REVISIONS <br />BULLETIN #1 <br />APRIL 16, 2007 <br />SALES AREA POWER REQUIREMENT SCHEDULE <br />SYMBOL <br />SERVICE <br />LOAD DESCRIPTION <br />SOURCE <br />CIRCUITS <br />VOLTAGE <br />LOAD <br />WIRE/ <br />EXISTING PANEL <br />REQUIRED <br />AMPS <br />CONDUIT SIZE <br />FOUR (4) 20A <br />6#10 & 1 #12 GND <br />O <br />DAIRY -MILK <br />COOLERS <br />NEAREST 120V <br />NON-CR & NON -TIMED <br />1-POLE, GFCI <br />12010 <br />10.OA <br />IN 3/4" C <br />CITRUS <br />BREAKERS <br />EACH <br />EACH <br />SWITCHED PANEL <br />CKTS. <br />WALL -MOUNTED <br />MULTIOUTLET PLUG-IN <br />NEAREST 120V <br />THREE (3) 20A <br />120V 10 <br />10.OA <br />4#12 & 2#12 <br />O <br />ELECTRONICS <br />STRIPS FOR TV'S, COMBO <br />NON-CR &NON -TIMED <br />1-POLE, CKTS. <br />EACH <br />EACH <br />GND IN 3/4"C <br />TV'S AND HDTV'S <br />SWITCHED PANEL <br />TV, HOME THEATRE, <br />O <br />ELECTRONICS <br />VCR,DVD, HDTV'S, <br />NEAREST 120V <br />NON-CR & NON -TIMED <br />FIVE (5) 20A <br />120V 10 <br />10.0A <br />7#12 & 1 #12 <br />INTERACTIVE DISPLAY, <br />1-POLE CKTS. <br />EACH <br />EACH <br />GND-3/4"C <br />BOOM BOXES, VIDEO GAMES <br />SWITCHED PANEL <br />4A <br />CASH REGISTER IG <br />NEAREST 120V "CR" <br />2#12 & 1 #12 IG A"C <br />RECEPTACLE <br />PANEL <br />46 <br />ELECTRONICS <br />SHOWCASE LIGHTING <br />TIME -CONTROLLED <br />ONE (1) 20A <br />120V 10 <br />10.OA <br />2#12 & 1 #12 GND - <br />208Y/120V <br />1-POLE CKT. <br />EACH <br />EACH <br />1/2"C. <br />4C <br />GENERAL PURPOSE <br />NEAREST 120V <br />NON -CH & NON -TIMED <br />2#12 & 1 #12 GND. <br />RECEPTACLE <br />SWITCHED PANEL <br />-AC <br />O <br />ELECTRONICS <br />MULTI -OUTLET PLUG-IN STRIPS <br />NEAREST 120V <br />NON-CR & NON -TIMED <br />THREE (3) <br />20A 1-POLE <br />120V 10 <br />10.OA <br />4#12 & 1#12 <br />SWITCHED PANEL <br />CKT. <br />EACH <br />EACH <br />GND-1/2"C <br />NEAREST 120V <br />TWO (2) 20A <br />120V3#12 <br />10 <br />& 1#12 <br />0 <br />CORD REELS <br />GENERAL PURPOSE <br />NON-CR & NON -TIMED <br />1-POLE CKT. <br />EACH <br />EACH <br />GND 1/2"C <br />RECEPTACLE <br />SWITCHED PANEL <br />2 REELS/ CKT <br />EACH <br />EACH <br />STOCKROOM <br />GENERAL PURPOSE <br />NEAREST 120V <br />ONE (1) 20A <br />12010 <br />1&0A <br />2#12 & 1#12 <br />O <br />DESK <br />RECEPTACLE <br />NON-CR & NON -TIMED <br />1-POLE CKT. <br />EACH <br />EACH <br />GND - 1/2"C <br />SWITCHED PANEL <br />8O <br />STOCKROOM <br />IG RECEPTACLE <br />NEAREST 120V "CR2„ <br />ONE (1) 20A <br />1-POLE CKT. <br />120V 10 <br />10.OA <br />2#12 & 1#12 , <br />GND. & #12 ISO <br />DESK <br />PANEL <br />EACH <br />EACH <br />GND -3/4"C <br />(I) 20A <br />GENERAL PURPOSE <br />NEAREST 120V NON-CR <br />1-POLE CKT. <br />120V 10 <br />2#12 & 1 #12 GND <br />9 <br />O <br />FITNESS <br />RECEPTACLE <br />&NON