Laserfiche WebLink
GENERAL PLUMBING TES PLUMBING SYMBOL/LEGEND <br />1. REFERENCE THE SPECIFICATIONS FOR MATERIALS AND EQUIPMENT STANDARDS. - - COLD WATER (CW) <br />2. THE INSTALLATION OF THE PLUMBING SYSTEMS AND EQUIPMENT SHALL COMPLY WITH 2O07 FLORIDA --- -- HOT WATER (HW) <br />BUILDING CODE PLUMBING. <br />- - - - - -- - SANITARY OR WASTE <br />3. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED <br />TO INDICATE EXACT LOCATION OF PIPING AND VALVES. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL SP SAFETY PAN PIPING <br />FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN PROPER CLEARANCES. COORDINATE <br />WITH ALL TRADES AND OTHER POTENTIAL OBSTRUC11ONS AND ROUTE PIPING TO AVOID RV RELIEF VALVE PIPING <br />INTERFERENCES. <br />- - - - - - - - - - - - - VENT <br />4. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL ROOMS OR AS I <br />SPECIFICALLY NOTED. i VTR VENT THRU ROOF (VTR) <br />5. FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND FLOORS WITH LISTED - - - -�'yl WCO WALL CLEANOUT <br />ASSEMBLIES AND SLEEVE WHERE REQUIRED. FIRESTOP ASSEMBLIES SHALL BE EQUAL OR EXCEED <br />THE RATING OF THE WALL OR FLOOR. ALL FIRESTOP ASSEMBLIES SHALL MEET ASTM E-814 <br />REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES AND ADDITIONAL PIPE ®` ` h~� P-TRAP (PLAN VIEW) <br />PENETRATION REQUIREMENTS. <br />EC0 <br />6. PROVIDE ACCESS PANELS TO ALL VALVES LOCATED WITHIN CHASES OR NON -ACCESSIBLE CEILINGS. - - - - GRADE/EXTERIOR CLEANOUT <br />REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. ALL VALVES SHALL BE ACCESSIBLE. <br />-I--e - HOSE BIBB <br />7. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. <br />8. INSTALL CODE REQUIRED FIXED AIR GAPS ON ALL INDIRECT WASTE CONNECTIONS SERVING _ SHUT-OFF VALVE <br />EQUIPMENT, AND APPLIANCES. BALL VALVE <br />9. PROVIDE CLEANOUTS ON ALL SANITARY DRAIN & WASTE, AND CONDENSATE DRAIN PIPING AS -�-- FLOW DIRECTION <br />INDICATED ON THE DRAWINGS, AND AS REQUIRED BY LOCAL AND STATE CODES. INSTALL CLEANOUTS <br />IN ACCESSIBLE LOCATIONS. COORDINATE TOP OF FLOOR/GRADE CLEANOUT ELEVATION WITH TOP OF <br />FINISHED GRADE. <br />10. INSTALL EXTERIOR HOSE BIBBS AT 18" ABOVE FINISHED FLOOR AND FINISHED GRADE. <br />11. UNLESS NOTED OTHERWISE, SLOPE ALL SANITARY DWV, AND CONDENSATE DRAIN PIPING 3" PIPE <br />SIZE & LARGER A MINIMUM OF 1/8" PER FT. OF RUN, AND 2' PIPE SIZE AND SMALLER A MINIMUM <br />1/4" PER FT. OF RUN. SLOPE VENT PIPING DOWN & BACK TO FIXTURES. <br />12. EACH PLUMBING VENT SHALL TERMINATE NOT LESS THAN 10 FT. FROM, OR AT LEAST 3 FT. ABOVE <br />ANY WINDOW, DOOR, OPENING, AIR INTAKE, OR VENT SHAFT. ABBREVIATIONS <br />13. PROVIDE WATER HAMMER ARRESTORS AT ALL PLUMBING FIXTURES OR BATTERY OF FIXTURES WITH AB. ABOVE <br />QUICK -CLOSING VALVES. WATER