A2 > GENERAL NOTES <br />THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOBSITE PRIOR TO <br />STARTING ANY WORK AND NOTIFY ENGINEER/ARCHITECT IN WRITING IMMEDIATELY FOR ANY <br />DISCREPANCIES OR THE BUILDER SHALL ACCEPT FULL RESPONSIBILITY FOR ANY ERRORS OR <br />OMISSIONS. <br />DO NOT SCALE THE DRAWINGS. <br />THE GENERAL CONTRACTORSHALL BE RESPONSIBLE FOR THE MEANS AND METHODS OF <br />CONSTRUCTION AND TO PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE AND THE <br />PEOPLE AT WORK OR OTHERS DURING THE CONSTRUCTION. <br />THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO SUPERVISE AND COORDINATE ALL THE WORK <br />OF ALL TRADES <br />THE GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF CHASES, OPENINGS, INSERTS, SLEEVES, <br />PADS, DEPRESSIONS, FINISHES AND WALL OPENINGS. <br />DO NOT LOAD THE SLAB -ON -GRADE OR SUPPORTED SLAB WITH ERECTION CRANES OR ANY ERECTION <br />EQUIPMENT. THE SLABS HAVE NOT DESIGNED FOR CRANE LOADS AND WILL REQUIRE AN INCREASE IN <br />THICKNESS AND/OR REINFORCEMENT. OBTAIN ARCH./ENG. APPROVAL ON PROPOSED CRANE SUPPORT <br />PLAN BEFORE COMMENCING WORK. <br />DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON POURED OR ERECTED FLOORS/ROOFS IN <br />EXCESS OF 75% OF LIVE LOAD. GENERAL CONTRACTOR WILL ENSURE THAT ALL SUB -CONTRACTORS <br />ARE INFORMED OF LOADING RESTRICTIONS. AVOID IMPACT WHEN PLACING MATERIALS ON POURED OR <br />ERECTED FLOORS OR ROOF, <br />NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED, OR OTHERWISE REDUCED IN STRENGTH <br />SUBMIT MINIMUM FOUR (4) COPIES OF SHOP DRAWINGS AS REQUIRED. ALLOW ONE WEEK FROM DATE <br />OF RECEIPT FOR REVIEW. <br />ENGINEER ACCEPTS NO RESPONSIBILITY FOR GRADE BEAMS, SLABS, FOOTINGS, AND OTHER <br />STRUCTURAL ELEMENTS UNTIL REVIEW OF APPROVED TRUSS, CONCRETE PLANK, AND OTHER SHOP <br />DRAWINGS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER. <br />DIMENSIONS & COORDINATION <br />DIMENSIONAL INFORMATION, PRICING, ALL DETAILS AND CONSTRUCTION SHALL BE BASED ON THE <br />ENTIRE SET OF CONTRACT DOCUMENTS. COORDINATE THE REQUIREMENTS OF ALL PROFESSIONALS, <br />USE INFORMATION FROM APPROVED SHOP DRAWINGS TO SUPPLEMENT CONTRACT DOCUMENTS WHERE <br />NECESSARY. REPORT ANY DISCREPANCIES TO THE ARCHITECT' PRIOR TO PROCEEDING. IF A CONFLICT <br />EXISTS, THE MORE STRINGENT GOVERNS, <br />THE CONTRACTOR MUST USE STRUCTURAL DRAWINGS IN CONJUCTION WITH ARCHITECTURAL, CIVIL, <br />PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS TO COORDINATE LOCATION OF DEPRESSED <br />SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, OPENINGS, REGLETS, BOLT SETTINGS, SLEEVES <br />DIMENSIONS, ETC. (DRAWINGS NOT BE SCALED) DISCREPANCIES BETWEEN INFORMATION PRESENTED <br />WITHIN PROJECT SPECIFICATIONS AND WITHIN STRUCTURAL NOTES ON PLANS SHALL BE BROUGHT TO <br />THE ATTENTION OF THE ENGINEER BY THE CONTRACTOR PRIOR TO PRESENTING HIS OR HER BID. IF <br />SUCH A DISCREPANCY IS DISCOVERED SUBSEQUENT TO BIDDING, THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR IMPLEMENTING THE OPTION SUBSEQUENTLY SELECTED BY THE ENGINEER AT NO <br />ADDITIONAL COST. CONTRACTORS SHALL BE RESPONSIBLE FOR FINAL VERIFICATION OF ALL <br />DIMENSIONS, ELEVATIONS, CLEARANCES, ETC, OF THE FRAMING SHOWN ON THE STRUCTURAL <br />DRAWINGS AGAINST INFORMATION PROVIDED BY MANUFACTURERS OF SELECTED MECHANICAL <br />EQUIPMENT PRIOR TO PRECEDING WITH ANY RELATED PORTION OF WORK. ITEMS REQUIRING SUCH <br />REVIEW SHALL INCLUDE ELEVATORS (ELEVATOR PITS, BEAMS ABOVE ELEVATOR DOORS, ETC.) <br />ESCALATORS, DUCTS, COOLING TOWERS, ETC. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR <br />ANY REMEDIAL WORK AND FOR ITS IMPACT ON THE WORK SCHEDULE RESULTING FROM FAILURE TO <br />PROVIDE EARLY NOTIFICATION OF SUCH CONFLICTS TO THE DESIGN TEAM. POTENTIAL CONFLICTS, <br />ERRORS OR OMISSIONS PRESENT WITHIN THE DRAWINGS (WHETHER WITHIN STRUCTURAL DRAWINGS <br />OR BETWEEN STRUCTURAL, ARCHITECTURAL AND M.E,P. DRAWINGS) SHALL BE IDENTIFIED BY THE <br />U PROJECT CONTRACTORRING D HIS/HER EARLY REVIEW OF THE PROJ C DOCUMENTS. SUCH CONFLICTS <br />ERRORS OR OMISSIONS SHALL BE COMMUNICATED TO THE ARCHITECT IN WRITING PRIOR TO <br />COMMENCEMENT OF WORK, IN THE EVENT OF FAILURE TO PROVIDE SUCH A NOTICE AND SUFFICIENT <br />TIME FOR A RESPONSE, THE CONTRACTOR SHALL BECAME RESPONSIBLE FOR COST OF ALL WORK <br />OR REMEDIAL WORK RESULTING FROM SUCH CONFLICTS, ERRORS OR OMISSION, AS WELL AS FOR ITS <br />IMPACT ON THE PROJECT SCHEDULE. (CONTRACTOR AGREES THAT HE WILL HOLD OWNER, <br />R AGENTS. <br />ARCHITECT, ENGINEER AND/OR ANY OF THEIR EMPLOYEES O GEN . HARMLESS FROM ANY AND S <br />ALL DAMAGE AND CLAIMS WHICH MAY ARISE BY A REASON OF ANY NEGLIGENCE ON THE