H.u.A.C. GENERAL MOTES: <br />ALL WORK SHALL BE DONE IN ACCORDANCE WITH FBC-2010, 2006 NFPA-101, 2006 NFPA-1, 2008 NFPA-70. <br />1.ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL <br />BE FULLY OPERATIVE AND ACCEPTANCE BY THE OWNER AND/OR ARCHITECT MUST BE CONDITION OF THE CONTRACT. SUBMIT SHOP DRAWINGS <br />ON ALL EQUIPMENT, FOR REVIEW PRIOR TO PURCHASING. <br />2. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES IN ORDER TO AVOID CONFLICTS. NO CHARGES WILL BE ACCEPTED <br />UNLESS A PRIOR WRITTEN APPROVAL HAS BEEN ISSUED BY THE OWNER/ARCHITECT. <br />3. THE CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE WITH EXISTING CONDITIONS. PRIOR TO INSTALLING EQUIPMENT <br />AND/OR FABRICATING DUCTWORK, AC. CONTRACTOR SHALL CHECK THAT THERE IS SUFFICIENT CLEARANCES FOR EQUIPMENT, DUCTWORK, ETC. <br />AND ALSO TO AVOID ANY INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. <br />4. DRAWINGS ARE DIAGRAMMATIC ILLUSTRATIONS. DO NOT SCALE DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT. PIPING, DUCTWORK, <br />ETC. THESE DRAWINGS ARE NOT INTENDED TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR SHALL FURNISH AND <br />INSTALL ALL ITEMS REQUIRED FOR A COMPLETE ACCEPTABLE WORKING SYSTEM. <br />5. CONTRACTOR WILL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTS. <br />6. INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST ASHRAE GUIDE. ALL MATERIALS <br />SHALL BE NEW AND SHALL BEAR UNDERWRITER'S LABEL WHERE APPLICABLE. <br />7. AIR FILTERS SHALL BE INSTALLED ON ALL RETURN AIR EQUIPMENT INLETS. PROVIDE AN EXTRA FILTER, INSTALL AT END OF <br />CONSTRUCTION. <br />8. ALL REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE <br />FOR THE DURATION OD THE WORK. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE NATIONAL, <br />STATE, AND LOCAL CODES, RULES, AND ORDINANCES. <br />9. PROVIDE MAIN CONDENSATE DRAIN AND AUXILUARY DRAIN PAN (AUXILIARY DRAIN PAN SHALL BE EQUIPPED WITH A WATER -LEVEL <br />DETECTION DEVICE THAT WILL SHUT OFF THE EQUIPMENT SERVED PRIOR TO OVERFLOW OF THE PAN AS PER FMC 2010 SECTION 307.2.3) <br />FOR ALL AIR CONDITIONING UNITS AND DRAIN TO EXTERIOR PERMEABLE SOIL OR AS SHOWN ON THE PLANS. <br />10. AIR CONDITIONING CONDENSATE PIPING AND FITTINGS SHALL BE PVC OR DWV ( ASTM-D2662). COPPER IN PLENUM AREAS, ALL INTERIOR <br />CONDENSATE PIPING IN UNCONDITIONED SPACES SHALL BE WRAPPED WITH A MINIMUM 1/2" SELF SEALING INSULATING FOAM JACKET. THE <br />CONTRACTOR SHALL PROVIDE ALL NECESSARY CONTROLS FOR THE OPERATION OF THE HVAC SYSTEM. <br />11. NA <br />12. THERMOSTAT MUST BE PROGRAW iABtt TO BE ABLE TO SET THE TEMPERATURE BACK (OR OFF) WHEN SPACE IS UNOCCURED OR AT <br />OTHER TIMES AS NEEDED BY USER. <br />13. ALL MATERIAL EXPOSED WITHIN PLENUM MUST BE