Laserfiche WebLink
a) <br />U <br />U) <br />2 <br />IL <br />N <br />N <br />O <br />O <br />O <br />N <br />N <br />T <br />C <br />O <br />Z <br />n <br />cm <br />O <br />O <br />O <br />rl- <br />00 <br />Ln <br />N <br />C <br />O <br />0 <br />U <br />7 <br />.O <br />O <br />d <br />O <br />LO <br />N <br />U) <br />N <br />L <br />T <br />a <br />a) <br />CD <br />aD <br />O <br />cm <br />m <br />2 <br />cn <br />-Z <br />w <br />I— <br />Q <br />d <br />Q <br />. p <br />ER <br />O <br />J <br />U_ <br />Z <br />U <br />d <br />POST TENSION SLAB (OPTION) <br />01 CONTRACTOR HAS THE OPTION OF PROVIDING A POST -TENSION SLAB SYSTEM IN LIEU OF THE MONOLITHIC <br />SLAB SYSTEM SHOWN IN THESE DRAWINGS. IF THE CONTRACTOR CHOOSES TO TAKE THIS OPTION, THE <br />CONTRACTOR MUST SUBMIT COMPLETE POST -TENSION DESIGN DRAWINGS WITH DETAILS, SIGNED AND <br />SEALED BY AN ENGINEER REGISTER IN THE STATE WHERE THE PROJECT IS LOCATED, TO THE ARCHITECT AND <br />STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. <br />02 PROVIDE ALL NECESSARY BAR SUPPORT AND TIES IN ACCORDANCE WITH THE LATEST A.C.I. DETAILING <br />MANUAL. <br />03 PROVIDE 3/4" COVER TOP AND BOTTOM FOR POST -TENSION CABLE AND 3/4" COVER FOR MILD STEEL <br />REINFORCEMENT. <br />04 MAXIMUM SLUMP OF CONCRETE SHALL BE 4" AND MINIMUM CONCRETE STRENGTH fc' = 4000 PSI IN SLABS AT 28 <br />DAYS. <br />05 ADD HOOK LENGTHS TO BARS SHOWN THUS: L <br />06 POST TENSIONING TENDONS SHALL BE 7 WIRE STRAND, ASTM A416 GRADE 270. <br />07 CALCIUM CHLORIDE SHALL NOT BE USED IN ANY POST -TENSION SLAB OR BEAM. <br />08 FREE MOVEMENT OF THE BEAMS IN THE FORM MUST BE INSURED DURING PRE -STRESSING <br />09 REINFORCING LENGTH MAY VARY BY A MAXIMUM OF 3 INCHES TO ELIMINATE WASTE. <br />10 HEIGHTS OF STRANDS ARE MEASURED FROM BOTTOM OF THE SLAB TO THE CENTERLINE OF STRAND, OR <br />CENTROID OF STRAND GROUP. <br />11 STRANDS MAY BE STRESSED WHEN CONCRETE ACHIEVES 75% OF THE REQUIRED 28 DAY STRENGTH. <br />12 THE POST -TENSION CONTRACTOR SHALL PREPARE SHOP DRAWINGS AND STRESSING CALCULATIONS, BOTH <br />CERTIFIED BY A PROFESSIONAL ENGINEER IN THE STATE OF THE PROJECT TO BE SUBMITTED TO THE <br />ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL, PRIOR TO CONSTRUCTION. NO <br />PLACEMENT OF TENDONS SHALL COMMENCE WITHOUT APPROVED DRAWINGS. REVIEW OF SHOP DRAWINGS <br />IS FOR GENERAL DETAIL AND ARRANGEMENT ONLY. CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR <br />DIMENSIONS AND FIT. THEIR APPROVAL BY THE STRUCTURAL ENGINEER AND ARCHITECT IS NOT TO BE <br />CONSTRUED AS A WAIVER OF CONSTRUCTION CONTRACT REQUIREMENTS OR RESPONSIBILITIES, UNLESS THE <br />CONTRACTOR HAS REQUESTED A DEVIATION IN WRITING. <br />13 SHOP DRAWINGS ARE TO INDICATE STRAND SPACING, PROFILE, CHAIR HEIGHTS AND SPACINGS, STRESSING <br />FORCES AND ANTICIPATED ELONGATION. <br />14 POST -TENSION CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER AND ARCHITECT THREE (3) <br />COPIES OF ELONGATIONS AND FORCES BOTH CALCULATED AND MEASURED, IMMEDIATELY AFTER WORK IS <br />COMPLETE. <br />15 THE FORCES SHOWN ON ANY DRAWING ARE THE EFFECTIVE FORCES AT ANY POINT ALONG THE STRAND LINE <br />AFTER ALL LOSSES HAVE OCCURRED. <br />16 ALL FORM WORK SHORING MUST BE LEFT IN PLACE UNTIL STRESSING IS COMPLETED, <br />17 A MINIMUM OF TWO STRANDS SHALL PASS THROUGH EACH COLUMN OR VERTICAL SUPPORT. <br />18 ALL POCKETS REQUIRED FOR ANCHORAGES SHALL BE ADEQUATELY REINFORCED NOT TO DECREASE THE <br />STRENGTH OF THE