Laserfiche WebLink
SECOND FLOOR FINISH PLAN <br />NOT TO SCALE <br />FIRST FLOOR FINISH PLAN <br />NOT TO SCALE <br />UPDATED <br />BACKGROUND <br />FINISH SCHEDULE <br />F C <br />OFFICE <br />Al00 <br />P-CONC <br />B-1 <br />W-1 <br />W-1 <br />W-1 <br />W-1 <br />C-1 <br />WALK OFF CARPET <br />TOILET <br />A102 <br />P-CONC <br />B-1 <br />W-4 <br />W-4 <br />W-4 <br />W-4 <br />C-1 <br />- <br />B - 0 <br />REFER TO FINISH FLOOR PLAN <br />UTILITY ROOM <br />A105 <br />P-CONC <br />B-0 <br />W-1 <br />I W-1 <br />W-1 <br />I W-1 <br />C-0 <br />DISPLAY AREAS <br />S-CONC <br />B-0 <br />REFER TO FINISH FLOOR PLAN C-1 <br />W-3 AT ALL WALLS AS NOTED <br />W-2 AT ALL WALLS U.N.O. <br />ON FIN. FLR. PLANS. <br />FIRST FLOOR: <br />STORAGE AREA <br />100 <br />STAIRS-1 <br />101 <br />S-CONC <br />B-0 <br />W-7 <br />W-7 <br />W-7 <br />W-7 <br />C-2 <br />ELEVATOR MECH. ROOM <br />102 <br />S-CONC <br />B-0 <br />W-7 <br />W-7 <br />W-7 <br />W-7 <br />C-0 <br />STAIRS-2 <br />103 <br />S-CONC <br />B-0 <br />W-7 <br />W-7 <br />W-7 <br />W-7 <br />C-2 <br />ELEVATOR MECH. ROOM <br />104 <br />S-CONC <br />B-0 <br />W-7 <br />W-7 <br />W-7 <br />W-7 <br />C-0 <br />SPRINKLER ROOM <br />105 <br />S-CONC <br />B-0 <br />W-0 <br />W-0 <br />W-0 <br />W-0 <br />C-0 <br />ELECTRICAL ROOM <br />106 <br />S-CONC <br />B-0 <br />W-0 <br />W-0 <br />W-0 <br />W-0 <br />C-0 <br />BDA ROOM <br />107 <br />S-CONC <br />B-0 <br />W-0 <br />W-0 <br />W-0 <br />W-0 <br />C-0 <br />STORAGE UNIT CORRIDOR <br />STORAGE UNITS <br />P-CONC <br />B-0 <br />REFER TO FINISH FLOOR PLAN <br />C-0 <br />S-CONC <br />B-0 <br />REFER TO FINISH FLOOR PLAN <br />C-0 <br />SECOND FLOOR: <br />STORAGE AREA <br />200 <br />STAIRS-1 <br />201 <br />S-CONC <br />B-0 <br />W-7 <br />W-7 <br />W-7 <br />W-7 <br />C-2 <br />STAIRS-2 <br />202 <br />S-CONC <br />B-0 <br />W-7 <br />W-7 <br />W-7 <br />W-7 <br />C-2 <br />TOILET-1 <br />203 <br />CT-1 <br />B-1 <br />W-4 <br />W-4 <br />W-4 <br />W-4 <br />C-1 <br />TOILET-2 <br />j 204 <br />CT-1 <br />B-1 <br />W-4 <br />W-4 <br />W-4 <br />W-4 <br />C-1 <br />STORAGE UNIT CORRIDOR <br />STORAGE UNITS <br />P-CONC <br />B-0 <br />REFER <br />0 FINISH <br />FLOOR RLAN <br />C-0 <br />S-CONC <br />B-0 <br />REFER <br />0 FINISH <br />FLOOR RLAN <br />C-0 <br />THIRD FLOOR: <br />STORAGE AREA 300 <br />STAIRS-1 301 <br />S-CONC <br />B-0 <br />W-7 <br />W-7 <br />W-7 <br />W-7 <br />C-2 <br />STAIRS-2 302 <br />S-CONC <br />B-0 <br />W-7 <br />W-7 <br />W-7 <br />W-7 <br />C-2 <br />STORAGE UNIT CORRIDOR <br />STORAGE UNITS <br />P-CONC <br />B-0 <br />REFER <br />0 FINISH <br />FLOOR RLAN <br />C-0 <br />S-CONC <br />B-0 <br />REFER <br />0 FINISHI <br />FLOOR RLAN <br />j C-0 <br />FINISH LEGEND <br />FLOOR CONDITION <br />S-CONC SEALED CONCRETE <br />2 COATS OF CLEARPROTECT, BY H&C PRODUCT GROUP, (1) AS CURE "N" SEAL AFTER INITIAL <br />CONCRETE POUR, 2) IN STORAGE HALLWAYS, APPLIED THICK WITH NAP ROLLER. <br />P-CONC POLISHED CONCRETE <br />CT-1 12"x12" CERAMIC TILE, TBD <br />PLY-1 <br />3/4" <br />FIRE <br />RATED <br />PLYWOOD <br />MLT <br />MTL <br />STAIR <br />CASE, <br />BY OTHERS <br />BASE CONDITION <br />B-0 NO BASE <br />B-1 6" CERAMIC BASE <br />O 00 <br />� O <br />O <br />r` <br />wl <br />O <br />�t- <br />I 0 <br />0 <br />Z dN- <br />QO <br />w r� <br />W <br />Y <br />Oz <br />�Q <br />WALL