br />206 crm 10"X10" SUPPLY AIR GRILL <br />AND AIR FLOW CFM <br />80 CFM 6"X1O" SUPPLY AIR GRILL <br />AND AIR FLOW CFM <br />10"4 <br />�- SUPPLY AIR DUCT (R-6) <br />AND DUCT SIZE <br />12"X14" <br />- - - RETURN AIR DUCT (R-6) <br />AND DUCT SIZE <br />® 24"SQ. RETURN AIR GRILLE <br />A/C AREA = 929 S.F. <br />END UNIT <br />HVAC NOTES <br />1 All equipment is new, air handlers located on steel channell, supported from deck above with concrete deck anchors. <br />Bottom of plenum box of return held 2" off bottom of stand with emergency condensate drain pan extending out 3" on all <br />four sides with emergency overflow shut down switch on condensate overflow mounted on emergency part <br />2. Rectangular ductwork to be 1.5" fiberous ductboard, Joints to be sealed with pressure sensitive "UL" 181 silver tape and <br />staples as recommended by manufacuterer. Round ductwork to be R-6 flex duct using silver tape, "UL" 181 and nylon panduit <br />straps at Crown dampened collar. <br />3. All duct sizes are clear inside dimensions, allow for 1.5" R-6 fiberglass ductwork <br />4. Rectangular ductwork to be hung with 2" u-channel 6 minimum 12-gauge wire on 6' centers and flex duct to be hung with 2" <br />metal strap on 5' centers and at elbow down to air distribution as needed. All duct materials and installation of same to comply <br />with section 503 of Florida Energy code for Building Construction effective March 1, 2002. <br />5. Smoke detectors shall be installed in return duct to shut down system, located prior to introduction of ventilation outside air. <br />6. Coordinate location of air distribution with ceiling grid and lights. <br />7. Contractor test and balance of systems to within 10% of design airflows shown and submit air balance report and equipment <br />performance to owner upon completion. <br />8. Thermostats to be mounted at 52" AFF. <br />CONC. <br />SLAB <br />'CONNECT <br />END UNITS - HVAC NOTES <br />DETAILS AND SCHEDULES <br />SYSTEM DESCRIPTION" 2.0 Ton Split System With Heat Pump <br />EQUIPMENT SCHEDULE: GOODMAN <br />15 SEER HEAT PUMP SYSTEM with "R-410A" Refrigerant <br />CU MD #RQPL-B048-JK010AA Heat Pump <br />BTUH COOLING CAPACITY 24,000 SEER 15.00 HSPF 7.8 <br />BTUH HEATING CAPACITY 24,000 <br />BLOWER SPEED CFM ® .3" WC Cooling 800 Heating 800 <br />ELECTRICAL REQUIREMENTS <br />CU-1 MCA 35 MOCP 60 AMPS VOLTS 120 240 1 60 <br />AH-1 MINIMUM AAPACITY 28.4 MAX FUSE 40 AMPS <br />PIPING SIZE 3 8" LIQUID 1 1 8" SUCTION wl 1 2" INSULATION <br />3 4" CONDENSATE DRAIN <br />CONTROLS: Programmable Thermostat <br />FILTER TYPE: 1" pleated throw -a -ways <br />DUCT SYSTEM: R-6 fiberglass/foil-flex w/Crown #1580 register boxes, <br />damper collars, and Air Mate grilles. All joints sealed with Fasson #0801 <br />pressure sensitive tape. <br />All work shall conform to the requirements of the Current