STRUCTURE. ALL POCKETS SHALL BE WATERPROOFED TO ELIMINATE WATER LEAKAGE <br />THROUGH THE POCKET. <br />19 TENDONS SHALL BE DRAPED TO A DOUBLE PARABOLIC PROFILE BETWEEN SUPPORTS AND SHALL CONFORM <br />TO THE CONTROL POINTS SHOWN IN THE TENDON OR GROUP OF TENDONS. LOW POINTS ARE AT MID SPAN <br />UNLESS OTHERWISE NOTED. ADEQUATE SUPPORT BARS AND CHAIRS SHALL BE FURNISHED TO ADEQUATELY <br />HOLD THE TENDONS DURING THE CONCRETE PLACEMENT. <br />20 IN ACCORDANCE WITH A.C.I., ALL CONCRETE SHALL BE PRE -STRESSED TO PROVIDE A MINIMUM AVERAGE <br />COMPRESSIVE STRESS OF 100 PSI ON GROSS CONCRETE AREA, USING EFFECTIVE PRE -STRESS AFTER <br />LOSSES. CONTRACTOR SHALL PROVIDE MINIMUM FORCE IN ALL CONCRETE WHETHER OR NOT SPECIFICALLY <br />IDENTIFIED ON DRAWINGS. <br />21 GENERAL CONTRACTOR WILL SUBMIT APPROVED POST -TENSION DRAWINGS AND CALCULATIONS TO THE <br />BUILDING DEPT. FOR THEIR REVIEW AND APPROVAL PRIOR TO FOUNDATION CONSTRUCTION. <br />FOUNDATION <br />01 FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF. SHOULD <br />CONDITIONS VARY FROM THE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF <br />WORK. <br />02 ALL FOOTINGS SHALL BE PLACED DIRECTLY ON VIRGIN SOIL, OR CERTIFIED COMPACTED FILL. <br />03 CONCRETE FOR FOUNDATIONS: <br />A 28 DAY COMPRESSIVE STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS: <br />FOOTINGS 3000 PSI <br />SLAB ON GRADE 3000 PSI <br />WALLS 3500 PSI <br />B MAXIMUM CONCRETE SLUMP SHALL BE 4". <br />C SLAB ON GRADE SHALL BE 5" THICK WITH WWF 6 x 6 -W1.4 x W1.4. SLAB SHALL BE FINISHED IN <br />ACCORDANCE WITH ACI STANDARD 302 FOR CLASS 2 FLOORS. IN LIEU OF WWF, SLAB ON GRADE MAY <br />CONSIST OF FIBER REINFORCED CONCRETE ACI 544.2R-89. <br />D ALL CONCRETE SHALL BE MIXED, TRANSPORTED AND PLACED IN ACCORDANCE WITH ACI STANDARDS <br />318, 304 AND 301. <br />E ALL REINFORCING BARS SHALL BE OF BILLET STEEL CONFORMING TO ASTM A615, GRADE 60. <br />F ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185. <br />G ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS AND FOOTINGS, <br />H REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER: <br />SLAB ON GRADE 1-1/2" <br />WALLS 2" <br />FOOTINGS 3" <br />1 GRADE BEAMS SHALL BE FORMED ON SIDES. <br />04 ALL FILL SHALL BE PLACED IN 8 INCH LOOSE LIFTS (MAXIMUM) COMPACTED WITH VIBRATORY ROLLERS. FILL <br />MATERIAL SHALL BE TESTED BY MODIFIED PROCTOR DENSITY METHOD (ASTM D1557) AND MUST QUALIFY AS <br />SELECT, WITH LESS THAN 10% PASSING THROUGH THE NO.200 SIEVE. SOIL SHALL BE PLACED WITH MOISTURE <br />CONTENT AND ENERGY TO PROVIDE 98% OF MAXIMUM DRY DENSITY BELOW SLABS ON GRADE, AND SOIL <br />SHALL BE COMPACTED TO 98% 12" AND 24" BELOW STRIP FOOTINGS AND COLUMN FOOTINGS, RESPECTIVELY. <br />IN PLACE DENSITY TESTS SHALL BE TAKEN FOR EACH 2,000 S.F. IN EACH LIFT. FOR ACCEPTANCE OF SOIL, <br />AVERAGE OF DENSITY TESTS MUST EXCEED THE SPECIFIED COMPACTION. NO TESTS SHALL BE PERMITTED <br />TO FALL BELOW 90% COMPACTION. <br />05 ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 2'-0" BELOW FINAL GRADE WHEN BEARING ON SOIL, <br />UNLESS NOTED OTHERWISE ON THE FOUNDATION DRAWINGS. <br />06 WHERE NECESSARY, FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 VERTICAL TO 2 <br />HORIZONTAL. <br />07 WHERE ROCK OUTCROPPINGS ARE ENCOUNTERED IN A BUILDING FOUNDATION BEARING ON SOIL, SUCH <br />OUTCROPPING OR INTERFERENCE SHALL BE REMOVED TO A DEPTH 12 INCHES BELOW BOTTOM OF FOOTING <br />AND REPLACED WITH CLEAN GRANULAR MATERIAL CONTAINING