PART OF <br />THE CONTRACTOR, OR ANY OF HIS SUBCONTRACTORS, OR ANY MATERIAL AND EQUIPMENT SUPPLIES, <br />AND/OR ANY OF THEIR EMPLOYEES OR AGENTS, IN THE PERFORMANCE OF THIS CONTRACT. IN CASE <br />ANY ACTION IS BROUGHT AGAINST THE OWNER, OR ARCHITECT OR ENGINEER OR ANY OF THEIR <br />EMPLOYEES OR AGENTS, CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DEFENSE THEREOF, <br />TO THE FULL SATISFACTION OF LATTER PARTY. <br />WHERE CRITICAL DIMENSIONS CANNOT BE DETERMINED FROM THE PLANS, OR WHERE NEW WORK <br />ADJOINS EXISTING CONSTRUCTION, OR WHERE ONE MATERIAL ADJOINS A PREVIOUSLY PLACED <br />MATERIAL WITH A MORE RESTRICTIVE TOLERANCE THAN IN -PLACE MATERIAL, CONTRACTOR SHALL <br />TAKE FIELD MEASUREMENTS AS REQUIRED TO COMPLETE SHOP DRAWINGS AND INSTALLATION. <br />REPORT ANY DISCREPANCIES EXCEEDING 3% BETWEEN FIELD MEASUREMENT DIMENSIONS AND SCALED <br />DRAWING DIMENSIONS TO ARCHITECT BEFORE PROCEEDING WITH WORK, DO NOT SCALE DRAWINGS: <br />USE DIMENSIONS. - <br />WHERE A LINE OF STRUCTURE, OPENING LOCATION, OR DIMENSION IS CRITICAL AND BASED ON <br />REQUIREMENTS OF ANOTHER TRADE OR SUBCONTRACTOR, THAT SUBCONTRACTOR SHALL SUBMIT A <br />SHOP DRAWING WITH THE REQUIRED DIMENSIONAL INFORMATION UPON WHICH THE CONTRACTOR <br />SHALL BASE THE LAYOUT AND CONSTRUCTION. THIS PROCEDURE IS MANDATORY FOR CURTAIN WALL <br />SYSTEMS, ARCHITECTURAL PRECAST SYSTEMS, AND ALL MECHANICAL AND ELECTRICAL OPENINGS. <br />THE ENGINEER WILL CLOUD OR OTHERWISE INDICATE REVISIONS TO THESE DOCUMENTS ONLY AFTER <br />THEY HAVE BEEN ISSUED FOR CONSTRUCTION OR FINAL PRICING. CHANGES PRIOR TO THAT DATE <br />WILL NOT BE CLOUDED. CHANGES AND/OR REVISIONS AFTER THE CONSTRUCTION OR FINAL PRICING <br />ISSUE WILL BE CLOUDED IN AN ATTEMPT TO BRING TO, THE CONTRACTOR'S ATTENTION ANY MAJOR <br />ITEMS. HOWEVER, IT SHALL BE SOLELY THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE <br />PRICING AND CONSTRUCTION OF ALL REQUIREMENTS OF THESE DOCUMENTS. INCLUDING REVISIONS <br />(FLAGGED OR UN -FLAGGED) WITH ALL OF HIS SUPPLIERS AND SUBCONTRACTORS. REVISIONS ARE <br />IDENTIFIED BY A REVISION NUMBER WITHIN A TRIANGLE, ALL REVISIONS ISSUED ON A SINGLE DATE <br />WILL BE IDENTIFIED BY THE SAME NUMBER. <br />CONSTRUCTION TO COMPLY WITH REQUIREMENTS OF THE GOVERNING BUILDING CODE, AND ALL <br />OTHER APPLICABLE FEDERAL, STATE, AND LOCAL CODES, STANDARDS, REGULATIONS AND LAWS. <br />DETAILS LABELED AS "TYPICAL DETAILS" ON DRAWINGS AND DETAIL SHEETS. APPLY TO ALL <br />SITUATIONS THAT ARE SIMILAR OR SAME AS THOSE SPECIFICALLY DETAILED, SUCH DETAILS APPLY <br />WHETHER OR NOT THEY ARE KEYED AT EACH LOCATION ON PLAN DRAWINGS, QUESTIONS REGARDING <br />APPLICABILITY OF DETAILS SHALL BE RESOLVED BY THE ARCHITECT OR ENGINEER. <br />CONSTRUCTION DOCUMENTS MUST GET APPROVAL FROM PERMITTING AGENCIES, THUS IT IS <br />UNDERSTOOD THIS SET OF STRUCTURAL DRAWINGS IS NOT ON FINAL FORM UNTIL IT BEARS THE <br />BUILDING DEPARTMENT PLANS REVIEW PROCESS STAMP AND SIGNATURE OF APPROVAL. <br />SHOP DRAWINGS & <br />STRUCTURAL SUBMITTALS <br />SUBMIT TO THE ENGINEER FOUR ORIGINALS ONLY AFTER THEY HAVE BEEN REVIEWED BY THE <br />CONTRACTOR. IF ADDITIONAL COPIES OF ANY MATERIAL ARE REQUIRED, PLEASE PROVIDE SUCH, <br />HOWEVER ONLY THREE COPIES WILL BE MARKED BY THE ENGINEER. <br />UNDER NO CIRCUMSTANCES WILL THE USE OF STRUCTURAL DRAWINGS PREPARED BY THIS OFFICE BE <br />PERMITTED FOR SHOP DRAWING OR BACKGROUND USE, THIS INCLUDES BOTH PHOTOGRAPHIC AND <br />ELECTRONIC REPRODUCTION. SHOP DRAWINGS SHALL BE PREPARED ENTIRELY BY THE VENDOR OR <br />SUBCONTRACTOR GENERATING SUCH SUBMITTAL. <br />THE USE OF ANY DRAWING PREPARED BY THIS OFFICE AS BACKGROUND INDICATES ACCEPTANCE OF <br />TERMS AND CONDITIONS BY OUR OFFICE FOR THEIR USE AND STIPULATED COMPENSATION MUST BE <br />DELIVERED TO OUR OFFICE PRIOR TO SUBMITTAL OF SHOP DRAWINGS, OTHERWISE, SHOP DRAWINGS <br />WILL BE RETURNED NON REVIEWED, <br />REVIEW OF SHOP DRAWINGS IS NOT CONDUCTED FOR DETERMINING THE ACCURACY AND <br />COMPLETENESS OF DETAILS OR FOR SUBSTANTIATING FABRICATION INSTALLATION INSTRUCTION OR <br />PERFORMANCE OF EQUIPMENT OF SYSTEM, ALL OF WHICH SHALL REMAIN THE SOLE RESPONSIBILITY <br />OF THE CONTRACTOR, <br />REVIEW OF SHOP DRAWINGS DOES NOT CONSTITUTE APPROVAL OF SAFETY PRECAUTIONS, <br />CONSTRUCTION MEANS, METHODS, SEQUENCES OR PROCEDURES, NOR DOES IT INDICATES APPROVAL <br />OF ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. COORDINATION OF ALL TRADES SHALL REMAIN <br />THE SOLE RESPONSIBILITY OF THE CONTRACTOR, CONTRACTOR MUST REVIEW ALL QUANTITIES AND <br />DIMENSIONS, <br />ALLOW ADEQUATE TIME FOR TRANSIT, AND PROCESSING BEFORE FABRICATION OUR OFFICE WILL <br />REVIEW AN AVERAGE SUBMITTAL WITHIN 