GENERAL PLUMBING TES PLUMBING SYMBOL/LEGEND
<br />1. REFERENCE THE SPECIFICATIONS FOR MATERIALS AND EQUIPMENT STANDARDS. - - COLD WATER (CW)
<br />2. THE INSTALLATION OF THE PLUMBING SYSTEMS AND EQUIPMENT SHALL COMPLY WITH 2O07 FLORIDA --- -- HOT WATER (HW)
<br />BUILDING CODE PLUMBING.
<br />- - - - - -- - SANITARY OR WASTE
<br />3. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED
<br />TO INDICATE EXACT LOCATION OF PIPING AND VALVES. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL SP SAFETY PAN PIPING
<br />FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN PROPER CLEARANCES. COORDINATE
<br />WITH ALL TRADES AND OTHER POTENTIAL OBSTRUC11ONS AND ROUTE PIPING TO AVOID RV RELIEF VALVE PIPING
<br />INTERFERENCES.
<br />- - - - - - - - - - - - - VENT
<br />4. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL ROOMS OR AS I
<br />SPECIFICALLY NOTED. i VTR VENT THRU ROOF (VTR)
<br />5. FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND FLOORS WITH LISTED - - - -�'yl WCO WALL CLEANOUT
<br />ASSEMBLIES AND SLEEVE WHERE REQUIRED. FIRESTOP ASSEMBLIES SHALL BE EQUAL OR EXCEED
<br />THE RATING OF THE WALL OR FLOOR. ALL FIRESTOP ASSEMBLIES SHALL MEET ASTM E-814
<br />REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES AND ADDITIONAL PIPE ®` ` h~� P-TRAP (PLAN VIEW)
<br />PENETRATION REQUIREMENTS.
<br />EC0
<br />6. PROVIDE ACCESS PANELS TO ALL VALVES LOCATED WITHIN CHASES OR NON -ACCESSIBLE CEILINGS. - - - - GRADE/EXTERIOR CLEANOUT
<br />REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. ALL VALVES SHALL BE ACCESSIBLE.
<br />-I--e - HOSE BIBB
<br />7. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS.
<br />8. INSTALL CODE REQUIRED FIXED AIR GAPS ON ALL INDIRECT WASTE CONNECTIONS SERVING _ SHUT-OFF VALVE
<br />EQUIPMENT, AND APPLIANCES. BALL VALVE
<br />9. PROVIDE CLEANOUTS ON ALL SANITARY DRAIN & WASTE, AND CONDENSATE DRAIN PIPING AS -�-- FLOW DIRECTION
<br />INDICATED ON THE DRAWINGS, AND AS REQUIRED BY LOCAL AND STATE CODES. INSTALL CLEANOUTS
<br />IN ACCESSIBLE LOCATIONS. COORDINATE TOP OF FLOOR/GRADE CLEANOUT ELEVATION WITH TOP OF
<br />FINISHED GRADE.
<br />10. INSTALL EXTERIOR HOSE BIBBS AT 18" ABOVE FINISHED FLOOR AND FINISHED GRADE.
<br />11. UNLESS NOTED OTHERWISE, SLOPE ALL SANITARY DWV, AND CONDENSATE DRAIN PIPING 3" PIPE
<br />SIZE & LARGER A MINIMUM OF 1/8" PER FT. OF RUN, AND 2' PIPE SIZE AND SMALLER A MINIMUM
<br />1/4" PER FT. OF RUN. SLOPE VENT PIPING DOWN & BACK TO FIXTURES.
