- --- - I I I I I_ _��--•�_��-_ 1 �. ° �9R' '�mldn+., � . I�.., 6, PI I Ir • y,.•':I <br />GENERAL PLUMBING NOTE <br />PLUMBING FIXTURES SHALL COMPLY WITH (F.B.C. 2010 PLUMBING TABLE 604.4) <br />NO HOT WATER WITH A TEMPERATURE HIGHER THAN 140' TO DISCHARGE INTO SANITARY. <br />DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. REFER TO ARCHITECTURAL <br />THE DEVELOPED LENGTH OF HOT WATER PIPING FROM THE SOURCE OF HOT WATER <br />PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL PLUMBING FIXTURES, EQUIPMENT, <br />SUPPLY TO THE FARTHEST FIXTURE SHALL BE LESS THAN 100 Fr. <br />ETC. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED <br />FOR A COMPLETE AND ACCEPTABLE WORKING INSTALLATION. <br />RESTROOMS SHALL COMPLY WWITHF.B.C. 2010 BUILDING SECTION 13-412.1 JaBC.2.5.2) <br />ALL WORK AND MATERIALS SHALL COMPLY WITH LATEST EDITIONS OF THE NATIONAL, <br />THE HOT WATER SUPPLY TO ANY FIXTURE REQUIRING HOT WATER SHALL BE INSTALLED <br />STATE, AND ALL LOCAL CODES AND ORDINANCES HAVING JURISDICTION. <br />ON THE LEFT SIDE OF THE FIXTURE. (F.B.C. 2010 PLUMBING 607.4) <br />THE PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE <br />ALL INDIRECT WASTE PIPING SHALL DISCHARGE THROUGH AN AIR GAP OR AIR BREAK <br />THEMSELVES WITH ALL EXISTING CONDITIONS. ALL EXCAVATION AND BACKFILL AS <br />INTO A WASTE RECEPTOR OR STANDPIPE. WASTE RECEPTORS AND STANDPIPES SHALL <br />REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL. BE PART OF THIS CONTRACT. <br />BE TRAPPED AND VENTED AND SHALL CONNECT TO THE BUILDING DRAINAGE SYSTEM. <br />ALL INDIRECT WASTE PIPING THAT EXCEEDS 2 FT IN DEVELOPED LENGTH MEASURED <br />ALL MATERIALS SHALL BE NEW AND FREE OF NOTICEABLE DEFECTS. <br />HORIZONTALLY, OR 4 FT IN TOTAL DEVELOPED LENGTH, SHALL BE TRAPPED. (F.B.C. <br />2010 PLUMBING 802.2) <br />ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR AND IN A <br />FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY <br />ALL DEVICES INTENDED TO SERVE SOME SPECIAL FUNCTION AND THAT CONNECT TO THE <br />OPERATIVE AND ACCEPTED BY THE ENGINEER/ARCHITECT AS SUCH. <br />WATER SUPPLY SYSTEM SHALL BE PROVIDED WITH PROTEC11ON AGAINST BACKFLOW AND <br />CONTAMINATION OF THE WATER SUPPLY SYSTEM. (F.B.C. 2010 PLUMBING 608.3) <br />ALL WORK SHALL: BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH <br />THE PROGRESS OF CONSTRUCTION. <br />NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE PURGED OF DELETERIOUS <br />VERIFY LOCATION, SIZE AND INVERTS OF ALL EXISTING UTILITIES PRIOR TO THE START <br />MATTER AND, DISINFECTED PRIOR TO UTILIZATION. (F.B.C. 2010 PLUMBING 610.1) <br />OF CONSTRUCTION. IMMEDIATELY ADVISE THE ENGINEER/ARCHITECT OF ANY <br />HOT WATER AND DRAIN PIPES UNDER SINKS AND/OR LAVATORIES SHALL BE INSULATED <br />DISCREPANCIES. ALL EXISTING PLUMBING SHOWN ON THE PLANS IS ESTIMATED AND MAY <br />NOT BE IN THE SAME LOCATION AS SHOWN, CONTRACTOR MUST VERIFY EXISTING <br />OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO <br />PLUMBING PRIOR TO COMMENCING WORK. <br />SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. F.B.C. 