9 <br />00 <br />0 <br />0 <br />0 <br />N <br />00 <br />co <br />0 <br />0 <br />Wl <br />CONCRETE MASONRY UNITS FOUNDATION <br />01 ALL CONCRETE MASONRY UNITS SHALL BE HOLLOW LOAD BEARING UNITS CONFORMING TO ASTM C90, GRADE 01 FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF BASED ON A <br />N, TYPE 1, WITH MINIMUM COMPRESSIVE STRENGTH OF UNITS =1,900 PSI ON NET AREA, WITH ASSUMED GEOTECHNICAL REPORT BY FAULKNER ENGINEERING SERVICES INC DATED SEPTEMBER 24, 2007. SHOULD <br />DESIGN COMPRESSIVE STRENGTH, F'M =1,500 PSI. UNITS MAY BE FABRICATED EITHER WITH NORMAL WEIGHT CONDITIONS VARY FROM THE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF <br />AGGREGATE (C33) OR WITH LIGHTWEIGHT AGGREGATE (C331). WORK. <br />02 ALL UNITS SHALL BE PLACED IN RUNNING BOND. 02 ALL FOOTINGS SHALL BE PLACED DIRECTLY ON VIRGIN SOIL, OR CERTIFIED COMPACTED FILL. <br />03 MORTAR SHALL BE TYPE M OR S. MIX 1 PART PORTLAND CEMENT,1/4 TO 1/2 PART HYDRATED LIME AND 2-1/4 <br />TO 3 PARTS SAND, MIXED ON SITE. <br />04 STORE ALL UNITS OFF GROUND TO PREVENT CONTAMINATION. COVER MATERIALS TO PROTECT FROM THE <br />ELEMENTS. <br />05 NO AIR -ENTRAINING ADMIXTURES OR ANTIFREEZE COMPOUNDS, SUCH AS CALCIUM CHLORIDE SHALL BE <br />ADDED TO MORTAR. <br />06 ALL WALLS OR PILASTERS SUPPORTING STEEL AT BEARING PLATES SHALL BE GROUTED SOLID FOR FOUR <br />COURSES IN DEPTH FOR A WIDTH OF 32". <br />07 DO NOT BACKFILL AGAINST FOUNDATION WALLS UNTIL MORTAR HAS ATTAINED MAXIMUM STRENGTH. WHERE <br />BACKFILL IS PLACED AGAINST FOUNDATION WALLS BEFORE FLOOR CONSTRUCTION IS IN PLACE, PROVIDE <br />TEMPORARY BRACING. <br />08 THE FIRST BLOCK COURSE ON FOOTING SHALL BE FILLED SOLID WITH CONCRETE, UNLESS NOTED OTHERWISE <br />IN DRAWINGS. <br />09 VERTICAL CONTROL JOINTS SHALL BE PLACED SUCH THAT THE RATIO OF JOINT SPACING (L) DIVIDED BY WALL <br />HEIGHT (H) DOES NOT EXCEED 3.0. IN NO CASE SHALL SPACING EXCEED 50 FEET. CONTROL JOINTS SHALL BE <br />CONSTRUCTED USING SASH BLOCKS AND DUR-O-WALL PREFORMED REGULAR RAPID CONTROL JOINT (OR <br />EQUAL OF EXTRUDED RUBBER). WALL REINFORCING SHALL BE DISCONTINUOUS AT JOINTS. VERTICAL JOINTS <br />SHALL BE LOCATED AS FOLLOWS: <br />A CHANGES IN WALL HEIGHT. <br />B AT CONSTRUCTION JOINTS IN FOUNDATION, IN ROOF AND IN FLOORS. <br />C AT CHASES AND RECESSES FOR PIPING, COLUMNS, FIXTURES, ETC. <br />D AT ABUTMENT OF WALL AND COLUMNS. <br />E AT RETURN ANGLES IN'L','T' AND'U' SHAPED STRUCTURES. <br />F AT ONE OR BOTH SIDES OF WALL OPENING. <br />10 CMU WALLS SHALL BE REINFORCED WITH TRUSS TYPE REINFORCING OF 9 GAGE ASTM A82 WIRE, GALVANIZED <br />, AT 16" ON CENTER (VERTICALLY), AND AT THE FIRST AND SECOND BED JOINTS ABOVE AND BELOW WALL <br />OPENINGS. <br />11 ALL MASONRY WALLS SHALL BE ADEQUATELY BRACED DURING CONSTRUCTION TO RESIST WIND LOADS OF 25 <br />PSF. NOTE THAT FLOOR AND ROOF DIAPHRAGMS WILL PROVIDE ULTIMATE STABILITY FOR WALLS. UNTIL <br />THESE ARE IN PLACE, MASONRY WALLS SHALL NOT BE BUILT HIGHER THAN 10 TIMES THEIR THICKNESS <br />WITHOUT BRACING. <br />03 CONCRETE FOR FOUNDATIONS: <br />A 28 DAY COMPRESSIVE STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS: <br />FOOTINGS 3000 PSI <br />SLAB ON GRADE 3000 PSI <br />WALLS 3500 PSI <br />B MAXIMUM CONCRETE SLUMP SHALL BE 4". <br />C SLAB ON GRADE SHALL BE 6" THICK WITH WWF 6 x 6 -W1.4 x W1.4. SLAB SHALL BE FINISHED IN <br />ACCORDANCE WITH ACI STANDARD 302 FOR CLASS 2 FLOORS. IN LIEU OF WWF, SLAB ON GRADE MAY <br />CONSIST OF FIBER REINFORCED CONCRETE ACI 544.2R-89. <br />D ALL CONCRETE SHALL BE MIXED, TRANSPORTED AND PLACED IN ACCORDANCE WITH ACI STANDARDS <br />318, 304 AND 301. <br />E ALL REINFORCING BARS SHALL BE OF BILLET STEEL CONFORMING TO ASTM A615, GRADE 60. <br />F ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185. <br />G ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS AND FOOTINGS. <br />H REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER: <br />SLAB ON GRADE 1-1/2" <br />WALLS 2" <br />FOOTINGS 3" <br />1 GRADE BEAMS SHALL BE FORMED ON SIDES. <br />04 ALL FILL SHALL BE PLACED IN 12 INCH LOOSE LIFTS (MAXIMUM) COMPACTED WITH VIBRATORY ROLLERS. FILL <br />MATERIAL SHALL BE TESTED BY MODIFIED PROCTOR DENSITY METHOD (ASTM D1557) AND MUST QUALIFY AS <br />SELECT, WITH LESS THAN 12% PASSING THROUGH THE NO.200 SIEVE. SOIL SHALL BE PLACED WITH MOISTURE <br />CONTENT AND ENERGY TO PROVIDE 98% OF MAXIMUM DRY DENSITY BELOW SLABS ON GRADE. THE UPPER <br />1-FOOT BELOW PAVEMENTS SHOULD BE COMPACTED TO 98% OF MODIFIED MAXIMUM PROCTOR DRY DENSITY. <br />IN PLACE DENSITY TESTS SHALL BE TAKEN FOR EACH 10,000 S.F. IN EACH LIFT. FOR ACCEPTANCE OF SOIL, <br />AVERAGE OF DENSITY TESTS MUST EXCEED THE SPECIFIED COMPACTION. NO TESTS SHALL BE PERMITTED <br />TO FALL BELOW 90% COMPACTION. <br />05 ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 1'-6" BELOW FINAL GRADE WHEN BEARING ON SOIL, <br />UNLESS NOTED OTHERWISE ON THE FOUNDATION DRAWINGS. <br />06 WHERE NECESSARY, FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 VERTICAL TO 2 <br />HORIZONTAL. <br />07 WHERE ROCK OUTCROPPINGS ARE ENCOUNTERED IN A BUILDING FOUNDATION BEARING ON SOIL, SUCH <br />OUTCROPPING OR INTERFERENCE SHALL BE REMOVED TO A DEPTH 12 INCHES BELOW BOTTOM OF FOOTING <br />AND REPLACED WITH CLEAN GRANULAR MATERIAL CONTAINING LESS THAN 5% SILT, COMPACTED TO 95% <br />DENSITY PER MODIFIED PROCTOR METHOD. MAINTAIN A MINIMUM COVER OF 1'-6" TO BOTTOM OF CONCRETE. <br />08 WHERE SOLID UNFRACTURED ROCK IS ENCOUNTERED FOR A WALL LENGTH OF AT LEAST 25 FEET, WALLS MAY <br />BE POURED WITHOUT FOOTINGS BY TRENCHING 6 INCHES INTO THE ROCK AND PINNING THE WALL TO ROCK <br />WITH #6 x T-0" LONG DOWELS AT 2'-8" ON CENTER, GROUTED INTO ROCK, EXTENDING V-6 INTO ROCK. NO <br />FROST PROVISIONS ARE REQUIRED FOR THIS DETAIL. PROVIDE CONTROL JOINT IN WALL AT ANY TRANSITION <br />BETWEEN ROCK BEARING AND SOIL BEARING CONDITIONS. <br />09 EXCAVATIONS SHALL BE DEWATERED TO A DEPTH OF AT LEAST 2 TO 3 FEET BELOW THE BOTTOM OF THE <br />EXCAVATIONS TO ALLOW INSTALLATION OF FOOTINGS IN DRY ATMOSPHERE. <br />10 DIFFERENTIAL BACKFILL AGAINST FOUNDATION WALLS SHALL NOT EXCEED FOUR FEET UNTIL TOP BRACING <br />OR FRAMEWORK HAS BEEN IN PLACE FOR A MINIMUM OF THREE DAYS. CANTILEVERED RETAINING WALLS MAY <br />BE BACK -FILLED WITHIN 14 DAYS OF CONCRETE PLACEMENT, BUT IN NO CASE SHALL DIFFERENTIAL OF <br />BACKFILL, BETWEEN OPPOSITE SIDES OF