H.V'.A.C. GENERAL NOTES: <br />ALL WORK SHALL BE DONE IN ACCORDANCE WITH FBC-2010, 2006 NFPA-101, 2006 NFPA-1, 2008 NFPA-70. <br />1.ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL <br />BE FULLY OPERATIVE AND ACCEPTANCE BY THE OWNER AND/OR ARCHITECT MUST BE CONDITION OF THE CONTRACT. SUBMIT SHOP DRAWINGS <br />ON ALL EQUIPMENT, FOR REVIEW PRIOR TO PURCHASING. <br />2. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES IN ORDER TO AVOID CONFLICTS. NO CHARGES WILL BE ACCEPTED <br />UNLESS A PRIOR WRITTEN APPROVAL HAS BEEN ISSUED BY THE OWNER/ARCHITECT. <br />3. THE CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE WITH EXISTING CONDITIONS. PRIOR TO INSTALLING EQUIPMENT <br />AND/OR FABRICATING DUCTWORK, A.C. CONTRACTOR SHALL CHECK THAT THERE IS SUFFICIENT CLEARANCES FOR EQUIPMENT, DUCTWORK, ETC, <br />AND ALSO TO AVOID ANY INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. <br />4. DRAWINGS ARE DIAGRAMMATIC ILLUSTRATIONS. DO NOT SCALE DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT. PIPING, DUCTWORK, <br />ETC. THESE DRAWINGS ARE NOT INTENDED TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR SHALL FURNISH AND <br />INSTALL ALL ITEMS REQUIRED FOR A COMPLETE ACCEPTABLE WORKING SYSTEM. <br />5. CONTRACTOR WILL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTS. <br />6. INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST ASHRAE GUIDE. ALL MATERIALS <br />SHALL BE NEW AND SHALL BEAR UNDERWRITER'S LABEL WHERE APPLICABLE. <br />7. AIR FILTERS SHALL BE INSTALLED ON ALL RETURN AIR EQUIPMENT INLETS. PROVIDE AN EXTRA FILTER, INSTALL AT END OF <br />CONSTRUCTION. <br />8. ALL REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE <br />FOR THE DURATION OD THE WORK. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE NATIONAL, <br />STATE, AND LOCAL CODES, RULES, AND ORDINANCES. <br />9. PROVIDE MAIN CONDENSATE DRAIN AND AUXILUARY DRAIN PAN (AUXILIARY DRAIN PAN SHALL BE EQUIPPED WITH A WATER -LEVEL <br />DETECTION DEVICE THAT WILL SHUT OFF THE EQUIPMENT SERVED PRIOR TO OVERFLOW OF THE PAN AS PER FMC 2010 SECTION 307.2.3) <br />FOR ALL AIR CONDITIONING UNITS AND DRAIN TO EXTERIOR PERMEABLE SOIL OR AS SHOWN ON THE PLANS. <br />10. AIR CONDITIONING CONDENSATE PIPING AND FITTINGS SHALL BE PVC OR DWV ( ASTM-D2662). COPPER IN PLENUM AREAS. ALL INTERIOR <br />CONDENSATE PIPING IN UNCONDITIONED SPACES SHALL BE WRAPPED WITH A MINIMUM 1 /2" SELF SEALING INSULATING FOAM JACKET. THE <br />CONTRACTOR SHALL PROVIDE ALL NECESSARY CONTROLS FOR THE OPERATION OF THE HVAC SYSTEM. <br />11. NA <br />12. THERMOSTAT MUST BE PROGRAMMABLE TO BE ABLE TO SET THE TEMPERATURE BACK (OR OFF) WHEN SPACE IS t3WCCUr^TE0 Of? AT <br />OTHER TIMES AS NEEDED BY USER. <br />13. ALL MATERIAL EXPOSED WITHIN PLENUM MUST BE NON COMBUSTIBLE OR RATED 25/50 FLAME SPREAD. <br />14. NA <br />15. ALL VENTILATION DUCTWORK SHALL BE GALVANIZED SHEET METAL <br />16. NA <br />17. HANGERS SHALL BE PROVIDED IN ACCORDANCE WITH S.M.A.C.N.A. RECOMMENDATIONS, <br />18. AIR DISTRIBUTION ACCESSORIES SHALL BE AIR GUIDE, ANEMOSTAT, TITUS, OR APPROVED EQUAL ALL SUPPLY A.C. DUCT ELBOWS MUST <br />BE FURNISHED WITH APPROVED TURNING VANES. BRANCH TAKEOFFS MUST BE PROPORTIONAL SPLITS. <br />19. THE OWNER SHALL APPROVE THE FINISH COLOR OF ALL EXPOSED AIR DISTRIBUTION DEVICES, <br />20. PROVIDE FIRE DAMPERS IN ALL DUCTS PASSING THROUGH FIRE DIVISION ASSEMBLIES. FIRE DAMPERS MUST HAVE FIRE RATING EQUAL TO <br />OR GREATER THAN THE PENETRATED ASSEMBLY RATING, FIRE DAMPER INSTALLATIONS SHALL COMPLY WITH ALL LOCAL CODES. PROVIDE <br />ACCESS PANEL TO ALL FIRE DAMPERS. <br />21. ELECTRIC STRIP HEATERS SHALL BE BLAST COIL TYPE WITH NICKEL CHROMIUM WIRE AND INSULATING BUSHINGS FACTORY MOUNTED AND <br />WIRED INCLUDING ALL HEAT LIMITERS, HOGH LIMIT SWITCHES, AND CONTRACTORS IN ACCORDANCE WITH THE 'NATIONAL ELECTRIC CODE". <br />22. EXHAUST FANS SHALL HAVE THE CAPACITIES AS STATED ON THE DRAWINGS AND BE PROVIDED WITH BACK DRAFT DAMPER, BIRD SCREEN. <br />23. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD NOT LESS THAN 1 YEAR <br />FROM THE DATE OF ACCEPTANCE, UNLESS OTHERWISE NOTED. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL <br />CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIRS OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED OR <br />IS NOT OPERATING PROPERLY. <br />24. ARCHITECTURAL AND/OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO REVISIONS FOR SUBSTITUTIONS BY THE CONTRACTOR <br />SHALL BE PAID FOR BY THE CONTRACTOR. <br />25. AIR DISTRIBUTION SYSTEM TESTING, ADJUSTING AND BALANCING. A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER OR <br />THE DESIGNATED REPRESENTATIVE OF THE BUILDING OWNER FOR HVAC SYSTEMS SERVING ZONES WITH A TOTAL CONDITIONED AREA, <br />EXCEEDING 5000 SQUARE FEET. AIR DISTRIBUTION SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY AN ENGINEER LICENSED IN <br />THIS STATE OR A COMPANY OR INDIVIDUAL HOLDING A CURRENT CERTIFICATION FROM A RECOGNIZED TESTING AND BALANCING AGENCY <br />ORGANIZATION IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING STANDARDS. <br />EXCEPTIONS: <br />1. BUILDINGS WITH COOLING OR HEATING SYSTEM CAPACITIES OF 15 TONS OR LESS PER SYSTEM MAY BE TESTED AND BALANCED BY A <br />MECHANICAL CONTRACTOR LICENSED TO DESIGN AND INSTALL SUCH SYSTEM(S). <br />2. BUILDINGS WITH COOLING OR HEATING SYSTEM CAPACITIES OF 65,000 BTU/H OR LESS PER SYSTEM ARE EXEMPT FROM THE <br />REQUIREMENTS OF THIS SECTION. <br />AIR SYSTEM BALANCING SHALL COMPLY WITH FBC 2010 ENERGY CONSERVATION SECTION 503.2.9.1 <br />26. AS PER FBC 2010 ENERGY CONSERVATION SECTION 503.2.9.3, AN OPERATING AND MAINTENANCE MANUAL SHALL BE PROVIDED TO <br />THE BUILDING OWNER BY THE MECHANICAL CONTRACTOR, THE MANUAL SHALL INCLUDE, AT LEAST, THE FOLLOWING: <br />1. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. <br />2. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. <br />3. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL <br />SEQUENCE DESCRIPTIONS. DESIRED OR FIELD -DETERMINED SET POINTS SHALL BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT <br />CONTROL DEVICES OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. <br />4. A COMPLETE WRITTEN NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. <br />27. ALL PIPING SERVING AS PART OF A HEATING OR COOLING SYSTEM SHALL BE THERMALLY INSULATED IN ACCORDANCE WITH FBC <br />2010 ENERGY CONSERVATION TABLE 503.2.8. <br />28. IF THERE ARE ANY CHANGES IN ENGINEER'S DRAWINGS, IN DESIGN OR IN EQUIPMENT, WITHOUT ENGINEER'S CONSENT, THE A.c. <br />CONTRACTOR SHALL ASSUME ALL RESPONSIBILITIES FOR THE PROJECT. <br />29. SMOKE DETECTORS ARE REQUIRED ON ALL PRIMARY AIR CONDITIONING SYSTEMS WHERE TOTAL AIR VOLUME EXCEEDS 2,000 C.F.M. <br />(FBC-MECHANICAL 2010, SECTION 606.2.1) A DUCT ACCESS DOOR IS REQUIRED TO ACCESS THE DETECTOR. THE SYSTEM SHALL BE WIRED <br />SO AS WHEN THE DUCT SMOKE DETECTOR DETECTS SMOKE, IT SHALL STOP THE AC SUPPLY FAN AND CAUSE A VISUAL AND AUDIBLE <br />SIGNAL IN A NORMALLY OCCUPIED LOCATION. ALSO, THE DETECTOR SHALL INDICATE A TROUBLE CONDITION EITHER VISUALLY OR AUD`'=BLY IN <br />THE NORMALLY OCCUPIED LOCATION, AND BE IDEN11FIED AS AIR DUCT DETECTOR TROUBLE. NFPA 90A, 4-4.4.3 <br />(THE TESTER SHOULD BE EQUIPPED WITH AN LED LIGHT TO INDICATE TROUBLE). <br />30. AS PER FBC 2010 ENERGY CONSERVATION SECTION 503.2.5.4 (SHUTOFF DAMPER CONTROLS) <br />PROVIDE MOTORIZED DAMPERS FOR O/A INTAKE FOR AHU. CONNECT MOTORIZED DAMPER TO TIME CLOCK TO CLOSE OUTSIDE AIR INTAKE <br />AUTOMATICALLY WHEN THE SPACE SERVED IS NOT IN USE (OFF BUSINESS HOURS). <br />31. GRAVITY HOODS, VENTS, AND VENTILATORS. ALL OUTDOOR AIR SUPPLY AND EXHAUST HOODS, VENTS, AND VENTILATORS SHALL BE <br />EQUIPPED WITH DAMPERS THAT WILL AUTOMATICALLY SHUT WHEN THE SPACES SERVED ARE NOT IN USE. <br />EXCEPTION: VENTILATION SYSTEMS SERVING UNCONDITIONED SPACES. <br />32. NA <br />33. AS PER FBC-301.4 ALL APPLIANCES REGULATED BY THIS CODE SHALL BE LISTED AND LABELED UNLESS OTHERWISE APPROVED IN <br />ACCORDANCE WITH SECTIONS 301.4.1 THROUGH 301.4.4. <br />34. AS PER FMC-304.10 GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EQUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE <br />SERVICE AND ROOF HATCH OPENINGS ARE LOCATED WITHIN 10 FT. OF ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE <br />OR OPEN SIDE IS LOCATED MORE THAN 30" ABOVE THE FLOOR, ROOF OR GRADE BELOW. <br />35. AS PER 306.5.1 SLOPED ROOFS. WHERE APPLIANCES, EQUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE INSTALLED <br />ON A ROOF HAVING A SLOPE OF THREE UNITS VERTICAL IN 12 UNITS HORIZONTAL OR GREATER AND HAVING AN EDGE MORE THAN 30" <br />ABOVE GRADE AT SUCH EDGE A LEVEL PLATFORM SHALL BE PROVIDED ON EACH SIDE OF THE APPLIANCE TO WHICH ACCESS IS REQUIRED <br />FOR SERVICE, REPAIR OR MAINTENANCE. THE PLATFORM SHALL BE NOT LESS THAN 30" IN ANY DIMENSION AND SHALL BE PROVIDED WITH <br />GUARDS. THE GUARDS SHALL EXTEND NOT LESS THAN 42"ABOVE THE PATFORM, SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE <br />OF A 21" DIAMETER SPHERE AND SHALL COMPLY WITH THE LOADING REQUIREMENTS FOR QUARDS SPECIFIED IN THE FBC. <br />36. ANY INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 1OFf. FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE. <br />37. ALL COOKING APPLIANCES THAT ARE DESIGNED FOR PERMANENT INSTALLATION SHALL BE LISTED , LABELED AND INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTION. <br />38. ROOF MOUNTED MECHANICAL UNITS SHALL BE MOUNTED ON CURBS RAISED A MINIMUM OF 8 INCHES (203 MM) <br />ABOVE THE ROOF SURFACE, OR WHERE ROOFING MATERIALS EXTEND BENEATH THE UNIT, ON RAISED EQUIPMENT SUPPORTS <br />PROVIDING A MINIMUM CLEARANCE HEIGHT IN ACCORDANCE WITH TABLE 1509.7. <br />TABLE 1509.7 CLEARANCE BELOW RAISED ROOF MOUNTED MECHANICAL UNITS <br />WIDTH OF MECHANICAL UNIT (INCHES) <br />SURFACES (INCHES) <br /><24 /24<36 / 36 < 48 / 48 < 60 / > 60 <br />14' 18" 24" 30" M. <br />39. ROOF TOP A/C UNIT CURB SHALL BE MINIMUM 14 GAUGE (HURRICANE RATED CURB). <br />40. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND INFORM THE PROJECT ENGINEER AND ARCHITECT OF ANY <br />DISCREPANCY BETWEEN THESE PLANS AND THE EXISTING CONDITIONS. THE CONTRACTOR SHALL INCLUDE IN HIS BID TO CORRECT SUCH <br />CONDITION AS DIRECTED. THE ENGINEER AND ARCHITECT ARE NOT RESPONSIBLE FOR ANY ADDITIONAL COSTS RESULTING FROM VERIFIABLE <br />EXISTING CONDITIONS DISCOVERED AFTER CONTRACT HAS BEEN AWARDED. <br />NOTE: <br />PROVIDE FLOAT SWITCH, TO BE INSTALLED <br />IN THE PRIMARY DRAIN PAN OF THE UNIT. <br />NOTE: <br />ROOF MOUNTED MECHANICAL UNITS <br />SHALL BE MOUNTED ON CURBS <br />RAISED A MINIMUM OF 8 INCHES <br />ABOVE THE ROOF SURFACE <br />4-1/2 X 5/16 SCREW <br />8" Q.C. <br />END SCREWS TO BE <br />OUT PLACED WITHIN 6" OF <br />CORNER. <br />' <br />GALV METAL STRAP W/ NEOPRENE GASKET FASTEN <br />TO