<br />12. EACH PLUMBING VENT SHALL TERMINATE NOT LESS THAN 10 FT. FROM, OR AT LEAST 3 FT. ABOVE
<br />ANY WINDOW, DOOR, OPENING, AIR INTAKE, OR VENT SHAFT. ABBREVIATIONS
<br />13. PROVIDE WATER HAMMER ARRESTORS AT ALL PLUMBING FIXTURES OR BATTERY OF FIXTURES WITH AB. ABOVE
<br />QUICK -CLOSING VALVES. WATER HAMMER ARRESTORS SHALL BE SIZED PER PDI STANDARDS (PLUMBING & A.F.F. ABOVE FINISHED FLOOR
<br />DRAINAGE INSTITUTE). AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER HAMMER ARRESTORS AAV AIR ADMITTANCE VALVE
<br />AND SHALL NOT BLDG. BUILDING
<br />BE INSTALLED. CW COLD WATER
<br />CO CLEANOUT
<br />14. WATER SERVICE PIPE (UNDERGROUND) AND THE BUILDING SEWER SHALL BE SEPARATED BY 5 FEET CONN. CONNECTION
<br />OF UNDISTURBED OR COMPACTED EARTH. DN. DOWN
<br />DFU DRAINAGE FIXTURE UNITS
<br />15. PROVIDE ALL NECESSARY VALVES, TRAPS, FLOW CONTROLS, FILTERS, BACKFLOW ASSEMBLIES, ECO EXTERIOR CLEANOUT (GRADE)
<br />FAUCETS, STOPS, TAILPIECES, VACUUM BREAKERS, IF NOT FURNISHED WITH EQUIPMENT. F.F.E. FINISHED FLOOR ELEVATION
<br />FCO FLOOR CLEANOUT
<br />16. CONTRACTOR SHALL ROUGH -IN ALL WASTES AND SUPPLIES TO ALL EQUIPMENT ACCORDING TO FD FLOOR DRAIN
<br />MANUFACTURER'S SPECIFICATIONS AND MAKE FINAL CONNECTIONS. HW HOT WATER
<br />H.B. HOSE BIBB
<br />17. PROVIDE SUPPLY STOPS ON HOT AND COLD WATER PIPE SUPPLYING ALL FIXTURES AND EQUIPMENT. I.E. INVERT ELEVATION
<br />MIN. MINIMUM
<br />18. PROVIDE APPROVED CHROME PLATED TYPE VACUUM BREAKERS WHERE REQUIRED BY LOCAL CODES, SAN SANITARY
<br />AND AS INDICATED ON PLANS FOR NEW WORK. V VENT
<br />VTR VENT THRU ROOF
<br />19. PROVIDE DIELECTRIC UNIONS WHERE CONNECTIONS ARE MADE BETWEEN DISSIMILAR PIPE MATERIALS. WCO WALL CLEANOUT
<br />20. SEE RISER DIAGRAMS FOR PIPE SIZES AND ROUTING NOT SHOWN ON PLANS.
<br />21. METER AND SITE UTILITY CONNECTIONS SHALL BE PROVIDED ON SITE UTILITY DRAWINGS. PLUMBING
<br />CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO SITE ULIITES. (INC. CLEANOUTS, INCREASES, BACKWATER
<br />VALVES, ETC.)
<br />22. PRESSURE REDUCING VALVES SHALL BE PROVIDED WHERE THE WATER PRESSURE EXCEEDS 75 PSI FINISH GRADE CLEANOUT
<br />AT ANY PLUMBING FIXTURE AND SET PRESSURE TO 40 PSI. WATER VELOCITY SHALL NOT EXCEED 8 , ; Lr .
<br />FEET PER SECOND. f�� 3 ,f
<br />23. DO NOT PENETRATE WALL FOOTINGS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR TO DROP
<br />FOOTINGS AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING_,031
<br />PENETRATING A BEARING WALL OR FOOTING MUST BE SLEEVED AND LOCATION APPROVED BY
<br />STRUCTURAL ENGINEER. EXTENSION SAME 2-WAY CLEANOUT
<br />24. IF THE INTENT OF THE INFORMATION SHOWN ON THESE DOCUMENTS IS NOT CLEAR, OR IS CAPABLE SIZE AS SEWER.