THE WALL, EXCEED THE FINAL DESIGN DIFFERENTIAL. <br />11 ALL BOTTOM OF FOOTING ELEVATIONS ARE SUBJECT TO CHANGE UPON INSPECTION OF SOIL CONDITION. <br />ELEVATION OF ADJACENT FOOTINGS SHALL VARY ON A SLOPE NOT STEEPER THAN ONE VERTICAL TO TWO <br />HORIZONTAL. <br />12 THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE BOTTOM OF FOOTING ELEVATION IS CHANGED AND <br />OBTAIN REVISED DESIGN OF THE FOUNDATION AND RETAINING WALLS AS REQUIRED. <br />13 A MINIMUM 6-MIL POLYETHYLENE VAPOR BARRIER BETWEEN THE BOTTOM OF THE FLOOR SLAB AND THE TOP <br />OF THE COMPACTED SUBGRADE SHALL BE INSTALLED. <br />GENERAL E CODES <br />01 CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY <br />ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO <br />PROCEEDING WITH THE WORK. <br />02 DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION <br />OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS REGARDING EXACT <br />REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND <br />CLASSIFICATIONS. <br />03 ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK <br />ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A REVIEW <br />OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. <br />04 DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. <br />05 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING <br />TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO <br />PROCEEDING WITH THE PROJECT. <br />06 THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS AND <br />PROGRAMS, AND FOR COORDINATING ALL PORTIONS OF THE WORK. <br />FLORIDA BUILDING CODE - BUILDING 2007 W/APPLICABLE SUPPLEMENTS <br />FLORIDA FIRE PREVENTION CODE 2007 EDITION <br />NATIONAL ELECTRIC CODE 2008 EDITION <br />ACCESSIBILITY <br />IN ADDITION TO CODES LISTED ABOVE, ACCESS TO AND THROUGH THIS AMENITY IS <br />DESIGNED TO CONFORM TO THE FAIR HOUSING ACT OF 1988 AND AMENDMENTS AND <br />FLORIDA ACCESSIBILITY CODE. <br />SUMMARY <br />BUILDING TYPE NO. OF BLDGS. <br />A/C AREA NON A/C AREA TOTAL AREA <br />TRASH COMPACTOR ENCLOSURE 1 <br />908 SF 908 SF <br />® CODE COMPLIANCE <br />OCCUPANCY TYPE <br />U UTILITY <br />CONSTRUCTION TYPE <br />V-B <br />AREA & HEIGHT LIMITATION (FBC-B TABLE 503): <br />REQUIRED/ALLOWED PROPOSED <br />MEAN HEIGHT <br />40' 9'-4" <br />MAXIMUM NUMBER OF FLOORS <br />1 STORY 1 STORY <br />MAXIMUM AREA <br />5,500 SF 908 SF <br />07 ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT THE FIRE PROTECTION (FBC-B TABLES 601 & 602): <br />NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE NUMBERS <br />SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY THE OWNER. INTERIOR BEARING WALLS <br />08 DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, OR INTERIOR NON -BEARING WALLS <br />ROUGH OPENING AT STUD WALLS. COLUMNS <br />BEAMS, GIRDERS & TRUSSES <br />09 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND DATA FLOOR/CEILING ASSEMBLY <br />TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY PRODUCT ROORCEILING ASSEMBLY <br />SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT ORIGINALLY EXTERIOR BEARING WALLS <br />SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE NEW PRODUCT EXTERIOR NON -BEARING WALLS <br />DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED PRODUCT <br />APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT. <br />SITE WORK <br />01 SOIL BEARING VALUES. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR <br />ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS <br />AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE <br />SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE <br />WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT <br />FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR <br />REVISED DESIGNS. <br />02 THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE <br />UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED <br />AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE; SWIMMING POOL, ARCHITECTURAL, <br />STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY <br />COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL <br />CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY. <br />03 REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES, <br />FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC. <br />04 REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL <br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES, <br />ETC. <br />05 CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL <br />NOT BE LESS THAN 6 INCHES, (U.N.O.) <br />06 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT <br />PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE <br />SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. <br />GENERAL - STRUCTURAL <br />01 THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL <br />CHAPTERS OF THE 2007 FLORIDA BUILDING CODE. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH <br />THIS CODE AND ALL LOCAL REQUIREMENTS. <br />02 DESIGN LOADS: <br />A SEE DESIGN CRITERIA ON STRUCTURAL DRAWING. <br />B FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS. <br />C WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />D COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />03 ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING <br />DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE STRUCTURAL <br />ENGINEER PRIOR TO CONSTRUCTION OF WORK. <br />04 THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND VERIFY <br />ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION. NOTIFY THE <br />ARCHITECT / ENGINEER OF ANY DISCREPANCIES. <br />05 IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY <br />CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE <br />MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT / ENGINEER. <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0HR <br />0 HR <br />0 HR <br />0 HR <br />FORUMN <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Fort King <br />Colony <br />Apartments <br />City of Zephyrhills, FL <br />SET DISTRIBUTIONS: <br />08118110 Bid & Permit S t <br />EDITED BY: JT <br />PROJECT NO. 10-2651 <br />�z <br />0 <br />LU <br />Trash Compactor <br />W Enclosure <br />F <br />General Notes & <br />W Code Compliance <br />U <br />W <br />F <br />I <br />U <br />ry <br />ry <br />A 19.31 <br />LL <br />- - _ - - - - _ <br />