Ce3�►Lag7A\�►1911*..1 <br />(THESE SPECIFICATIONS ARE IN ADDITION TO AND DO NOT EXCLUDE <br />ANY FOUND IN THE GENERAL SPECIFICATIONS FOR THE PROJECT) <br />1. CONTRACTOR SHALL BE RESPONSIBLE FOR BRACING AND SHORING OF <br />STRUCTURE DURING CONSTRUCTION. FOUNDATION WALLS WHICH ARE TIED TO SLABS <br />OR FLOOR/ROOF FRAMING SHALL BE BRACED AGAINST BACKFILL MOVEMENT UNTIL <br />SLAB/FRAMING (WTIH DECK ATTACHMENT) IS COMPLETED. CONTRACTOR SHALL <br />PROVIDE ALL TEMPORARY SAFETY ENCLOSURES TO PROTECT ALL PERSONNEL <br />INVOLVED IN PROJECT. <br />2. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INITIATING, MAINTAINING AND <br />SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE <br />WORK. KEYSTONE STRUCTURAL ENGINEERING, P.C., IS NOT RESPONSIBLE FOR THE <br />MEANS AND METHODS OF CONSTRUCTION OR FOR RELATED SAFETY PRECAUTIONS <br />AND PROGRAMS. <br />3. SHOP DRAWINGS AND SUBMITTALS: <br />A. CONTRACTOR SHALL FURNISH COMPLETE AND DETAILED SHOP DRAWINGS. ALL SHOP <br />DRAWINGS SHALL BE PREPARED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL <br />ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. <br />B. CONTRACTOR SHALL REVIEW AND VERIFY ALL DIMENSIONS AND STAMP ALL SHOP <br />DRAWINGS PRIOR TO SUBMITTING DRAWINGS TO ARCH/ENG. FOR REVIEW. <br />CONTRACTOR IS RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE <br />PREPARATION OF SHOP DRAWINGS SUCH AS, MEMBER SIZES, DETAILS AND DIMENSIONS <br />SPECIFIED IN THE CONSTRUCTION DOCUMENTS. <br />C. SHOP DRAWINGS SHALL SHOW MEMBERS SIZES, LOCATION, TYPE AND EXTENT OF <br />ALL MEMBERS, BOLTS AND WELDS. <br />D. CONTRACTOR SHALL HAVE AN APPROVED SHOP DRAWINGS AND PROOF OF WELDER <br />CERTIFICATION AT JOB SITE AT ALL TIMES. <br />E. PROVIDE SETTING DRAWINGS, TEMPLATES AND DIRECTIONS FOR INSTALLATION OF <br />ANCHOR BOLTS AND OTHER ANCHORAGES TO BE INSTALLED BY OTHERS. <br />F. COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. <br />4. DESIGN LOADS: <br />THE BUILDING STRUCTURE DESCRIBED IN THESE PLANS SHALL BE CONSTRUCTED IN <br />COMPLIANCE WITH THE 2017 FLORIDA BUILDING CODE <br />A. GRAVITY LOADS <br />DEAD LOADS: <br />ROOF/ATTIC: 20 PSF <br />FLOOR: 60 PSF <br />LIVE LOADS: <br />ROOF: <br />20 PSF <br />ATTIC: <br />40 PSF <br />FLOOR: <br />125 PSF <br />STAIRS/CORRIDOR: <br />100 PSF <br />B: SNOW LOADS: <br />GROUND SNOW LOAD (Pg): 0.0 PSF <br />FLAT ROOF SNOW LOAD (Pt): 0.0 PSF <br />SNOW EXPOSURE FACTOR (Ce): 1.0 <br />SNOW IMPORTANCE FACTOR (Is): 1.0 <br />THERMAL FACTOR (Ct): 1.0 --� <br />C. WIND LOADS <br />BASIC WIND SPEED (3 SEC. GUST): ult 156 MPH <br />RISK CATEGORY: 11 <br />EXPOSURE CATEGORY: B <br />INTERNAL PRESSURE (GCpi): +-.18 <br />D. SEISMIC DESIGN CRITERIA: <br />SEISMIC IMPORTANCE FACTOR (le): 1.0 <br />RISK CATEGORY: 11 <br />MAPPED SPECTRAL RESPONSE ACCELERATIONS: Ss: 0.0675g S1: 0.0344g <br />SITE CLASS: D <br />S(DS): 0.072 <br />S(D1): 0.055 <br />SEISMIC DESIGN CATEGORY: A <br />BASIC SEISMIC FORCE RESISTING SYSTEM: <br />LIGHT FRAMED WALLS SHEATHED WITH STEEL SHEETS <br />SEISMIC RESPONSE COEFFICIENT (Cs):.0100 <br />RESPONSE MODIFICATION FACTORS (R): 6.5 <br />ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE <br />FOUNDATION NOTES: <br />1. SEE ARCHITECTURAL AND CIVIL DRAWINGS FOR BUILDING LOCATION AND ORIENTATION. <br />COORDINATE ALL DIMENSIONS WITH ARCH. DRAWINGS. DO NOT SCALE DRAWING <br />3. SEE ARCHITECTURAL DRAWINGS FOR SIDE WALK EXTENTS, PLANTER, AND PAVER <br />LOCATIONS AND DETAILS. <br />4. COORDINATE FINISHED FLOOR ELEVATIONS (F.F.E.) WITH ARCH. AND CIVIL DRAWINGS. <br />5. REFERENCE FFE = SEE PLANS <br />6. ALL FOOTINGS HAVE BEEN DESIGNED BASED UPON A SOIL BEARING PRESSURE OF 2500 <br />PSF. FOLLOW ALL RECOMMENDATIONS OUTLINED IN THE GEOTECHNICAL ENGINEERING <br />REPORT BY ECS FLORIDA, LLC., ECS PROJECT NUMBER 41:2804, DATED 07/30/2020. <br />7. ALL FOUNDATION EXCAVATIONS SHALL BE EVALUATED BY THE GEOTECHNICAL <br />ENGINEER OR TESTING AGENCY PRIOR TO POURING ANY