Laserfiche WebLink
PROJECT SUMMARY <br />FLORIDA PRODUCT DATA INDEX <br />ED STAR CKS <br />E <br />o <br />A 4 <br />SH LL CONSTRUCTION <br />GALL BLVD AND DAUGHTERY ROAD <br />�o ZEPHYRHILLS, FL <br />THE SCOPE OF WORK PROPOSED UNDER THIS PERMIT INCLUDES ALL CONSTRUCTION NECESSARY FOR THE SWELL <br />CONSTRUCTION OF A BUILDING (2,515 SF) FOR ASSEMBLY OCCUPANCY. PLANS FOR CONSTRUCTION INCLUDE ALL <br />STRUCTURAL COMPONENTS (EXCEPT FLOOR SLAB) AND FINISHES THAT COMPRISE THE BUILDING ENVELOPE. <br />PLANS ALSO INCLUDE THE NECESSARY UTILITY STUB -INS FOR SANITARY SEWER AND DOMESTIC WATER AND <br />ELECTRICAL POWER. IT 15 ANTICIPATED THAT THE 5TAR5UCK5 INTERIOR FINISH -OUT WILL BE BE CONSTRUCTED <br />SIMULTANEOUSLY, UNDER SEPARATE PERMIT. SAID PLANS AND CONSTRUCTION WILL INCLUDE PERMANENT <br />POWER, EXIT/EMERGENCY LIGHTING, ETC. <br />UNDER THE TERMS OF THE LEASE WITH STARBUCKS, THE LANDLORD WILL BE RESPONSIBLE FOR ADDITIONAL <br />WORK INCLUDING, BUT NOT LIMITED TO, THE INSTALLATION OF ROOFTOP HVAC UNITS. IN ORDER TO FULLY AND <br />ACCURATELY DOCUMENT SUCH WORK, PLANS FOR STARBUGKS INTERIOR FINISH -OUT MUST BE COMPLETED <br />(CURRENTLY IN PRODUCTION BY OTHERS). UPON RECEIPT OF TENANT PLANS, REVISIONS WILL BE MADE TO <br />THESE SHELL DOCUMENTS WHICH WILL FULLY DOCUMENT ALL LANDLORD RESPONSIBILITIES. ACCORDINGLY, <br />REVISIONS WILL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO <br />CONSTRUCTION. IT IS THE LANDLORD'S INTENT TO BEGIN THE PROCESS FOR REVIEW AND PERMIT OF THE <br />SWELL DOCUMENTS PROVIDED HEREIN IN ORDER TO MEET OBLIGATIONS FOR DELIVERY OF THE BUILDING. <br />THE ABOVE -MENTIONED CONSTRUCTION DRAWINGS FOR STARBUCKS INTERIOR FINISH -OUT SHALL BE SUBMITTED <br />TO THE AUTHORITY HAVING JURISDICTION FOR APPROVAL AND PERMIT PRIOR TO CONSTRUCTION (BY OTHERS). <br />PRODl1CT CATEGORY <br />SUB CATEGORY <br />MANUFACTURER <br />R. APPROVAL NO. <br />DATE <br />PAS WAILS <br />ALUM 90(WACTI <br />YKK AP AM,M <br />R-M216-RB <br />02/0709 <br />DQ13i0R DOORS <br />ALUM BJiRW ES VACT) <br />YW AP AMMA <br />R- 4- R4 <br />0Er <br />CD&Emk STR DOORS <br />CECO DOOR PRODUCTS <br />R <br />07/27/15 <br />AOOFNG <br />%G11-fty ROOI7G SYSTHu6 (Tpp) <br />ARESTONE UM PRODUCTS CQ <br />FL102644i12 <br />06/23/15 <br />WNDaVVS <br />PASS TFFU <br />FIEADY ACCESS <br />R 510243 <br />06/23/15 <br />THE PRODUCTS LISTED ABOVE ARE THE BASIS OF DESIGN <br />THE CONTRACTOR SHALL MAKE AVAILABLE TO THE BUILDING INSPECTOR DOCUMENTATION NECESSARY TO <br />VERIFY THAT ALL COMPONENTS REQUIRING PRODUCT APPROVAL PER FS 553.842 ARE IN COMPLIANCE WITH <br />PRODUCT APPROVAL INSTALLATION REQUIREMENTS <br />PROJECT CODE DATA <br />GENERAL NOTES <br />PROJECT TEAM <br />DRAWING INDEX <br />APPLICABLE CODES <br />• FLORIDA BUILDING CODE -BUILDING (6TH EDITION) <br />• FLORIDA BUILDING CODE -ACCESSIBILITY (6TH EDITION) <br />• FLORIDA BUILDING CODE -ENERGY CONSERVATION (6TH EDITION) <br />• FLORIDA BUILDING CODE -FUEL GAS (6TH EDITION) <br />• FLORIDA BUILDING CODE -MECHANICAL (6TH EDITION) <br />• FLORIDA BUILDING CODE -PLUMBING (6TH EDITION) <br />• FLORIDA FIRE PREVENTION CODE (6TH EDITION) <br />• NATIONAL ELECTRIC CODE (2014 EDITION) <br />BUILDING STATISTICS <br />OCCUPANCY GROUP (A-2) ASSEMBLY <br />CONSTRUCTION TYPE TYPE VB, UNPROTECTED <br />FIRE SPRINKLERED NO <br />FIRE ALARM NO <br />ALLOWABLE AREA 61000 SF PER FLOOR <br />PROPOSED AREA 2 515 GROSS SQUARE FT. <br />No. OF STORIES 1 ALLOWED / 1 PROPOSED <br />PROPOSED HEIGHT 40'-0" ALLOWED / 22'-8" (TOP OF PARAPET) <br />OCCUPANT LOAD OCCUPANT LOAD - 72 (PER TENANT'S PLAN 4 CALCULATED LOAD) <br />OCCUPANT LOAD BASED ON MOST RESTRICTIVE VALUES FROM BOTH THE <br />BUILDING AND FIRE CODE. AREAS BASED ON TENANT'S FIXTURE PLAN. THE <br />OCCUPANT LOAD WILL BE FULLY DESCRIBED IN THE TENANTS INTERIOR <br />FINISH -OUT DRAWINGS TO BE SUBMITTED UNDER SEPARATE PERMIT. <br />MAXIMUM TRAVEL DISTANCE 200' (UNSPRINKLERED) <br />MAX. DEAD END CORRIDOR 20' (UNSPRINKLERED) <br />EGRESS WIDTH REQUIRED .2" PER OCCUPANT = .2" X 72 = 14.4" <br />EGRESS WIDTH PROVIDED 1501(THREE EXITS) <br />MINIMUM CORRIDOR WIDTH 36" REQUIRED, NOT APPLICABLE, CORRIDORS TO BE PROVIDED <br />BY TENANT UNDER SEPARATE PERMIT <br />MINIMUM STAIR WIDTH NOT APPLICABLE, SINGLE STORY BUILDING PROPOSED <br />FIRE RATINGS -TABLE 601 PRIMARY STRUCT. FRAMEWORK 0 <br />BEARING WALLS 0 <br />EXTERIOR WALLS AND OPENINGS (SEE BELOW) <br />FIRE DIVISION WALLS N/A <br />INTERIOR BEARING WALLS 0 <br />FLOOR CONSTRUCTION N/A <br />ROOF CONSTRUCTION 0 <br />TABLE 602 - RE I RESISTANCE <br />F RE T GE RATINGS FOR EXTERIOR <br />WALLS BASED ON FIRE SEPARATION DISTANCE * WHERE SEPARATION FROM <br />SEPARATION FIRE WALL OPENING %OPENINGS %OPENINGS PROPERTY LINES EXCEEDS 30 <br />DISTANCE RATING AREA AREA ALLOWED PROPOSED FEET THERE ARE NO LIMITS FOR <br />EAST > 30' 0 * * NL * UNPROTECTED WALL OPENINGS. <br />NORTH > 30' 0 * $ NL * CALCULATIONS FOR WALL AREA, <br />WEST > 30' 0 * * NL * OPENING AREA AND PROPOSED <br />OPENING PERCENTAGES NOT <br />SOUTH > 30 0 * * NL * PROVIDED IN SUCH INSTANCES <br />MIN. FIRE RESISTANCE OF WALLS, PARTITIONS AND OPNG PROTECTIVES <br />SHAFT ENCLOSURES NOT APPLICABLE <br />EXIT ACCESS CORRIDORS NOT APPLICABLE <br />TENANT SEPARATION NOT APPLICABLE <br />OCCUPANCY SEPARATION NOT APPLICABLE <br />FLOOR PENETRATIONS NOT APPLICABLE <br />MINIMUM PLUMBING FIXTURES TOILET ROOMS AND PLUMBING FIXTURES ARE NOT INCLUDED IN THE PROPOSED <br />SCOPE OF WORK (SHELL CONSTRUCTION ONLY). THESE WILL BE PROVIDED BY <br />THE TENANT UNDER SEPARATE PERMIT. <br />CONSTRUCTION DRAWINGS FOR THE INTERIOR FINISH -OUT DOCUMENTS SHALL <br />BE PROVIDED BY THE TENANT AND SUBMITTED TO THE AUTHORITY HAVING <br />JURISDICTION FOR APPROVAL AND PERMIT PRIOR TO CONSTRUCTION. <br />1. ALL WORK SHALL BE PERFORMED IN A FIRST CLASS, WORKMANLIKE MANNER ACCORDING TO BEST TRADE <br />PRACTICES. MATERIALS AND EQUIPMENT SHALL BE NEW, AND ALL CONSTRUCTION SHALL BE IN GOOD AND <br />USABLE CONDITION AT THE DATE OF COMPLETION AND/OR OPENING OF THE DEMISED PREMISES FOR BUSINESS. <br />2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL AUTHORITIES OR <br />AGENCIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE TENANT'S DRAWINGS AND SPECIFICATIONS. <br />3. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS OF THE SITE. DISCREPANCIES SHALL BE REPORTED TO <br />THE ARCHITECT PRIOR TO PROCEEDING W/ CONSTRUCTION. <br />4. TEMPORARY ELECTRIC POWER AND LIGHTING WILL BE PROVIDED AS REQUIRED. THE TEMPORARY SERVICE MUST <br />MEET ALL APPLICABLE CODE AND SAFETY REQUIREMENTS. <br />5. THE GENERAL CONTRACTOR SHALL PROPERLY PROTECT THE WORK FOR PUBLIC SAFETY AND AGAINST <br />ACCIDENTS, WEATHER OR ANY OTHER HAZARD WITH LIGHTS AND GUARD RAILS OR BARRICADES AS <br />APPLICABLE. <br />6• ALL EXITS SHALL BE MAINTAINED AND SHALL BE OPERABLE FROM THE INSIDE W/OUT SPECIAL KNOWLEDGE OR <br />EFFORT. <br />7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER LOCATION AND SIZE OF OPENINGS FOR ALL TRADES <br />CONSTRUCTION DOCUMENTS, INCLUDING SHOP <br />AND SHALL COORDINATE ALL CONSTRUCTION AS INDICATED BY THE7 <br />DRAWINGS REVISED BY THE ARCHITECT. <br />8. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY AND REQUIRED PERMITS, FEES, DEPOSITS, ETC. <br />9. A FIRE EXTINGUISHER 15 REQUIRED DURING CONSTRUCTION. THE CONTRACTOR SHALL MAKE ALL PERSONNEL <br />AWARE OF ITS LOCATION. <br />10• THE CONTRACT DOCUMENTS HAVE BEEN PREPARED TO BE COMPLEMENTARY. WHAT 15 REQUIRED BY THE DRAWINGS <br />SHALL BE REQUIRED BY THE SPECIFICATIONS, AND CONVERSELY. IN THE CASE OF DISCREPANCIES BETWEEN THE <br />TWO DOCUMENTS CONCERNING QUALITY AND/OR QUANTITY, THE CONTRACTOR SHALL INCLUDE THE BETTER <br />QUALITY AND/OR GREATER QUANTITY UNLESS OTHERWISE DIRECTED IN WRITING BY THE ARCHITECT. WHERE <br />SPECIFICATIONS HAVE BEEN OMITTED FOR PARTICULAR ITEM(S), THE CONTRACTOR SHALL EMPLOY THE HIGHEST <br />STANDARDS ESTABLISHED BY THE MANUFACTURER OF THE ITEM(5) AS THE GUIDELINES FOR PRODUCT HANDLING, <br />INSTALLATION OR ERECTION AND PROTECTION OF THE COMPONENT ONCE IN PLACE. <br />DEVELOPER ARCHITECT <br />EPIC DEVELOPMENT FWH ARCHITECTS, INC. <br />907 S. FT. HARRISON AVE. 3336 GRAND BLVD., SUITE 201 <br />SUITE 102 HOLIDAY, FLORIDA 34690 <br />CLEARWATER, FLORIDA 33756 ATTN: ADRIENNE BAUER <br />ATTN: SUE SUGEVIC TEL: (727) 