Laserfiche WebLink
GENERAL NOTES AND SPECIFICATIONS <br />1. Unless otherwise noted on the plans, all construction <br />methods, workmanship, materials and testing shall conform to <br />the "Florida Department of Transportation (FDOT)'s "Standard <br />Specification for Road and Bridge Construction", its current <br />supplements and standard index drawings, and any county, <br />COUNTY, or any other agency's rules and regulations. <br />2. Survey layout and testing shall be by the Contractor. <br />3. All work within the right-of-way shall be coordinated <br />with the CITY, County, and/or FDOT. All disturbed areas <br />within the right-of-way shall be restored to the <br />original condition or better in accordance with <br />county, and/or FDOT standards. <br />4. Locations, elevations and dimensions of existing <br />utilities, structures, and other features are shown <br />according to the best information available at the time <br />of preparation of these plans. The contractor shall <br />verify the locations, elevations and dimensions of <br />existing utilities, structures and other features <br />affecting this work prior to construction. <br />5. The contractor shall use extreme caution in areas of <br />buried utilities and shall provide at least 48 hours <br />notice to the utility companies prior to construction <br />to obtain field locations of existing underground <br />utilities. The contractor shall protect and maintain <br />operation of existing utilities during construction. <br />6. The contractor shall check plans for conflicts and <br />discrepancies prior to construction. The contractor <br />shall notify the engineer of any conflicts before <br />performing any work in the affected area. <br />7. The Engineer shall be notified as to where existing <br />utility services interfere with the proposed construction. <br />8. The Contractor is responsible for repairing any damage <br />to existing facilities, above or below ground, that may <br />occur as a result of the work performed by the contractor. <br />9. All underground utilities must be in place and tested <br />or inspected prior to base and surface construction. <br />10. Utilities installation shall conform to the requirements <br />of the applicable federal, state and local regulations <br />including but not limited to the Florida Department of <br />Environmental Protection (FDEP), Department of Health <br />(DOH), the Occupational Safety and Health Administration <br />(OSHA) Standard, COUNTY AND THE CITY. <br />11. It is the contractor's responsibility to become familiar <br />with the permit and inspection requirements specified <br />by the various governmental agencies and the engineer <br />The contractor shall obtain all necessary permits prior <br />to construction and schedule inspections according to <br />agency instructions. All work performed shall comply with <br />the regulations and ordinances of the various governmental <br />agencies having jurisdiction over the work. <br />12. At least three (3) working days prior to construction, <br />the contractor shall notify the engineer and appropriate <br />agencies and supply them with the contractor's name, <br />starting date, projected construction schedule, all required <br />shop drawings and other information as required. Any work <br />performed prior to proper notifications may be subject to <br />removal and replacement at the contractor's expense. <br />13. The site shall be initially graded such that no offsite <br />area will be adversely affected by storm water runoff. <br />Runoff to the adjacent right-of-way shall be minimized. The <br />existing drainage facilities within the right-of-way shall <br />be protected at all times by the use of staked hay bales, <br />temporary grading, revegetation, etc. Any disturbed area <br />within the right-of-way shall be sodded. The contractor <br />shall final grade and hand rake all exposed earthwork areas <br />immediately prior to installation of sod. All areas shall be <br />protected from erosion caused by storm water runoff by <br />vegetation, staked hay bales, temporary grading, etc. <br />14. Upon completion of construction activities, the storm <br />water management system shall be cleaned of all debris, <br />silts, limerock, etc. <br />15. The contractor shall verify minimum separation between <br />water and sanitary sewer systems (18" minimum vertical and <br />10' minimum horizontal separations). Upon completion of <br />construction, the contractor shall provide written <br />verification documenting the minimum separation as <br />constructed. <br />16. Typical cover over utilities shall be 36". <br />17. During construction and/or maintenance of this project, <br />all safety regulations are to be enforced. The contractor <br />or his representative shall be responsible for the control <br />and safety of the traveling public and the safety of