HAMMER ARRESTORS SHALL BE SIZED PER PDI STANDARDS (PLUMBING & A.F.F. ABOVE FINISHED FLOOR <br />DRAINAGE INSTITUTE). AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER HAMMER ARRESTORS AAV AIR ADMITTANCE VALVE <br />AND SHALL NOT BLDG. BUILDING <br />BE INSTALLED. CW COLD WATER <br />CO CLEANOUT <br />14. WATER SERVICE PIPE (UNDERGROUND) AND THE BUILDING SEWER SHALL BE SEPARATED BY 5 FEET CONN. CONNECTION <br />OF UNDISTURBED OR COMPACTED EARTH. DN. DOWN <br />DFU DRAINAGE FIXTURE UNITS <br />15. PROVIDE ALL NECESSARY VALVES, TRAPS, FLOW CONTROLS, FILTERS, BACKFLOW ASSEMBLIES, ECO EXTERIOR CLEANOUT (GRADE) <br />FAUCETS, STOPS, TAILPIECES, VACUUM BREAKERS, IF NOT FURNISHED WITH EQUIPMENT. F.F.E. FINISHED FLOOR ELEVATION <br />FCO FLOOR CLEANOUT <br />16. CONTRACTOR SHALL ROUGH -IN ALL WASTES AND SUPPLIES TO ALL EQUIPMENT ACCORDING TO FD FLOOR DRAIN <br />MANUFACTURER'S SPECIFICATIONS AND MAKE FINAL CONNECTIONS. HW HOT WATER <br />H.B. HOSE BIBB <br />17. PROVIDE SUPPLY STOPS ON HOT AND COLD WATER PIPE SUPPLYING ALL FIXTURES AND EQUIPMENT. I.E. INVERT ELEVATION <br />MIN. MINIMUM <br />18. PROVIDE APPROVED CHROME PLATED TYPE VACUUM BREAKERS WHERE REQUIRED BY LOCAL CODES, SAN SANITARY <br />AND AS INDICATED ON PLANS FOR NEW WORK. V VENT <br />VTR VENT THRU ROOF <br />19. PROVIDE DIELECTRIC UNIONS WHERE CONNECTIONS ARE MADE BETWEEN DISSIMILAR PIPE MATERIALS. WCO WALL CLEANOUT <br />20. SEE RISER DIAGRAMS FOR PIPE SIZES AND ROUTING NOT SHOWN ON PLANS. <br />21. METER AND SITE UTILITY CONNECTIONS SHALL BE PROVIDED ON SITE UTILITY DRAWINGS. PLUMBING <br />CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO SITE ULIITES. (INC. CLEANOUTS, INCREASES, BACKWATER <br />VALVES, ETC.) <br />22. PRESSURE REDUCING VALVES SHALL BE PROVIDED WHERE THE WATER PRESSURE EXCEEDS 75 PSI FINISH GRADE CLEANOUT <br />AT ANY PLUMBING FIXTURE AND SET PRESSURE TO 40 PSI. WATER VELOCITY SHALL NOT EXCEED 8 , ; Lr . <br />FEET PER SECOND. f�� 3 ,f <br />23. DO NOT PENETRATE WALL FOOTINGS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR TO DROP <br />FOOTINGS AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING_,031 <br />PENETRATING A BEARING WALL OR FOOTING MUST BE SLEEVED AND LOCATION APPROVED BY <br />STRUCTURAL ENGINEER. EXTENSION SAME 2-WAY CLEANOUT <br />24. IF THE INTENT OF THE INFORMATION SHOWN ON THESE DOCUMENTS IS NOT CLEAR, OR IS CAPABLE SIZE AS SEWER. <br />OF MORE THAN ONE INTERPRETATION, SUCH MATTERS WILL BE BROUGHT TO THE ATTENTION OF THE <br />ARCHITECT/ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS, AND THE ARCHITECT/ENGINEER <br />SHALL MAKE CORRECTION OR EXPLANATION IN WRITING. <br />25. WHERE THE CONTRACTOR PROPOSES ALTERNATE SOLUTIONS, DIFFERENT ROUTINGS OF PIPING, <br />DIFFERENT LOCATIONS OF