15 CALENDAR DAYS OF RECEIPT DRAWINGS RECEIVED AFTER <br />3:00 PM WILL BE STAMPED AS RECEIVED THE FOLLOWING DAY. REVIEW OF SHOP DRAWINGS IS <br />LIMITED TO TWO REVIEWS PER SUBMITTAL WITHIN THE SCOPE OF BASIC SERVICES, THAT IS ONE <br />INITIAL REVIEW AND ONE ADDITIONAL REVIEW ONCE MARKED ITEMS HAVE BEEN CORRECTED. REVIEW <br />OF ADDITIONAL SUBMITTALS WILL BE CONSIDERED ADDITIONAL SERVICES, FOR WHICH THE <br />CONTRACTOR MAY BE HELD RESPONSIBLE, THOSE ADDITIONAL SERVICES FEES WILL BE IN <br />ACCORDANCE WITH THE TERMS OF THE AGREEMENT FOR THIS PROJECT. OUR OFFICE WILL MARK <br />ONLY THREE SETS OF DRAWINGS REGARDLESS OF HOW MANY COPIES HAD BEEN SUBMITTED, ONLY <br />AFTER DRAWINGS BEAR EVIDENCE OF BEEN REVIEWED AND APPROVED BY THE CONTRACTOR. SHOP <br />DRAWINGS SUBMITTED TO OUR OFFICE WITHOUT CONTRACTORS APPROVAL WILL BE RETURNED UN <br />REVIEWED. <br />SPECIALTY OR DELEGATED ENGINEERING SHOP DRAWINGS: BY DEFINITION A DELEGATED ENGINEER IS <br />A FLORIDA REGISTERED PROFESSIONAL ENGINEER, NOT THE ENGINEER OF RECORD, WHO SPECIALIZED <br />IN AND WHO UNDERTAKES THE DESIGN OF STRUCTURAL COMPONENTS OR STRUCTURAL SYSTEMS <br />INCLUDED IN A SPECIFIC SUBMITTAL PREPARED FOR THIS PROJECT. <br />THE DELEGATED OR SPECIALTY ENGINEER SHALL BE AN EMPLOYEE OR OFFICER OF A FABRICATOR, <br />AN EMPLOYEE OR OFFICER OF AN ENTITY SUPPLYING COMPONENTS TO A FABRICATOR, OR AN <br />INDEPENDENT CONSULTANT RETAINED BY THE FABRICATOR OR HIS SUPPLIER, <br />SUBMITTAL AND RE -SUBMITTAL FOR CUSTOM DESIGNED, MANUFACTURED OR FABRICATED <br />LOAD -CARRYING MEMBERS, COMPONENTS OR ITEMS. SUBJECT TO FORCES OR STRESSES AND THEIR <br />CONNECTION OR ANCHORAGE REQUIRE A DELEGATED OR SPECIALTY ENGINEER. <br />THE FOLLOWING SYSTEMS AND COMPONENTS REQUIRE FABRICATION, AND ERECTION DRAWINGS <br />ALONG WITH SIGNED AND SEALED CALCULATIONS BY A DELEGATED ENGINEER: <br />-ALUMINIUM OR LIGHT GAGE STEEL EXTERIOR WALL SYSTEMS, <br />-GLAZING AND STORE FRONT SYSTEMS, INCLUDING MULLIONS AND CONNECTIONS <br />-POST-TENSIONED CONCRETE MEMBERS <br />-PREFABRICATED WOOD TRUSSES <br />-PRECAST CONCRETE COMPONENTS: WALLS, COLUMNS, JOISTS <br />-CONCRETE TILT -UP WALLS AND COMPONENTS <br />-SHORING AND RE -SHORING DRAWINGS <br />ALL SUBMITTALS SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT AND APPLICABLE CODES, AS WELL <br />AS THE DESIGN CRITERIA WHICH SHOULD NOT BE IN CONFLICT WITH THOSE SPECIFIED ON THE <br />CONTRACT DOCUMENTS, THE APPLICABLE BUILDING CODE NOR THE SPECIFICATIONS. <br />IN CASE OF CONFLICT REQUEST FOR CLARIFICATION MUST BE SUBMITTED IN WRITING TO A/E, OR <br />THE MOST STRINGENT CRITERIA MUST BE USED. SUBMITTAL MUST SHOW ALL DETAILS, PLANS AND <br />NECESSARY INFORMATION FOR THE PROPER FABRICATION AND INSTALLATION OF SYSTEM OR <br />COMPONENTS. CALCULATIONS AND DRAWINGS MUST CLEARLY IDENTIFY SPECIFIC PRODUCTS UTILIZED <br />SINCE GENERIC PRODUCTS WILL NOT BE ACCEPTED. <br />ALL SHOP DRAWINGS AND CALCULATIONS MUST BEAR THE IMPRESSED SEAL, DATE AND SIGNATURE <br />OF THE DELEGATED OR SPECIALTY ENGINEER. IN CASE THAT COMPUTER PRINT-OUTS ARE SUBMITTED <br />THOSE MUST BE ACCOMPANIED WITH DESCRIPTIVE INFORMATION AS OF THE INPUT AND OUTPUT FOR <br />THEIR PROPER EVALUATION. SUCH DESCRIPTION OF COMPUTER PRINT-OUTS MUST BE SIGNED AND <br />SEALED AS WELL WITH A NOTE INDICATING FULL ACCEPTANCE AND LIABILITY OVER THE RESULTS OF <br />SAID COMPUTER PROGRAM, REVIEW BY OUR OFFICE OR OF SUBMITTAL S IS LIMITED TO VERIFYING <br />THAT THE SPECIFIC STRUCTURAL SUBMITTAL HAVE BEEN FURNISHED; THAT THE STRUCTURAL <br />SUBMITTAL HAVE BEEN SIGNED AND SEALED BY THE DELEGATED ENGINEER; THAT THE SPECIFIED <br />CRITERIAS, AND DESIGN INTENT HAVE BEEN FOLLOWED AND UNDERSTOOD BY THE DELEGATED <br />ENGINEER; AND THAT THE CONFIGURATION SET FORTH IN THE STRUCTURAL SUBMITTAL IS <br />CONSISTENT WITH THE CONTRACT DOCUMENTS. <br />NO DETAIL CHECK OF DIMENSIONS OR QUANTITIES WILL BE MADE SINCE THIS TO BE PERFORMED BY <br />THE GENERAL CONTRACTOR. <br />SUBMITTALS NOT MEETING THE ABOVE CRITERIA WILL BE RETURNED NON REVIEWED. <br />CONCRETE <br />A CERTIFIED TESTING AGENCY SHALL PERFORM INDUSTRY -STANDARD TESTING INCLUDING SLUMP <br />TESTS AND CYLINDER BREAKS TO ENSURE CONFORMANCE WITH PLANS AND SPECIFICATIONS. SUBMIT <br />REPORTS TO ARCHITECT AND ENGINEER. <br />REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO A.S.T.M. A615 GRADE 60 (Fy = 60 <br />KSI) AND CONCRETE STRENGTH SHALL BE 3000 PSI AT 28 DAYS. <br />WELDED FIRE FABRIC SHALL BE W/6x6 W2.0xV12.0 WWF CONFORMING WITH A.S.T.M. A185. <br />TIE WIRES SHALL CONFORM WITH A.S.T.M. A82 <br />REINFORCING INSTALLATION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE RECENT ACI <br />CODE. <br />REBARS IN BEAMS, COLUMNS