Florida Unified <br />Mechanical Code, 2008 National Electrical Code, and all Pasco <br />Country Codes. <br />Note: General Contractor has the option of utilizing an Equivalent Manufacturers HVAC <br />Package Heat Pump System. <br />GENERAL A/C NOTES: <br />1. PLANS INDICATE THE GENERAL LAYOUT AND LOCATION OF THE MECHANICAL SYSTEM COMPONENTS. <br />UNLESS SPECIFIED DIMENSIONS ARE NOTED, THE ACTUAL LOCATION OF THOSE COMPONENTS SHALL BE <br />DETERMINED IN THE FIELD IN COORDINATION WITH THE WORK OF OTHER TRADES, THE USE OF <br />MANUFACTURER'S SHOP DRAWINGS AND SIMILAR CERTIFIED DATA. <br />2. CONSTRUCTION SHALL COMPLY WITH LOCAL BUILDING CODES ADOPTED AT THE TIME OF PERMIT <br />APPLICATION AND THE 2010 FLORIDA UNIFIED BUILDING CODE, FLORIDA MECHANICAL AND <br />ENERGY CODES. <br />3. SUBMIT SHOP DRAWINGS OF ALL EQUIPMENT AND MATERIAL FOR REVIEW. INSTALL AND TEST ALL <br />EQUIPMENT AND MATERIAL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. <br />4. DUCTWORK, AIR DEVICES AND OTHER ITEMS OF THE AIR DISTRIBUTION SYSTEM SHALL BE SUPPORTED <br />DIRECTLY FROM THE BUILDING STRUCTURE AND NOT TO THE CEILING OR CEILING SUSPENSION SYSTEM. <br />COORDINATE LOCATION OF ALL AIR DEVICES, WALL CAPS, ROOF CAPS AND LOUVERS WITH ELECTRICAL, <br />ARCHITECTURAL AND PLUMBING WORK. <br />5. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF <br />"SMACNA" DUCT CONSTRUCTION STANDARDS AND COMPLY WITH THE LATEST "NFPA" 90A REQUIREMENTS. <br />6. ALL DUCT DIMENSION AS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE DIMENSIONS. ADD 3" FOR <br />EXTERIOR DUCT DIMENSIONS. <br />7. ALL FLEXIBLE DUCT SHALL BE CLASS 1 R-6 INSULATED REINFORCED METALIZED JACKET, AIR -TIGHT, <br />INNER CORE, WITH ENCAPSULATED WIRE HELIX. <br />8. ALL WALL MOUNTED THERMOSTATS SHALL BE INSTALLED AT A CENTER LINE ELEVATION OF 54" ABOVE <br />FINISHED FLOOR UNLESS NOTED ON DRAWINGS. LOCATION OF THERMOSTAT SHALL BE COORDINATED WITH <br />OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF THE THERMOSTAT SHALL BE SUBJECT TO <br />APPROVAL OF THE ARCHITECT OR HIS REPRESENTATIVE IN THE FIELD. <br />9. PROVIDE A CONDENSATE DRAIN SYSTEM PER THE 2001 FLORIDA MECHANICAL CODE SECTION 307. <br />a. PROVIDE P-TRAPS AT ALL CONDENSATE DRAIN LINES. SLOPE DRAIN LINES TOWARD THE POINT OF DISCHARGE. <br />b. (MINIMUM 1/8" PER FOOT). INSULATE DRAIN LINES WITH 1/2" THICK CLOSED CELL <br />RUBBER PIPE INSULATION. <br />c. CONDENSATE LINES TO BE PVC. LINES TO BE A MINIMUM OF 3/4" diameter. <br />EXTEND TERMINATION OF DRAINS 12" FROM THE EXTERIOR WALL TO GREEN AREA. <br />10. PROVIDE REINFORCED CONCRETE EQUIPMENT PADS FOR THE CONDENSINIG UNITS. PADS TO BE SIZED <br />AND SPACED TO PROVIDE MANUFACTURER'S REQUIRED SERVICE CLEARANCES. <br />Elements of Load <br />Insulation / R-Value <br />Area/lin.ft. <br />U-Value I Heat Loss <br />Heat Gain <br />Gross Wall <br />1593 <br />GLASS