EQUIPMENT, FIXTURES, ETC., THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR ALL OF THE RAMIFICATIONS OF THE PROPOSED CHANGE THAT ARE NOT INCLUDED IN HIS <br />PROPOSAL, BUT BECOME APPARENT AT A LATER DATE, AND SHALL BEAR THE CONSEQUENCES OF PIPE AND FITTING SHALL BE OF THE SAME <br />CORRECTING ANY AND ALL CONFLICTS, DEFICIENCIES OR OTHER PROBLEMS AT NO INCREASE IN MATERIAL AS SEWER IT SERVES. <br />COST OR INCREASE IN CONSTRUCTION TIME ALLOTTED. <br />26. WASHER BOX AND WASHER SUPPLY STOPS TO BE LOCATED WITHIN REACH ABOVE TOP BACK OF WASHING EXTERIOR 2-WAY CLEANOUT <br />MACHINE. NOT TO SCALE <br />27. ALL EQUIPMENT SHALL BE PROVIDED AS SPECIFIED IN THE PLANS. NO SUBSTITUTIONS ARE PERMITTED. IF <br />EQUIPMENT IS NO LONGER AVAILABLE DUE TO DISCONTINUATIONS OR BACK ORDERS, THE CONTRACTOR <br />SHALL SUBMIT FOR EQUIPMENT APPROVAL BY THE ARCHITECT, OWNER, AND ENGINEER. <br />33"X33"X28" DEEP INSIDE CLEAR <br />LINT TRAP W/FRAME & COVER <br />FINISH GRADE <br />WATER HAMMER ARRESTOR SCHEDULE <br />Eff <br />M <br />I FIXTURE UN 6 <br />MANUFACTURER AND PART NUMBER <br />5a <br />la <br />RANGE <br />SIOUX CHIEF 1660-V2B <br />Xz" <br />A <br />1-11 <br />WILKINS #1250-A <br />WATTS #SG-050 <br />-y4" <br />PPP #SC-750B <br />B <br />12-32 <br />WILKINS #1250-B <br />WATTS #SG-075 <br />PPP #SC-1000C <br />1" <br />C <br />33-60 <br />WILKINS #1250-C <br />WATTS #SG-100 <br />PPP #SC-1250D <br />1 7°4" <br />D <br />61-113 <br />WILKINS #1250-D <br />WATTS #SG-125 <br />PPP #SC-1500E <br />1 )g' <br />E <br />114-154 <br />WILKINS #1250-E <br />WATTS #SG-150 <br />PPP #SC-2000F <br />2- <br />F <br />155-330 <br />WILKINS #1250-F <br />WATTS #SG-200 <br />WATER HAMMER ARRESTOR NOTES: <br />1. AIR CHAMBERS ARE NOT AN ACCEPTABLE EQUAL TO WATER HAMMER ARRESTORS AND <br />SHALL NOT BE INSTALLED <br />2. SIZE PER MANUFACTURER'S RECOMMENDATIONS <br />ELECTRIC HEATER SCHEDULE <br />MARK/UNIT <br />EWH-1 <br />MANUFACTURER <br />BRADFORD WHITE <br />MODEL NO. <br />ECT52D <br />TYPE <br />TALL MODEL <br />GALLONS <br />50 <br />VOLT/PHASE/Hz <br />240/1/60 <br />KW <br />6 <br />NO. OF ELEMENTS <br />2 NON-SILMULTANEOUS <br />GPH RECOVERY @ 70' AT <br />35.4 <br />DIMENSIONS <br />57-1/2" X 20- DIA. <br />WEIGHT (EMPTY) <br />123 <br />NOTES: <br />1. PROVIDE ALL GAGES, THERMOSTATS, TEMPERATURE AND PRESSURE RELIEF VALVE, EXPANTION TANK <br />AND SHUT-OFF VALVES AS REQUIRED BY LOCAL CODES AND MANUFACTURERS RECOMMENDATIONS. <br />2. PROVIDE 2' MIN. DEEP 24 GAUGE GALVANIZED STEEL SAFETY PAN. <br />3. PROVIDE INVERTED HEAT TRAPS ON COLD & HOT WATER CONNECTIONS. <br />WATERPROOFING <br />MEMBRANE <br />CAULKING REQ'D. TO <br />PRODUCE A WATERTIGHT SEAL <br />(PROVIDED E'Y OTHERS) <br />41 1:- <br />i <br />-GROUT TO FULLY SEAL (TYP.) <br />4" SANITARY T 23- SQ. <br />BRANCH