<br />OF MORE THAN ONE INTERPRETATION, SUCH MATTERS WILL BE BROUGHT TO THE ATTENTION OF THE
<br />ARCHITECT/ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS, AND THE ARCHITECT/ENGINEER
<br />SHALL MAKE CORRECTION OR EXPLANATION IN WRITING.
<br />25. WHERE THE CONTRACTOR PROPOSES ALTERNATE SOLUTIONS, DIFFERENT ROUTINGS OF PIPING,
<br />DIFFERENT LOCATIONS OF EQUIPMENT, FIXTURES, ETC., THE CONTRACTOR SHALL BE RESPONSIBLE
<br />FOR ALL OF THE RAMIFICATIONS OF THE PROPOSED CHANGE THAT ARE NOT INCLUDED IN HIS
<br />PROPOSAL, BUT BECOME APPARENT AT A LATER DATE, AND SHALL BEAR THE CONSEQUENCES OF PIPE AND FITTING SHALL BE OF THE SAME
<br />CORRECTING ANY AND ALL CONFLICTS, DEFICIENCIES OR OTHER PROBLEMS AT NO INCREASE IN MATERIAL AS SEWER IT SERVES.
<br />COST OR INCREASE IN CONSTRUCTION TIME ALLOTTED.
<br />26. WASHER BOX AND WASHER SUPPLY STOPS TO BE LOCATED WITHIN REACH ABOVE TOP BACK OF WASHING EXTERIOR 2-WAY CLEANOUT
<br />MACHINE. NOT TO SCALE
<br />27. ALL EQUIPMENT SHALL BE PROVIDED AS SPECIFIED IN THE PLANS. NO SUBSTITUTIONS ARE PERMITTED. IF
<br />EQUIPMENT IS NO LONGER AVAILABLE DUE TO DISCONTINUATIONS OR BACK ORDERS, THE CONTRACTOR
<br />SHALL SUBMIT FOR EQUIPMENT APPROVAL BY THE ARCHITECT, OWNER, AND ENGINEER.
<br />33"X33"X28" DEEP INSIDE CLEAR
<br />LINT TRAP W/FRAME & COVER
<br />FINISH GRADE
<br />WATER HAMMER ARRESTOR SCHEDULE
<br />Eff
<br />M
<br />I FIXTURE UN 6
<br />MANUFACTURER AND PART NUMBER
<br />5a
<br />la
<br />RANGE
<br />SIOUX CHIEF 1660-V2B
<br />Xz"
<br />A
<br />1-11
<br />WILKINS #1250-A
<br />WATTS #SG-050
<br />-y4"
<br />PPP #SC-750B
<br />B
<br />12-32
<br />WILKINS #1250-B
<br />WATTS #SG-075
<br />PPP #SC-1000C
<br />1"
<br />C
<br />33-60
<br />WILKINS #1250-C
<br />WATTS #SG-100
<br />PPP #SC-1250D
<br />1 7°4"
<br />D
<br />61-113
<br />WILKINS #1250-D
<br />WATTS #SG-125
<br />PPP #SC-1500E
<br />1 )g'
<br />E
<br />114-154
<br />WILKINS #1250-E
<br />WATTS #SG-150
<br />PPP #SC-2000F
<br />2-
<br />F
<br />155-330
<br />WILKINS #1250-F
<br />WATTS #SG-200
<br />WATER HAMMER ARRESTOR NOTES:
<br />1. AIR CHAMBERS ARE NOT AN ACCEPTABLE EQUAL TO WATER HAMMER ARRESTORS AND
<br />SHALL NOT BE INSTALLED
<br />2. SIZE PER MANUFACTURER'S RECOMMENDATIONS
<br />ELECTRIC HEATER SCHEDULE
<br />MARK/UNIT
<br />EWH-1
<br />MANUFACTURER
<br />BRADFORD WHITE
<br />MODEL NO.