TIMED <br />EACH <br />10.0A <br />-1/2 C <br />SWITCHED PANEL <br />APPLIANCE <br />GENERAL PURPOSE <br />NEAREST 120V NON-CR <br />ONE 1 20A <br />120V 10 <br />2#12 & 1#12 GND <br />10 <br />O <br />WALL <br />RECEPTACLE <br />& NON -TIMED <br />1-POLE CKT. <br />EACH <br />10.OA <br />-1/2"C <br />SWITCHED PANEL <br />MULTI -OUTLET <br />NEAREST 120V TIMED <br />ONE(1) 20A <br />120V 10 <br />2#12 & 1 #12 <br />0LAMPS <br />PLUG-IN STRIPS <br />SWITCHED <br />1-POLE CKT <br />EACH <br />10.OA <br />GND-1/2"C <br />, ',*N <br />SPORTING <br />CASH REGISTER IG <br />NEAREST 120V "GRi" <br />ONE(1) 20A120V <br />10 <br />2#12 & 1#12 <br />kzj <br />GOODS <br />RECEPTACLE <br />PANEL <br />1-POLE CKT. <br />EACH <br />10.OA <br />, <br />GND. & #12 ISO <br />GND -3/4"C <br />13 <br />FLOORCARE <br />GENERAL PURPOSE <br />NEAREST 120V NON-CR <br />& NON <br />ONE(1) 20A <br />120V 10 <br />RECEPTACLE <br />-TIMED <br />1-POLE CKT. <br />EACH <br />10.0A <br />2#12 & 1 #12 <br />SWITCHED PANEL <br />GND.-1/2"C <br />01 <br />GUNCASE LIGHTING CKT. <br />NEAREST 120V NON-CR <br />ONE(1) 20A <br />4.OA <br />2#12-1#12 <br />SPORTING <br />& NON -TIMED <br />1-POLE CKT. <br />120V 10 <br />GRID - 1/2"C <br />0GOODS <br />1 120V GEN. PURPOSE CKT, <br />SWITCHED PANEL <br />EACH <br />4.OA <br />2#12 & 1 #12 <br />GND: 1/2"C <br />GENERAL PURPOSE <br />NEAREST 120V NON-CR <br />ONE(1) 20A <br />120V 10 <br />14.0A <br />2#12 & 1 #12 <br />15 <br />MOBILE CARTS <br />& NON -TIMED <br />1-POLE GFCI <br />EACH <br />GND-1/2"C <br />RECEPTACLE <br />SWITCHED PANEL <br />CKT. <br />SMALL <br />UNDERSHELF DISPLAY <br />NEAREST 120V TIMED <br />TWO (2) <br />120V 10 <br />10.OA <br />3#12& 1 #12 <br />ig <br />APPLIANCES <br />LIGHTING <br />CKT. <br />1-POLE CKT. <br />EACH <br />EACH <br />GND: 1/2"C EACH <br />GND. <br />17 <br />OME APPLIANCES <br />MULTIOUTLET <br />NEAREST 120V <br />FIVE (5) 20A <br />120V 10 <br />10.OA <br />7#12 & 2#12 <br />PLUG-IN STRIPS <br />NON-CR & NON -TIMED <br />1-POLE <br />EACH <br />EACH <br />GND-3/4"C <br />SWITCHED PANEL <br />18 <br />OME APPLIANCES <br />CASH REGISTER IG <br />NEAREST 120V "CRV <br />ONE (1) 20A <br />120V 10 <br />10.OA <br />2#12 & 1 #12 , <br />RECEPTACLE <br />PANEL <br />1-POLE <br />EACH <br />EACH <br />GND. & #12 ISO <br />GND -3/4"C <br />19 <br />SALES AREA <br />EXTERIOR SIGNAGE <br />NEAREST 120V <br />NON -OR & NON -TIMED <br />ONE (1) 20A <br />1-POLE <br />120V 10 <br />5.OA <br />2#12 & 1 #12 GND <br />EACH <br />1/2"C <br />SWITCHED PANEL <br />SALES AREA <br />AUTOMATIC <br />NEAREST 120V <br />ONE (1) 20A <br />120V 10 <br />2#12 & 1 #12 GND <br />20 <br />DOOR OPENER <br />NON-CR & NON -TIMED <br />1-POLE <br />EACH <br />10.0A <br />-1/2"C <br />SWITCHED PANEL <br />NEAREST 120V <br />ONE (1) 20A <br />120V 10 <br />10.OA <br />2#12 & 1#12 GND <br />SALES AREA <br />EAS <br />NON-CR & NON -TIMED <br />1-POLE <br />EACH <br />-1/2"C <br />21 <br />SWITCHED PANEL <br />GENERAL PURPOSE <br />NEAREST 120V NON-CR <br />ONE (1) 20A <br />120V 10 <br />2#12 & 1#12 GND <br />0SALES <br />AREA <br />RECEPTACLE <br />& NON -TIMED <br />1-POLE CKT. <br />EACH <br />10.OA <br />-1/2"C <br />SWITCHED PANEL <br />23 <br />SALES AREA <br />IG RECEPTACLE <br />NEAREST 120V "CR2" <br />ONE (1) 20A <br />1-POLE CKT. <br />120V 10 <br />10.OA <br />2#12 & 1 #12, <br />GND. & #12 ISO <br />PANEL <br />EACH <br />EACH <br />GND -3/4"C <br />24 <br />JEWELRY <br />CASH REGISTER IG <br />NEAREST 120V "CR" <br />ONE (1) 20A <br />120V 10 <br />4.0A <br />2#12 & 1#12 , <br />GND. & #12 ISO <br />RECEPTACLE <br />PANEL <br />1-POLE CKT. <br />EACH <br />GND -3/4"C <br />0NEAREST <br />JEWELRY <br />120V <br />TIMED SWITCHED <br />ONE (1) 20A <br />120V 10 <br />2.OA <br />2#12 & 1 #12 <br />DISPLAY LIGHTING <br />PANEL "K1" <br />1-POLE CKT. <br />EACH <br />GND -1/2"C <br />GENERAL PURPOSE <br />NEAREST 120V <br />ONE (1) 20A <br />26 <br />JEWELRY <br />RECEPTACLE <br />NON-CR & NON -TIMED <br />1 -POLE CKT. <br />120V 10 <br />1 <br />10.OA <br />2#12 & 1 #12 <br />SWITCHED PANEL <br />EACH <br />GND -1/2"C <br />27 <br />INTERNET KIOSK, <br />NEAREST 120V "CR" <br />FOUR (4) <br />120V 10 <br />10.OA <br />6#12 & 1 #12 , <br />E-HIRE CONSOLE <br />IG RECEPTACLE <br />PANEL <br />20A 1-POLE <br />EACH <br />EACH <br />GND. & #12 ISO <br />& GIFT REGISTRY <br />CKT. <br />GND -3/411C <br />SALES AREA <br />AUTOMATIC <br />NEAREST 120V <br />ONE (1) 20A <br />120V 10 <br />10.OA <br />2#12 & 1 #12 GND <br />28 <br />DOOR OPENER <br />NON-CR & NON -TIMED <br />1-POLE <br />EACH <br />-1/2"C <br />SWITCHED PANEL <br />lL J � 440 � 0® O ® O <br />NORTH <br />ELECTRICAL NOTES AND SPECIFICATIONS <br />1. INSTALLATION OF ELECTRICAL WORK SHALL CONFORM WITH LOCAL REGULATIONS AND <br />ORDINANCES, STATE REQUIREMENTS AND THE LATEST NATIONAL ELECTRICAL CODE. <br />2. ELECTRICAL CONTRACTOR SHALL VISIT JOB SITE AND DETERMINE EXISTING CONDITIONS AND <br />LIMITATIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THE SUBMISSION OF A BID <br />SHALL BE CONSTRUED AS INDICATING SUCH KNOWLEDGE THAT SUCH EXAMINATION HAS <br />BEEN MADE AND VERIFIED. <br />3. MAKE APPLICATION FOR AND PAY ALL FEES IN CONNECTION WITH ANY PERMITS, <br />INSPECTIONS, TESTS, ETC., THAT MAY BE REQUIRED FOR ALL JOBS. <br />4. FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT AS SHOWN OR REQUIRED TO <br />COMPLETE THE WORK. <br />5. NEW INSTALLATION INCLUDING MATERIAL AND EQUIPMENT SHALL BE EQUAL TO ORIGINAL <br />INSTALLATION. <br />6. GUARANTEE ALL WORKMANSHIP, MATERIAL AND PERFORMANCE FOR A PERIOD OF ONE (1) <br />YEAR FROM DATE OF FINAL ACCEPTANCE, <br />7. ALL NEW CONDUCTORS SHALL