FOUNDATION CONCRETE. <br />CONTACT STRUCTURAL ENGINEER IF SOIL BEARING PRESSURE IS LESS THAN 2500 PSF. <br />B. ALL EXTERIOR FOOTINGS SHALL BE A MINIMUM OF 1'- 6" BELOW F.F.E. AND A MINIMUM <br />OF 1'- 6" BELOW ADJACENT EXTERIOR FINISH GRADE (TYP. UNO) <br />9. TOP OF INTERIOR FOOTINGS SHALL BE A MINIMUM OF 1'- 0" BELOW F.F.E. (UNO) <br />10. PRIOR TO COMMENCING ANY FOUNDATION WORK, COORDINATE WORK WITH ANY <br />EXISTING OR NEW UTILITIES. LOWER FOUNDATION AS REQUIRED TO AVOID <br />INTERFERENCE WITH UTILITIES. <br />INDICATES FOOTING STEP. SEE PLANS <br />SPECIALTY ENGINEERED PRODUCTS: <br />1. THE GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE THE PROPER SUBMISSION OF <br />SPECIALTY ENGINEERED SHOP DRAWINGS WHICH SHALL BE SIGNED AND SEALED BY AN <br />ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. IT IS THE GENERAL <br />CONTRACTOR'S RESPONSIBILITY TO ASSURE THAT THE SPECIALTY ENGINEERED SHOP <br />DRAWINGS ARE SUBMITTED IN A TIMELY MANNER SO AS TO ALLOW REVIEWS AND <br />RESUBMISSIONS AS REQUIRED. ALL SPECIALTY ENGINEERED PRODUCTS SHALL BE DESIGNED <br />FOR THE APPROPRIATE GRAVITY LOADS AND WIND LOADS INCLUDING UPLIFT AND LATERAL <br />LOADS. INTERIOR SPECIALTY PRODUCTS SHALL BE DESIGNED FOR LATERAL LOADS TO ASSURE <br />STABILITY. SPECIALTY ENGINEERED PRODUCTS SHALL BE, BUT ARE NOT LIMITED TO, THE <br />FOLLOWING: <br />A. LIGHT GAUGE METAL FRAMING INCLUDING, BUT NOT LIMITED TO, SOFFITS, CLADDING, <br />CEILINGS, ETC. <br />B. MISCELLANEOUS METALS INCLUDING STEEL STAIRS, MECHANICAL EQUIPMENT SUPPORTS, <br />FRAMES THAT SUPPORT MACHINES, PIPES OR OTHER STRUCTURAL METAL USED FOR <br />SUPPORT OF MECHANICAL SYSTEMS. <br />C. MISCELLANEOUS HANGARS, METAL FRAMES, LADDERS, RIGGING, HANGING WALLS, METAL <br />RAILINGS, <br />GLAZING FRAMES, CLADDING SUCH AS STONE, PRECAST, ALUMINUM, METAL PANELS, CABLE <br />BARRIER SYSTEMS, ETC. OR ANY OTHER MISCELLANEOUS PRODUCT REQUIRED BY THE <br />ARCHITECTURAL OR MECHANICAL CONSTRUCTION DOCUMENTS. <br />CONCRETE SLAB ON GRADE NOTES: <br />1. FLOOR SLABS ON GRADE SHALL BE 7" THICK 3000 PSI MINIMUM COMPRESSIVE STRENGTH <br />NORMAL WEIGHT CONCRETE. REINFORCED w/ #4's @ 10" o.c. EACH WAY UNLESS NOTED <br />OTHERWISE, LOCATE 2" FROM BASE OF SLAB -ON -GRADE. SEE CIVIL PLANS FOR FINISHED <br />FLOOR ELEVATIONS. COORDINATE VAPOR BARRIER REQUIREMENTS w/ ARCHITECTURAL AND <br />GEOTECHNICAL ENGINEER REQUIREMENTS, PROVIDE 15 MIL (MIN) POLYETHYLENE VAPOR <br />BARRIER WITH JOINTS LAPPED 6" AND TAPED UNDER ALL INTERIOR SLABS. REFER TO <br />GEOTECHNICAL ENGINEER FOR BELOW SLAB ON GRADE, SUBGRADE PREPARATION <br />REQUIREMENTS.. <br />2. CONTROUCONSTRUCTION JOINTS SHALL BE LOCATED SUCH THAT NO AREA EXCEEDS 150 <br />SQUARE FEET NOR SHALL THE LENGTH EXCEED 1.5 TIMES THE WIDTH. CONSTRUCTION <br />JOINTS MY BE SUBSTITUTED FOR CONTROL JOINTS. METAL " KEYHOLD" JOINTS SHALL BE <br />USED AT ALL CONSTRUCTION JOINTS. LOCATE ALL CONTROL JOINT EQUAL DISTANCE <br />BETWEEN LOAD BEARING WALL AND 5'-0" MIN FROM THE END OF LOAD BEARING WALLS <br />(INCLUDING OPENINGS ETC.) <br />3. CONDUITS AND PIPES EMBEDDED IN SLABS: <br />SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE-THIRD THE OVERALL THICKNESS <br />OF THE SLAB. SHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS OR WIDTHS ON <br />CENTER. A MINIMUM SLAB THICKNESS OF 41/2" MUST BE MAINTAINED OVER THE EMBEDDED <br />CONDUITS OR PIPES. <br />6/S3.1 <br />4. THICKEN SLAB AT LOCATIONS INDICATED ON FOUNDATION PLAN SEE <br />D <br />it <br />0 <br />Z <br />a <br />U� <br />2m <br />n. N <br />o C:; <br />N <br />a <br />C9 J <br />O <br />N <br />O �I <br />STEEL NOTES: <br />1. STRUCTURAL STEEL: <br />A. SHALL CONFORM TO THE LATEST STANDARDS OF ASTM: <br />WIDE FLANGE BEAMS: A992 <br />MISC. STRUCTURAL STEEL SHAPES, PLATES AND BARS: AW <br />HOLLOW STRUCTURAL STEEL SECTIONS (ROUND AND RECTANGULAR): <br />A500 GRADE B <br />STRUCTURAL STEEL PIPE: A53 GRADE B <br />B. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN <br />ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE AMERICAN <br />INSTITUTE OF STEEL CONSTRUCTION (AISC 360-05) USING ALLOWABLE STRESS <br />DESIGN. <br />C. PROVIDE 1" (MINIMUM) NON -SHRINK GROUT UNDER ALL BASE PLATES. <br />D. SHOP OR FIELD SPLICES BETWEEN SUPPORTS THAT ARE NOT REQUIRED BY <br />DESIGN WILL NOT BE ALLOWED. ANY MEMBERS CONTAINING SUCH SPLICES <br />FOUND IN THE FIELD SHALL BE REMOVED AND REPLACED WITH UNSPLICED <br />MEMBERS AT THE FABRICATOR'S EXPENSE. <br />2. STEEL CONNECTIONS: <br />A. WHERE BEAM REACTIONS OR DETAILS ARE NOT SHOWN IN THE CONSTRUCTION <br />DOCUMENTS. CONNECTIONS SHALL BE DESIGNED FOR ONE-HALF THE MAXIMUM <br />(SIMPLE SPAN) UNIFORM LOAD WHICH THE MEMBER WILL SUPPORT FOR THE <br />SPAN SHOWN ON THE DRAWINGS. <br />B. BOLTS SHALL BE HIGH STRENGTH A-325 BOLTS OF SAME SIZE AND NUMBER <br />AS SHOWN ON DRAWINGS. CONNECTIONS SHALL CONFORM TO THE <br />SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A-325 OR A-490 BOLTS. <br />CONNECTIONS ARE BEARING TYPE. <br />C. BOLTS SHALL BE TIGHTENED TO THE SNUG TIGHT CONDITION UNLESS <br />OTHERWISE NOTED ON THE DRAWINGS. <br />3. WELDS: <br />A. MINIMUM SIZE OF WELD IS 3/16" AND (E70XX) UNLESS NOTED OTHERWISE. <br />B. ALL WELDING SHALL CONFORM TO THE LATEST "STRUCTURAL WELDING CODE" <br />BY THE AMERICAN WELDING SOCIETY. ALL WORK SHALL BE PERFORMED BY <br />CERTIFIED WELDERS EXPERIENCED IN THE TYPE OF CONSTRUCTION INVOLVED. <br />PROOF OF WELDER CERTIFICATION SHALL BE AVAILABLE AT THE JOB SITE. <br />4. PROVIDE ALL SUPPORTING STEEL NOT INDICATED ON PLAN AS REQUIRED FOR <br />THE INSTALLATION OF MECHANICAL EQUIPMENT AND MATERIALS, INCLUDING <br />ANGLES, CHANNELS, BEAMS, HANGERS, ETC. DO NOT SUPPORT EQUIPMENT OR <br />PIPING FROM METAL DECKING. <br />5. STEEL STAIRS: <br />ENGINEERED CONCRETE FILLED STEEL STAIR SYSTEM AND ALL CONNECTIONS OF <br />THE SAME TO THIS STRUCTURE SHALL BE DESIGNED BY AN ENGINEER <br />REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. SUBMIT SHOP <br />DRAWINGS BEARING THE SEAL AND THE SIGNATURE OF THE ENGINEER FOR <br />REVIEW PRIOR TO FABRICATION. THE CONFIGURATION OF THE STEEL STAIR <br />SYSTEM SHALL BE SHOWN ON THE ARCHITECTURAL DRAWINGS. STEEL STAIR <br />SYSTEM AND ALL CONNECTIONS SHALL BE DESIGNED FOR ALL APPLICABLE <br />LOADS AS INDICATED ON THE PLANS AND IN ALL APPLICABLE BUILDING CODES. <br />THE LOADS SHALL BE CLEARLY INDICATED ON ALL SHOP DRAWINGS. SHOP <br />DRAWINGS SHALL SHOW AND SPECIFY ALL CONNECTIONS UTILIZED WITHIN THE <br />STEEL STAIR SYSTEM AS WELL AS CONNECTIONS TO AND LOADS IMPOSED UPON <br />THE STRUCTURAL SYSTEM SHOWN OF THESE PLANS. <br />COLD FORMED METAL FRAMING NOTES: <br />1. METAL FRAMING; <br />NON-STANDARD SSMA METAL FRAMING MEMBER (CEE (C), TRACK, ZEE (Z) & HAT <br />CHANNELS) DIMENSIONS, CONFIGURATIONS AND SECTION PROPERTIES SHALL <br />COMPLY WITH THE 2013 AISI, COLD -FORMED STEEL DESIGN SPECIFICATIONS <br />2. USE STEEL TO FORM ZINC COATED (GALVANIZED) NON-STANDARD SSMA METAL <br />FRAMING MEMBERS TO MEET THE PHYSICAL AND CHEMICAL PROPERTIES OF ASTM <br />A653, GRADE 55 (FY=55 KSI), AND G60 COATING DESIGNATION AS DESCRIBED IN ASTM <br />A 924 <br />3. USE STEEL TO FORM PRIMED NON-STANDARD SSMA METAL FRAMING MEMBERS <br />TO MEET THE PHYSICAL AND CHEMICAL PROPERTIES OF ASTM A1011, GRADE 55 (FY= <br />55 KSI). <br />4. SUBMIT SHOP DRAWING INDICATING MEMBER DIMENSIONS, CONFIGURATIONS, <br />SECTION PROPERTIES, COATING, DETAIL OF FABRICATION, DETAILS OF ATTACHMENT <br />TO ADJOINING WORK AND DETAILS OF ALL FASTENERS INCLUDING LOCATION AND <br />SPACING OF ALL FASTENERS ATTACHING FRAMING TO ITSELF. <br />5. SHOP DRAWING SUBMITTAL TO INCLUDE PLANS, ELEVATIONS, SECTIONS AND <br />DETAILS <br />6. SUBMIT SHOP DRAWINGS INCLUDING CALCULATIONS PREPARED, SIGNED AND <br />SEALED BY A ENGINEER LICENSED WITH AND ACTIVE REGISTRATION IN THE STATE <br />WHERE THE PROJECT IS LOCATED. <br />7. SCREWS SHALL BE SELF DRILLING TYPE SCREWS