<br />ECT52D
<br />TYPE
<br />TALL MODEL
<br />GALLONS
<br />50
<br />VOLT/PHASE/Hz
<br />240/1/60
<br />KW
<br />6
<br />NO. OF ELEMENTS
<br />2 NON-SILMULTANEOUS
<br />GPH RECOVERY @ 70' AT
<br />35.4
<br />DIMENSIONS
<br />57-1/2" X 20- DIA.
<br />WEIGHT (EMPTY)
<br />123
<br />NOTES:
<br />1. PROVIDE ALL GAGES, THERMOSTATS, TEMPERATURE AND PRESSURE RELIEF VALVE, EXPANTION TANK
<br />AND SHUT-OFF VALVES AS REQUIRED BY LOCAL CODES AND MANUFACTURERS RECOMMENDATIONS.
<br />2. PROVIDE 2' MIN. DEEP 24 GAUGE GALVANIZED STEEL SAFETY PAN.
<br />3. PROVIDE INVERTED HEAT TRAPS ON COLD & HOT WATER CONNECTIONS.
<br />WATERPROOFING
<br />MEMBRANE
<br />CAULKING REQ'D. TO
<br />PRODUCE A WATERTIGHT SEAL
<br />(PROVIDED E'Y OTHERS)
<br />41 1:-
<br />i
<br />-GROUT TO FULLY SEAL (TYP.)
<br />4" SANITARY T 23- SQ.
<br />BRANCH W/C.O.
<br />4' INLET FROM WASHERS
<br />4- DISCHARGE TO 11'
<br />BLDG. SEWER 1/4" MESH SCREEN LINT BASKET
<br />3" FABRICATED FROM 9 GAUGE GALV.
<br />END OF LINT BASKET TO HARDWARE CLOTH SOLDERED TO
<br />BE LEFT OPEN (NO MESH 5/16- BRASS ROD FRAME. PROVIDE
<br />SCREEN) TO FIT OVER BAIL HANDLES & PLACE IN SUMP IN
<br />DISCHARGE LINE. INVERTED POSITION.
<br />NOTE:
<br />LINT TRAP SHALL BE OF PRE -MANUFACTURED TYPE OR 4"
<br />THICK CONCRETE TYPE (LT3636) AS MANUFACTURED BY
<br />BROOKS PRODUCTS, INC. OR APPROVED EQUAL. FRAME AND
<br />COVER SHALL BE AS REQUIRED TO WITHSTAND THE
<br />ANTICIPATED TRAFFIC LOADS.
<br />LAUNDRY LINT TRAP DETAIL
<br />NOT TO SCALE
<br />IrPAN
<br />WITH CLAMPING COLLAR
<br />(WHEN SPECIFIED)
<br />REFER TO FLOOR PLANS
<br />FOR TYPE OF FIXTURE
<br />CONNECTED TO P-TRAP
<br />JAY R. SMI H(FlG. NO. 2698)
<br />WATER SAVER P-TRAP WITH
<br />PRIMER TUBE(CHROME PLATED)
<br />PRIMER TUBE(CHROME PLATED)
<br />FLOOR DRAIN
<br />ESCUTCHEON
<br />PLUMBING FIXTURE SCHEDULE
<br />MARK
<br />FIXTURE
<br />SOIL/
<br />E
<br />VENT
<br />HOTCOLD
<br />DESCRIPTION
<br />WATER
<br />W TER
<br />WC-1
<br />WATER CLOSET
<br />3"
<br />2"
<br />1/2"
<br />-
<br />- PROFLOPF1201/PF3112 ELONGATED WATER CLOSET, 1.6 GPF.
<br />- SEAT. CHURCH #295C, ELONGATED, OPEN FRONT COMMERCIAL SEAT.
<br />- SUPPLIES: BRASS CRAFT #CR1912DL, CHROME, FLEXIBLE, BRAIDED SUPPLY WITH A BRASS
<br />NUT, STOPS ESCUTCHEONS, AND SUPPLIES.