2010 BUILDING 11-4.19.4 <br />PROVIDE A MINIMUM PITCH OF 1/8" FOR 3" OR LARGER PIPES, 1/4" PITCH FOR LESS <br />& 11-4.24.6) <br />THAN 3" PIPES. <br />PROVIDE A CLEANOUT AT THE BASE OF EACH SOIL AND WASTE STACK. <br />A WATER HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK - CLOSING VALVES <br />ARE UTILIZED, UNLESS OTHERWISE APPROVED. THE ARRESTOR SHALL BE LOCATED <br />PROVIDE MEANS OF RESEALING ALL FLOOR DRAINS. <br />WITHIN AN EFFECTIVE RANGE OF THE QUICK - CLOSING VALVE. ACCESS SHALL BE <br />PROVIDED TO WATER HAMMER ARRESTORS. <br />AN OPEN VENT TERMINAL FROM A DRAIGAGE SYSTEM SHALL NOT BE LOCATED DIRECTLY <br />BENEATH ANY DOOR, OPENABLE WINDOW, OR OTHER AIR INTAKE OPENING OF THE <br />SHUTOFF VALVE SHALL BE INSTALLED ON THE WATER SUPPLY PIPE TO EACH APPLIANCE <br />BUILDING OR OF AN ADJACENT BUILDING, AND ANY SUCH VENT TERMINAL SHALL NOT <br />OR MECHANICAL EQUIPMENT AS PER (F.B.C. 2010 PLUMBING 606.2.3) <br />BE WITHIN 10 FEET HORIZONTALLY OF SUCH AN OPENING UNLESS IT IS AT LEAST 2 <br />FEET ABOVE THE TOP OF SUCH OPENING. (F.B.C. 2010 PLUMBING 904.5) <br />PROVIDE 1/2"COLD WATER TRAP PRIMER FOR ALL DRAINS FROM THE NEAREST <br />PLUMBING FIXTURE, WHERE APPLICABLE. <br />LANDLORD WORK SUBJECT TO CONFIRMATION: THIS SCOPE OF <br />WORK IS FURNISHED ONLY AS A GUIDE TO THE CONTENTS OF <br />THIS DRAWING AND COMMUNICATION. IT MAY BE INCOMPLETE <br />AND NOT IN FULL CONFORMANCE WITH THE BINDING <br />RESPONSIBILITIES AND SCOPE CALLED OUT OR CONTEMPLATED <br />TO BE IN THE LEASE. PRIOR TO INMATING ROSS <br />CONSTRUCTION CONTRACT DRAWINGS FOR THIS PROJECT YOU <br />MUST VERIFY THE FINAL SCOPES OF WORK THROUGH BEN <br />WHEELER, THE ASSIGNED ROSS CONSTRUCTION REPRESENTATIVE. <br />IN THIS TENANT PLAN THE LANDLORD IS SHOWN TO BE <br />RESPONSIBLE FOR: PROVIDING AN ENTIRELY PROTOTYPE ROSS <br />SHELL AND ELEVATION AS PER THIS ISSUED AE1-0. LANDLORD <br />MUST ALSO ADDRESS ALL GRADING ISSUES AT ALL ELEVATIONS <br />OF THE STORE. IN PARTICULAR THE FRONT ELEVATION CURB <br />LINE IS TO BE MODIFIED AS SHOWN AND EXTERIOR GRADING <br />MUST COINCIDE AND FACILITATE THE ROSS FRONT ELEVATION. <br />LANDLORD IS ALSO SHOWN TO BE RESPONSIBLE FOR; <br />PHYSICALLY DEMISING THE PREMISE WITH A WALL THAT MEETS <br />ROSS PROTOTYPE REQUIREMENTS; PROVIDING A DEDICATED <br />COMPACTOR AND TRUCK DOCK AREA EXCLUSIVE TO ROSS; <br />PROVIDING A DEDICATED 2" WATER LINE, A 1 %' GAS LINE, AND <br />A SANITARY SEWER LINE; AND PROVIDING A PROTOTYPICAL <br />DEDICATED 600 AMP, 277/480 VOLT, 3 PHASE SERVICE.. <br />NEW 4" <br />STUBBED <br />FOR F <br />NOTE: <br />ALL UTILITIES THAT RUN THROUGH THE STORE, INCLUDING <br />SANITARY SEWER AND WATER LINES, SHALL EXCLUSIVELY <br />SERVE THE STORE. LANDLORD SHALL REMOVE ANY UTILITY <br />LINES THAT RUN THROUGH THE STORE WHICH SERVE <br />OTHER TENANTS. <br />INSTALL ALL UTILITIES IN STORE AS SET FORTH IN TENANT'S <br />PROTOTYPE PLANS AND DESIGN GUIDELINES INCLUDING SANITARY <br />SEWER (4" LINE), WATER (2" LINE) AND SEPARATE METERS. <br />MIN. SLOPE <br />(INCH PER FOOT) <br />2 1/2 OR LESS <br />1/4 <br />3 TO 6 <br />1/8 <br />8 OR LARGER <br />1/16 <br />N❑TEI HANGER SPACING SHALL CONFORM TO TABLE 308.5 <F.B.C. 2010 PLUMBING) <br />HANGER LOCKING NUT <br />SUPPORT NUT ROD —'' SUPPORT NUT <br />HEAVY DUTY CLEVIS —HEAVY DUTY CLEVIS <br />HANGER HANGER <br />PIPE VAPOR BARRIER <br />INSULATION <br />.... 