his <br />personnel. <br />18. The contractor shall comply with all Federal/State <br />Occupational Safety and Health Act (OSHA) Standards and any <br />other rules and regulations applicable to construction <br />and/or maintenance activities in the State of Florida. The <br />Contractor shall also comply with Chapter 442, Florida <br />Statutes (Toxic Substances in the Workplace), and any <br />CITY, COUNTY, or any other agency's rules and regulations <br />regarding safety. <br />19. All trenching and excavation operations MUST conform to <br />the requirements stated in the new "Trench Safety Act" <br />incorporated into OSHA standards 29 CFR 1926 Subpart P final <br />rule and the State of Florida Trench Safety Act. The <br />contractor shall recognize the OSHA safety standards, agree <br />to abide by them, and identify the cost to comply. <br />20. Further Contractor operations shall comply with 29CFR <br />1910.252 and NFPA 51 B for cutting and welding procedures. <br />21. All persons on (CITY, COUNTY OR STATE) property and <br />in area where the noise level exceeds 85db, must <br />wear hearing protection that complies with ANSI S3.19-74 <br />(ear muffs and/or approved ear plugs). This includes areas <br />where noisy equipment is in use (i.e. jack hammers, electric <br />or air drills, heavy equipment with open cabs, pipe cutting <br />saws, etc.) and in the plant where posted. <br />22. All work conducted in an elevated position shall comply <br />with 29CFR 1910.269. <br />23. All design application, installation, maintenance, removal <br />of all traffic control devices, warning devices and barriers <br />necessary to protect the public and workmen from hazards <br />within the projects shall be in accordance with the minimum <br />standards as set forth in the current edition of the State <br />of Florida and Traffic Design Standards. <br />24. All traffic control markings and devices shall conform <br />to the provision set forth in the "Manual on Uniform <br />Traffic Control Devices" prepared by the U.S. Department of <br />Transportation, Federal Highway Administration. <br />25. All Contractor owned or controlled vehicles and/or <br />equipment which will be operated on or within ten (10) feet <br />of the roadway shall be equipped with a minimum of one amber <br />360 degree Class I warning device. This device must meet <br />minimum standards for utility construction purposes, such as <br />a minimum of 500,000 candlepower and visible from 360 <br />degrees of mounting. The warning device(s) must be in <br />operation at all times that a vehicle/equipment if on the <br />roadway or within the ten (10) feet of runoff area and not <br />in a "normal" travel status. <br />26. Area designated by the Owner shall be utilized for <br />equipment storage and cover material staging. Materials and <br />supplies shall be stored only in those areas approved by the <br />owner. <br />27. In regard to the inspection of the project, Southwest <br />Florida Water Management District (SWFWMD) and the COUNTY <br />inspectors shall have the same right of review and <br />inspection as the Engineer of Record. Although it is <br />appropriate for the Engineer of Record to resolve questions, <br />difficulties, and disputes relative to interpretation of <br />contract documents or construction; SWFWMD, COUNTY AND CITY <br />reserve the right of final concurrence on such matters. <br />28. The CITY, County, and/or State's Engineering inspector <br />shall be notified, and the Engineer's approval shall be <br />obtained, on all proposed field changes, alterations or <br />additions to the approved plans by the Contractor or <br />the Engineer of Record prior to the implementation of such <br />changes, alterations or additions. <br />Upon completion of construction, the Owner will require <br />one set of complete "As -Built". Contractor to supply <br />certified "As -Built" to the Engineer of Record. <br />29. The contractor shall obtain a separate permit for <br />any on -site burning. <br />30. If during construction activities any evidence of historic <br />resources including but not limited to aboriginal or <br />historic pottery, prehistoric stone tools, bone or shell <br />tools, historic trash pits, or historic building foundation, <br />are discovered, work shall come to an immediate stop <br />and the Florida Department of Historic Resources (State <br />Historic Preservation Officer) and Pasco County shall <br />be notified within two working days of the resources <br />found on the site. <br />31. All proposed signs must be applied for, approved and <br />permitted on an individual basis apart from ultimately <br />approved site plan. Approval of this site plan does <br />not constitute approval of any signage. <br />32. Handicap parking spaces will be properly signed and <br />and striped inaccordance with Florida Statute 316, the <br />Manual on