<br />WC-2
<br />WATER CLOSET-ADA
<br />3"
<br />2"
<br />1/2"
<br />-
<br />- PROFLOPF1203 FRONT WATER CLOSET, 1.6 GPF, RIM ® 16-1/2" ADA COMPLIANT.
<br />- SEAT. CHURCH #295C, ELONGATED, OPEN FRONT COMMERCIAL SEAT.
<br />- SUPPLIES: BRASS CRAFT #CR1912DL, CHROME, FLEXIBLE, BRAIDED SUPPLY WITH A BRASS
<br />NUT, STOPS ESCUTCHEONS, AND SUPPLIES.
<br />L-1
<br />LAVATORY-ADA
<br />1-1/2"
<br />1-1/2"
<br />1/2"
<br />1/2-
<br />- PROFLO #PF20174 OVAL VITREOUS CHINA LAVATORY, 20-X17-.
<br />- FAUCET: PROFLO JPFLL1011 M SINGLE LEVER LAVATORY FAUCET WITH 2.0 GPM AERATOR.
<br />- SUPPLIES: BRASS CRAFT ROUGH BRASS STOPS, PLASTIC ESCUTCHEONS SUPPLIES AND TRAPS.
<br />- UNDERSINK PIPING COVER: HANDY -SHIELD #2003, ONE P-TRAP COVER, TWO ANGLE VALVES
<br />AND COVERS.
<br />L-2
<br />LAVATORY-ADA
<br />1-1/2"
<br />1-1/2-
<br />1/2"
<br />1/2"
<br />- PROFLO #PF5504, MILTON CHINA, WALL HUNG, 20"X18", ADA.
<br />- FAUCET. PROFLO #PFLL1011 M SINGLE LEVER LAVATORY FAUCET WITH 2.0 GPM AERATOR, ADA.
<br />- BRASS CRAFT #CR1912DL, ROUGH BRASS STOPS, PLASTIC ESCUTCHEONS SUPPLIES AND TRAPS.
<br />- UNDERSINK PIPING COVER: HANDY -SHIELD #2003, ONE P-TRAP COVER, TWO ANGLE VALVES
<br />AND COVERS.
<br />UR-1
<br />URINAL
<br />2"
<br />1-1/2"
<br />3/4"
<br />-
<br />- PROFLO #PF1807, WALL HUNG URINAL WITH 3/4- TOP SPUD CONN, WALL HANGER INCLUDED.
<br />VALVE: SLOAN #186-1 FLUSH VALVE, 1.0 GPF.
<br />UR-2
<br />URINAL-ADA
<br />2"
<br />1-1/2"
<br />3/4"
<br />-
<br />- PROFLO #PF1807, WALL HUNG URINAL WITH 3/4" TOP SPUD CONN, WALL HANGER INCLUDED.
<br />MOUNT AT HANDICAPPED HEIGHT.
<br />VALVE: SLOAN #186-1 FLUSH VALVE, 1.0 GPF.
<br />S-1
<br />KITCHEN SINK
<br />1-1/2-
<br />1-1/2"
<br />1/2"
<br />1/2"
<br />- ELKAY #LRAD3321 33- X 21-1/4" X 6 DEEP, REAR DRAIN, 20 GAUGE, 2-COMPT STAINLESS
<br />STEEL KIT SINK.
<br />- FAUCET, PROFLO #PFLL2001 M SINGLE LEVER, NO SPRAY KITCHEN FAUCET, 2.0 GPM
<br />- BRASS CRAFT #CR1912DL, ROUGH BRASS STOPS, PLASTIC ESCUTCHEONS, SUPPLIES, TRAPS,
<br />& DISPOSAL WASTE,
<br />S-2
<br />KITCHEN SINK - ADA
<br />1-1/2-
<br />1-1/2-
<br />1/2-
<br />1/2'
<br />- PROFLO #PFT252273 25" X 220 X 6 DEEP, 20 GAUGE, SINGLE STAINLESS STEEL KIT SINK.