NON COMBUSTIBLE OR RATED 25/50 FLAME SPREAD. <br />14. NA <br />15. ALL VENTILATION DUCTWORK SHALL BE GALVANIZED SHEET METAL <br />16. NA <br />17. HANGERS SHALL BE PROVIDED IN ACCORDANCE WITH S.M.A.C.N.A. RECOMMENDATIONS. <br />18. AIR DISTRIBUTION ACCESSORIES SHALL BE AIR GUIDE, ANEMOSTAT, TINS, OR APPROVED EQUAL ALL SUPPLY A.C. DUCT ELBOWS MUST <br />BE FURNISHED WITH APPROVED TURNING VANES. BRANCH TAKEOFFS MUST BE PROPORTIONAL SPLITS. <br />19. THE OWNER SHALL APPROVE THE FINISH COLOR OF ALL EXPOSED AIR DISTRIBUTION DEVICES. <br />20. PROVIDE FIRE DAMPERS IN ALL DUCTS PASSING THROUGH FIRE DIVISION ASSEMBLIES. FIRE DAMPERS MUST HAVE FIRE RATING EQUAL TO <br />OR GREATER THAN THE PENETRATED ASSEMBLY RATING. FIRE DAMPER INSTALLATIONS SHALL COMPLY WITH ALL LOCAL CODES. PROVIDE <br />ACCESS PANEL TO ALL FIRE DAMPERS. <br />21. ELECTRIC STRIP HEATERS SHALL BE BLAST COIL TYPE WITH NICKEL CHROMIUM WIRE AND INSULATING BUSHINGS FACTORY MOUNTED AND <br />WIRED INCLUDING ALL HEAT LIMITERS, HOGH LIMIT SWITCHES, AND CONTRACTORS IN ACCORDANCE WITH THE "NATIONAL ELECTRIC CODE". <br />22. EXHAUST FANS SHALL HAVE THE CAPACITIES AS STATED ON THE DRAWINGS AND BE PROVIDED WITH BACK DRAFT DAMPER, BIRD SCREEN. <br />23. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD NOT LESS THAN 1 YEAR <br />FROM THE DATE OF ACCEPTANCE, UNLESS OTHERWISE NOTED. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL <br />CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIRS OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED OR <br />IS NOT OPERATING PROPERLY. <br />24. ARCHITECTURAL AND/OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO REVISIONS FOR SUBSTITUTIONS BY THE CONTRACTOR <br />SHALL BE PAID FOR BY THE CONTRACTOR. <br />25. AIR DISTRIBUTION SYSTEM TESTING, ADJUSTING AND BALANCING. A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER OR <br />THE DESIGNATED REPRESENTATIVE OF THE BUILDING OWNER FOR HVAC SYSTEMS SERVING ZONES WITH A TOTAL CONDITIONED AREA <br />EXCEEDING 5000 SQUARE FEET. AIR DISTRIBUTION SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY AN ENGINEER LICENSED IN <br />THIS STATE OR A COMPANY OR INDIVIDUAL HOLDING A CURRENT CERTIFICATION FROM A RECOGNIZED TESTING AND BALANCING AGENCY <br />ORGANIZA11ON IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING STANDARDS. <br />EXCEPTIONS: <br />1. BUILDINGS WITH COOLING OR HEATING SYSTEM CAPACITIES OF 15 TONS OR LESS PER SYSTEM MAY BE TESTED AND BALANCED BY A <br />MECHANICAL CONTRACTOR LICENSED TO DESIGN AND INSTALL SUCH SYSTEM(S). <br />2. BUILDINGS WITH COOLING OR HEATING SYSTEM CAPACITIES OF 65,000 BTU/H OR LESS PER SYSTEM ARE EXEMPT FROM THE <br />REQUIREMENTS OF THIS SECTION. <br />AIR SYSTEM BALANCING SHALL COMPLY WITH FBC 2010 ENERGY CONSERVATION SECTION 503.2.9.1 <br />26. AS PER FBC 2010 ENERGY CONSERVATION SECTION 503.2.9.3, AN OPERATING AND MAINTENANCE MANUAL SHALL BE PROVIDED TO <br />THE BUILDING OWNER BY THE MECHANICAL CONTRACTOR. THE MANUAL SHALL INCLUDE, AT LEAST, THE FOLLOWING: <br />1. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. <br />2. EQUIPMENT OPERATION AND MAINTENANCE MANUALS, <br />3. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL <br />SEQUENCE DESCRIPTIONS. DESIRED OR FIELD -DETERMINED SET POINTS SHALL BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT <br />CONTROL DEVICES OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. <br />4. A COMPLETE WRITTEN NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. <br />27. ALL PIPING SERVING AS PART OF A HEATING OR COOLING SYSTEM SHALL BE THERMALLY INSULATED IN ACCORDANCE WITH FBC <br />2010 ENERGY CONSERVATION TABLE 503.2.8. <br />28. IF THERE ARE ANY CHANGES IN ENGINEER'S DRAWINGS, IN DESIGN OR IN EQUIPMENT, WITHOUT ENGINEER'S CONSENT, THE A.C. <br />CONTRACTOR SHALL ASSUME ALL RESPONSIBILITIES FOR THE PROJECT. <br />29. SMOKE DETECTORS ARE REQUIRED ON ALL PRIMARY AIR CONDITIONING SYSTEMS WHERE TOTAL AIR VOLUME EXCEEDS 2,000 C.F.M. <br />(FBC-MECHANICAL 2010, SEC11ON 606.2.1) A DUCT ACCESS DOOR IS REQUIRED TO ACCESS THE DETECTOR. THE SYSTEM SHALL BE WIRED <br />SO AS WHEN THE DUCT SMOKE DETECTOR DETECTS SMOKE, IT SHALL STOP THE AC SUPPLY FAN AND CAUSE A VISUAL AND AUDIBLE <br />SIGNAL IN A NORMALLY OCCUPIED LOCATION. ALSO, THE DETECTOR SHALL INDICATE A TROUBLE CONDITION EITHER VISUALLY OR AUDIBLY IN <br />THE NORMALLY OCCUPIED LOCATION, AND BE IDENTIFIED AS AIR DUCT DETECTOR TROUBLE. NFPA 90A, 4-4.4.3 <br />(THE TESTER SHOULD BE EQUIPPED WITH AN LED LIGHT TO INDICATE TROUBLE). <br />30. AS PER FBC 2010 ENERGY CONSERVATION SECTION 503.2.5.4 (SHUTOFF DAMPER CONTROLS) <br />PROVIDE MOTORIZED DAMPERS FOR O/A INTAKE FOR AHU. CONNECT MOTORIZED DAMPER TO TIME CLOCK TO CLOSE OUTSIDE AIR INTAKE <br />AUTOMATICALLY WHEN THE SPACE SERVED IS NOT IN USE (OFF BUSINESS HOURS). <br />31. GRAVITY HOODS, VENTS, AND VENTILATORS. ALL OUTDOOR AIR SUPPLY AND EXHAUST HOODS, VENTS, AND VENTILATORS SHALL BE <br />EQUIPPED WITH DAMPERS THAT WILL AUTOMATICALLY SHUT WHEN THE SPACES SERVED ARE NOT IN USE, <br />EXCEPTION: VENTILATION SYSTEMS SERVING UNCONDITIONED SPACES. <br />32. NA <br />33. AS PER FBC-301.4 ALL APPLIANCES REGULATED BY THIS CODE SHALL BE LISTED AND LABELED UNLESS OTHERWISE APPROVED IN <br />ACCORDANCE WITH SEC11ONS 301.4.1 THROUGH 301.4.4. <br />34. AS PER FMC-304.10 GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EQUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE <br />SERVICE AND ROOF HATCH OPENINGS ARE LOCATED WITHIN 10 FT. OF ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE <br />OR OPEN SIDE IS LOCATED MORE THAN 30" ABOVE THE FLOOR, ROOF OR GRADE BELOW. <br />35. AS PER 306.5.1 SLOPED ROOFS. WHERE APPLIANCES, EQUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE INSTALLED <br />ON A ROOF HAVING A SLOPE OF THREE UNITS VERTICAL IN 12 UNITS HORIZONTAL OR GREATER AND HAVING AN EDGE MORE THAN 30" <br />ABOVE GRADE AT SUCH EDGE A LEVEL PLATFORM SHALL BE PROVIDED ON EACH SIDE OF THE APPLIANCE TO WHICH ACCESS IS REQUIRED <br />FOR SERVICE, REPAIR OR MAINTENANCE. THE PLATFORM SHALL BE NOT LESS THAN 30" IN ANY DIMENSION AND SHALL BE PROVIDED WITH <br />GUARDS. THE GUARDS SHALL EXTEND NOT LESS THAN 42"ABOVE THE PATFORM, SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE <br />OF A 21" DIAMETER SPHERE AND SHALL COMPLY WITH THE LOADING REQUIREMENTS FOR QUARDS SPECIFIED IN THE FBC. <br />36. ANY INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 1OFT. FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE. <br />37. ALL COOKING APPLIANCES THAT ARE DESIGNED FOR PERMANENT INSTALLATION SHALL BE LISTED , LABELED AND INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTION. <br />38. ROOF MOUNTED MECHANICAL UNITS SHALL BE MOUNTED ON CURBS RAISED A MINIMUM OF 8 INCHES (203 MM) <br />ABOVE THE ROOF SURFACE, OR WHERE ROOFING MATERIALS EXTEND BENEATH THE UNIT, ON RAISED EQUIPMENT SUPPORTS <br />PROVIDING A MINIMUM CLEARANCE HEIGHT IN ACCORDANCE WITH TABLE 1509.7. <br />TABLE 1509.7 CLEARANCE BELOW RAISED ROOF MOUNTED MECHANICAL UNITS <br />WIDTH OF MECHANICAL UNIT (INCHES) <br />SURFACES (INCHES) <br /><24 /24<36 / 36 < 48 / 48 < 60 / > 60 <br />14" 18" 24" 30" 48" <br />39. ROOF TOP A/C UNIT CURB SHALL BE MINIMUM 14 GAUGE (HURRICANE RATED CURB). <br />40. THE CONTRACTOR SHALL FIELD VERIFY ALL IXISTING CONDITIONS AND INFORM THE PROJECT ENGINEER AND ARCHITECT OF ANY <br />DISCREPANCY BETWEEN THESE PLANS AND THE EXISTING CONDITIONS. THE CONTRACTOR SHALL INCLUDE IN HIS BID TO CORRECT SUCH <br />CONDITION AS DIRECTED. THE ENGINEER AND ARCHITECT ARE NOT RESPONSIBLE FOR ANY ADDITIONAL COSTS RESULTING FROM VERIFIABLE <br />EXISTING CONDITIONS DISCOVERED AFTER CONTRACT HAS BEEN AWARDED. <br />NOTE: <br />PROVIDE FLOAT SWITCH, TO BE INSTALLED <br />IN THE PRIMARY DRAIN PAN OF THE UNIT. <br />4' MAX BETWEEN SUPPORTS - <br />NOTE: <br />ROOF MOUNTED MECHANICAL UNITS <br />SHALL BE MOUNTED ON CURBS <br />RAISED A MINIMUM OF 8 INCHES <br />ABOVE THE ROOF SURFACE <br />4-1/2 X 5/16 SCREW <br />8" O.C. <br />END SCREWS TO BE <br />OUT PLACED WITHIN 6" OF <br />CORNER. <br />MIN. 8" ABOVE FINISHED ROOFING <br />CURB MIN. 14 GA. <br />GALV METAL STRAP W/ NEOPRENE GASKET FASTEN <br />TO PIPE STAND <br />PVC CONDENSTATE SEE MECH. PLANS <br />FOR CONTINUATION <br />RTU TO CURB