AND SLABS SHALL BE FULLY SECURED PRIOR TO FINAL POUR. <br />REINFORCING STEEL SHALL BE CLEAN AND FREE FROM FOREIGN DEBRIS, NONMETALLIC COATINGS. THE <br />REINFORCEMENT STEEL SHALL ALSO BE FREE FROM RESIDUES SUCH AS OIL, MUD, DIRT, SCALE ANY <br />PITTING AND NICKS THAT IS MORE THAN 2% OF THE TOTAL CROSS SECTIONAL AREA OF ANY REBAR, <br />REINFORCING STEEL SHALL HAVE THE FOLLOWING <br />MINIMUM COVER: <br />ANY CONCRETE POUR AGAINST EARTH 3" <br />ANY FOOTINGS TOP, BOTTOM AND SIDES 3" <br />BEAMS PRIMARY REINFORCEMENT AND STIRRUPS 1.5" <br />COLUMNS PRIMARY REINF., TIES AND SPIRALS 1.5" <br />SLAB ON GRADE BOTTOM COVER 2" <br />SLABS 1,5" <br />VERTICAL BARS IN CONCRETE COLUMNS MUST BE CONTINUOUS. REBARS SHALL BE LAPPED <br />EQUIVALENT TO 48 DIA. OF LARGER SIZE LAPPING BARS OR MIN. 30" OR OTHERWISE AS NOTED. <br />LAPPING BARS MUST BE SECURED WITH MINIMUM WITH 3 TWIST TIES. <br />VERTICAL COLUMN REINFORCEMENT MUST LAP WITH HORIZONTAL REBARS IN BEAMS A LENGHT <br />EQUIVALENT 15 BAR DIA. OF LARGER SIZE LAPPING BARS OR MIN. 12" OR OTHERWISE AS NOTED, <br />LAPPING BARS MUST BE SECURED WITH MIN. (2) TWIST TIES. <br />VERTICAL COLUMN REINFORCEMENT MUST LAP WITH HORIZONTAL REBARS IN FOOTER AND SLAB A <br />LENGTH EQUIVALENT 15 BAR DIA. OF LARGER SIZE LAPPING BARS OR MIN, 12" OR OTHERWISE AS <br />NOTED. LAPPING BARS MUST BE SECURED WITH MIN. (2) TWIST TIES. <br />CORNERS BARS IN CONCRETE BEAMS MUST LAP WITH MAIN BARS IN BEAMS A LENGTH EQUIVALENT <br />TO 42 BAR DIA. OF LARGER SIZE LAPPING BARS OR MIN. 36" OR OTHERWISE AS NOTED, LAPPING <br />BARS MUST BE SECURED WITH MIN. (4) TWIST TIES. <br />CORNERS BARS IN CONCRETE FOOTERS MUST LAP WITH ALL MAIN FOOTER REBARS A LENGTH <br />EQUIVALENT TO 42 BAR DIA, OF LARGER SIZE LAPPING BARS OR MIN. 36" OR OTHERWISE AS NOTED. <br />LAPPING BARS MUST BE SECURED WITH MIN. (4) TWIST TIES. <br />CONTRACTOR IS RESPONSIBLE FOR THE ADEQUACY OF FORMS AND SHORING AND FOR SAFE <br />PRACTICE IN THEIR USE AND REMOVAL. CONTRACTOR TO MAINTAIN FLOORS 100% SHORED. <br />CONTRACTOR SHALL ERECT FORM WORK IN STRICT COMPLIANCE WITH ACI 347. PROVIDE CHAMFERS <br />AT ALL CORNERS IN CONCRETE MEMBERS EXPOSED TO VIEW. FORM WORK TO REMAIN IN PLACE <br />UNTIL CONCRETE HAS ATTAINED ENOUGH STRENGTH TO SUPPORT ALL DEAD LOADS PLUS A MINIMUM <br />OF 50 P.S.F, OF ADDITIONAL CONSTRUCTION LOAD. <br />FOUNDATION NOTES <br />CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. <br />DO NOT SCALE THE DRAWINGS. GO BY DIMENSIONS ONLY. <br />A CERTIFIED TESTING AGENCY SHALL PERFORM INDUSTRY -STANDARD SOIL DENSITY TESTS TO <br />ENSURE CONFORMANCE WITH GEOTECHNICAL SOIL REPORT. SUBMIT REPORTS TO ARCHITECT AND <br />ENGINEER. <br />THERE SHALL BE A 12 HOUR TIME DELAY FOR IMPOSING A LOAD ON A SLAB AFTER CONCRETE <br />PLACEMENT <br />FOUNDATION DESIGN IS BASED ON 2500 PSF NET ALLOWABLE SOIL BEARING CAPACITY. <br />ALL REINFORCING STEEL SHALL BE GRADE 60, AND CONCRETE STRENGTH SHALL BE 3000 PSI AT 28 <br />DAYS. <br />SPLICES IN REINFORCING BARS SHALL NOT BE LESS THAN 36 BAR DIAMETERS AND REINFORCING <br />SHALL BE CONTINUOUS AROUND ALL CORNERS AND CHANGES IN DIRECTION. CONTINUITY SHALL BE <br />PROVIDED AT CORNERS OR CHANGES IN DIRECTION BY BENDING THE LONGITUDINAL STEEL AROUND <br />THE CORNER 48 BAR DIAMETERS OR BY ADDING MATCHING REINFORCING STEEL WHICH SHALL EXTEND <br />48 BAR DIAMETERS FROM EACH CORNER OR CHANGE IN DIRECTION, <br />COLUMN AND WALL CENTERLINES SHALL COINCIDE WITH FOOTING CENTERLINES UNLESS OTHERWISE <br />NOTED, <br />FOR ELEVATION A A COLUMN FOOTINGS AND PADS <br />SEE FOUNDATION PLAN O TOP ELEVA ON OF ALL ISOLATED <br />THE SOIL UNDER ALL FOOTINGS AND GROUND SLABS SHALL BE TREATED WITH AN APPROVED <br />PRE -CONSTRUCTION TERMITICIDE TREATMENT WITH A CERTIFICATE OF COMPLIANCE ISSUED TO THE <br />BUILDING DEPARTMENT PER FBC 1816 AND 2326.5. <br />REINFORCED UNIT MASONRY NOTES <br />THE REINFORCED UNIT MASONRY DESIGN FOR THIS STRUCTURE IS BASED ON RATIONAL ANALYSIS PER <br />F.B.C. SECTION 2118, <br />F.B.C. 2122.1 STATES THAT THE PROVISIONS OF ACI 530-08/ASCE 5-10, BUILDING CODE REQUIREMENTS <br />FOR MASONRY STRUCTURES, AND THE COMMENTARY ON BUILDING CODE REQUIREMENTS FOR <br />MASONRY STRUCTURES, ARE HEREBY ADOPTED AS A MINIMUM: HOWEVER, THE REQUIREMENT OF THE <br />STANDARD SHALL NOT SUPERCEDE THE SPECIFIC REQUIREMENTS OF THIS CHAPTER. <br />REINFORCED UNIT MASONRY SHALL BE STELL REINFORCED SOLID UNIT MASONRY OR STEEL <br />REINFORCED GROUTED HOLLOW UNIT MASONRY. THE DESIGN OF BUILDINGS AND STRUCTURES OF <br />REINFORCED UNIT MASONRY SHALL BE BY PROFESSIONAL ENGINEER OR REGISTRED ARCHITECH. <br />MASONRY UNIT SHALL CONFORM TO A.S.T.M. C90-90 AND SHALL HAVE A MINIMUM PRISM STRENGTH <br />OF 1500 PSI IN 