815-3336 <br />TEL: (727) 210-1900 FAX: (727) 815-3337 <br />CIVIL ENGINEER STRUCTURAL ENGINEER <br />AVID GROUP ACG PROFESSIONAL ENGINEERING <br />2300 CURLEW RD 1bg12 MELISSA ANN DRIVE <br />SUITE 201 LUTZ, FLORIDA 33558-8049 <br />PALM HARBOR, FLORIDA 34693 ATTN: ALAN GUENTHER <br />ATTN: JORGE HERNANDEZ P.E. TEL: (813) 963-1906 <br />TEL: (727) 789-9500 FAX: (813) 489-4666 <br />MECHANICAL A PLUMBING ELECTRICAL ENGINEER <br />STEPANEK-LEWIS AND ASSOCIATES, INC. CNEHAYEB 4 ASSOCIATES <br />2257 TWELVE OAKS WAY, SUITE 103 3702 AZEELE STREET <br />WESLEY CHAPEL, FLORIDA 33544 TAMPA, FLORIDA, 33607 <br />ATTN: MATT LEWIS ATTN: SOUNEIL CHEHAYEB <br />TEL: (813) 991-1248 TEL: (813) 876-1415 <br />FAX: (813) 876-0913 <br />BUILDING DEPARTMENT <br />CITY OF ZEPHYRNILLS <br />5335 8TH STREET <br />ZEPHYRHILLS, FL 33542 <br />ATTN: COMMERCIAL PLAN REVIEW <br />TEL: (813) 780-0020 <br />SHT. NO. <br />DRAWING TITLE <br />REVISION <br />• <br />MAUHM <br />LOG <br />NHM <br />AO <br />INDEX, VICINITY MAP AND NOTES <br />CIVIL <br />1 <br />COVER SHEET <br />2 <br />NOTES t SPECIFICATIONS <br />z <br />3 <br />DEMOLITION PLAN <br />w <br />(a <br />4 <br />HORIT.ONTAL CONTROL PLAN <br />w <br />>w Q�= <br />5 <br />PAVING, GRADING AND DRAINAGE PLAN <br />awc <br />6 <br />UTILITY PLAN <br />? a <br />N PDES NOTES <br />3 wN <br />8 <br />NPDES DETAILS <br />-' <br />9 <br />SITE DETAILS <br />Z �i <br />w <br />10 <br />UTILITY DETAILS <br />>_ <br />Li <br />LANDSCAPE PLAN <br />w o <br />� i w <br />L2 <br />LANDSCAPE DETAILS <br />`� z <br />L3 <br />LANDSCAPE NOTES <br />z f a <br />Q w U_ <br />IR <br />IRRIGATION PLAN <br />o w a <br />IRI <br />IRRIGATION NOTES <br />Q a <br />LU <br />N <br />, ,; <br />A <br />z <br />PERMIT NOTES <br />WIND DESIGN CRITERIA <br />� o <br />w <br />, � <br />> m <br />u N <br />SIGNAGI& <br />SIGNAGE DEPICTED IN THESE DOCUMENTS ARE FOR COORDINATION PURPOSES ONLY. IT SHALL BE UNDERSTOOD <br />THAT ALL EXTERIOR BUILDING MOUNTED AND SITE SIGNAGE WILL BE PERMITTED SEPARATELY, EITHER BY THE <br />LANDLORD'S SIGN VENDOR OR BY INDIVIDUAL TENANT SIGN VENDORS. AT THAT TIME, COMPLETE DETAILS <br />INCLUDING, BUT NOT LIMITED TO, SIGN FABRICATION, SIGN INSTALLATION, SIGN AREA AND QUANTITIES, ETC. <br />WILL BE SUBMITTED FOR PERMIT REVIEW AND APPROVAL PRIOR TO COMMENCEMENT OF WORK. <br />SHOP DRAWINGSi <br />IT SHALL BE UNDERSTOOD THAT ENGINEERED SHOP DRAWINGS FOR PRE-ENGINEERED ROOF JOISTS SHALL BE <br />PROVIDED BY MANUFACTURER AND SUBMITTED TO THE BUILDING DEPARTMENT BY THE GENERAL CONTRACTOR. <br />SAID SHOP DRAWINGS SHALL CONTAIN A STATEMENT FROM THE PROFESSIONAL OF RECORD STATING THAT <br />HE/SHE HAS REVIEWED THE DRAWINGS AND THAT DRAWINGS ARE IN COMPLIANCE WITH HISIHER DESIGN BY <br />NAMING THE MANUFACTURER