Uniform Traffic Control Devices, or other <br />applicable standards. <br />33. The Engineer certifies that the site has been designed <br />in accordance with the American Disability Act. <br />34. All on -site parking spaces will be striped and signed in <br />accordance with the Manual on Uniform Traffic Control <br />Devices Latest Edition. Parking spaces, directional <br />arrows, and stop bars shall be striped in white. It shall <br />be the Owner/Developers responsibility to properly sign <br />and stripe the site in accordance with applicable stds. <br />35. The Owner/Developer acknowledges that this approval <br />does not include any work in the R.O.W. All R.O.W. <br />work shall be a function of an approved F.D.O.T. <br />R.O.W. use permit. <br />36. All clear -site areas shall be kept free of any signage <br />plantings, trees, etc. In excess of three and one-half <br />feet in height. <br />37. All structures including buffer walls, retaining walls, <br />fencing, signage etc. require separate building permits. <br />38. No irrigation system or landscaping shall be installed in any <br />county or state right of way without the appropriate right <br />of way permit. <br />GARDEN VILLAS <br />FOR <br />GARDEN VILLAS, LLC <br />38070DAUGHTERYROAD <br />ZEPHYRHILLS, FLORIDA 33540 <br />SECTION 2, TOWNSHIP 265, RANGE 21 E <br />UTILITY COMPANIES: <br />TELEPHONE: <br />VERIZON <br />27835 WESLEY CHAPEL BL VD. <br />SUITE 100 <br />WESLEY CHAPEL, FLORIDA <br />813-907-8511 <br />CABLE: <br />BRIGHT HOUSE NETWORK <br />CONSTRUCTION DEPARTMENT <br />2728 S. FALKENBURG ROAD <br />ZEPHYRHILLS, FLORIDA 33539 <br />813- 788- 7634 <br />ELECTIRC: <br />DUKE ENERGY <br />36906 EILAND BL VD. <br />ZEPHYRHILLS, FLORIDA 33539 <br />813-782-7237 <br />WA TER: <br />CITY OF ZEPHYRHILLS <br />5335 8th STREET <br />ZEPHYRHILLS, FLORIDA 33542 <br />813-780-0008 <br />ATTN• JOHN BOSTIC <br />WASTE WA TER: <br />CITY OF ZEPHYRHILLS <br />39825 ALSOTN AVENUE <br />ZEPHYRHILLS, FLORIDA 33542 <br />813- 780-0029 <br />ATTN.• JOHN BOSTIC <br />INDEX OF SHEETS <br />LOCATION MAP <br />SHEET <br />NO. SHEET DESCRIPTION <br />NTS <br />1 <br />COVER SHEET AND GENERAL NOTES <br />2 <br />GENERAL NOTES <br />3 <br />SURVEY PLAN <br />4 <br />BORING AND PHRASING PLAN <br />5 <br />BEST MANAGEMENT PRACTICES PLAN <br />6 <br />BEAT MANAGEMENT PRACTICES DETAILS <br />7 <br />SITE PLAN <br />B <br />GRADING AND DRAINAGE PLAN <br />OWNER: VILLAS, LLC <br />9 <br />UTILITY PLAN <br />38070 DA UGHTERY ROAD <br />ZEPHYRHILLS, FLORIDA 33540 <br />10 <br />LIGHTING PLAN <br />11 <br />LANDSCAPE PLAN <br />12 <br />LANDSCAPE NOTES PLAN <br />13 <br />LANDSCAPE BUILDINGS 1-6 PLAN <br />CONTRACTOR: TO BE DETERMINED <br />14 <br />LANDSCAPE BUILDINGS 7-9 PLAN <br />15 <br />PLAN AND PROFILE PLAN <br />16 <br />SANITARY PLAN AND PROFILE PLAN <br />SURVEYOR: TO BE DETERMINED <br />17 <br />UTILITY DETAILS PLAN <br />18 <br />SANITARY DETAILS PLAN <br />19 <br />WATER DETAILS PLAN <br />20 <br />PRE -DEVELOPMENT DRAINAGE AREA <br />21 <br />POST DEVELOPMENT DR4INA6rvZry AREA <br />BEFORE DIGGING CALL <br />SUNSHINE STATE ONE -CALL OF FLA <br />1-800-432-4770 <br />FSS 93,240, SECTI❑NS 556.101-556.111 <br />REQUIRES MIN. OF 2 DAYS AND MAX. OF <br />5 DAYS NOTICE BEFORE YOU EXCAVATE, <br />DO NOT SCALE DRAWINGS <br />The contractor shall verify all plans and existing dimensions <br />and conditions on the job site and shall immediately notify <br />the engineer in writing of any discrepancies before <br />proceeding with the work or be responsible for same. <br />Emails: rroberts.egi®gmail.com troutwein-clem®outlook.com <br />I HEREBY CERTIFY: <br />THAT THE CONSTRUCTION PLANS SHOWN ARE IN COMPLI C <br />WITH CHAPTER 16, SECTION 1609 OF THE 2010 FLORIDA UI IN <br />FOR 150 MPH ULTIMATE DESIGN WIND SPEED (RISK CAT Gql <br />ALONG WITH THE ENTIRE 2010 FLORIDA BUILDING CODE, RESID i <br />EGI-ENGINEERING GREAT IDEAS, LLC <br />William H. Roberts, P.E. <br />1906 W. Thonotosasso Road <br />Suite 2 <br />Plant City, Florida 33563 <br />P.E. #42712 <br />TEL (813) 752-7078 DATE <br />CA #29098 (NOT vino WM W FOR SEAL. OR <br />■■■■■■■■■ <br />■■■■■■■■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />:_: <br />M■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />• <br />• <br />■■ <br />■■ <br />• <br />._ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />_ _ <br />- <br />_ <br />■■ <br />■ <br />ON <br />■ <br />■■ <br />; _ <br />__. <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■ <br />■■■■■■■■■I <br />■■MEMO.■■ <br />■r <br />110 <br />■ ++ <br />1'110 <br />I <br />■i <br />1■ <br />■) <br />'■ <br />■1 <br />1■ <br />■ <br />I■ <br />�-'`'1 <br />�� <br />I� <br />■' <br />'■ <br />■L_----.J■' <br />■■■■■■■■■ <br />I <br />• <br />• <br />J'0 DRAVCN <br />LEM TRAUTWEIN <br />SCALE: <br />NOTED <br />CHEMM & APPROVED <br />CET 6-2-15 <br />C14574 <br />SHEET I OF 21 <br />r <br />N <br />