28 DAYS IN ACCORDANCE WITH A.S.T.M. E-447-84. UNITS SHALL BE A MINIMUM OF 48% <br />SOLID. <br />USE TYPE "S" MORTER IN ACCORDANCE WITH A:S.T.M, C-270.92, MASONRY UNITS SHALL HAVE 3/81" <br />FULL BEDDING, MORTER PROTRUDING INTO CELL CAVITIES, THAT ARE REINFORCED AND GROUTED, <br />SHALL BE REMOVED. ALLOW MIN. OF 24 HRS FOR MORTER TO CURE BEFORE PLACING GROUT. <br />GROUT TO BE USED IN FILLED CELLS SHALL BE OF PEA ROCK PUMP MIX WITH A MIN. COMPRESSIVE <br />STRENGTH OF 3000 PSI IN 28 DAYS IN ACCORDANCE WITH F.B.C. 2122.6.5 THE SLUMP SHALL BE 9" (A <br />AND PLACE IN ACCORDANCE WITH F.B.C. 2122,6.5.3. <br />GROUTED CELLS WITH REINFORCING SHALL HAVE A MINIMUM IF (1) # 6 VERTICAL AT EACH CORNER, <br />EACH SIDE OF WALL OPENINGS, AND MAXIMUM OF C-0" THEREAFTER: <br />TIE BEAM AND FILLED CELLS SHALL BE PLACED IN SEPARATE LIFTS AND CONSOLIDATED AS REQUIRED <br />TO COMPLETELY FILL EACH CELL. CLEAN OUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF <br />ALL FILLED CELLS FOR INSPECTION. <br />REINFORCING BARS SHALL BE NEW BILLET STEEL PER A.S.T.M. A615-94, GRADE 60, LAP REINFORCING <br />AS NOTED ON PLANS, <br />CONCRETE MASONRY BLOCKS SHALL BE INSTALLED WITH MASONRY JOINT REINFORCEMENT AT OTHER <br />COURSE, REINFORCEMENT SHALL BE CONTINUOUS WITH (2) BLOCK WIDTH LAPSE AT ENDS AND SHALL <br />BE INSERTED INTO CELLS OR TIE COLUMNS MIN, 4" <br />THE MINIMUM SIZE OF HORIZONTAL JOINT REINFORCEMENT SHALL BE GAUGE 9 "LADDER" TYPE <br />REINFORCEMENT. <br />STANDING SEAM ROOFING NOTES: <br />ALL AREAS WHERE MASTIC TO BE APPLIED SHOULD BE WIPED CLEAN WITH A MILD DETERGANT OR <br />AN ALL PURPOSE CLEANER BEFORE MASTIC APPLICATION. <br />ALL EXPOSED FASTENERS SHOULD PENETRATE THE SEALANT FOR THE MOST WEATHER TIGHT <br />CONNECTION IN ROOF AND WALLS WHERE APPLICABLE <br />ALL SHEET METAL ROOF PANELS SHALL HAVE STRUCTURAL QUALITY ASTM A-792, WITH A MIN, <br />COATING THICKNESS AS PER AZ-55 DESIGNATION, AND WITH MIN. Fy=50 ksi <br />ALL SCREWS TO BE HEX HEAD, SELF DRILLING, NON CORROSIVE <br />ALL ROOF PANEL SIDELAPS AND ENDLAPS SHALL HAVE A CONTINOUS STRIP OF MASTIC SEALER <br />SEE FOUNDATION PLAN FOR <br />REINF, <br />(4) #5 CRANK BARS rd <br />BOTTOM MATCH/OVERLAP <br />WALL FOOTING REINF. <br />36" <br />SEE FOUNDATION PLAN FOR <br />WALL FTG. REINF. <br />• • • • I • • • <br />— — — — — — — �-- <br />PAD FTG. (SEE PLAN) <br />ALONG PIPE LENGTH <br />STRUCTURAL STEEL NOTES <br />STELL WORK SHALL CONFORM TO THE A.I.S.C, SPECIFICATIONS FOR THE DESIGN, FABRICATION AND <br />ERECTION OF STRUCTURAL STEEL BUILDINGS LATEST EDITION. <br />STEEL TUBING SHALL CONFORM TO A.S.T.M. A500 GRADE B. <br />STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL BE A.S.T,M. GRADE A-572 Fy = 50 KSI. ALL OTHER <br />SHAPES SHALL BE A.S.T.M. A36, UNLESS NOTED OTHERWISE. <br />BRACE AND MAINTAIN ALL STEEL IN ALIGNMENT UNTIL OTHER PARTS OF CONSTRUCTION NECESSARY <br />FOR PERMANENT SUPPORT ARE COMPLETED, CPNTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING <br />TEMPORARY SHORING AS REQUIRED FOR THE STABILITY OF THE STEEL FRAME UNTIL ALL <br />STRUCTURAL ELEMENTS HAVE BEEN COMPLETED AND BUILDING IS ENCLOSED. <br />ALL WELDINGS SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD CODE FOR WELDING IN <br />BUILDING CONSTRUCTION OF THE AMERICAN WELDING SOCIETY. WELDING ELECTRODES SHALL BE <br />E70XX- LOW HYDROGENS FOR SHIELD AND METAL ARC WELDING. <br />SHOP WELDING AND FIELD WELDS SHALL BE PERFORMED BY CERTIFIED WELDERS ONLY <br />PRESSURE TREATED WOOD NOTE: <br />ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED OR SEPARATED WITH (2) <br />LAYERS OF 30 LB. BUILDING PAPER. THE USE OFF CCA PRESSURE TREATED, LUMBER IS PROHIBITED, <br />FOR INTERIOR APPLICATIONS (NOT EXPOSED TO WEATHER) PROVIDE SODIUM BORATE (SBX) TREATED <br />LUMBER, FOR EXTERIOR USE PROVIDE COPPER AZOLE (CA) OR AKALINE COPPER QUATERNARY (ACQ) <br />LUMBER. FASTENERS AND CONNECTORS ACCEPTABLE FOR USE WITH PRESSURE TREATED LUMBER <br />SHALL BE HOT DIPPED GALVANIZED. HOT DIPPED GALVANIZED CONNECTORS SHALL MEET ASTM A653, <br />CLASS G185 STANDARDS, HOT DIPPED GALVANIZED FASTENERS SHALL MEET ASTM A153 STANDARDS. <br />FASTENERS USED TOGETHER SHALL BE SAME TYPE (E.G. HOT DIPPED NAILS WITH HOT DIPPED JOIST <br />HANGERSI. TYPE 304 AND 316 STAINLESS STEEL PRODUCTS ARE REQUIRED FOR MAXIMUM <br />CORROSION RESISTANCE, <br />MECHANICAL FASTENER NOTES <br />EXPANSION ANCHORS SHALL BE "POWER STUD" BY RAWL OR "TRU-BOLT" BY ITW RAMSET/REDHEAD <br />OR ENGINEER APPROVED EQUAL. <br />ADHESIVE ANCHORS SHALL BE "POWER "EPCON" BY ITW RAMSET/REDHEAD OR ENGINEER APPROVED <br />OR EQUAL. <br />MASONRY SCREWS"TAPCON " BY ITW RAMSET/REDHEAD OR ENGINEER APPROVED OR EQUAL <br />POWER ACTUATED FASTENERS