PIPE STAND <br />PVC CONDENSTATE SEE MECH. PLANS <br />FOR CONTINUATION <br />RTU TO CURB ATTACHMENT & DRAIN <br />NTSC <br />S. <br />NEW 4 x 4 x 1/4' STEEL <br />OPTION 1. ANGLES (6'-0" O.C. MAX) FULLY <br />CONNECT PREFABRICATED RTU CURB WELDED TO EX. BAR JOISTS <br />DIRECTLY TO STEEL ANGLES / BAR <br />JOIST W/ MIN. 3/8' DIAM. S.S. BOLTS <br />W/ WASHERS THRU FLANGE OF CURB <br />AND STEEL ANGLE / BAR JOIST <br />BELOW AT ALL CORNERS AND BALANCE <br />@ 12" O.C. MAX ALL 4 SIDES <br />OPTION 2. <br />WELD CURB TO STEEL ANGLES 'FRAME" NOTE' <br />WITH 1/2" BEAD EVERY 6 INCHES. CURB MUST BE INSULATED FROM INSIDE. <br />CURB TO ROOF JOIST ATTACHMENT DETAIL <br />NTSC <br />RELIEF VENT SAME SIZE AS CONDENSATE LINE <br />CONC. COVER WITH LIFT HANDLE-� <br />GRADE <br />NATURAL EARTH <br />24"4 x 36" LONG <br />GALVANIZED STEEL <br />NOTES: <br />1. STABALIZER STONES MIN. ONE HALF CUBIC YARD <br />DRYWELL DETAIL <br />NTSC <br />PVC CONDENSATE DRAIN <br />LINE SEE PLAN FOR SIZE <br />SEAL WITH SILICONE <br />CAULK (OR EQ.) <br />THE EXCAVATED PIT SHALL <br />BE COMPLETELY FILLED <br />WITH COARSE GRAVEL <br />2"0 CLEAN STONES <br />(STABAUZED) <br />�c=o3C' <br />GASKET, TYP. _ <br />SCHEDULED RTU, SEE MECH. DWGS. <br />Ff <br />PRE -FABRICATED ROOF CURB (14 GA. MIN.) <br />NAILING STRIP <br />DUCT <br />GALV. MTL COUNTER FLASHING <br />INSULATION <br />4" CANT AND MTL. FLASHING + <br />COUNTER FLASHING AND ROOF <br />PATCH AND REPAIR ALL AROUND <br />INSULATION <br />ROOF INSULATION AND MTL DECK <br />CURB INSTALATION DETAIL <br />NTSC <br />PACKAGED GAS / ELECTRIC HIGH EFFICIENCY AIR CONDITIONING UNITS <br />MARK <br />SERVICE <br />MAKE <br />MODEL <br />S.A. <br />MIN. <br />EXT. <br />FAN <br />HP <br />HEATING <br />COOLING CAPACITY <br />REFRIG. <br />SEER / <br />FLA/MCA <br />ELECTRICAL <br />WEIGHT <br />ACCESSORIES <br />CFM <br />O.A. <br />STATIC <br />RPM <br />FUEL <br />INPUT <br />TOTAL / SENS <br />EAT <br />AMBIENT <br />EER <br />MOCP <br />CFM <br />MBH/STAGES <br />MBH <br />DB / WB <br />DB <br />AC / 1 <br />STOCK <br />LENNOX <br />LGHO60H4E <br />2000 <br />210 <br />1.0 <br />1110 <br />1 <br />GAS <br />65 / 1 <br />57.5 / 47.0 <br />77 j 64 <br />105 <br />R-410A <br />17.0 / <br />14.8 / 18 <br />480 / 3 / 60 <br />1100 LBS <br />1 - 7 <br />12.7 <br />25 <br />AC j 2 <br />OFFICE AREA <br />LENNOX <br />LGH048H4E <br />1600 <br />175 <br />1.0 <br />1195 <br />3/4 <br />GAS <br />65 / 1 <br />45.4 j 37.7 <br />77 / 64 <br />105 <br />R-410A <br />17.0 / <br />11.6 j 14 <br />480 j 3 / 60 <br />1000 LBS <br />1 - 7 <br />12.8 <br />15 <br />AC / 3 <br />SALES <br />LENNOX <br />LGH156H48 <br />5200 <br />1270 <br />1.0 <br />945 <br />5 <br />GAS <br />169 / 1 <br />148.3 / 114.2 <br />80 / 67 <br />105 <br />R-410A <br />-- / <br />30.4 / 35 <br />480 / 3 j 60 <br />2400 LBS <br />1 - 7 <br />12.0 <br />40 <br />AC / 4 <br />FITTING/ <br />LENNOX <br />LGH0361­14E <br />1200 <br />165 <br />1.0 <br />1110 <br />1/2 <br />GAS <br />65 f 1 <br />33.2 j 27.4 <br />78 j 65 <br />105 <br />R-410A <br />17.0 j <br />8.8 / 10 <br />480 j 3 / 60 <br />1000 LBS <br />1 - 7 <br />TOILETS <br />12.5 <br />15 <br />AC / 5 <br />SALES <br />LENNOX <br />LGH156H48 <br />5200 <br />1270 <br />1'0 <br />945 <br />5 <br />GAS <br />169 f 1 <br />148.3 % 114.2 <br />80 / 67 <br />105 <br />R-410A <br />-- / <br />30.4 / 35 <br />480 / 3 / 60 <br />2400 LBS <br />1 - 7 <br />12.0 <br />40 <br />AC / 6 <br />SALES <br />LENNOX <br />LGH156H4B <br />5200 <br />1270 <br />1.0 <br />945 <br />5 <br />GAS <br />169 f 1 <br />148.3 / 114.2 <br />80 / 67 <br />105 <br />R-410A <br />-- / <br />30.4 / 35 <br />480 / 3 / 60 <br />2400 LBS <br />1 - 7 <br />12.0 <br />40 <br />AC / 7 <br />SALES <br />LENNOX <br />LGH180H4B <br />6000 <br />1460 <br />1.0 <br />970 <br />5 <br />GAS <br />169 / 1 <br />176.0 / 167,8 <br />77 f 65 <br />105 <br />R-410A <br />-- / <br />36.8 / 42 <br />480 f 3 f 60 <br />2700 LBS <br />1 - 7 <br />12.0 <br />45 <br />NOTE: ROOFTOP UNITS SHALL BE PURCHASED THROUGH LENNOX NATIONAL ACCOUNT. SUBSTITUTIONS ARE NOT PERMITTED. <br />ACCESSORIES: <br />1. NON -PRORATED WARRANTY OF 5 YEARS FOR THE COMPRESSORS AND 10 YEARS FOR THE HEAT EXCHANGERS, DUAL 115 VOLT GFCI TYPE SERVICE OUTLET (WIRING TO THE OUTLET <br />SHALL BE FIELD PROVIDED BY THE ELECTRICAL CONTRACTOR ON SITE), COMPRESSOR TIME DELAY RELAY, FREEZE STAT, HIGH AND LOW PRESSURE SWITCHES, CRANKCASE HEATER, <br />CONDENSER COIL GUARD, COIL DEFROST THERMOSTAT, 2" PLEATED FILTERS AND SPARE SET. <br />2. CONTROLLED FROM FACTORY INSTALLED AND TESTED PRODIGY M2 WITH BACNET CONTROL MODULE. <br />3. FACTORY INSTALLED PHOTO ELECTRIC SMOKE DETECTOR IN SUPPLY AND RETURN AIR SECTIONS OF UNIT WITH REMOTE MOUNTED STATUS AND TEST STATIONS INTERLOCKED TO STOP FAN ON <br />ACTIVATION. REFER TO DETAIL ON THIS SHEET. <br />4• PROVIDE WITH 14" INSULATED ROOF CURB WITH FACTORY INSTALLED BURGLAR BARS. <br />5. MECHANICAL CONTRACTOR TO PROVIDE 12" HIGH REFLECTIVE UNIT NUMBERS WITH SPECIFIC A/C UNIT NUMBER TO BE POSTED ON EACH UNIT ON THE CONTROL PANEL DOOR AND SIDE WITH <br />DISCONNECT IN A LOCATION VISIBLE FROM THE ROOF HATCH. <br />6. FACTORY INSTALLED GEAR DRIVEN ECONOMIZER WITH GLOBAL ENTHAL.PY CONTROLS AND OUTDOOR AIR HOOD. TWO CLEANABLE ALUMINUM MESH OUTDOOR AIR FILTERS TO BE FURNISHED <br />BY LENNOX WITH ECONOMIZER. PROVIDE WITH POWER EXHAUST FANS (BAROMETRIC RELIEF DAMPER FOR 