JOB NUMBER AND DATE OF THE PLANS. <br />' <br />PERMITSi <br />SEPARATE PERMITS MAY BE REQUIRED FOR THE AWNINGS AND TRASH ENCLOSURES. SAID PERMITS SHALL BE <br />OBTAINED PRIOR TO COMMENCEMENT OF WORK ON ANY OF THESE COMPONENTS. <br />1 ULTIMATE WIND SPEED = 140 MPH (FBC FIGURE 1609A) <br />2• WIND EXPOSURE "B" <br />3. BUILDING RISK CATEGORY 11 (PER FBC TABLE 1604.5) <br />4• INTERNAL PRESSURE COEFFICIENT <br />(GCpi) = +/- 0.18 TOTALLY ENCLOSED <br />' (PER ASGE 7-10) <br />5. COMPONENTS AND CLADDING - REFER TO STRUCTURAL DRAWINGS, 5NEET 50.1 FOR WIND DESIGN CRITERIA <br />ARCHITECTURAL <br />AO.1 <br />SPECIFICATIONS <br />AO.2 <br />SPECIFICATIONS <br />AO.3 <br />KEYNOTE SCHEDULE <br />• <br />AS.1 <br />ARCHITECTURAL SITE PLAN <br />• <br />AS.2 <br />MISCELLANEOUS SITE DETAILS <br />• <br />A1.0 <br />FLOOR PLAN AND NOTES <br />• <br />ALL <br />ROOF PLAN <br />• <br />A1.2 <br />ROOF DETAILS <br />A1.3 <br />CANOPY AND AWNING DETAILS <br />A2.0 <br />REFLECTED CEILING PLAN <br />A3.0 <br />EXTERIOR ELEVATIONS AND EXTERIOR FINISH SCHEDULE <br />• <br />A3.1 <br />EXTERIOR ELEVATIONS <br />• <br />A4.0 <br />FRAME OPENING SCHEDULE <br />A4.1 <br />FRAME OPENING DETAILS <br />A4.2 <br />ENLARGED PLAN DETAILS <br />A5.0 <br />WALL SECTIONS <br />FINISH NOTES <br />FINISH <br />VICINITY MAP <br />A5.1 <br />WALL SECTIONS <br />WALL SECTIONS <br />1. SUBCONTRACTORS MUST EXAMINE EACH INSTALLATION AREA FOR CONDITIONS THAT MAY INTERFERE WITH <br />PROPER, TIMELY, OR ACCEPTABLE COMPLETION OF THE WORK AND SHALL NOTIFY THE GENERAL CONTRACTOR OF <br />UNACCEPTABLE CONDITIONS BEFORE FINISH MATERIAL INSTALLATION. PERFORMANCE OF FINISH WORK INDICATES <br />ACCEPTANCE OF ALL SUBSTRATE CONDITIONS AND ASSUMPTION OF RESPONSIBILITY FOR COMPLIANCE WITH <br />MATERIAL INSTALLATION QUALITY STANDARDS. <br />2. CONTRACTOR TO PREPARE FLOOR SUBSTRATE CONDITIONS WHERE APPLICABLE AS NECESSARY WHERE <br />( ) <br />DIFFERENT MATERIALS ABUT TO ENSURE SMOOTH AND GRADUAL TRANSITION, FREE FROM TRIP HAZARD OR <br />EXCESSIVE ELEVATION CHANGE. PROVIDE TRANSITION EDGES AS APPROPRIATE. SUBMIT ACCESSORY OPTIONS, <br />INCLUDING AVAILABLE FINISH AND COLOR SELECTIONS FOR APPROVAL. <br />i- i n S' o f. CLEAN � � � S' 15NES <br />3 Hn EPE NO FLOOR FINhSN IS REQUIRED CONTRACTOR OF HALL i ROVIDE A CLEAN SHOO T I SURFACE FOR FIN <br />FROVIDED 3Y TENANT. <br />4. FOR PAINTED / STAINED SURFACES, ADHERE TO INDUSTRY STANDARDS AND USE PRIMERS, PAINT, STAINS, <br />AND OTHER PRODUCTS AS APPROPRIATE FOR THE CONDITIONS AND SUBSTRATES TO WHICH FINISHES ARE BEING <br />APPLIED. <br />5. ALL GWB SURFACES THAT ARE NOT TO BE PAINTED UNDER THE SCOPE OF THIS CONTRACT (PAINT BY <br />TENANT) ARE TO BE TAPED, MUDDED AND SANDED. WALLS SHALL BE LEFT IN A CONDITION READY FOR <br />TEXTURE AND PAINT BY TENANT. <br />6. ACCEPTABLE PAINT MANUFACTURERS ARE BENJAMIN MOORE OR SHERWIN WILLIAMS. REFER TO <br />SPECIFICATIONS FOR TYPE OF PAINT. <br />7. ALL COLOR SELECTIONS, IF NOT INDICATED ON PLANS, SHALL BE MADE BY THE TENANT FROM THE' <br />MANUFACTURER'S STANDARD SELECTIONS PROVIDED BY THE CONTRACTOR, UNLESS OTHERWISE NOTED. <br />{ 4sF} s5 <br />_ <br />_ M.s, F>„ . •_- s - r-..: .3.x g <.:f, .. ;' <br />= <br />::..,..,...u,... `"r <br />P <br />" t <br />? v a <br />�t�.�<�>z� ,€=1:r <br />,. <br />SITE <br />µ <br />""`"`'' W <br />NCRT1 <br />„r <br />:., <br />r _ } <br />z FnE <br />Go cle <br />STRUCTURAL <br />50.1 <br />STRUCTURAL NIXES <br />51.1 <br />FOUNDATION PLAN <br />52.1 <br />ROOF FRAMING PLAN <br />• <br />S3.1 <br />WALL SECTIONS <br />• <br />54.1 <br />SECTIONS AND DETAILS <br />54.2 <br />SECTIONS AND DETAILS <br />MECHANICAL <br />M1.0 <br />MECHANICAL ROOF PLAN AND SPECIFICATIONS <br />• <br />M2.0 <br />MECHANICAL DETAILS AND SCHEDULES <br />• <br />PLUMBING <br />P1,0 <br />PLUMBING PLAN AND SPECIFICATIONS <br />• <br />P2.0 <br />PLUMBING SCHEDULES, RISERS AND DETAILS <br />• <br />ELECTRICAL <br />ALL WALL AND CEILING FINISHES SHALL COMPLY WITH FLORIDA FIRE PREVENTION CODE SECTION 10.2.3 <br />AND SHALL BE CLASS A OR B IN EXITS AND ENCLOSED CORRIDORS FURNISHING ACCESS TO EXITS; AND <br />CLASS A, CLASS B OR CLASS C IN OFFICES. <br />INTERIOR FLOOR FINISHES SHALL COMPLY WITH FLORIDA FIRE PREVENTION CODE SECTION 10.2.7 AND <br />SHALL BE CLASS I OR CLASS 11 IN CORRIDORS AND EXITS <br />E0.0 <br />ELECTRICAL PROJECT NOTES AND LEGEND <br />EI,O <br />ELECTRICAL SITE PLAN <br />• <br />El,l <br />PHOTOMETRIC SITE PLAN <br />• <br />E1.2 <br />FIXTURE INFORMATION <br />• <br />E2.0 <br />LIGHTING AND POWER PLANS <br />• <br />E3.0 <br />POWER RISER DIAGRAM <br />• <br />E4.0 <br />ELECTRICAL SPECIFICATIONS <br />UCAP 19Ii UUUJ3VV <br />3336 Grand Blvd. Suite 201 <br />Holiday, Florida 34690 <br />Ph. 727. 815. 3336 <br />Fax 727. 815. 3337 <br />epic <br />.. <br />907 S. FT. HARRISON AVENUE <br />SUITE 102 <br />` <br />CLEARWATER, FL 33756 <br />727-210-1900 <br />w <br />; <br />TO THE BEST- OF.TNE KNOWLEDGE OF <br />NE ARCHIT INEERS, PLAN <br />AND ` WITH THE <br />AP INIMUM CODES <br />APPLICABLE MINI ;FIRE <br />F; P ' SAFETY STANDA <br />�D <br />E R <br />FL License No. AR0015323 <br />0 <br />} <br />::floc«�rx�i?�� _mm' ° 3 ;,,£831\y�s�..�v= ; <.. � �;^•c�a <br />t <br />Z <br />U Q O <br />LLl <br />�- LL. <br />cji <br />3 <br />J <br />-, <br />:D J <br />G. <br />O 0 <br />QV ON <br />> <br />J m <br />J <br />cn <br />�z� <br />TW a <br />0 <br />U) <br />04.06.18 <br />date <br />Mx <br />17060 <br />comm. no. <br />INDEX, <br />VICINITY MAP <br />AND NOTES <br />AO <br />