OF THE OF THE MINIMUM <br />DIAMETER INDICATED ON PLANS AND DETAILS WITH A MIN PENETRATION THROUGH <br />JOINED MATERIAL OF NOT LESS THAN (3) EXPOSED THREADS. <br />8. SCREW SPACING AND EDGE DISTANCES SHALL BE (3) SCREW DIAMETERS WITH A <br />MIN 1/2" DIMENSION. <br />9. SCREW SHALL HAVE A PROTECTIVE COATING OF NOT LESS THAN THE JOINED <br />MEMBER PROTECTIVE COATING. <br />10. ALL BOLTS FOR CONNECTIONS SHALL CONFORM TO ASTM A325 <br />11. DO NOT ALTER, CUT OR REMOVE MEMBERS OR CONNECTIONS OF MEMBERS <br />WITH PRIOR WRITTEN APPROVAL OF ENGINEER. <br />12. FIELD TOUCH UP ALL FIELD WELDS AND ABRASIONS OF GALVANIZED MATERIALS <br />WITH ZINC RICH PAINT IN ACCORDANCE WITH ASTM A 780, ANNEX A2. TOUCH UP <br />WORK SHALL BE COMPLETED PRIOR TO ATTACHMENT OF THE WORK OF ANY OTHER <br />SECTIONS TO THE LIGHT GAUGE STEEL FRAMING. <br />13. STANDARD SSMA METAL STUD AND TRACK FRAMING <br />A. METAL STUD STRENGTH CRITERIA: <br />1. 18 MIL TO 43 MIL - 33 KSI MIN. YIELD STRESS <br />2. 54 MIL TO 97 MIL - 50 KSI MIN. YIELD STRESS <br />3. RUNNER TRACK - 33 KSI MIN. YIELD STRESS (UNO) <br />DO NOT USE STUDS LESS THAN 43 MIL FOR ANY EXTERIOR WALL USED TO <br />BACK-UP BRICK VENEER. <br />B. ATTACH METAL FRAMING TO PRIMARY STRUCTURE WITH A DEFLECTION TRACK OR <br />A STEEL NETWORK INC. VERTICAL DEFLECTION CLIPS CAPABLE OF ALLOWING 1" OF <br />VERTICAL DEFLECTION. <br />14. METAL STUD FASTENERS: <br />A. SCREW CONNECTIONS <br />USE #10-16 KWIK-FLEX SELF -DRILLING SCREWS OR APPROVED EQUAL <br />UNLESS OTHERWISE NOTED. 4 SCREWS PER CONNECTION MIN., UNLESS <br />NOTED OTHERWISE OR A PRE-ENGINEERED TRUSS. <br />B. POWER DRIVEN FASTENERS: <br />1. FASTENING TO CONCRETE: <br />USE 0.145" DIA. DOME HEAD NAIL TYPE "X-ZF" BY HILTI OR APPROVED EQUAL <br />UNLESS NOTED OTHERWISE. <br />MIN. EMBEDMENT = 1 1/4" MIN. EDGE DISTANCE = 2" <br />MIN. SPACING = 3" MAX. SPACING =12" <br />2. FASTENING TO STEEL: <br />USE 0.145" DIA. DOME HEAD KNURLED SHANK FASTENER TYPE "X-EDNI" BY <br />HILT[ OR APPROVED EQUAL UNLESS NOTED OTHERWISE. <br />MIN. EMBEDMENT = FULL PENETRATION <br />MIN. EDGE DISTANCE = 1/2/1 <br />MIN. SPACING = 1 1/2" MAX. SPACING 12" <br />15. FASTEN 5/8" PLYWOOD (STRUCTURAL RATED SHEATHING) FOR SIGNAGE <br />ATTACHMENT TO METAL STUD FRAMED WALL AND PARAPETS WITH #12 SCREWS, <br />SPACED AT 6" o.c. FOR THE PANEL EDGES AND FIELD ON STUDS SPACED AT 24" o.c.. <br />SEE ARCHITECTURAL DRAWINGS FOR PLYWOOD LOCATIONS AND EXTENT. <br />ROOF FRAMING NOTES: <br />1. DESIGN ROOFING FOR A NET UPLIFT PER COMPONENT AND CLADDING SCHEDULE ON <br />SO. 1. NO 1/3 STRESS INCREASE ALLOWED. <br />2. STANDING SEAM ROOF (SEE ARCHITECTURAL). COORDINATE FASTENER <br />REQUIREMENTS AND FLASHING DETAILS WITH MANUFACTURER SELECTED. <br />3. COORDINATE THE EXACT LOCATION AND EXTENT OF ROOF HATCH OPENINGS WITH <br />ARCH. DRAWINGS. <br />FLOOR FRAMING NOTES: <br />3. FLOOR SLAB SHALL BE 51/2" (TOTAL THICKNESS) WITH NORMAL WEIGHT <br />CONCRETE (f c=3000 PSI) ON 3" 20 GAUGE COMPOSITE METAL DECK (50 Fy) <br />(NEW MILLENNIUM 3.0 CD OR EQUAL). REINFORCE SLAB WITH WWR: 6X6- <br />W1.4XW1.4 LOCATED AT MID -DEPTH OF SLAB. <br />4. ATTACHMENT OF FLOOR DECK TO SUPPORTS WITH (#12 TEK SCREWS) <br />IN A 36/4 PATTERN WITH 4 SIDE LAPS PER SPAN (#10 SCREWS). <br />ATTACHMENT AT PERIMETER OF DECK SHALL BE EQUAL TO ATTACHMENT <br />AT DECK SIDE LAPS AND DECK SHEET ENDS. ANY PARTIAL OR SKEWED <br />SHEETS SHALL BE ATTACHED AT EVERY FLUTE REGARDLESS OF <br />ATTACHMENT PATTERN. <br />- r 3" TYPE 3.00D 20GA. (.0358") <br />36/4 11 (3 SPAN MIN.) <br />(G60 GALVANIZED.) <br />5. SUSPENDED CEILINGS, LIGHT FIXTURES, DUCTS AND OTHER <br />PERMANENT SUSPENDED LOADS SHALL NOT BE SUPPORTED BY THE <br />METAL DECKING. <br />6. PROVIDE 51/2"x5" LLV 14GA CONT. POURSTOP ANGLE AT ALL DECK <br />EDGES AND AROUND ALL OPENINGS IN FLOOR SLAB. <br />7. PROVIDE 6"x4"x5/16" ANGLE AT ALL DECK EDGES SUPPORTED ON CMU <br />WALLS. <br />SPECIAL INSPECTIONS: <br />A. THE SPECIAL INSPECTOR