W/C.O. <br />4' INLET FROM WASHERS <br />4- DISCHARGE TO 11' <br />BLDG. SEWER 1/4" MESH SCREEN LINT BASKET <br />3" FABRICATED FROM 9 GAUGE GALV. <br />END OF LINT BASKET TO HARDWARE CLOTH SOLDERED TO <br />BE LEFT OPEN (NO MESH 5/16- BRASS ROD FRAME. PROVIDE <br />SCREEN) TO FIT OVER BAIL HANDLES & PLACE IN SUMP IN <br />DISCHARGE LINE. INVERTED POSITION. <br />NOTE: <br />LINT TRAP SHALL BE OF PRE -MANUFACTURED TYPE OR 4" <br />THICK CONCRETE TYPE (LT3636) AS MANUFACTURED BY <br />BROOKS PRODUCTS, INC. OR APPROVED EQUAL. FRAME AND <br />COVER SHALL BE AS REQUIRED TO WITHSTAND THE <br />ANTICIPATED TRAFFIC LOADS. <br />LAUNDRY LINT TRAP DETAIL <br />NOT TO SCALE <br />IrPAN <br />WITH CLAMPING COLLAR <br />(WHEN SPECIFIED) <br />REFER TO FLOOR PLANS <br />FOR TYPE OF FIXTURE <br />CONNECTED TO P-TRAP <br />JAY R. SMI H(FlG. NO. 2698) <br />WATER SAVER P-TRAP WITH <br />PRIMER TUBE(CHROME PLATED) <br />PRIMER TUBE(CHROME PLATED) <br />FLOOR DRAIN <br />ESCUTCHEON <br />PLUMBING FIXTURE SCHEDULE <br />MARK <br />FIXTURE <br />SOIL/ <br />E <br />VENT <br />HOTCOLD <br />DESCRIPTION <br />WATER <br />W TER <br />WC-1 <br />WATER CLOSET <br />3" <br />2" <br />1/2" <br />- <br />- PROFLOPF1201/PF3112 ELONGATED WATER CLOSET, 1.6 GPF. <br />- SEAT. CHURCH #295C, ELONGATED, OPEN FRONT COMMERCIAL SEAT. <br />- SUPPLIES: BRASS CRAFT #CR1912DL, CHROME, FLEXIBLE, BRAIDED SUPPLY WITH A BRASS <br />NUT, STOPS ESCUTCHEONS, AND SUPPLIES. <br />WC-2 <br />WATER CLOSET-ADA <br />3" <br />2" <br />1/2" <br />- <br />- PROFLOPF1203 FRONT WATER CLOSET, 1.6 GPF, RIM ® 16-1/2" ADA COMPLIANT. <br />- SEAT. CHURCH #295C, ELONGATED, OPEN FRONT COMMERCIAL SEAT. <br />- SUPPLIES: BRASS CRAFT #CR1912DL, CHROME, FLEXIBLE, BRAIDED SUPPLY WITH A BRASS <br />NUT, STOPS ESCUTCHEONS, AND SUPPLIES. <br />L-1 <br />LAVATORY-ADA <br />1-1/2" <br />1-1/2" <br />1/2" <br />1/2- <br />- PROFLO #PF20174 OVAL VITREOUS CHINA LAVATORY, 20-X17-. <br />- FAUCET: PROFLO JPFLL1011 M SINGLE LEVER LAVATORY FAUCET WITH 2.0 GPM AERATOR. <br />- SUPPLIES: BRASS CRAFT ROUGH BRASS STOPS, PLASTIC ESCUTCHEONS SUPPLIES AND TRAPS. <br />- UNDERSINK PIPING COVER: HANDY -SHIELD #2003, ONE P-TRAP COVER, TWO ANGLE VALVES <br />AND COVERS. <br />L-2 <br />LAVATORY-ADA <br />1-1/2" <br />1-1/2- <br />1/2" <br />1/2" <br />- PROFLO #PF5504, MILTON CHINA, WALL HUNG, 20"X18", ADA. <br />- FAUCET. PROFLO #PFLL1011 M SINGLE LEVER LAVATORY FAUCET WITH 2.0 GPM AERATOR, ADA. <br />- BRASS CRAFT #CR1912DL, ROUGH BRASS STOPS, PLASTIC ESCUTCHEONS SUPPLIES AND TRAPS. <br />- UNDERSINK PIPING COVER: HANDY -SHIELD #2003, ONE P-TRAP COVER, TWO ANGLE VALVES <br />AND COVERS. <br />UR-1 <br />URINAL <br />2" <br />1-1/2" <br />3/4" <br />- <br />- PROFLO #PF1807, WALL HUNG URINAL WITH 3/4- TOP SPUD CONN, WALL HANGER