Laserfiche WebLink
REVISIONS I BY <br />Design No. U425 <br />June 10, 2021 <br />Bearing Wall Rating — 3/4 Hr., 1, 1-1/2 or 2 Hr. <br />(See Items 2, 4 and 5) <br />This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress <br />Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor <br />shall be used — See Guide BXUV or BXUV7 <br />* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL <br />Certification (such as Canada), respectively. <br />S <br />INTERIOR OR EXTERIOR WALL (FIRE FROM EITHER SIDE), SEE TABLE I <br />x r. ^k" " . � .'�" ..... `+t. �1c3;e' ....,�,,. r Y a' . .,....�.-..�...-,.—.x .......�..—...,...- ,�` .....,n•�'h'?c' �••�.•.�-_ ..,...,...—....®.a.,.... ...,..-,.M's'-F.'A,T'?f"'.+S] <br />.yt1,K�c'�'d <br />` -- - OPTIONAL: EXTERIOR FACINGS OUTLINED IN ITEM 5 <br />1. Steel Floor and Ceiling Tracks — (Not Shown) — Top and bottom tracks of wall assemblies shall consist of steel members, min <br />No. 20 MSG (0.0329 in., min bare metal thickness) steel or min No. 20 MSG (0.036 in. thick) galv steel or No. 20 MSG (0.033 in. <br />thick) primed steel, that provide a sound structural connection between steel studs, and to adjacent assemblies such as a floor, <br />ceiling, and/or other walls. Attached to floor and ceiling assemblies with steel fasteners spaced not greater than 24 in. O.C. <br />2. Steel Studs — Min 3-1/2 in. wide, No. 20 MSG (0.0329 in., min bare metal thickness) corrosion protected cold formed steel <br />studs designed in accordance with the current edition of the Specification for the Design of Cold -Formed Steel Structural <br />Members by the American Iron and Steel Institute. All design details enhancing the structural integrity of the wall assembly, <br />including the axial design load of the studs, shall be as specified by the steel stud designer and/or producer, and shall meet the <br />requirements of all applicable local code agencies. The max stud spacing of wall assemblies shall not exceed 24 in. OC (or 16 in. <br />OC when Item 5b is used). Studs attached to floor and ceiling tracks with 1/2 in. long Type S-12 steel screws on both sides of studs <br />or by welded or bolted connections designed in accordance with the AISI specifications. <br />2A. Steel Studs — Framing Members* — In lieu of Item 2 — Min 3-1/2 in. wide, No. 20 MSG (0.0329 in., min bare metal <br />thickness) corrosion protected cold formed steel studs designed in accordance with the current edition of the Specification for the <br />Design of Cold -Formed Steel Structural Members by the American Iron and Steel Institute. All design details enhancing the <br />structural integrity of the wall assembly, including the axial design load of the studs, shall be as specified by the steel stud <br />designer and/or producer, and shall meet the requirements of all applicable local code agencies. The max stud spacing of wall <br />assemblies shall not exceed 24 in. OC (or 16 in. OC when Item 5b is used). Studs attached to floor and ceiling tracks with 1/2 in. <br />long Type S-12 steel screws on both sides of studs or by welded or bolted connections designed in accordance with the AISI <br />specifications. <br />EB METAL INC - NITROSTUD <br />2B. Steel Studs — Framing Members* — In lieu of Item 2 — Min 3-5/8 in. wide, No. 20 MSG (0.036 in. min. thickness) corrosion <br />protected cold formed steel studs designed in accordance with the current edition of the Specification for the Design of Cold - <br />Formed Steel Structural Members by the American Iron and Steel Institute. All design details enhancing the structural integrity of <br />the wall assembly, including the axial design load of the studs, shall be as specified