5 TON UNITS AND BELOW). <br />7. HACR CIRCUIT BREAKERS TO BE FACTORY INSTALLED AND FACTORY WIRED BY LENNOX ON ALL UNITS ABOVE 12.5 TONS. UNITS 12.5 TONS AND BELOW SHALL BE SUPPLIED WITH <br />NON -FUSED SERVICE DISCONNECT FACTORY INSTALLED AND FACTORY MIRED. <br />NOTES: <br />1. PER FBC 2010 ENERGY CONSERVATION SECTION 503.2.5.4 (SHUTOFF DAMPER CONTROLS) <br />PROVIDE MOTORIZED DAMPERS FOR O/A INTAKE FOR AHU. CONNECT MOTORIZED DAMPER TO TIME CLOCK TO CLOSE <br />OUTSIDE AIR INTAKE AUTOMATICALLY WHEN THE SPACE SERVED IS NOT IN USE (OFF BUSINESS HOURS). <br />Prof. M!ar. <br />JU <br />Job. Capt. <br />SG <br />Drawn by <br />JT <br />RON BARR, A.I.A. <br />Revd by <br />STATE OF FLORIDA <br />I5 <br />AR 0016160 <br />(.3 U) F- } <br />Q <br />U W <br />F F <br />H O W F W It W <br />U 0� W ?i 8 O m <br />0 O m <br />W O <br />¢ p O� 0 0 O O F", <br />a~ <br />Z U o O <br />O <br />Q U LL <br />_j 0 EE <br />a Q 2 0 V- W <br />m <br />m <br />W F- F z w Q n 9 3 <br />z <br />z <br />2 W 6� o 2= z> O <br />O <br />O W W <br />cn m <br />>- O f a} z O WO F- <br />m w O z Z U <br />LL p0 z <br />z a 0 <br />o f a W z a. F- 0 <br />LLJ <br />¢ w <br />w p O N Z p <br />CLMp <br />coF <br />n. w W0� w Y w <br />R <br />fr <br />a <br />s _W <br />a W,z o z'W, E a z F <br />�Of <br />w <br />�F ;XWZ"-Xa= <br />0 <br />W F o <br />W° � M°°- W. <br />�¢ <br />D z O� F- U) <br />a O <br />(L U <br />OM0J <br />z W Z <br />O <br />0 0 T H <br />O z <br />O r W z 2 Z z 0 W <br />0 2 a 2 z 0 <br />U= <br />2. z d Of <br />W F <br />U LL 0 W W O m a U <br />F a 0 a <br />H a O D U R F z K 2 a <br />© <br />COPYRIGHT 2012 <br />BARR ARCHITECTURAL STUDIO <br />Revisions: <br />CADFILE No. <br />C7 <br />,� <br />a <br />M <br />a <br />M <br />tAu <br />v' <br />� <br />.j <br />�Faw <br />ago <br />tA�"WeEft- <br />IL <br />tA <br />iu3vodN. <br />a <br />3 <br />O <br />N <br />Fy <br />L <br />O <br />_ N <br />M (4 c <br />cCi <br />m N cn <br />o N c <br />Ll N � <br />C. <br />> 'I <br />L N <br />~ 0 <br />c <br />to <br />E <br />0 <br />O m i <br />4- <br />- <br />00 <br />r O <br />U <br />N <br />0 U <br />� N <br />CD <br />U 2 <br />L <br />cu <br />Sheer. Title <br />MECHANICAL <br />NOTES & DETAILS <br />Sca Is; <br />BUCHANAN P.E. CONSULTING <br />ELECTRICAL * MECHANICAL * PLUMBING <br />ENGINEERING <br />6191 W. ATLANTIC BLVD., SUITE #2 <br />MARGATE, FL 33063 <br />Ph:954-590-3300 Fax:954-590-2232 <br />Email mepengineers@aol.com <br />RAJA BUCHANAN FL P.E # 48916 <br />CERTIFICATE OF AUTHORIZATION # 8842 <br />Date: <br />SEAL 01-31-2013 <br />JA UCHANAN <br />Project No. <br />12-027 <br />DATE: 2dilt <br />M;,•n <br />m2-0 <br />2 OF 2 <br />FILE: 1612-M1-O.DWG <br />