16 GAUGE ZINC COATED <br />SHEET STEEL SADDLE AT <br />CLEVIS HANGER LEAST 8" LONG <br />SINGLE HORIZONTAL RUNS <br />NO VAPOR BARRIER INSULATI❑N CLEVIS HANGER <br />SINGLE HORIZONTAL RUNS <br />WITH VAPOR BARRIER INSULATI❑N <br />WELDS WEB MEMBERS ONE ANGLE ON EACH <br />HANGER NUT SIDE OF WEB MEMBERS <br />REST ON TOP OF <br />2" BOTTOM CHORDS STEEL <br />BENT STRAP 1-1/2" JOISTS BETWEEN PANEL <br />3/16" OVER VERT. POINTS, SIZE FOR LOAD` <br />LESS OF ANGLES <br />BOTTOM CHORDS <br />OF STEEL JOIST STEEL J❑IST <br />HEAVY DUTY CONCRETE <br />STEEL INSERT WITH <br />ELONGATED STRAP <br />00 <br />°°g s o BEAM <br />o '$ <br />01 ° °aa JA <br />_ <br />r <br />- - EAM CLAMP <br />INSERT NUT HANGER ROD <br />CONCRETE INSERT - <br />STEEL BEAM = CHANGER ROD. <br />SIZE AS REG. <br />PIPE SUPPORT DETAIL <br />(FOR SANITARY & WATER PIPING) NTS <br />NEW 2" CW LINE <br />STUBBED & CAPPED <br />ABOVE CEILING <<, 2" <br />CONNECT TO THE EXISTING FOR FUTURE USE '*;,.CW <br />SANITARY LINE, CONTRACTOR f �uNE <br />TO VERIFY EXACT SIZE / 1 <br />AND LOCATION 0 SITE. SHUT-OFF <br />VALVE 2" <br />CW <br />I <br />i TO EXISTING 8" CW <br />SERVICE LINE, <br />i <br />SEE CIVIL PLANS <br />< FOR EXACT LOCATION <br />NEW 1-1/2 <br />2" \ WATER <br />CYy �NF - `. METER <br />NEW 1-1/2" NOTE: <br />BACKFLOW VERIFY EXACT LOCATION FOR <br />PREVENTER BACKFLOW PREVENTER AND <br />WATER METER 0 SITE. <br />(SEE CIVIL PLANS) <br />PLUMBING RISERS <br />TEST COCK (TYPICAL) SHUT-OFF VALVE <br />STRAINER — <br />TRAINER (TYPICAL) <br />CW SUPPLY <br />TO BUILDING <br />SUPPORT AS <br />REDUCED PRESSURE REQUIRED <br />BACKFLOW PREVENTER <br />DOUBLE CHECK VALVE <br />-WAITS' SERIES #909 <br />GRADE — _ — <br />I I I�I I I TIT I� <br />CW SUPPLY LINE <br />NOTES: <br />1. VERIFY LOCATIONS OF EXISTING WATER AND SANITARY SUPPLY CONNECTION POINTS WITH CITY OR LOCATE ON EXISTING SITE. <br />2. VERIFY EXISTING SIZES AND INVERTS OF EXISTING UTILITIES PRIOR TO INSTALLATION OF NEW WATER AND SANITARY LINES. <br />3. ALL INTERIOR POTABLE WATER SERVICE PIPING TO BE COPPER TYPE K OR L. ANY SUBSTITUTIONS MUST BE APPROVED BY ENGINEER. <br />4. ALL HOSE BIBBS TO HAVE SHUT OFF VALVES AND VACUUM BREAKERS. <br />5. MAIN WATER SERVICE TO BE SIZED PER PLANS. <br />BACK FLOW PREVENTER <br />NTS <br />PROVIDE EXTRA HEAVY PATTERN FULL OPENING <br />IRON BODY TRAP SCREW FERRULE & ALL BRASS FINISH GRADE <br />CLEANOUT WITH COUNTERSUNK HEAD <br />FINISH GRADE PROVIDE POUREDCONC. MINIMUM 1" <br />BLOCK WHEN C.O. IS <br />NOT IN PAVED AREA <br />'0140' oft 010 0 0 0 0 0 0 0 - - <br />'o C O o .a O ,o . O ,o O •o o O, a` O . o• O o, <br />°,Oe oQof'pooui, <br />OaotOaa4aOao,' Oy°,cpseo0asooQ,;u <br />oo, ,opapoapo,ap,o, <br />31 <br />4,<°o <br />12"A 2"x8" LONG SWEEP. USE