INCLUDED. <br />VALVE: SLOAN #186-1 FLUSH VALVE, 1.0 GPF. <br />UR-2 <br />URINAL-ADA <br />2" <br />1-1/2" <br />3/4" <br />- <br />- PROFLO #PF1807, WALL HUNG URINAL WITH 3/4" TOP SPUD CONN, WALL HANGER INCLUDED. <br />MOUNT AT HANDICAPPED HEIGHT. <br />VALVE: SLOAN #186-1 FLUSH VALVE, 1.0 GPF. <br />S-1 <br />KITCHEN SINK <br />1-1/2- <br />1-1/2" <br />1/2" <br />1/2" <br />- ELKAY #LRAD3321 33- X 21-1/4" X 6 DEEP, REAR DRAIN, 20 GAUGE, 2-COMPT STAINLESS <br />STEEL KIT SINK. <br />- FAUCET, PROFLO #PFLL2001 M SINGLE LEVER, NO SPRAY KITCHEN FAUCET, 2.0 GPM <br />- BRASS CRAFT #CR1912DL, ROUGH BRASS STOPS, PLASTIC ESCUTCHEONS, SUPPLIES, TRAPS, <br />& DISPOSAL WASTE, <br />S-2 <br />KITCHEN SINK - ADA <br />1-1/2- <br />1-1/2- <br />1/2- <br />1/2' <br />- PROFLO #PFT252273 25" X 220 X 6 DEEP, 20 GAUGE, SINGLE STAINLESS STEEL KIT SINK. <br />- FAUCET, PROFLO JPFLL2001 M SINGLE LEVER, NO SPRAY KITCHEN FAUCET, 2.0 GPM <br />- BRASS CRAFT #CR1912DL, ROUGH BRASS STOPS, PLASTIC ESCUTCHEONS, SUPPLIES, TRAPS, <br />& DISPOSAL WASTE, <br />EWC-1 <br />WATER COOLER <br />2" <br />1 1/2" <br />1/2" <br />- <br />- ELKAY EZSTL8C, HANDICAPPED, BI-LEVEL <br />MS-1 <br />MOP SINK <br />3" <br />1 1/2- <br />3/4- <br />3/4" <br />- MUSTEE #63, 10- HIGH WALLS WITH 1- WIDE SHOULDERS. INCLUDES AN INTEGRALLY MOLDED <br />SHELF 10-9/16- WIDE. STAINLESS STEEL FACTORY INSTALLED DRAIN BODY COMPLETE WITH A <br />QDC-3 JOINT CONNECTOR FOR A 3" DRAIN PIPE. A COMBINATION DOME STRAINER AND <br />STAINLESS STEEL LINT BASKKET IS INCLUDED. <br />- FAUCET. PROFLO #PF1180, POLISHED CHROME FINISH, BUILT-IN STOPS, <br />VACUUM BREAKER, LEVER HANDLES, WALL BRACE, AND 3/4" GARDEN HOSE <br />OUTLET. <br />NOTE: <br />ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF THE FLORIDA PLUMBING CODE FOR WATER CONSERVATION. <br />EQUIPMENT SCHEDULE <br />MARK <br />FIXTURE <br />IASLT/E <br />VENT <br />COLD <br />HOT <br />DESCRIPTION <br />WATER <br />WATER <br />WCO-1 <br />WALL CLEAN -OUT <br />SIZE/ <br />- <br />- <br />- <br />-ZURN #Z1469, WALL CLEANOUT WITH TWO-PIECE EXPANDABLE CLEANOUT PLUG, STAINLESS <br />DWG. <br />STEEL ACCESS COVER, AND VANDAL PROOF STAINLESS STEEL SCREW. <br />FCO-1 <br />FLOOR CLEAN -OUT <br />SIZE/ <br />- <br />- <br />- <br />- ZURN #CO-2451, EPDXY COATED CAST IRON FLOOR CLEANOUT WITH 5 IN. (127MM) ROUND <br />DWG. <br />ADJUSTABLE GASKETED HEAVY DUTY NICKEL BRONZE TOP, REMOVABLE GAS TIGHT GASKETED <br />BRASS CLEANOUT PLUG AND NO HUB (STANDARD) OUTLET. <br />IMB-1 <br />ICE MAKER BOX <br />- <br />- <br />1/2- <br />- <br />- OATEY #38685, HIGH IMPACT PLASTIC ICE MAKER BOX, 8 3/4"x7 1/2"0" O.A. CPVC VALVE. <br />HB-1 <br />HOSE BIBB <br />- <br />- <br />3/4" <br />- <br />- ZURN #1341, ANTI -SIPHON, VACUM BREAKER, DESIGNED FOR MILD CLIMATE