by the steel stud designer and/or producer, <br />and shall meet the requirements of all applicable local code agencies. The max stud spacing of wall assemblies shall not exceed 24 <br />in. OC (or 16 in. OC when Item 5b is used). Studs attached to floor and ceiling tracks with 1/2 in. long Type S-12 steel screws on <br />both sides of studs or by welded or bolted connections designed in accordance with the AISI specifications. <br />BAILEY METAL PRODUCTS LTD <br />3. Lateral Support Members — (Not Shown) — Where required for lateral support of studs, support may be provided by means <br />of steel straps, channels or other similar means as specified in the design of a particular steel stud wall system. <br />4. Gypsum Board* — Any 1/2 in. thick UL Classified Gypsum Board that is eligible for use in Design No. X515. Any 5/8 in. <br />thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Gypsum board bearing the UL <br />Classification Marking as to Fire Resistance. Applied vertically with joints between layers staggered. Outer layer of 3 layer <br />construction may be applied horizontally unless specified below. The thickness and number of layers and percent of design load <br />for the 45 min, 1 hr, 1-1/2 hr and 2 hr ratings are as follows: <br />TABLE I <br />Interior or Exterior Walls (Fire From Either Side) <br />Wallboard Protection <br />Both Sides of Wall - <br />No. of Layers & Thkns % of <br />Rating of Board In. Each Layers Design Load <br />45 min <br />1 layer, 1/2 in. thick <br />100 <br />1 hr <br />1 layer, 5/8 in. thick <br />100 <br />1-1/2 hr <br />2 layers, 1/2 in. thick <br />100 <br />2 hr <br />2 layers, 5/8 in. thick or <br />80 <br />2 hr <br />3 layers, 1/2 in. thick <br />100 <br />2 hr <br />2 layers, 3/4 in. thick <br />100 <br />Note: Exterior facings allowed for use with Item 5 are also allowed to be installed on one side of the above walls. <br />WALL TYPE 'S' <br />UL #U425 <br />NOT TO SCALE <br />4B. Gypsum Board* — (As an alternate to Item 4) — Nom. 5/8 in. thick gypsum panels, with square edges, applied horizontally. <br />Gypsum panels fastened to framing with 1 in. long bugle head steel screws spaced a max 8 in. OC, with last 2 screws 3/4 in. and 4 <br />in. from each edge of board. Horizontal joints need not be backed by steel framing. Horizontal edge joints and horizontal butt <br />joints on opposite sides of studs on interior walls need not be staggered. Horizontal edge joints and horizontal butt joints in <br />adjacent layers on interior walls (multilayer systems) staggered a min of 12 in. <br />GEORGIA-PACIFIC GYPSUM L L C — GreenGlass Type X, Type DGG <br />NATIONAL GYPSUM CO — Type FSW-6. <br />CERTAINTEED GYPSUM INC — GlasRoc <br />5. Gypsum Boards — For exterior walls, Rating from Interior Side Only - 1/2 or 5/8 in. thick Classified or unclassified gypsum <br />boards applied vertically and attached to studs and runner tracks with 1 in. long Type S-12 bugle head screws spaced 12 in. OC. <br />along studs and tracks. One of the following exterior facings are to be applied over the gypsum board. <br />a. Siding, Brick, or Stucco — Aluminum siding, steel siding, brick veneer, or stucco attached to studs over gypsum sheathing and <br />meeting the requirements of local code agencies. When a min 3-3/4 in. thick brick veneer facing is used, the Exterior Wall Rating is <br />applicable with exposure on either face. Brick veneer wall attached to studs with corrugated metal wall ties attached to each stud <br />with steel screws, not more than each sixth course of brick. When a min 3-3/4 in. thick brick veneer facing is used, Foamed Plastic <br />(Item 10) may be used. <br />6. Fasteners — (Not Shown) — Screws used to attach wallboard to studs: self -tapping bugle head sheet steel type, spaced 12 in. <br />O.C. First layer Type S-12 by 1 in. long for 1/2 and 5/8 in. thick wallboards and 1-1/4 in. long for 3/4 in. thick wallboard. Second <br />layer Type S-12 by 1-5/8 in. long for 1/2 and 5/8 in. thick wallboards and 2-1/4 in. long for 3/4 in. thick wallboard. Third layer Type <br />S-12 by 1-7/8 in. long. Fasteners when Item 4G is used: First layer #6 x 2 in. long drywall screw spaced 8 in. OC along the perimeter <br />and 12 in. OC in the field. Second layer #6 x 4 in. long drywall screw spaced 8 in. OC along the perimeter and 12 in. OC in the field. <br />Horizontal joints to be staggered 12 in. between layers. <br />7. Batts and Blankets* — Placed in stud cavities of all exterior walls. May or may not be used in interior walls. Any glass fiber or <br />mineral wool batt material bearing the UL Classification Marking as to Fire Resistance, of a thickness to completely fill stud cavity. <br />See Batts and Blankets* (BZJZ) Category for names of Classified companies. <br />8. Joint Tape and Compound — (Not Shown) — Vinyl or casein, dry or premixed joint compound applied in two coats to joints <br />and screw heads of outer layer. Perforated paper tape, 2 in. wide, embedded in first layer of compound over all joints of outer <br />layer. <br />- 2 HR. RATED WALL ASSEMBLY DETAIL <br />Design No. U90S <br />March 02, 2020 <br />Bearing Wall Rating — 2 HR. <br />Nonbearing Wall Rating — 2 HR <br />t011 <br />1 <br />A .., mamr.w.w <br />T <br />ton <br />@ Z <br />1. Concrete Blocks* — Various designs. Classification D-2 (2 hr). <br />See Concrete Blocks category for list of eligible manufacturers. <br />2. Mortar — Blocks laid in full bed of mortar, nom. 3/8 in. thick, of not less than 2-1/4 and not more than 3-1/2 parts of clean <br />sharp sand to 1 part Portland cement (proportioned by volume) and not more than 50 percent hydrated lime (by cement <br />volume). Vertical joints staggered. <br />3. Portland Cement Stucco or Gypsum Plaster — Add 1/2 hr to classification if used. Where combustible members are <br />framed in wall, plaster or stucco must be applied on the face opposite framing to achieve a max. Classification of 1-1/2 hr. <br />Attached to concrete blocks (Item 1). <br />4. Loose Masonry Fill — If all core spaces are filled with loose dry expanded slag, expanded clay or shale (Rotary Kiln Process), <br />water repellant vermiculite masonry fill insulation, or silicone treated perlite loose fill insulation add 2 hr to classification. <br />2 <br />A-14.1 <br />WALL TYPE '2' - UL #UL905 <br />NOT TO SCALE <br />RELEASED FOR CONSTRUCTION <br />N <br />co <br />Cn <br />. E <br />W <br />02/04/22 <br />PRINTED <br />PERMIT <br />02 04 22 <br />.,O <br />AR97003 <br />iQ22.02.0.��� <br />TFAED <br />THIS ITEM HAS BEEN <br />SIGNED AND SEALED <br />DIGITALLY <br />BY <br />JEREMIAH RUSSELL ON THE <br />DATE ADJACENT TO THE SEAL. <br />PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT <br />CONSIDERED SIGNED <br />SEALED AND THE SIGNATURE <br />AND <br />MUST BE VERIFIED ON ANY <br />ELECTRONIC COPIES. <br />LJJ <br />V <br />a <br />O <br />z(A <br />LJJ <br />L LJJ <br />O —� <br />JO <br />LJJ ICY- <br />N <br />Q LO <br />LLJ Z <br />Q In <br />C)O�M <br />z <br />J UJ� <br />0 <br />LL <br />0 <br />m <br />3: 0:� LLi <br />m v <br />Ld <br />o <br />o <br />N a. <br />0o U <br />0) N <br />SHEET TITLE <br />DETAILS <br />— 2 <br />DRAWN <br />XXXX <br />CHECKED <br />DATE <br />11/2021 <br />SCALE <br />AS <br />NOTED <br />JOB NO. <br />0000 <br />SHEET <br />A- <br />14.1 <br />OF <br />SHEETS <br />