ATTACHMENT & DRAIN DETAL <br />NTSC <br />G\O$ <br />OPTION 1. <br />CONNECT PREFABRICATED RTU CURB <br />DIRECTLY TO STEEL ANGLES / BAR <br />JOIST W/ MIN. 3/8" DAM. S.S. BOLTS <br />W/ WASHERS THRU FLANGE OF CURB <br />AND STEEL ANGLE / BAR JOIST <br />BELOW AT ALL CORNERS AND BALANCE <br />0 12" O.C. MAX ALL 4 SIDES <br />OPTION 2. <br />WELD CURB TO STEEL ANGLES "FRAM <br />WITH 1/2" BEAD EVERY 6 INCHES. <br />NEW 4 x 4 x 1/4" STEEL <br />ANGLES (6'-0" O.C. MAX) FULLY <br />WELDED TO EX. BAR JOISTS <br />NOTE: <br />CURB MUST BE INSULATED FROM INSIDE. <br />CURB TO ROOF JOIST ATTACHMENT DETAIL <br />NTSC <br />y:I 06` "0 <br />RELIEF VENT SAME SIZE AS CONDENSATE LINE <br />CONC. COVER WITH LIFT HANDLE <br />NATURAL EARTH ICI <br />I Ill- \-PVC CONDENSATE DRAIN <br />LINE SEE PLAN FOR SIZE <br />SEAL WITH SILICONE <br />24"0 x 36" LONG =� <br />GALVANIZED STEEL <br />- �I CAULK (OR EQ.) <br />THE EXCAVATED PIT SHALL <br />BE COMPLETELY FILLED <br />WITH COARSE GRAVEL. <br />$ <br />2"0 CLEAN STONES <br />(STABALIZED) <br />NOTES: <br />1. STABALIZER STONES MIN. ONE HALF CUBIC YARD <br />DRYWELL DETAIL <br />NTSC <br />GASKET, TYP. <br />NAILING <br />DUCT - <br />INSULATION <br />INSULATION <br />CURB INSTALAT'ION DETAIL <br />NTSC <br />RTU, SEE MECH. DWGS. <br />PRE -FABRICATED ROOF CURB (14 GA. MIN.) <br />GALV. MTL COUNTER FLASHING <br />4" CANT AND MTL. FLASHING + <br />COUNTER FLASHING AND ROOF <br />PATCH AND REPAIR ALL AROUND <br />ROOF INSULATION AND MTL DECK <br />=i1 3i� <br />NOTES: <br />1. PER FBC 2010 ENERGY CONSERVATION SECTION 503.2.5.4 (SHUTOFF DAMPER CONTROLS) <br />PACKAGED GAS / ELECTRIC HIGH EFFICIENCY AIR CONDITIONING UNITS <br />MARK <br />SERVICE <br />MAKE <br />MODEL <br />S.A. <br />MIN. <br />EXT. <br />FAN <br />HP <br />HEATING <br />COOLING CAPACITY <br />REFRIG. <br />SEER / <br />FLA/MCA <br />ELECTRICAL <br />WEIGHT <br />ACCESSORIES <br />CFM <br />0. A. <br />STATIC <br />RPM <br />FUEL <br />INPUT <br />TOTAL / SENS <br />EAT <br />AMBIENT <br />EER <br />MOCP <br />CFM <br />MBH/STAGES <br />MBH <br />DB / WB <br />DB <br />AC / 1 <br />STOCK <br />LENNOX <br />LGH060H4E <br />2000 <br />210 <br />1.0 <br />1110 <br />1 <br />GAS <br />65 / 1 <br />57.5 / 47.0 <br />77 / 64 <br />105 <br />R-410A <br />17.0 i <br />14.8 / 18 <br />480 / 3 j 60 <br />1100 LEIS <br />1 - 7 <br />12.7 <br />25 <br />AC / 2 <br />OFFICE AREA <br />LENNOX <br />LGH048H4E <br />1600 <br />175 <br />1.0 <br />1195 <br />3/4 <br />GAS <br />65 / 1 <br />45.4 / 37.7 <br />77 / 64 <br />105 <br />R-410A <br />17.0 / <br />11.6 / 14 <br />480 / 3 / 60 <br />1000 LBS <br />1 - 7 <br />12.8 <br />15 <br />AC j 3 <br />SALES <br />LENNOX <br />LGH156H4B <br />5200 <br />1270 <br />1.0 <br />945 <br />5 <br />GAS <br />169 f 1 <br />148.3 f 114.2 <br />80 / 67 <br />105 <br />R-410A <br />-- / <br />30.4 / 35 <br />480 / 3 / 60 <br />2400 LBS <br />1 - 7 <br />12.0 <br />40 <br />AC f 4 <br />FITTING/ <br />LENNOX <br />LGH036H4E <br />1200 <br />165 <br />1.0 <br />1110 <br />1/2 <br />GAS <br />65 % 1 <br />33.2 / 27.4 <br />78 / 65 <br />105 <br />R-410A <br />17.0 / <br />8.8 / 10 <br />480 / 3 j 60 <br />1000 LBS <br />1 - 7 <br />TOILETS <br />12.5 <br />15 <br />AC / 5 <br />SALES <br />LENNOX <br />LGH156H4B <br />5200 <br />1270 <br />1.0 <br />945 <br />5 <br />GAS <br />169 / 1 <br />148.3 / 114.2 <br />80 / 67 <br />105 <br />R-410A <br />-- / <br />30.4 / 35 <br />480 / 3 / 60 <br />2400 LBS <br />1 - 7 <br />12.0 <br />40 <br />AC / 6 <br />SALES <br />LENNOX <br />LGH156H4B <br />5200 <br />1270 <br />1.0 <br />945 <br />5 <br />GAS <br />169 % 1 <br />148.3 / 114.2 <br />80 / 67 <br />105 <br />R-410A <br />--/ <br />30.4 / 35 <br />480 / 3 / 60 <br />2400 LBS <br />1 - 7 <br />12.0 <br />40 <br />AC / 7 <br />SALES <br />LENNOX <br />LGH180H48 <br />6000 <br />1460 <br />1.0 <br />970 <br />5 <br />GAS <br />169 / 1 <br />176.0 j 167.8 <br />77 / 65 <br />105 <br />R-410A <br />-- / <br />36.8 / 42 <br />480 / 3 / 60 <br />2700 LBS <br />1 - 7 <br />12.0 <br />45 <br />NOTE: ROOFTOP UNITS SHALL BE PURCHASED THROUGH LENNOX NATIONAL ACCOUNT. SUBSTITUTIONS ARE NOT PERMITTED. <br />ACCESSORIES: <br />1. NON -PRORATED WARRANTY OF 5 YEARS FOR THE COMPRESSORS AND 10 YEARS FOR THE HEAT EXCHANGERS, DUAL 115 VOLT GFCI TYPE SERVICE OUTLET (WIRING TO THE OUTLET <br />SHALL BE FIELD PROVIDED BY THE ELECTRICAL CONTRACTOR ON SITE), COMPRESSOR TIME DELAY RELAY, FREEZE STAT, HIGH AND LOW PRESSURE SWITCHES, CRANKCASE HEATER, <br />CONDENSER COIL GUARD, COIL DEFROST THERMOSTAT, 2" PLEATED FILTERS AND SPARE SET. <br />2. CONTROLLED FROM FACTORY INSTALLED AND TESTED PRODIGY M2 WITH BACNET CONTROL MODULE. <br />3. FACTORY INSTALLED PHOTO ELECTRIC SMOKE DETECTOR IN SUPPLY AND RETURN AIR SECTIONS OF UNIT WITH REMOTE MOUNTED STATUS AND TEST STATIONS INTERLOCKED TO STOP FAN ON <br />ACTIVATION. REFER TO DETAIL ON THIS SHEET. <br />4• PROVIDE WITH 14" INSULATED ROOF CURB WITH FACTORY INSTALLED BURGLAR BARS. <br />5. MECHANICAL CONTRACTOR TO PROVIDE 12" HIGH REFLECTIVE UNIT NUMBERS WITH SPECIFIC A/C UNIT NUMBER TO BE POSTED ON EACH UNIT ON THE CONTROL PANEL DOOR AND SIDE WITH <br />DISCONNECT IN A LOCATION VISIBLE FROM THE ROOF HATCH. <br />6. FACTORY INSTALLED GEAR DRIVEN ECONOMIZER WITH GLOBAL ENTHALPY CONTROLS AND OUTDOOR AIR HOOD. TWO CLEANABLE ALUMINUM MESH OUTDOOR AIR FILTERS TO BE FURNISHED <br />BY LENNOX WITH ECONOMIZER. PROVIDE WITH POWER EXHAUST FANS (BAROMETRIC RELIEF DAMPER FOR 5 TON UNITS AND BELOW). <br />7. HACR