AREAS. ASSE <br />STANDARD 1011 APPROVED, FURNISHED WITH POLYCARBONATE WHEEL HANDLE AND LOSE TEE <br />KEY. ALUMINUM, BRASS OR CHROME BOX. <br />WB-1 <br />WASHER BOX <br />2" <br />2" <br />1/2- <br />1/2- <br />-OATEY #38937, RECESSED 9"x8"x3" HIGH IMPACT PLASTIC WASHER BOX W/2" OFFSET DRAIN, <br />1/4" TURN VALVES, MOUNTED WATER HAMMER ARRESTORS AND 12"x11- FACE PLATE FRAME. <br />INSTALL PER MANUFACTURER'S RECOMMENDATIONS. <br />FD-1 <br />FLOOR DRAIN <br />3' <br />- <br />- <br />- <br />- OATEY #72000 SERIES, EPDXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, <br />REVERSIBLE CLAMPING COLLAR WITH PRIMARY AND SECONDARY WEEPHOLES, ADJUSTABLE ROUND <br />NICKEL BRONZE STRAINER, AND NO HUB (STANDARD) OUTLET. <br />PROVIDE TRAP PRIMER DEVICE. <br />FD-2 <br />FLOOR DRAIN <br />SIZE/ <br />- <br />- <br />- <br />- ZURN #Z610, HEAVY-DUTY CAST IRON AREA DRAIN WITH ANCHOR FLANGE, WEEPHOLES, <br />DWG. <br />12-1/2" X 12-1/2- SQUARE FIXED TOP WITH DUCTILE IRON GRATE AND NO HUB (STANDARD) <br />OUTLET. <br />CLEANOUT PLUG <br />FINISHED WALL <br />I <br />FINISHED FLOOR <br />I <br />�-- P-TRAP <br />1/2' TYPE "K' SOFT SEAMLESS COPPER <br />WITH NO JOINTS BELOW FLOOR SLAB. <br />SLOPE AT 1/4' PER FOOT MINIMUM TO <br />FLOOR DRAIN CONNECTION. <br />GREY WATER TRAP PRIMER <br />NOT TO SCALE <br />COLD WATER -� <br />p1 Innl V TA ^I I InL1A1 IOC <br />DIELECTRIC UNIION <br />REDUCER (TYP) - <br />HEAT TRAP <br />HOT WATER SUPPLY <br />TET-1 (THERMAL EXPANSION <br />TANK) AMTROL #ST-5 OR APPROVED <br />EQUAL <br />SATE VALVE (TYP) <br />EMPERATURE AND PRESSURE <br />tELIEF VALVE. (ASME) <br />VATER HEATER (SEE WATER <br />iEATER SCHEDULE) <br />END SAFETY PAN DRAIN <br />) RELIEF VALVE DRAIN TO <br />IOR DRAIN <br />1/16" THICK HIGH IMPACT -� <br />PLASTIC OR 24 GA. GALV. <br />STL. 1 1/2- MINIMUM DEEP <br />SALTY PAN. WATER HEATER DETAIL <br />NOT TO SCALE <br />C <br />•�� ENSop <br />�ao� � <br />No. 6078 <br />- TE F CC-o ' STA <br />StFL6C <br />SGM ENGINEERING, INC. <br />F A C I L I T I E S C 0 N S U L T I N G E N G IN E E R S <br />935 Lake Baldwin Lane TEL: (407) 767-5188 <br />Baldwin Park, FAX: (407) 767-5772 <br />Orlando, Florida 32814 CA-00006208 <br />AsProject number. 2010-M <br />www.sgmengineering.com <br />Copyright ©2010 SGM Engineering, Inc. <br />3 <br />W <br />aFORUME <br />0 <br />ARCHITECTURE & <br />INTFRIOR nFSIGN_ INC_ <br />c <br />N PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />0 <br />o 10 onenta avenue, suite 11zi <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Fort King <br />Colony <br />Apartments <br />City of Zephyrhills, FL <br />SET DISTRIBUTIONS: <br />_ 08/08/10 _ u_ Bid &,Permit Set <br />I <br />0 SHEET REVISIONS: <br />EDITED BY: RVA <br />P 18.23 <br />I� cI IT I -T 1� -r r - - <br />