Solar Gain <br />3477 <br />Glass 1 <br />Single <br />64 <br />0.42 <br />649 <br />Glass 2 <br />Select <br />0.06 <br />0 <br />Skylight <br />Select <br />0 <br />Doors <br />Insulated or Storm <br />40 <br />0.4 <br />384 <br />1 368 <br />Net Walls <br />R-19 <br />1489 <br />0.06 <br />2144 <br />2054 <br />Ceilings <br />R-30 <br />994 <br />0.033 <br />787 <br />1476 <br />Floors <br />Select <br />0 <br />0 <br />Open Floors <br />Select <br />0 <br />0 <br />Slab Floors <br />No Insulation <br />994 <br />0.8 <br />19,085 <br />0 <br />Volume of your Building or Zone (cu.ft.) <br />9,277 <br />3432 <br />1480 <br />VARIES <br />_ <br />People <br />750 <br />Appliances <br />3000 <br />Sub Total <br />26,481 <br />15,999 <br />Duct Loss Gain <br />2907 <br />4954 <br />Sensible Load <br />29,368 <br />20,953 <br />Latent Load <br />1939 <br />TOTAL BTUH <br />29,388 <br />22,893 <br />TYPICAL ABC SLAB <br />SLAB TO BE 4" <br />WIDER THEN THE <br />UNIT. <br />I C/%CAIrI. <br />Tot,fl Cooling Load <br />2a10"X10" SUPPLY AIR GRILL <br />AND AIR FLOW CFM <br />SUPPLY AIR GRILL <br />AND AIR FLOW CFM <br />0 0 SUPPLY AIR DUCT (R-6) <br />AND DUCT SIZE <br />12"X14" <br />- - - RETURN AIR DUCT (R-6) <br />AND DUCT SIZE <br />® RETURN AIR GRILLE <br />A/C AREA = 994 S.F. <br />DO NOT SCALE DRAWINGS <br />The contractor shall verify all plans and existing dimensions <br />and conditions on the job site and shall immediately notify <br />the engineer in writing of any discrepancies before <br />proceeding with the work or be responsible for same. <br />Emails: rroberts.egi©gmail.com trautwein_clem@outlook.com <br />1 HEREBY CERTIFY: <br />THAT THE CONSTRUCTION PLANS SHOWN ARE IN COMPLIANC <br />WITH CHAPTER 16, SECTION 1609 OF THE 2010 FLORIDA B D E <br />FOR 150 MPH ULTIMATE DESIGN WIND SPEED (RISK C E ) <br />ALONG WITH THE ENTIRE 2010 FLORIDA BUILDING CODE, RESIDEN <br />EGI-ENGINEERING GREAT IDEAS, LLC <br />William H. Roberts, P.E. <br />1906 W. Thonotosassa Road <br />Suite 2 ? <br />Plant City, Florida 33563 <br />P.E. #42712 <br />TEL (813) 752-7078 DATE <br />CA #29098 (NOT VALID WITHOUT FOR SEAL OR STAMP) <br />0 <br />w <br />�� <br />2 <br />b <br />U <br />0 <br />q <br />h <br />x <br />a <br />■■■■■■■, <br />.■■■■■■■■ <br />■■■■■MIME■ <br />■■ <br />• <br />:: <br />• <br />: <br />, _ <br />- <br />_ <br />_ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />�■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />no <br />■■ <br />■■ <br />■■ <br />no <br />■■■■■■■■■ <br />,�rl <br />� <br />• <br />_ <br />��_.� <br />I� <br />■1 <br />IN <br />■I <br />'■ III <br />■� <br />'■ <br />■ <br />1■ <br />■ <br />IN <br />■� <br />IN <br />MIL------�■' <br />1 <br />J <br />DRAWN <br />CLEM TRAUTWEIN <br />SCAM- <br />1/4" = 1'-0" <br />CHECKED & APPROVED <br />CET 4-20-15 <br />C 145 74A <br />SHEET 1OF 16 <br />