<br />- FAUCET, PROFLO JPFLL2001 M SINGLE LEVER, NO SPRAY KITCHEN FAUCET, 2.0 GPM
<br />- BRASS CRAFT #CR1912DL, ROUGH BRASS STOPS, PLASTIC ESCUTCHEONS, SUPPLIES, TRAPS,
<br />& DISPOSAL WASTE,
<br />EWC-1
<br />WATER COOLER
<br />2"
<br />1 1/2"
<br />1/2"
<br />-
<br />- ELKAY EZSTL8C, HANDICAPPED, BI-LEVEL
<br />MS-1
<br />MOP SINK
<br />3"
<br />1 1/2-
<br />3/4-
<br />3/4"
<br />- MUSTEE #63, 10- HIGH WALLS WITH 1- WIDE SHOULDERS. INCLUDES AN INTEGRALLY MOLDED
<br />SHELF 10-9/16- WIDE. STAINLESS STEEL FACTORY INSTALLED DRAIN BODY COMPLETE WITH A
<br />QDC-3 JOINT CONNECTOR FOR A 3" DRAIN PIPE. A COMBINATION DOME STRAINER AND
<br />STAINLESS STEEL LINT BASKKET IS INCLUDED.
<br />- FAUCET. PROFLO #PF1180, POLISHED CHROME FINISH, BUILT-IN STOPS,
<br />VACUUM BREAKER, LEVER HANDLES, WALL BRACE, AND 3/4" GARDEN HOSE
<br />OUTLET.
<br />NOTE:
<br />ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF THE FLORIDA PLUMBING CODE FOR WATER CONSERVATION.
<br />EQUIPMENT SCHEDULE
<br />MARK
<br />FIXTURE
<br />IASLT/E
<br />VENT
<br />COLD
<br />HOT
<br />DESCRIPTION
<br />WATER
<br />WATER
<br />WCO-1
<br />WALL CLEAN -OUT
<br />SIZE/
<br />-
<br />-
<br />-
<br />-ZURN #Z1469, WALL CLEANOUT WITH TWO-PIECE EXPANDABLE CLEANOUT PLUG, STAINLESS
<br />DWG.
<br />STEEL ACCESS COVER, AND VANDAL PROOF STAINLESS STEEL SCREW.
<br />FCO-1
<br />FLOOR CLEAN -OUT
<br />SIZE/
<br />-
<br />-
<br />-
<br />- ZURN #CO-2451, EPDXY COATED CAST IRON FLOOR CLEANOUT WITH 5 IN. (127MM) ROUND
<br />DWG.
<br />ADJUSTABLE GASKETED HEAVY DUTY NICKEL BRONZE TOP, REMOVABLE GAS TIGHT GASKETED
<br />BRASS CLEANOUT PLUG AND NO HUB (STANDARD) OUTLET.
<br />IMB-1
<br />ICE MAKER BOX
<br />-
<br />-
<br />1/2-
<br />-
<br />- OATEY #38685, HIGH IMPACT PLASTIC ICE MAKER BOX, 8 3/4"x7 1/2"0" O.A. CPVC VALVE.
<br />HB-1
<br />HOSE BIBB
<br />-
<br />-
<br />3/4"
<br />-
<br />- ZURN #1341, ANTI -SIPHON, VACUM BREAKER, DESIGNED FOR MILD CLIMATE AREAS. ASSE
<br />STANDARD 1011 APPROVED, FURNISHED WITH POLYCARBONATE WHEEL HANDLE AND LOSE TEE
<br />KEY. ALUMINUM, BRASS OR CHROME BOX.
<br />WB-1
<br />WASHER BOX
<br />2"
<br />2"
<br />1/2-
<br />1/2-
<br />-OATEY #38937, RECESSED 9"x8"x3" HIGH IMPACT PLASTIC WASHER BOX W/2" OFFSET DRAIN,
<br />1/4" TURN VALVES, MOUNTED WATER HAMMER ARRESTORS AND 12"x11- FACE PLATE FRAME.