IPAF) RAMSET/REDHEAD , HILTI <br />r%Al T[%- <br />BOLTS SHALL CONFORM TO ASTM STANDARD A325. <br />ALL BOLT HOLES SHALL BE STANDARD SIZE WITH 1/16 INCH MAXIMUM TOLERANCE, <br />BOLTS TO BE HOT DIPPED GALVANIZED OR ZINC COATED. <br />11 <br />BOLTS TO HAVE WASHERS ON BOTH ENDS. <br />WASHERS TO BE HOT DIPPED GALVANIZED OR ZINC COATED, <br />0 <br />REINFORCING STEEL: <br />REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 GRADE 60 (Fy = 60KS1). <br />WELDED WIRE FABRIC SHALL BE 6"x6"-#10x#10 CONFORMING WITH ASTM A185, <br />TIE -WIRES SHALL CONFORM WITH ASTM A82 <br />REINFORCING INSTALLATION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE RECENT ACI <br />CODE. <br />REBARS IN BEAMS, COLUMNS, AND SLABS SHALL BE FULLY SECURED PRIOR TO FINAL POUR. <br />REINFORCING STEEL SHALL BE CLEAN AND FREE FROM FOREIGN DEBRIS, NONMETALLIC COATINGS. <br />THE REINFORCEMENT STEEL SHALL ALSO BE FREE FROM RESIDUES SUCH AS OIL, MUD, DIRT, SCALE <br />ANY PITTING AND NICKS THAT IS MORE THAN 2% OF THE TOTAL CROSS -SECTIONAL AREA OF ANY <br />REBAR. <br />REINFORCING STEEL SHALL HAVE THE FOLLOWING MINIMUM COVER: <br />ANY CONCRETE POURED AGAINST EARTH 3.0" <br />ALL FOOTINGS TOP, BOTTOM AND SIDES 3.0" <br />BEAMS PRIMARY REINFORCEMENT AND STIRRUPS <br />TOP AND BOTTOM SIDES 1.5" <br />SLAB -ON -GRADE BOTTOM COVER SLABS 2.0" <br />COLUMNS PRIMARY REINFORCEMENT, TIES AND SPIRALS 1.5" <br />VERTICAL COLUMN REINFORCEMENT MUST LAP WITH HORIZONTAL REBARS IN BEAMS A LENGTH <br />EQUIVALENT TO 15 BAR DIAMETER OF LARGER SIZE LAPPING BARS OR MINIMUM 12 INCHES OR <br />OTHERWISE AS NOTED. LAPPING BARS MUST BE SECURED WITH MINIMUM 2 TWIST TIES. <br />VERTICAL COLUMN REINFORCEMENT MUST LAP WITH HORIZONTAL REBARS IN FOOTER AND SLAB A <br />LENGTH EQUIVALENT TO 15 BAR DIAMETER OF LARGER SIZE LAPPING BARS OR MINIMUM 12 INCHES OR <br />OTHERWISE AS NOTED, LAPPING BARS MUST BE SECURED BY MINIMUM 2 TWIST TIES, <br />CORNER BARS IN CONCRETE BEAMS MUST LAP WITH MAIN BARS IN BEAMS A LENGTH EQUIVALENT TO <br />42 BAR 'DIAMETER OF LARGER SIZE BARS. OR MINIMUM 36 INCHES OR OTHERWISE AS NOTED. <br />LAPPING BARS MUST BE SECURED WITH MINIMUM 4 TWIST TIES. <br />CORNER BARS IN CONCRETE FOOTERS MUST LAP WITH ALL MAIN FOOTER REBARS A LENGTH <br />EQUIVALENT TO 42 BAR DIAMETER OF LARGER SIZE BARS OR MINIMUM 36 INCHES OR OTHERWISE AS <br />NOTED, LAPPING BARS SHALL BE SECURED WITH MINIMUM 4 TWIST TIES. <br />WELDING: <br />WELDING WORK SHALL BE COMPLETED IN <br />ACCORDANCE WITH THE RECENT AWI CODE. <br />WELDS SHALL BE WITH E70XX ELECTRODES. <br />WELDING SHALL BE COMPLETED AND CERTIFIED BY A LICENSED AND APPROVED WELDER <br />STEEL JOIST NOTES <br />A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD <br />INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECIFICATIONS, SUBMIT REPORTS TO <br />ARCHITECT AND ENGINEER, <br />ALL DESIGN, FABRICATION AND ERECTION OF STEEL JOISTS AND BRIDGING SHALL BE IN STRICT <br />ACCORDANCE WITH THE CURRENT SPECIFICATIONS OF STEEL JOIST INSTITUDE AND RECOMMENDED <br />CODE OF STANDARD PRACTICE. <br />THE ENDS OF ALL BRIDGING LINES TERMINATING AT WALLS OR BEAMS SHALL BE ANCHORED TO <br />THE WALL OR BEAM. <br />ALL STEEL JOIST ARE TO BE CAMBERED AS SPECIFIED BY S.J.I. <br />PROVIDE BOTTOM AND/OR TOP CHORD EXTENSIONS AS SHOWN ON DRAWINGS. <br />UNLESS NOTED OTHERWISE, MIN. JOIST BEARING SHALL BE 2 1/2" FOR K-SERIES JOIST, 4" FOR LH, <br />DLH AND SLH 15-18, AND 6" FOR SLH 19-25 ON A STEEL MEMBER OR EMBEDDED PLATE. <br />BRIDGING SHALL BE FURNISHED AND INSTALLED TO MEET THE SIZE AND SPACING REQUIREMENTS <br />OF THE S.J.I. STANDARD SPECIFIATIONS FOR OPEN WEB STEEL JOISTS. ALL BRIDGING AND <br />BRIDGING ANCHORS SHALL BE COMPLETELY INSTALLED BEFORE CONSTUCTION LOADS ARE PLACE <br />ON THE JOISTS. ALL JOIST 40'-0" OR LONGER REQUIRE A ROW OF BOLTED BRIDGING TO BE <br />IMPLACE BEFORE SLAKENING OF HOISTING LINES, OTHER JOISTS REQUIRE SIMILAR BRIDGING <br />(CONSULT LATES S.J.I. SPECIFICATIONS) <br />CONTRACTOR TO FURNISH BAR JOIST CERTIFICATIONS SIGNED AND SEALED BY AN ENGINEER <br />REGISTRED IN THE STATE OF FLORIDA. . <br />FOR NET UPLIFTS SEE NET UPLIFT PLAN. PROVIDE UPLIFT BRIDGING. <br />ALL ITEMS SUSPENDED FROM JOISTS (I.E., CAT WALKS, BALCONIE, OPERABLE PARTITIONS, ETC.) <br />SHALL BE INSTALLED AFTER DEAD LOAD HAS BEEN APPLIED. <br />ANY STEEL JOIST WITHIN A 4'-0" DISTANCE FROM A PARALLEL SUPPORT SHALL BE FABRICATED IN <br />SUCH A WAY THAT CAMBER OF THE JOIST NOT CAUSE_ A PROBLEM INSTALLING THE METAL DECK. <br />(4) #5 BAR ON TOP. LINE UP <br />WITH BOTTOM BARS <br />DIAGONALLY PLACED <br />EXISTING 6" PIPE IN <br />PROTECTIVE SLEEVE <br />(4) #5 CRANK BARS la <br />BOTTOM MATCH/OVERLAP <br />WALL FOOTING REINF. <br />36" <br />#5 TRANSERVE <br />BARS fd 12" 0/0 <br />MI i <br />- ' 11 <br />� ', \ 11 11 , I= I <br />�' s' J ` <br />SCALE; N.T.S. <br />CONC. FILLED PRE-FAB. <br />LINTEL <br />BREAK 3"x5" PRE-FAB. <br />KNOCKOUT AT LINTEL TO <br />ALLOW NELSON STUD <br />6"x6"x5/8" STL. ANGLE w/0) <br />5/8" DIA. x 4" NELSON STUD <br />STL.. COL <br />TYP. <br />TYP. LINTEL @ STL. COLUMN <br />SCALE; N.T.S. <br />TIE BEAM REINFORCING NOTES <br />TIE COLUMN REINFORCING BAR SPLICES SHALL BE LAPPED 30" MINIMUM. <br />VERTICAL REINFORCING BARS SHALL BE PLACED IN CONCRETE FILLED CELLS AND SHALL EXTEND <br />INTO THE FOOTINGS AND INTO THE BEAM. ALL SUCH BARS SHALL BE CONTINUOUS FROM FOOTING <br />TO TIE BEAM, AND SHALL TERMINATE AT EACH END WITH A STANDARD ACI HOOK. <br />SPLICES IN TIE BEAM REINFORCING STEEL ON STRAIGHT RUNS SHALL BE PROVIDED <br />BY LAPPING MINIMUM 30". <br />SPLICES IN TIE BEAM REINFORCING STEEL AROUND CORNERS SHALL BE PROVIDED <br />BY BENDING TWO BARS, ONE OUTSIDE TOP AND ONE OUTSIDE BOTTOM AROUND CORNER 30" <br />MINIMUM, OR BY ADDING TWO #5 BARS, ONE OUTSIDE TOP AND ONE OUTSIDE BOTTOM WHICH <br />EXTENDS 30" EACH WAY FROM CORNER. <br />TIE BEAMS SHALL HAVE (4) # 3 TIES AT 12 INCHES O.C. AT CORNERS AND AT EACH BEND AND <br />AT 36 INCHES O.C. ELSEWHERE, PER F.B.C. 2121.2.3.2. <br />LIGHTGAGE METAL FRAMING <br />A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD <br />INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECIFICATIONS. SUBMIT <br />REPORTS TO ARCHITECT AND ENGINEER OF RECORD. <br />CONNECT STEEL STUDS AND TRACKS TO A36 STEEL OR CONCRETE WITH (2) POWDER <br />ACTUATED FASTENERS (PAF) AT EACH STUD AND CONNECT STEEL STUDS AND TRACKS <br />TO EACH OTHERS WITH (2) #8-18 SCREWS AT EACH STUD (TYPICAL UNLESS NOTED <br />OTHERWISE) SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND EXTENDS OF <br />STEEL STUD WORK. <br />NOTE: "POWDER ACTUATED FASTENERS (PAF) REFERS TO 0,145 DIA. SHANK DOMED -HEAD, <br />LOW VELOCITY POWDER ACTUATED FASTENERS AS MANUFACTURED BY POWERS RAWL <br />OR APPROVED EQUAL WITH MINIMUM CAPACITIES AS FOLLOWS: <br />IN 3000 PSI CONCRETE: 1 y" PENETRATION = <br />185# PULLOUT & 225# SHEAR <br />IN A36 STEEL Y" MATERIAL = <br />430# PULLOUT & 660# SHEAR <br />(PIN MUST BE FULLY PENETRATED THE MATERIAL BY <br />A" MINIMUM) <br />STELL STUDS SHALL MEET FOLLOWING DESIGN <br />CRITERIA: GALV.G-20 ASTM A525, MINIMUM <br />YIELD STRESS SHALL BE 50,000 PSI FOR 12ga, 14ga, <br />16ga AND 33000 PSI FOR 18ga & 20ga <br />1. SEE PLAN AND SECTIONS FOR SIZES REQUIRED. <br />2, ALL SIZES SHALL HAVE 1%8" FLANGES <br />BRACING DURING CONSTRUCTION: <br />PROVIDE 1%" COLD -ROLLED CHANNELS OR HORIZONTAL STRAP BRACING FOR WALLS IMMEDIATELY <br />AFTER STUDS ARE ERECTED. <br />EXECUTION: <br />POSITION STUDS VERTICALLY IN RUNNERS AND SPACE NO GREATER THAN 16". SECURELY ANCHOR <br />EACH STUD TO RUNNER WITH (4) #8-18 LOW PROFILE SCREWS, TWO TOP AND TWO AT BOTTOM, <br />WITH ONE SCREW IN EACH FLANGE, TRACKS SHALL BE SECURELY ANCHORED TO THE <br />SUPPORTING STRUCTURE AS SHOWN ON PLANS, AT TRUCK BUTT JOINTS, ABUTTING PIECES OF <br />TRACK SHALL BE SECURELY ANCHORED TO A COMMON STRUCTURAL ELEMENT, OR THEY SHALL <br />BE BUTT -WELDED OR SPLICED TOGETHER. JACK STUDS OR CRIPPLES SHALL BE INSTALLED BELOW <br />WINDOW SILLS, ABOVE WINDOW AND DOOR HEADS, AT FREE STANDING STAIR RAILS, AND <br />ELSEWHERE TO FURNISH SUPPORT, AND SHALL BE SECURELY ATTACHED TO SUPPORTING <br />MEMBERS. PROVISIONS FOR STRUCTURAL VERTICAL MOVEMENT SHALL BE PROVIDED WHERE <br />INDICATED ON THE PLANS. SPLICES IN AXIALLY LOADED STUDS SHALL NOT BE PERMITTED. <br />EXTERIOR CEILING SHEATHING: <br />ATTACH GYPSUM SHEATHING TO EXTERIOR OF EACH STUD WITH 1" TYPE(S) S-12 COATED SCREWS <br />SPACED 3/8"FROM ENDS AND EDGES AND AT 4" O/C. <br />LATERAL BRACING (HORIZANTAL BRIDGING) FOR WALLS: <br />ENSURE BOTH STUDS FLANGES ARE ATTACHED TO TOP AND BOTTOM RUNNER FLANGES. <br />HORIZONTAL BRIDGING MUST BE INSTALLED AT SPACING NOT TO EXCEED 48" O/C MEASURED <br />VERTICALLY FOR AXIAL LOAD BEARING WALLS:: <br />METAL STUD INSTALLATION: <br />METAL STUD SHALL EXTEND INTO ALL TRACKS UNTIL IT IS WITHIN y" OF THE TRACK WEB, <br />NO METAL STUD TRACKS SHALL EXTEND PAST THE EDGE OF THE SUPPORT MORE THAN ONE <br />THIRD OF ITS WIDTH (e.g. A 6" TRACK MAY EXTEND BEYOND THE EDGE OF SUPPORT A MAX. OF <br />6/3=2") <br />NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED, OR OTHERWISE <br />REDUCED IN STRENGTH BEYOND THE SCOPE OF THIS PLAN WITHOUT <br />CONSULTING ENGINEER OF RECORD. <br />REPORT ANY DISCREPENCIES TO ENGINEER IMMEDIATELY <br />CENTER OF NEW STEEL COLUMN = CENTER OF NEW PAD FOOTING <br />ECCENTRICITY IS NOT ALLOWED U.O.N. <br />ALL FIELD CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR <br />PRIOR TO COMMENCING THE CONSTRUCTION <br />ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE <br />PROVIDED TO SAFELY SUPPORT ALL LOADS DURING <br />INSTALLATION <br />DESIGN CRITERIA <br />ALL WORK SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2010 <br />EDITION ALONG WITH ALL APPLICABLE STATE AND LOCAL CODES, <br />ORDINANCES AND REGULATIONS <br />APPLICABLE BUILDING & DESIGN CODES: <br />1) FLORIDA BUILDING CODE 2010 EDITION <br />2) ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL <br />CONCRETE, THE LATEST EDITION <br />3) CRSI MANUAL OF STANDARD PRACTICE, THE LATEST EDITION <br />4) STRUCTURAL WELDED WIRE REINFORCEMENT OF STANDARD <br />PRACTICE, WIRE REINFORCEMENT INSTITUTE <br />5) ACI 530/ASCE 5 BUILDING CODE REQUIREMENTS FOR <br />MASONRY STRUCTURES, THE LATEST EDITION <br />DESIGN LOADS: <br />1) WIND DESIGN LOADS; <br />WIND LOADING SHALL COMPLY TO ASCE 7-10 <br />WIND VELOCITY <br />140 MPH <br />EXPOSURE CATEGORY <br />C <br />RISK CATEGORY II <br />INTERNAL PRESSURE <br />COEFFICIENT = -/- 0.18 <br />Kd = 0.85 <br />MEAN ROOF HEIGHT <br />20'-0" <br />NET UPLIFTS SHOWN <br />HEREIN ARE BASED ON (GROSS UPLIFT) <br />PER ASCE 7-10 ASD <br />DESIGN (0.6W: NO FURTHER REDUCTION <br />ALLOWED), COMPONENTS <br />& CLADDING ZONES 1, 2 AND 3. <br />ZONE 1 .... .. . .. .... . .. <br />... .. .......... .... - 28.0 PSF <br />ZONE 2 -. ...... ..... .. <br />..... ............ ... - 46.0 PSF <br />ZONE 3. ............................................................. <br />- 69.0 PSF <br />a = END ZONE DISTANCE 8'-0" <br />a <br />a=END ZONE DISTANCE <br />ROOF ZONES <br />THE PRESSURES PROVIDED IN THE TABLE <br />ARE INFORMATION <br />PURPOSES ONLY. IT IS APPLICABLE ONLY <br />FOR GENERAL <br />CONDITIONS AND DOES NOT COVER ANY <br />SUPPORT BUILDING. <br />REFER TO BUILDING CODE FOR SPECIFIC <br />CONDITIONS AND <br />REFER TO WINDOW/DOOR SCHEDULES FOR OPENING PRESSURES. <br />2) ROOF DESIGN LOADS; <br />ROOF LIVE LOAD <br />30 PSF <br />ROOF DEAD LOAD <br />30 PSF <br />ROOF DEAD LOAD FOR UPLIFT DESIGN <br />0 PSF <br />SLAB -ON -GRADE LIVE' LOAD <br />100 PSF <br />TO THE BEST OF ENGINEER'S KNOWLEDGE, <br />THE STRUCTURAL <br />PLANS AND SPECIFICATIONS HAVE BEEN <br />DESIGNED IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODE 2010 <br />EDITION <br />0 <br />kYLAN KALKAN, P.E. <br />ENGINEERING PLUS <br />,. P.E. # 67349 & C.A. # 26538 <br />.9528 SEDGEFIELD TERRACE <br />BOCA RATON, FL 33498 <br />p61) 756 4106 (561) 479 3743 fax <br />Prof. Mgr. <br />JU <br />Job. Capt. <br />SG <br />Drawn bS <br />JT <br />RON BARR, A.I.A. <br />IZev-cl by <br />STATE OF FLORIDA <br />IR5 <br />AR 0016160 <br />O <br />w O <br />�_ <br />U m <br />w <br />O z z <br />U <br />W <br />t- O <br />H W <br />Fw- <br />H W <br />= H <br />z 3:0 <br />W <br />U p <br />W. W W <br />Q <br />o m <br />a o <br />a o W o w <br />d 0 <br />W O <br />O S V p= z� W <br />Wm <br />W I <br />m�o <br />0wO m <br />X o <br />Z Z <br />U <br />� <br />W <br />'Ul W <br />O <br />>z <br />Z OO Z m 0 <br />U. <br />M Z <br />>' <br />mm = <br />W <br />o it a z z F o <br />o <br />m <br />LL <br />D a- O i i Z= Z <br />W_ <br />M, <br />a m <br />UJ <br />z z p a 0 <br />O <br />pw. <br />0 <br />2= <br />m~ <br />. <br />°' W <br />z,f O D U z U <br />GU Q <br />coW0 <br />Z <br />fn <br />w <br />J >- �- <br />z <br />Fo°�Z~Waz <br />z <br />O m W o <br />W <br />s n <br />F 0 <br />0 <br />W F- <br />U Z W U a 0 w <br />_ w <br />m) <br />Q a H <br />C� <br />O F_ W W cn <br />U w <br />U <br />z x O o U s a_ <br />o V <br />O <br />Z m U <br />v F W¢ s W s 0 <br />m <br />V <br />m <br />. <br />a n a <br />�_ <br />COPYRIGHT 2012 <br />BARR ARCHITECTURAL STUDIO <br />Ravieione: <br />1� GENERAL REVISIONS (09/30/2013) <br />Z AS BUILT <br />(04/24/2014) <br />CADFILE No. <br />ti/ <br />p`01 <br />H <br />a <br />M <br />00 <br />M <br />O <br />= <br />•_01� <br />A <br />A <br />gao <br />19 <br />-.� <br />�D <br />^ <br />04 <br />ell <br />12 <br />aw_41ta <br />4 <br />04 <br />— <br />0—— m <br />,� <br />V <br />)4 <br />r4 <br />: <br />� <br />W <br />= <br />enH <br />*,4 <br />y <br />I' <br />4 <br />O <br />w <br />N <br />E* <br />&hoet Title <br />Scale: <br />Emm L <br />O <br />ESL <br />m Q C <br />M <br />cu N <br />- N 'E <br />L.L r C <br />N 2 <br />0_ <br />.> <br />0 0) N <br />ti <br />* 0) <br />=; N <br />E <br />it .0 <br />O In L_ <br />N <br />N 0 C <br />co r � <br />O Lo Lo = <br />co UA <br />'T + 0) W <br />Irl- t! <br />to U <br />L <br />� cu <br />Date: <br />5-5-2014 <br />Project No. <br />12-027 <br />Shoat No. <br />S-i <br />