CIRCUIT BREAKERS TO BE FACTORY INSTALLED AND FACTORY WIRED BY LENNOX ON ALL UNITS ABOVE 12.5 TONS. UNITS 12.5 TONS AND BELOW SHALL BE SUPPLIED WITH <br />NON -FUSED SERVICE DISCONNECT FACTORY INSTALLED AND FACTORY MRED. <br />PROVIDE MOTORIZED DAMPERS FOR O/A INTAKE FOR AHU. CONNECT MOTORIZED DAMPER TO TIME CLOCK TO CLOSE <br />OUTSIDE AIR INTAKE AUTOMATICALLY WHEN THE SPACE SERVED IS NOT IN USE (OFF BUSINESS HOURS). <br />Pro,j. Mgr. <br />JU <br />Job. Capt. <br />SG <br />Drawn bS <br />JT <br />RON <br />BARR, A.I.A. <br />Rev'cl by <br />STATE OF FLORIDA <br />AR 0016160 <br />U m ~ <br />> m <br />U <br />H <br />W <br />h W <br />hW- O W <br />_ H <br />Q H W W <br />W 0 O m <br />wO <br />m <br />U o <br />Q Zp 0 <br />w O <br />F- p O U 0 Fz u) <br />Z <br />WO <br />tr U 0 <br />J <br />H H to W_ O <br />w <br />W <br />a <br />O W <br />m 2 <br />w~ <br />0 U m <br />O z w O �i <br />� <br />m <br />o <br />Z <br />O2 w 6 <br />a <br />OU 2 w z> z <br />O ir <br />z <br />w w <br />>_U F <br />W U <br />Q O <br />a >- Z H F <br />Z <br />O <br />In to <br />m <br />z z a r 2 U <br />} <br />m UO <br />M 0 0 <br />0O O Z O= <br />�O UO <br />LU a <br />= 07 <br />O vai _°z oU <br />OLd <br />Ww <br />z= U m y W <br />dO <br />WF- <br />a w <br />Cl' z F=- <br />~ <br />W <br />w O <br />- <br />wO <br />(AZ <br />w a <br />0>.0== <br />w <br />FU <br />H� <br />z <br />a F <br />- <br />0 <br />W Z W 0 O Z W <br />U <br />OO <br />a= <br />O50Fag <br />O,wZ' <br />0 Ww a <br />U� <br />O W <br />Z <br />O <br />Z <br />wz 0Uw <br />U <br />Waz V <br />OIx w w o m <br />H <br />a 0 a <br />P Q O <br />a o W P Z�� a <br />@ <br />COPYRIGHT 2012 <br />BARR ARCHITECTURAL STUDIO <br />Revisions: <br />CADFILE No. <br />C7 <br />,� <br />� <br />M <br />tA <br />tA <br />lu <br />JtA <br />IL <br />d <br />tA <br />C7 <br />N <br />z <br />� <br />a <br />O <br />N <br />1w <br />sheet Title <br />mom i <br />O <br />NT <br />co (0 c <br />CO <br />cu N tM <br />o N c <br />r C <br />N <br />> <br />L N <br />~ 0 <br />O <br />CD <br />cu <br />� N <br />U) <br />lL <br />O <br />O W L <br />f-+ <br />-car O <br />U <br />U)Lf) . <br />0 U <br />� N <br />LO Q. U <br />L <br />MECHANICAL <br />NOTES & DETAILS <br />Sca le: <br />BUCHANAN P.E. CONSULTING IN <br />ELECTRICAL * MECHANICAL * PLUMBING <br />ENGINE ERIN G <br />6191 W. ATLANTIC BLVD., SUITE #2 <br />MARGATE, FL 33063 <br />Ph: 954-590-3300 Fax: 954-590-2232 <br />Email: mepengineers@aol.com <br />RAJA BUCHANAN FL P.E # 48916 <br />CERTIFICATE OF AUTHORIZATION # 8842 <br />SEAL <br />A r__ <br />MAY 0 5 2014 <br />DATE: <br />Date: <br />01-31-2013 <br />Project No. <br />12-027 <br />Sheet No, <br />m2-0 <br />2 OF 2 <br />FILE: 1612-M1-O.DWG <br />