<br />INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
<br />FD-1
<br />FLOOR DRAIN
<br />3'
<br />-
<br />-
<br />-
<br />- OATEY #72000 SERIES, EPDXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE,
<br />REVERSIBLE CLAMPING COLLAR WITH PRIMARY AND SECONDARY WEEPHOLES, ADJUSTABLE ROUND
<br />NICKEL BRONZE STRAINER, AND NO HUB (STANDARD) OUTLET.
<br />PROVIDE TRAP PRIMER DEVICE.
<br />FD-2
<br />FLOOR DRAIN
<br />SIZE/
<br />-
<br />-
<br />-
<br />- ZURN #Z610, HEAVY-DUTY CAST IRON AREA DRAIN WITH ANCHOR FLANGE, WEEPHOLES,
<br />DWG.
<br />12-1/2" X 12-1/2- SQUARE FIXED TOP WITH DUCTILE IRON GRATE AND NO HUB (STANDARD)
<br />OUTLET.
<br />CLEANOUT PLUG
<br />FINISHED WALL
<br />I
<br />FINISHED FLOOR
<br />I
<br />�-- P-TRAP
<br />1/2' TYPE "K' SOFT SEAMLESS COPPER
<br />WITH NO JOINTS BELOW FLOOR SLAB.
<br />SLOPE AT 1/4' PER FOOT MINIMUM TO
<br />FLOOR DRAIN CONNECTION.
<br />GREY WATER TRAP PRIMER
<br />NOT TO SCALE
<br />COLD WATER -�
<br />p1 Innl V TA ^I I InL1A1 IOC
<br />DIELECTRIC UNIION
<br />REDUCER (TYP) -
<br />HEAT TRAP
<br />HOT WATER SUPPLY
<br />TET-1 (THERMAL EXPANSION
<br />TANK) AMTROL #ST-5 OR APPROVED
<br />EQUAL
<br />SATE VALVE (TYP)
<br />EMPERATURE AND PRESSURE
<br />tELIEF VALVE. (ASME)
<br />VATER HEATER (SEE WATER
<br />iEATER SCHEDULE)
<br />END SAFETY PAN DRAIN
<br />) RELIEF VALVE DRAIN TO
<br />IOR DRAIN
<br />1/16" THICK HIGH IMPACT -�
<br />PLASTIC OR 24 GA. GALV.
<br />STL. 1 1/2- MINIMUM DEEP
<br />SALTY PAN. WATER HEATER DETAIL
<br />NOT TO SCALE
<br />C
<br />•�� ENSop
<br />�ao� �
<br />No. 6078
<br />- TE F CC-o ' STA
<br />StFL6C
<br />SGM ENGINEERING, INC.
<br />F A C I L I T I E S C 0 N S U L T I N G E N G IN E E R S
<br />935 Lake Baldwin Lane TEL: (407) 767-5188
<br />Baldwin Park, FAX: (407) 767-5772
<br />Orlando, Florida 32814 CA-00006208
<br />AsProject number. 2010-M
<br />www.sgmengineering.com
<br />Copyright ©2010 SGM Engineering, Inc.
<br />3
<br />W
<br />aFORUME
<br />0
<br />ARCHITECTURE &
<br />INTFRIOR nFSIGN_ INC_
<br />c
<br />N PLANNING I ARCHITECTURE I INTERIOR DESIGN
<br />0
<br />o 10 onenta avenue, suite 11zi
<br />altamonte springs, fl 32701
<br />phone: 407.830.1400
<br />fax: 407.830.4143
<br />AA0002731
<br />www.forumarchitecture.com
<br />Fort King
<br />Colony
<br />Apartments
<br />City of Zephyrhills, FL
<br />SET DISTRIBUTIONS:
<br />_ 08/08/10 _ u_ Bid &,Permit Set
<br />I
<br />0 SHEET REVISIONS:
<br />EDITED BY: RVA
<br />P 18.23
<br />I� cI IT I -T 1� -r r - -
<br />
|