BE COPPER TYPE THHN (ABOVE GROUND) RUN IN <br />ELECTRICAL METALLIC TUBING (EMT/THIN WALL) AND TYPE THWN (BELOW GROUND) RUN IN <br />RIGID CONDUIT. PROVIDE COMPRESSION TYPE FITTINGS FOR EMT. <br />8. MATERIAL NOT SPECIFIED SHALL BE EQUAL IN QUALITY TO EXISTING MATERIAL OF LIKE KIND. <br />9. ELECTRICAL CONTRACTOR SHALL PROVIDE TYPED -IN DIRECTORY FOR NEW PANELS AND <br />EXISTING PANELS BEING AFFECTED BY THIS WORK. <br />10. ALL ELECTRICAL DISTRIBUTION EQUIPMENT(i.e. PANELBOARDS etc.) ARE EXISTING TO REMAIN <br />UNLESS NOTED AS NEW. <br />11. PROVIDE AN INSULATED, ISOLATED GROUND SYSTEM THROUGHOUT AS INDICATED ON <br />DRAWINGS FOR ELECTRONIC CASH REGISTER (ECR) SYSTEM. PROVIDE ONE INSULATED <br />ISOLATED GROUND WIRE FOR EACH CIRCUIT. PLACE ONLY, A MAXIMUM OF TWO (2) ECRS ON <br />A SINGLE ISOLATED GROUND POWER CIRCUIT, <br />12. RECEPTACLES FOR ISOLATED GROUND CIRCUITS SHALL BE AS FOLLOWS: <br />SINGLE - HUBBELL #IG5251 (ORANGE) <br />DUPLEX - HUBBELL #IG5262 (ORANGE) EXCEPT AS OTHERWISE NOTED, <br />13. PROVIDE SCREW FASTENED HANDLE LOCK -ON DEVICES AT CIRCUIT BREAKERS FOR ALL <br />REFRIGERATION EQUIPMENT, CASH REGISTERS AND AS DIRECTED IN FIELD BY KMART <br />PROJECT REPRESENTATIVE. <br />COORDINATOR PRIOR TO INSTALLATION. <br />15. HOMERUNS SHOWN SEPARATE FOR CLARITY ONLY. CIRCUITS MAY BE COMBINED FOR MOST <br />COST EFFECTIVE INSTALLATION, BUT MUST COMPLY WITH ARTICLE #310 DEBATING FACTORS <br />FROM THE LATEST NATIONAL ELECTRIC CODE. <br />16, IT IS THE RESPONSIBILITY OF THIS ELECTRICAL CONTRACTOR TO VERIFY AT THE JOB <br />SITE ACTUAL AVAILABILITY OF CIRCUITS REQUIRED. CIRCUITS INDICATED ARE <br />TENTATIVE. DIFFERENT CIRCUITS THAT HAVE BECOME AVAILABLE IN THE CEILING <br />SPACE DUE TO RELOCATION OF ELECTRIFIED DEVICES SUCH AS CORD REELS OR <br />LIGHTED DISPLAYS CAN BE SUBSTITUTED TO CIRCUITS INDICATED ON THE DRAWINGS, <br />IF THOSE CIRCUIT ARE COMING FROM SOURCE PANELS OF THE SAME ELECTRICAL <br />CHARACTERISTICS. <br />17. RETRACTABLE EXTENSION CORD REEL TO BE PLUGGED INTO ADJACENT FLUSH MOUNTED <br />CEILING RECEPTACLE. CORD REELS WILL BE FURNISHED BY KMART. <br />18. THE INTENTION OF THESE DRAWINGS IS TO INDICATE THE ROUGH IN POWER <br />REQUIREMENTS FOR STORE MERCHANDISE FIXTURES AND CASH REGISTERS. IT SHALL BE <br />THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY THE EXACT LOCATION <br />OF EACH OUTLET WITH THE KMART PROJECT REPRESENTATIVE USING FINAL STORE <br />PLANNING FIXTURE LAYOUT FOR FINAL INSTALLATION. <br />19. ALL OUTLET BOXES FOR DROPS TO SALES AREA FIXTURES MUST BE LOCATED IN CEILING <br />SPACE AND SECURED TO ROOF STEEL. <br />20. ALL WIRES SHALL BE LABELED WITH AN IDENTIFICATION TAG TO INDICATE THEIR <br />DESTINATION. <br />21. FOR MOBILE CART (WHEEL CHAIRS) CHARGER ELECTRICAL CONTRACTOR SHALL <br />FURNISH AND INSTALL HUBBELL #HBL5362GY RECEPTACLE IN A