SHALL BE ENGAGED BY THE OWNER. SPECIAL <br />INSPECTOR SHALL BE FULLY QUALIFIED, APPROVED BY THE BUILDING OFFICIAL, <br />REGISTERED BY APPLICABLE REGISTRATION BOARD IF REQUIRED BY THE <br />LOCAL BUILDING OFFICIAL, AND SHALL BE ACCEPTABLE TO THE ARCHITECT. <br />B. THE SPECIAL INSPECTOR SHALL PROVIDE VERIFICATION OF CONSTRUCTION <br />QUALITY CONTROL INSPECTIONS AND TESTING. THE SPECIAL INSPECTOR SHALL <br />CERTIFY THAT ALL WORK REQUIRING INSPECTION IS PERFORMED IN COMPLIANCE <br />WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS, BUILDING CODE <br />REQUIREMENTS AND LOCAL BUILDING DEPARTMENT REQUIREMENTS. <br />C. SPECIAL INSPECTIONS ARE REQUIRED FOR THE ITEMS NOTED IN THE STATEMENT <br />OF SPECIAL INSPECTIONS AND THE 2012 IBC CHAPTER 17. THE CONTRACTOR <br />SHALL OBTAIN A COPY OF THE STATEMENT OF SPECIAL INSPECTIONS AND <br />NOTIFY THE SPECIAL INSPECTOR WHEN WORK IS READY TO BE INSPECTED. <br />D. FAILURE TO NOTIFY THE SPECIAL INSPECTOR PRIOR TO OBSCURING AN ITEM <br />REQUIRING INSPECTION MAY RESULT IN THE CONTRACTOR REMOVING OTHER <br />WORK TO ALLOW INSPECTION. THIS WORK WILL BE REMOVED AND REPLACED <br />AT THE CONTRACTORS EXPENSE. FAILURE TO HAVE REQUIRED ITEMS INSPECTED <br />IS REASON FOR REJECTION OF THE WORK. <br />E. PREMATURE NOTIFICATION FOR INSPECTIONS WILL RESULT IN ADDITIONAL <br />INSPECTION WITH ALL EXPENSES AND FEES PAID FOR BY THE CONTRACTOR. <br />SHEAR WALL AND WALL PANEL NOTES <br />1. 26 GAUGE PBU WALL PANELS WHERE NOTED, ALL OTHER PANELS SHALL BE 29 <br />GAUGE PBU WALL PANELS. ALL WALL PANELS SHALL BE GRADE 80 <br />2. ATTACH ALL PBU PANEL ENDS TO SUPPORTS WITH #12 TEK SCREWS AT 6" o.c. <br />AND TO INTERMEDIATE SUPPORTS AT 12" o.c. <br />3. SIDELAP ATTACHMENT FOR WALLS DESIGNATED AS SHEAR WALLS ON THE <br />PLANS SHALL BE #12 TEK SCREWS AT 12" o.c. (20" o.c. FOR ALL OTHER WALL). FOR <br />WALLS DESIGNATED AS SHEAR WALLS ON THE PLANS, FASTEN BOTTOM EDGE OF <br />PANEL TO BOTTOM TRACK WITH #12x3/4" TEK SCREW PANEL FASTENERS @ 12" o.c. <br />(20" o.c. FOR ALL OTHER WALL). <br />4. ALL PERIMETER PANELS SHALL BE FULL HEIGHT 29 GAUGE PBU WALL PANELS <br />OVER RATED GYPSUM WALL BOARD (SEE ARCH.). <br />5. ALL INTERIOR PANELS SHALL BE 9'- 0" HIGH. COORDINATE EXACT PANEL HEIGHT <br />WITH ARCHITECTURAL. <br />6. THERE SHALL BE A DOUBLE STUD AT EACH END OF EACH SHEAR WALL AT THE <br />LEVEL OF THE SHEAR WALL AND ALL LEVELS BELOW WITH THE EXCEPTION OF <br />SHEAR WALLLS AT THE ROOF LEVEL. THE DOUBLE STUD SIZE, TYPE AND GAUGE <br />SHALL BE EQUAL TO THE SHEAR WALL FRAMING MEMBERS AT EACH LEVEL. <br />7. SCREWS SHALL BE SELF DRILLING TYPE SCREWS WITH A MIN PENETRATION <br />THROUGH JOINED MATERIAL OF NOT LESS THAN (3) EXPOSED THREADS. <br />8. SHEAR WALLS DESIGNATED ON A LEVEL ARE THE WALLS BELOW THAT LEVEL. <br />SW-1 29 GAUGE PBU PANEL ON ONE SIDE OF WALL TO 9'- 0" MINIMUM WITH <br />STRAP BRACES ABOVE TOP OF PANEL <br />SW-2 26 GAUGE PBU PANEL ON ONE SIDE OF WALL TO 9'- 0" MINIMUM WITH <br />STRAP BRACES ABOVE TOP OF PANEL <br />HEADER CONNECTION <br />SCHEDULE <br />TOP TCK, <br />MATCH TUD <br />+ <br />+ <br />f <br />, <br />HEADER - <br />SEE SEE PLAN <- <br />& SCHEDULE <br />HEADER ATTACHMENT EACH <br />SIDE OF DOUBLE STUD <br />HEADER <br />GAUGE (SEE <br />PLAN) <br />- <br />(2) C4 x 2 1/2'. x 16 GA <br />---- <br />(2) ROWS (3) #12 SCREWS (6 TOTAL) <br />(2) C4 x 2" x 12 GA <br />(2) ROWS (3) #12 SCREWS (6 TOTAL) <br />DOUBLE „C„- <br />STUDS, BACK <br />(2) ROWS (4) #12 SCREWS (8 TOTAL) <br />(2) C6 x 21/2" x 14 GA <br />(2) C8 x 2 1/2" x 12 GA <br />(2) ROWS (5) #12 SCREWS (1.0 TOTAL) <br />TO BACK, SEE <br />PLAN. <br />(2) C10 x 2 1/2" x 12 GA <br />(2) ROWS (7) #12 SCREWS (14 TOTAL) <br />(2) C12 x 4" x 12 GA <br />(2) ROWS (7) #12 SCREWS (14 TOTAL) <br />0.2h <br />0.6h <br />(2 <br />(3) <br />REINFORCED MASONRY NOTES: <br />IMPORTANT: <br />SPECIAL INSPECTION IS REQUIRED FOR ALL MASONRY CONSTRUCTION. <br />1. ALL MASONRY WALLS SHALL HAVE CELLS