CONDITION I— <br />U <br />W-0 WATER/MOLD RESISTANT GYP. BD, W/O PAINT L <br />W-1 PAINTED WATER/MOLD RESISTANT GYP. BD. _ <br />W-2 CORRUGATED METAL LINER PANEL BY M.B.M. FROM F.F. TO 8'-0" A.F.F. U <br />ON ALL INTERIOR FACE OF EXTERIOR WALLS FROM F.F. TO UNDERSIDE OF Q <br />STRUCTURE DECK. <br />W-3 WHITE CORRUGATED LINER PANEL, BY DOOR MANUFACTURER, FROM F.F. TO 9-6" Q <br />ram` A.F.F., GYP. BD. W/O PAINT FROM 9'-6" A.F.F. TO WALL HEIGHT Q <br />W-3.1 DIAMOND PLATED ALUMINUM PANEL FROM F.F. TO 4'-0" HEIGHT OVER WHITE <br />UPDATED CORRUGATED LINER PANEL, BY DOOR MANUFACTURER, FROM F.F. TO TOP OF CORRIDOR <br />BACKGROUND SYSTEM HEIGHT. EXPOSED GYP. BD. OVER CORRIDOR SYSTEM HEIGHT TO BE PAINTED. U) <br />W-4 WATER/MOLD RESISTANT PAINTED GYP. BD. FROM F.F. TO WALL HEIGHT. <br />STORAGE UNIT WALL CONDITION (BY JANUS INTERNATIONAL, OR EQUIVALENT) I I c- <br />W-5 CORRIDOR SIDE AND ENTRY WALL: NON -BEARING MTL PARTITION FROM 0 <br />F.F. TO 8'-0" A.F.F INSTALL PER MANUFACTURER'S RECOMMENDATION • E <br />W-6 INTERIOR PARTITION WALL BETWEEN UNITS: NON -BEARING MTL PARTITION <br />FROM F.F. TO 9'-0" A.F.F. INSTALL PER MANUFACTURER'S RECOMMENDATION <br />W- 7 EXPOSED CMU WALL D <br />W-8 EXPOSED CONCRETE (N/A) I I <br />�7 <br />GENERAL NOTES: . ALL GYPSUM BOARD TO BE WATER/MOLD RESISTANT. OFFICE, BATHROOMS, UTILITY <br />AND MECHANICAL ROOMS. <br />-Q) <br />0 <br />• REFER TO SHEET A-2 FOR 1-HOUR FIRE RATED WALL DETAIL UL No. 456. APPLY <br />• - <br />SPECIFICATIONS WHERE NOTED ON FLOOR PLANS. (N/A) <br />U <br />0 <br />CEILING CONDITION <br />Cn <br />Un <br />C-0 NO CEILING. EXPOSED TO STRUCTURE. <br />C-1 2'x2' ARMSTRONG CEILING TILE <br />C-2 1-HOUR FIRE RATED CEILING UL No. 1506, SYSTEM -A. SEE DETAIL SHEET A-9 <br />C-3 2'x4' ARMSTRONG CEILING TILE (N/A) <br />c- <br />STORAGE UNIT CEILING CONDITION <br />Q) <br />Un <br />C-4 WIRE MESH INSTALLED MIN. 18" BELOW SPRINKLER HEAD <br />c— <br />ELEVATOR FINISHES <br />_+___l <br />c- <br />INTERIOR FINISHES OF THE ELEVATOR CAB WALLS AND FLOOR TO BE DIAMOND PLATE. U <br />DOORS AND FRAME TO BE STAINLESS STEEL. <br />a <br />ER TO EXTRA SPACE STORAGE FOR FINISHES DETAILS AND SPECIFICATIONS. - <br />5 0 <br />RELEASED FOR CONSTRUCTION <br />REVISIONS <br />BY <br />02/04/22 <br />05 10/22 <br />12/22/22 <br />5 <br />PRINTED <br />PERMIT <br />02 04 22 <br />REVISION-1 <br />05/10/22 <br />REVISION-5 <br />12/22/22 <br />AR97003 <br />022.12.26`�� <br />rF�.ED.ARG� <br />Jere ; iah S <br />Russ II <br />Digitall Sig by <br />Jere SS`' <br />Dot 2022.12.26 <br />8:23-06'00' <br />THIS ITEM HAS BEEN DIGITALLY <br />SIGNED AND SEALED BY <br />JEREMIAH RUSSELL ON THE <br />DATE ADJACENT TO THE SEAL. <br />PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND <br />SEALED AND THE SIGNATURE <br />MUST BE VERIFIED ON ANY <br />ELECTRONIC COPIES. <br />W <br />Q <br />0 <br />V) <br />Z <br />L 0 <br />12 LI__� <br />n i <br />0-1 <br />,j 0 <br />LJ cl� N <br />p ul <br />LZ aM <br />M <br />0 0 0 <br />z w <br />o J <br />J <br />m M 0 <br />_3�: ry L M to <br />Lu z J J <br />LLJ <br />V) <br />0 <br />O <br />0 Cr- _J N a- <br />mU N <br />SHEET TITLE <br />FLOOR FINISHES <br />PLAN - FIRST <br />& SECOND <br />FLOORS <br />DRAWN <br />xxxx <br />CHECKED <br />DATE <br />11/2021 <br />SCALE <br />AS NOTED <br />JOB NO. <br />0000 <br />SHEET <br />A <br />13 <br />OF <br />SHEETS <br />