FLOOR -SUPPORTED <br />CAST ALUMINUM BOX FLUSH WITH CART RAILING. PROVIDE STAINLESS STEEL PLATE. <br />CONNECT TO A GFCI CIRCUIT FROM THE NEAREST NON-09 AND NON -TIMED SWITCHED <br />PANEL, WHERE APPLICABLE FURNISH AND INSTALL ALUMINUM CHANNEL ALONG <br />VESTIBULE MULLIONS FOR CONDUIT COVER. <br />22. MINIMUM CONDUCTOR SIZE FOR HOMERUNS SHALL BE #12 THHN IN 2" CONDUIT. MAKE <br />THE NECESSARY WIRE SIZE ADJUSTMENT TO CONFORM WITH NEC ARTICLE #210-19. FOR <br />VOLTAGE LIMITS OF BRANCH CIRCUITS. <br />23. THE CONTRACTOR MUST INSURE THRU COORDINATION WITH STORE MANAGER AND <br />PROJECT REPRESENTATIVE THAT DURING CONSTRUCTION STAGES, PRIORITIES SHALL BE <br />ESTABLISHED TO KEEP THE STORE IN OPERATION - ESPECIALLY THE ECR/POS SYSTEM. <br />ANY ACTIVITIES AFFECTING SYSTEMS WHICH ARE VITAL TO THE CONTINUOUS OPERATION <br />OF THE STORE SHALL BE IMPLEMENTED DURING OFF -HOURS. CONSTRUCTION DURING <br />STORE OPERATIONS SHALL BE LIMITED TO MINIMAL INTERRUPTIONS DURING SLOW <br />BUSINESS HOURS. MINIMUM DISTANCE NECESSARY TO ALLOW PASSAGE OF POWER <br />POLES THRU CEILING. <br />24. IN GENERAL, MULTI -OUTLET PLUG-IN STRIPS AND/OR AUDIO/TV TRACKS SHALL BE <br />RELOCATED BY THIS CONTRACTOR FROM EXISTING DISPLAY FIXTURES AS IDENTIFIED <br />AND DIRECTED BY THE KMART PROJECT COORDINATOR. WHERE NEW ONES ARE <br />REQUIRED THIS CONTRACTOR SHALL FURNISH AND INSTALL NEW PLUG-IN STRIPS TO <br />MATCH EXISTING, PAINT RELOCATED PLUG-IN STRIPS "OFF WHITE" AS REQUIRED TO <br />MATCH NEW DISPLAY FIXTURES. SIMILAR TO WIREMOLD PLUGMOLD SERIES 2000 CAT. NO. <br />20GB612. ALL MULTIOUTLET STRIPS SHALL BE HARDWIRED. <br />25. SMALL APPLIANCES DISPLAY LUMINAIRES ARE DESIGNED TO BE MOUNTED UNDERNEATH <br />THE SHELVES WITH MATCHING MOUNTING CLIPS. LUMINAIRES AND MOUNTING CLIPS <br />WILL BE FURNISHED BY KMART FOR COMPLETE INSTALLATION BY ELECTRICAL <br />CONTRACTOR. EXACT MOUNTING METHOD SHALL BE AS DIRECTED BY THE KMART <br />PROJECT REPRESENTATIVE IN THE FIELD, DO NOT DRILL HOLES THROUGH THE <br />LUMINAIRES TO AVOID DAMAGE TO THE INTERNAL BALLASTS. <br />26. RELOCATION OF TELEPHONE, LAN DROPS, PA AND BA DEVICES AND WIRING WILL BE BY OTHERS. <br />27. PAINT ALL CONDUIT DROPS TO MATCH WALL COLOR. <br />28. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL WIRING AND CIRCUITS MATCHING RATING <br />AND POWER REQUIREMENTS OF SPECIFIC ELECTRIFIED STORE FIXTURES, DEVICES AND EQUIPMENT <br />NOT SHOWN ON THIS DRAWING BUT SHOWN AND INDICATED IN THE STORE PLANNING LAYOUT AS <br />BEING RELOCATED OR NEW AS VERIFIED AND DIRECTED BY THE KMART PROJECT COORDINATOR. <br />THESE EQUIPMENT SHALL INCLUDE BUT NOT BE LIMITED TO CHECKOUT POWER POLES COOLERS, <br />FREEZERS, PRICE SCANNERS, MOBILE CARTS, CASH REGISTERS, MULTIOUTLET STRIPS, <br />RECEPTACLES AND LUMINAIRES. <br />29. ELECTRICAL CONTRACTOR SHALL UTILIZE PREVIOUS CIRCUITS AND PANELS FOR ALL RELOCATED <br />EQUIPMENT SUCH AS COOLERS AND FREEZERS, ADJUST BRANCH FEEDER CONDUCTOR SIZES <br />INDICATED OR UTILIZE BOOSTER TRANSFORMERS TO LIMIT VOLTAGE DROPS TO A MAXIMUM OF 3 <br />EQUIPMENT. ALL RELOCATED AND NEW RECEPTACLES SHALL MATCH EXISTING CONFIGURATION <br />AND RATING OF EQUIPMENT. INPUT VOLTAGE TO FILM PROCESSORS UNDER FULL LOAD <br />CONDITIONS SHALL NOT FALL BELOW 200 VOLTS, <br />30. ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE THE POWER POLES SERVING <br />EXISTING CHECKOUTS BEING RELOCATED. POWER WIRING AND CIRCUITS SERVING THESE <br />EQUIPMENT SHALL BE EXTENDED AND RECONNECTED AT THEIR NEW LOCATIONS. REMOVAL <br />AND RELOCATION OF CABINET FIXTURES WILL BE BY OTHERS. SEE STORE PLANNING DRAWING <br />FOR EXACT LOCATIONS OF CHECKOUTS. <br />31. ELECTRICAL CONTRACTOR SHALL RELOCATE ANY EXISTING OVERHEAD LUMINAIRE(S) WHICH <br />MAY INTERFERE WITH THE RE -INSTALLATION OF POWER POLES SERVING RELOCATED CHECKOUT <br />FIXTURES. RELOCATION SHALL BE LIMITED TO THE BARE MINIMUM DISTANCE NECESSARY TO <br />ALLOW PASSAGE OF POWER POLES THRU CEILING. <br />32 PROVIDE TEN FEET OF MULTI -OUTLET STRIP PLUGMOLD 20613612 MOUNTED 18" AFF. IN SECURITY <br />OFFICE. PROVIDE 2#12, 1 #12 GND TO SPARE 20A BREAKER TO NEAREST 120V. GENERAL PURPOSE <br />PANEL. DISCONNECT AND REMOVE WALL -MOUNTED MAIN SWITCH FOR EXISTING PLUGMOLD IF <br />EXISTING. <br />33. NEW EXIT SIGN WALL MOUNTED ABOVE THE DOOR TO MATCH EXISTING CONNECT TO LOCKED -ON <br />EMERGENCY LIGHTING CIRCUIT. <br />34. EXTERIOR TO BE CONTROLLED BY PHOTOCELL AND A 7 DAY ASTRONOMICAL TIME SWITCH. <br />TIME SWITCH OVERRIDES PHOTOCELL TO TURN OFF SIGNS. COORDINAT WITH SIGNAGE <br />SUPPLIER FOR EXACT LOCATION OF OUTLET BOXES FOR EXTERIOR SIGNAGE. FINAL <br />CONNECTION OF SIGNS TO 120V BRANCH CIRCUITS BY SIGN CONTRACTOR. <br />�NO/ <br />C <br />F--� <br />F-� a C <br />W o <br />� CO <br />_ Ao <br />o�- <br />M Cd <br />Cn <br />W <br />coQ <br />O <br />cn <br />x <br />Q <br />ryN0 <br />0 <br />J <br />LL <br />O0 <br />LPL <br />J <br /><C <br />J_ <br />JN_ <br />ry <br />ZD <br />0 <br />m <br />Lu <br />J <br />Fj <br />J <br />Z <br />1 <br />CU <br />V <br />N <br />Q <br />J <br />0 <br />Z <br />= <br />L <br />E <br />_0 <br />vn <br />L0 <br />O <br />C17 <br />0') <br />i <br />rr <br />Q <br />Co <br />rr <br />L1 <br />Cy.) <br />Co <br />QO <br />0 <br />z <br />S <br />Lu <br />nr- <br />U <br />rr <br />� <br />Cn <br />J <br />Y z <br />W z Q <br />z <br />Q <br />Lu <br />rr <br />Q <br />Lu I_- <br />= 0-C <br />C" ) <br />U <br />m � L07 <br />Q co Lo <br />U <br />LL <br />Project Arch./ Engineer: <br />JOHN LINEGAR <br />Drawn: <br />DENNIS CARMICHAE <br />Checked: <br />BRAIN BILOTTA <br />Date: <br />JANUARY 17, 2007 <br />FLOOR PLAN <br />SCALE: 1/16"=1'-O" <br />Sheet No: <br />Em <br />