REINFORCED AND DOWELED INTO <br />FOUNDATION AS NOTED ON THE DRAWINGS. ALL MASONRY BELOW GRADE SHALL <br />BE GROUTED SOLID. <br />2. REINFORCED CELLS WITH GROUT SHALL BE CONTINUOUS FROM FOUNDATION <br />TO THE TOP OF THE WALL. <br />3. FILL REINFORCED CELLS WITH MECHANCIALLY MIXED GROUT (2,500 PSI MIN.). <br />A. GROUT SHALL CONFORM TO ASTM C-476 (PROPORTION SPECIFICATION). <br />B. GROUT SHALL BE MIXED FOR AT LEAST 5 MINUTES IN MECHANICAL MIXER <br />AND PLACED WITHIN 1 1/2 HOURS FROM THE INITIAL INTRODUCTION OF <br />WATER AND PRIOR TO INTIAL SET. <br />C. BETWEEN GROUT POURS, A HORIZONTAL CONSTRUCTION JOINT SHALL <br />BE FORMED BY STOPPING ALL CMU AT THE SAME ELEVATION AND WITH <br />THE GROUT STOPPING A MINIMUM OF 1 1/2" BELOW A MORTAR JOINT, <br />EXCEPT AT THE TOP OF THE WALL. WHERE BOND BEAMS OCCUR, THE <br />GROUT POUR SHALL BE STOPPED A MINIMUM OF 1/2" BELOW THE TOP OF <br />THE MASONRY. <br />D. CMU WALLS SHALL BE CONSTRUCTED USING LOW -LIFT GROUTING (5'-0" <br />MAX. POUR HEIGHTS). <br />E. ALL EXTERIOR WALLS AND INTERIOR SHEAR WALLS ARE MARKED ON <br />THE PLANS AS (SW). SEE SCHEDULE ON THIS SHEET FOR REINFORCEMENT. <br />4. ALL CONCRETE MASONRY SHALL HAVE A MINIMUM NET AREA COMPRESSIVE <br />STRENGTH (f m) OF 1500 PSI. (MSJC S1.46.26 TABLE 2). <br />5. MORTAR SHALL BE TYPE S-(ASTM 270 TABLE 1 MORTAR PROPORTION <br />SPECIFICATION REQUIREMENTS). <br />A. THICKNESS OF BED JOINTS SHALL BE 3/8" EXCEPT THAT THE THICKNESS <br />OF THE BED JOINT OF THE STARTING COURSE PLACED OVER <br />FOUNDATIONS SHALL NOT BE LESS THAN 1/4" AND NOT MORE THAT 3/4". <br />B. MORTAR SHALL BE MIXED UNTIL MIXTURE IS UNIFORM THOUGHOUT. <br />C. UNUSED MORTAR SHALL BE DISCARDED WITHIN 21/2 HOURS AFTER <br />INITIAL MIXING. <br />6. ALL MASONRY UNITS SHALL CONFORM TO ASTM C-90 AND HAVE A NET AREA <br />COMPRESSIVE STRENGTH OF CONCRETE MASONRY UNITS EQUAL TO 1900 PSI <br />(MSJC S1.46.213 TABLE 2) <br />A. ALL WALLS SHALL BE CONSTRUCTED USING RUNNING BOND (U.N.0). <br />7. REINFORCING STEEL SHALL CONFORM TO ASTM A615-GRADE 60. FOR WELDED <br />REINFORCING USE ASTM A706-GRADE 60. <br />8. ALL MASONRY WALLS SHALL HAVE STANDARD HORIZONTAL (9 GA.) LADDER TYPE <br />REINFORCING @ 16" o.c. JOINT REINFORCEMENT SHALL CONFORM TO ASTM A951. <br />9. COORDINATE REQUIRED TYPE, SIZE, GAUGE, AND SPACING OF STEEL ANCHORS <br />FOR ATTACHMENT OF MASONRY VENEER WITH ARCH. DRAWINGS. <br />10. CONTROL JOINTS IN CONCRETE MASONRY SHALL HAVE A MAXIMUM SPACING <br />OF 25'-0" o.c. (UNO). COORDINATE THE LOCATION OF BRICK EXPANSION JOINTS <br />WITH ARCH. DWGS. <br />11. SLEEVE ALL PLUMBING OR FIRE PROTECTION PIPING THRU CMU WALLS. <br />12. REINFORCING BARS FOR VERTICAL FILLED CELLS SHALL BE LAPPED <br />ACCORDING TO MASONRY LAP LENTH TABLE 1, SEE THIS SHEET. <br />13. COORDINATE EXACT LOCATION AND EXTENT OF ALL OPENINGS IN MASONRY <br />WALLS WITH ARCH. DRAWINGS. <br />14. MINIMUM MASONRY COVER FOR REINFORCING STEEL: <br />A. MASONRY EXPOSED TO WEATHER OR EARTH: <br />2" FOR BARS LARGER THAN #5 <br />11/2" FOR #5 AND SMALLER BARS <br />B. MASONRY NOT EXPOSED TO WEATHER OF EARTH: 11/2" <br />REINFORCED CONCRETE NOTES: <br />1. STRUCTURAL MEMBERS OF REINFORCED CONCRETE SHALL BE CONSTRUCTED IN <br />ACCORDANCE WITH AC1318. <br />2. ALL CONCRETE SHALL HAVE A SLUMP OF 4" (+/-1") AND A MINIMUM 28 DAY COMPRESSIVE <br />STRENGTH: <br />A. FOOTINGS: 3000 PSI (0.50 MAXIMUM WATER/CEMENT RATIO). <br />B. WALLS: 3000 PSI (0.50 MAXIMUM WATER/CEMENT RATIO). <br />C. SLAB ON GRADE: 3000 PSI (540 LBS/CUBIC YARD MINIMUM CEMENTITIOUS MATERIAL) <br />(0.50 MAXIMUM WATER/CEMENT RATIO). <br />3. ALL STEEL REINFORCEMENT SHALL BE ASTM 615-GRADE 60. ALL WELDED STEEL <br />REINFORCEMENT SHALL BE ASTM A706-GRADE 60. WELDED WIRE REINFORCEMNET SHALL BE <br />ASTM A185. ALL WELDED REINFORCEMENT SHALL BE IN ACCORDANCE WITH AWS D1.4. <br />4. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: (UNO) <br />A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" <br />B. CONCRETE EXPOSED TO EARTH AND WEATHER: <br />#5 REBAR AND SMALLER: 1 1/2" <br />#6 REBAR AND LARGER: 2" <br />C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH EARTH. <br />SLABS, WALLS, AND JOISTS: <br />#14 OR #18 REBARS: 1 1/2" <br />#11 REBAR AND SMALLER: 3/4" <br />BEAMS AND COLUMNS: 1 1/2" <br />5. UNLESS NOTED OTHERWISE, CAST IN PLACE CONCRETE SHALL HAVE THE <br />FOLLOWING STEEL ADDED AROUND ALL OPENINGS: <br />245 (LENGTH OF OPENING+ 48") ALONG EACH SIDE OF OPENING AND <br />TWO (2)-#5x5'-O" DIAGONALLY AT EACH CORNER. <br />6. ALL CONCRETE COMPRESSIVE STRENGTH TESTS SHALL BE AVAILABLE AT JOB SITE. <br />7. ALL LAP SPLICE LENGTHS SHALL BE AS SHOWN IN TABLE 2 THIS SHEET <br />0.6h.0.6h <br />t <br />CD <br />O <br />- -{ <br />t <br />-o <br />U I c: <br />l) <br />ROOF PRESSURE ZONES <br />WALL PRESSURE ZONESo.sn <br />COMPONENT <br />AND <br />AREA <br />(SF) <br />CLADDING <br />(MAIN <br />ROOF) <br />REMARKS <br />ZONE <br />ZONE 1' <br />MAX (+) <br />(PSF) <br />MAX (-) <br />(PSF) <br />-34.2 <br />10 <br />100 <br />+16.0 <br />+16.0 <br />+16.0 <br />-34.2 <br />-59.6 <br />ZONE 1 <br />10 <br />100 <br />+16.0 <br />-46.5 <br />10 <br />+16.0 <br />-78.5 <br />ZONE 2 <br />-. <br />100 <br />+16.0 <br />-61.8 <br />10 <br />+16.0 <br />-107.1 <br />ZONE 3 <br />- <br />---- <br />100 <br />+16.0 <br />-73.5 <br />COMPONENT AND CLADDING (WALLS) <br />AREA <br />MAX (+) <br />MAX (-) <br />ZONE <br />REMARKS <br />(SF) <br />(PSF) <br />(PSF) <br />10 <br />+37.4 <br />-40.5 <br />ZONE 4-- <br />100 <br />+31.8 <br />-35.0 <br />10 <br />+37.4 <br />-50.0 <br />ZONE5 <br />- <br />-_-_ <br />100 <br />+31.8 <br />-38.9 <br />WIND TABLE NOTES: <br />1. LOADS BASED ON ASCE 7-16 <br />2. 0.6h=22 FT <br />REINFORCED CONCRETE <br />TENSION LAP SPLICE <br />LENGTHS <br />TABLE 2 <br />(INCHES) <br />BAR SIZE <br />f c=3000 PSI <br />f c=4000 PSI <br />#3 <br />25 <br />21.3 <br />#4 <br />33 <br />29 <br />#5 <br />41 <br />36 <br />#6 <br />49 <br />43 <br />#7 <br />72 <br />62 <br />DRAWING INDEX <br />- <br />Sheet Number <br />--- -- . .. <br />Sheet Name <br />SO.1 <br />GENERAL NOTES & SCHEDULES <br />S1.1 <br />FOUNDATION PLAN <br />S2.1 <br />SECOND FLOOR FRAMING PLAN <br />..... _._. <br />S2.2 <br />- - - <br />THIRD FLOOR FRAMING PLAN <br />S2.3 <br />ROOF FRAMING PLAN <br />LIST OF ABBREVIATIONS <br />FOB: FACE OF BRICK <br />LO: LOW CONDITION <br />FOA: FACE OF ANGLE <br />HI: HIGH CONDITION <br />FOS: FACE OF STUD <br />TOW: TOP OF WALL <br />TOB: TOP OF BEAM <br />SDS: SELF DRILLING SCREW <br />BOC: BOTTOM OF CHANNEL <br />FOC: FACE OF CHANNEL <br />T&B: TOP AND BOTTOM <br />TOR TOP OF FOOTING <br />TOA: TOP OF ANGLE <br />SIM: SIMILAR CONDITION <br />BOA: BOTTOM OF ANGLE <br />W.P.: WORKING POINT <br />LLV: LONG LEG VERTICAL <br />UNO.: UNLESS NOTED OTHERWISE <br />LLH: LONG LEG HORIZONTAL <br />B.P.: BASE PLATE <br />SW: MASONRY SHEAR WALL <br />PAF: POWER ACTUATED FASTENERS <br />TOS: TOP OF SLAB <br />S.F: STEP FOOTING <br />T/COL: TOP OF COLUMN <br />B/COL: BOTTOM OF COLUMN <br />FOT: FACE OF TUBE <br />S2.4 <br />S3.1 <br />S4.1 <br />S4.2 <br />S4.3 <br />S4.4 <br />S5.1 <br />OFFICE FOUNDATION & FRAMING PLANS <br />FOUNDATION DETAILS <br />FRAMING DETAILS <br />FRAMING DETAILS <br />FRAMING DETAILS <br />MASONRY DETAILS & SECTIONS <br />SCHEDULE OF SPECIAL INSPECTIONS <br />LIGHT -GAUGE CEE MEMBER SCHEDULE (MINIMUM PROPERTIES) 1,2 <br />B MEMBER D B d t AREA Ix MOMENT ly MOMENT <br />DESIGNATION (IN.) (IN.) (IN.) GAUG (IN.) (IN.