SHORT <br />w n' <br />f <br />POURED CONC. SWEEP WHERE REQUIRES —SAME SIZE AS <br />BLOCK WHEN SEWER - MAX. f �— STAINLESS STEEL COVER <br />CLEANOUT IS COMBINA11ON "Y" & SIZE 4" SCREWED TO THREADED <br />NOT IN 1/8" BEND C.O. PLUG <br />PAVED AREA <br />- --"- FACE OF WALL <br />EXTERIOR INTERIOR <br />ELEVATION ELEVATION WALL — TYPE <br />TYPICAL_ CLEANOUT DETAILS <br />GAS VALVES TO BE <br />READILY ACCESSIBLE <br />GAS CONTRACTOR TO VERIFY ALL THE <br />EQUIPMENT SPECIFICATIONS PRIOR TO <br />INSTALLATION AND TO NOTIFY <br />ENGINEER WITH ANY DISCREPANCIES <br />NEW 2" GAS LINE <br />(� STUBBED & CAPPED <br />ABOVE CEILING <br />FOR FUTURE USE <br />I <br />2" <br />GAS I NEW GAS METER <br />LINE I SET 0 2 PSI, TO <br />BE INSTALLED BY <br />GAS COMPANY <br />V <br />SHUT-OFF <br />VALVE <br />GAS NOTES & CALCULATIONS <br />EXPOSED GAS PIPING SHALL BE IDENTIFIED BY A YELLOW <br />LABEL MARKED "GAS" IN BLACK LETTERS. THE MARKING <br />SHALL BE SPACED AT INTERVALS NOT EXCEEDING 5 <br />FEET. *NOT REQUIRED ON STEEL PIPE OR PIPE LOCATED <br />IN SAME ROOM AS EQUIPMENT SERVED. <br />GAS PIPING TO BE INSTALLED BY LICENSED CONTRACTOR <br />TOTAL DEVELOPED GAS PIPE LENGTH <br />FROM REGULATOR TO <br />FURTHEST APPLIANCE = 300' <br />TOTAL BTUH LOAD = 1070,000 BTUH. <br />REQUIRES A 2" GAS LINE PER <br />TABLE 402.4(3) - NATURAL (F.B.C. 2010 FUEL GAS) <br />SCHEDULE 40 METALLIC PIPE <br />INLET PRESSURE: 2.0 P.S.I. <br />PRESSURE DROP: 1.0 P.S.I. <br />SPECIFIC GRAVITY: 0.60 <br />NTS <br />Proj. Mgr, <br />JU <br />Job. Capt. <br />SG <br />Drawn bS <br />JT <br />RON BARR, A.I.A. <br />Revd by STATE OF FLORIDA <br />I<a AR 0016160 <br />Ow E O `w ¢ e w u, <br />w D O m <br />O m ¢ p O- 0 0 <br />of M > o zo <br />goo <br />z 2. w¢a¢3W 0w> z <br />O w 0Ow 1= a >z H Ow0 Wwmm m <br />- HU z z¢¢ fw- Z 0 U <br />O <br />o=Z° C� OOm Iz x ai <br />w¢ om w 2 6 O 6 2 8 a � w <br />U <. Z <br />a. !xn a w [L = U a w Y w <br />a z ¢ u~i oLL z x n1. z~ <br />d' U Fx- U w N Z~ W¢ 2 <br />w o <br />w=o w° °}°°° <br />OO�n z3= <br />0 Q d V D z Zp F Z j z ? J <br />a U w <br />o Z a_ Dowu 0 o= 0 W a= z of Z o <br />�¢ w a � a o 0 0� rw- z?� a <br />© COPYRIGHT 2012 <br />BARR ARCHITECTURAL STUDIO <br />�..�: <br />71, <br />0 � <br />'F <br />X� .y,.,. <br />'✓ , <br />'y <br />4 <br />'40 <br />Ella <br />Revisions: <br />COORDINATION 09-04-13 <br />CADFILE No. <br />4-1 <br />O <br />r. <br />��2 <br />� � <br />� <br />0 <br />Lr) <br />- - <br />_ <br />cu <br />Sheet Title <br />PLUMBING RISER <br />NOTES & DETAILS <br />Sca le: <br />RE CONSULTING INC, SEAL <br />Date: <br />01-31 _2013 <br />Sheet No. <br />ELECTRICAL * MECHANICAL * PLUMBING RAJA BUCHANAN <br />FL RE # 8916 ,_ <br />E NGIN EERIN G <br />Project No. <br />6191 W. ATLANTIC BLVD., SUITE #2 <br />P2-0 <br />MARGATE, FL 33063 <br />Ph: 954-590-3300 Fax: 954-590-2232 <br />q <br />! 2-027 <br />Email: mepengineers@aol.com ' U N 0 5 20114 <br />RAJA BUCHANAN FL P.E # 48916 , <br />CERTIFICATE OF AUTHORIZATION # 8842 DATE:-_w_--� <br />2 OF 2 <br />FILE: 1612-P2-O.DWG <br />f.+ <br />