-2) OF INERTIA OF INERTIA <br />o = 4C2xO70 4" 2" 0.799 14 0.07 0.626 1.564 0.371 <br />10 <br />x_____ -- x 4C2xO59 4" 2" 0.773 16 0.059 0.527 1.331 0.314 <br />4C2.5x105 4" 2.5" 0.884 12 0.105 1.043 2.676 0.938 <br />4C2.5xO70 4" 2.5" 0.799 14 0.07 0.696 1.835 0.630 <br />t- -- ------ _ --- .. - - - -- <br />y 4C2.5xO59 4" 2.5" 0.773 16 0.059 0.586 1.560 0.533 <br />4C3.5x105 4" 3.5" 0.884 12 0.105 1.253 3.473 2.112 <br />4C3.5xO70 4" 3.5" 0.799 14 0.07 0.836 2.375 1.414 <br />4C3.5xO59 4" 3.5" 0.773 16 0.059 0_ 704 2.018 1.193 <br />4C4xO70 4" 4" 0.8 14 0.07 0.906 2.646 1.957 <br />6C2.5xO70 6" 2.5" 0.799 14 0.07 0.836 4.687 0.729 <br />6C2.5xO59 6" 2.5" 0.773 16 0.059 0.704 3.971 0.616 <br />6C3x105 6" 3" 0.884 12 0.105 1.358 7.821 1.690 <br />6C3xO70 6" 3" 0.799 14 0.07 0.906 5.302 1.130 <br />6C3xO59 6" 3" 0.773 16 0.059 0.763 4.492 0.953 <br />8C2x105 8" 2" 0.884 12 0.105 1.358 12.012 0.697 <br />8C2xO70 8" 2" 0.799 14 0.07 0.906 8.109 0.468 <br />8C2xO59 8" 2" 0.773 16 0.059 0.763 6.861 0.395 <br />8C2.5x105 8" 2.5" 0.884 12 0.105 1.463 13.649 1.196 <br />8C2.5xO70 8" 2.5" 0.799 14 0.07 0.976 9.210 0.800 <br />8C2.5xO59 8" 2.5" 0.773 16 0.059 0.822 7.791 0.675 <br />1OC2x105 10" 2" 0.884 12 0.105 1.568 20.745 0.741 <br />1OC2xO70 10" 2" 0.799 14 0.07 1.046 13.598 0.497 <br />1OC2xO59 10" 2" 0.773 16 0.059 0.881 11.798 0.419 <br />1OC2.5x105 10" 2.5" 0.884 12 0.105 1.673 23316 1.277 <br />1OC2.5xO70 10" 2.5" 0.799 14 0.07 1.116 15.684 0.853 <br />1OC2.5xO59 10" 2.5" 0.773 16 0.059 0.940 13.256 0.719 <br />1OC3x105 10" 3" 0.884 12 0.105 1.778 25.886 1.995 <br />1OC3xO70 10" 3" 0.799 14 0.07 1.186 17.410 1.330 <br />1OC3.5x105 10" 3.5" 0.884 12 0.105 1.883 28.456 2.912 <br />1OC3.5xO70 10" 3.5" 0.799 14 0.07 1.256 19.135 1.939 <br />12C2.5x105 12" 2.5" 0.884 12 0.105 1.883 36.329 1.340 <br />12C2.5xO70 12" 2.5" 0.799 14 0.07 1.256 24.390 0.894 <br />12C3x105 12" 3" 0.884 12 0.105 1.988 40.043 2.099 <br />12C3xO70 12" 3" 0.799 14 0.07 1.326 26.880 1.398 <br />12C3.5x105 12" 3.5" 0.884 12 0.105 2.093 43.758 3.071 <br />12C4x105 12" 4" 0.884 12 0.105 2.198 47.472 4.275 <br />-- - - -- - <br />NOTES: <br />1. PRIMED STEEL MEMBERS SHALL MEET THE PHYSICAL AND CHEMICAL PROPERTIES OF ASTM A 1011. GRADE 55. <br />2. ZINC -COATED (GALVANIZED) MEMBERS MEET THE PHYSICAL AND CHEMICAL OF ASTM A 653, GRADE 55 AND <br />G60 COATING DESIGNATION AS DESCRIBED IN ASTM A 924. <br />MASONRY LINTEL SCHEDULE <br />0'- 2 7/8"- 0'- 3 1/2" <br />0'- 3 7/8" 0'- 3 1/2" 1611 4 16" <br />X. <br />MQ 81' - O/1 `. <br />, r. <br />- <br />.. <br />,7 <br />811 <br />OPENING WIDTH <br />1211 811 <br />12" <br />MINIMUM <br />MAXIMUM <br />LEDGE ANGLE <br />8" CMU <br />12" CMU <br />8" CMU <br />12" CMU <br />- <br />31-411 <br />L3 1/2 x 3 1/2 x 1/4 <br />2 - #4 <br />2 - #4 <br />- <br />- <br />3'-4" <br />51-4" <br />L3 1/2 x 3 1/2 x 1/4 <br />2 - #5 <br />2 - #5 <br />- <br />- <br />51-411 <br />7'-4" <br />L5 x 3 1/2 x 1/4 <br />- <br />- <br />4- #5 <br />4 - #5 <br />71-411 <br />10'-011 <br />L6 x 4 x 3/8 <br />- <br />- <br />4-#6 <br />4 - #6 <br />10'-0" <br />13'-0" <br />L7 x 4 x 3/11 <br />- <br />- <br />- <br />- <br />1. EXTEND BOND BEAM REINFORCING 24" or 40 Db BEYOND THE EXTENTS OF THE OPENING. <br />VERTICAL <br />REINFORCING AT THE SIDES OF THE OPENING SHALL BE CONTINUOUS <br />THROUGH THE BOND <br />BEAM. <br />PROVIDE KNOCK OUTS IN THE BOTTOM OF THE BOND BEAM BLOCK AS REQUIRED TO ALLOW <br />REINFORCING TO PASS THROUGH. <br />2. SEE DETAIL 7/S4.4 FOR ADDITIONAL REINFORCING AT OPENINGS. <br />3. PROVIDE 8" BEARING FOR STEEL ANGLE LINTELS AT EACH END. <br />� I I <br />I , <br />� I <br />Keystone <br />Structural <br />Engineering <br />Residential & 0xi-nner6al <br />Professional Consultants <br />531 Roselane Street <br />Suite 150 <br />Marietta, GA 30060 <br />(404) 483-6921 <br />GENSF <br />�No. 721V ` <br />• <br />+�O OATEOF <br />; t0Fi1dP'G���, <br />REVISIONS <br />PROJECT <br />Broward <br />Development <br />Climate <br />Controlled <br />Storage <br />ADDRESS <br />6923 Gall Boulevard <br />Zephyrhills, FL 33542 <br />CLIENT <br />Broward <br />Management, <br />LLC <br />ADDRESS <br />1126 South Federal Highway #375 <br />Fort Lauderdale, FL 33316 <br />SHEET TITLE <br />GENERAL <br />NOTES & <br />SCHEDULES <br />Date: <br />01 /20/2022 <br />PROJECT NUMBER <br />21262 <br />SHEET NUMBER <br />S001 <br />