LESS THAN 5% SILT, COMPACTED TO 95% <br />DENSITY PER MODIFIED PROCTOR METHOD. MAINTAIN A MINIMUM COVER OF 1'-6" TO BOTTOM OF CONCRETE. <br />08 WHERE SOLID UNFRACTURED ROCK IS ENCOUNTERED FOR A WALL LENGTH OF AT LEAST 25 FEET, WALLS MAY <br />BE POURED WITHOUT FOOTINGS BY TRENCHING 6 INCHES INTO THE ROCK AND PINNING THE WALL TO ROCK <br />WITH #6 x T-0" LONG DOWELS AT 2'-8" ON CENTER, GROUTED INTO ROCK, EXTENDING V-6" INTO ROCK. NO <br />FROST PROVISIONS ARE REQUIRED FOR THIS DETAIL. PROVIDE CONTROL JOINT IN WALL AT ANY TRANSITION <br />BETWEEN ROCK BEARING AND SOIL BEARING CONDITIONS. <br />09 EXCAVATIONS SHALL BE DEWATERED TO A DEPTH OF AT LEAST 2 TO 3 FEET BELOW THE BOTTOM OF THE <br />EXCAVATIONS TO ALLOW INSTALLATION OF FOOTINGS IN DRY ATMOSPHERE. <br />10 DIFFERENTIAL BACKFILL AGAINST FOUNDATION WALLS SHALL NOT EXCEED FOUR FEET UNTIL TOP BRACING <br />OR FRAMEWORK HAS BEEN IN PLACE FOR A MINIMUM OF THREE DAYS. CANTILEVERED RETAINING WALLS MAY <br />BE BACK -FILLED WITHIN 14 DAYS OF CONCRETE PLACEMENT, BUT IN NO CASE SHALL DIFFERENTIAL OF <br />BACKFILL, BETWEEN OPPOSITE SIDES OF THE WALL, EXCEED THE FINAL DESIGN DIFFERENTIAL. <br />11 ALL BOTTOM OF FOOTING ELEVATIONS ARE SUBJECT TO CHANGE UPON INSPECTION OF SOIL CONDITION. <br />ELEVATION OF ADJACENT FOOTINGS SHALL VARY ON A SLOPE NOT STEEPER THAN ONE VERTICAL TO TWO <br />HORIZONTAL. <br />12 THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE BOTTOM OF FOOTING ELEVATION IS CHANGED AND <br />OBTAIN REVISED DESIGN OF THE FOUNDATION AND RETAINING WALLS AS REQUIRED. <br />13 A MINIMUM 6-MIL POLYETHYLENE VAPOR BARRIER BETWEEN THE BOTTOM OF THE FLOOR SLAB AND THE TOP <br />OF THE COMPACTED SUBGRADE SHALL BE INSTALLED. <br />GENERAL <br />01 THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL <br />CHAPTERS OF THE 2007 FLORIDA BUILDING CODE (FBC). ALL WORK SHALL BE PERFORMED IN ACCORDANCE <br />WITH THIS CODE AND ALL LOCAL REQUIREMENTS. <br />02 DESIGN LOADS: <br />A SEE DESIGN CRITERIA ON STRUCTURAL DRAWING S4.01. <br />B FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS. <br />C WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />D COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />E DESIGN ROOF SNOW LOAD: N/A <br />F SEISMIC: N/A <br />03 ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING <br />DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE ARCHITECT PRIOR TO <br />CONSTRUCTION OF WORK. <br />04 THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND VERIFY <br />ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION. NOTIFY THE <br />ARCHITECT / ENGINEER OF ANY DISCREPANCIES. <br />05 IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY <br />CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE <br />MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT / ENGINEER. <br />CONCRETE <br />01 PROVIDE STEEL TROWEL FINISH FOR ALL INTERIOR SLAB AREAS. PROVIDE BROOM FINISH FOR ALL EXTERIOR <br />SLAB AREAS U.N.O. ALL HANDICAPPED RAMPS SHALL BE BROOM FINISHED PERPENDICULAR TO THE SLOPE. <br />02 PROVIDE CONCRETE SLAB FOR AIR CONDITIONER COMPRESSOR AS REQUIRED BY EQUIPMENT <br />MANUFACTURER. COORDINATE PLACEMENT OF SLAB WITH FINISH GRADING AT COMPRESSOR LOCATION. <br />03 ALL SIDEWALKS & MECH. EQUIP. SLABS SHALL SLOPE AWAY FROM BUILDING. <br />SUBMITTALS <br />01 THE FOLLOWING ITEMS REQUIRE SUBMITTAL OF SHOP AND ERECTION DRAWINGS FOR REVIEW: (IF <br />APPLICABLE) <br />A REINFORCING STEEL FOR CAST -IN -PLACE CONCRETE <br />B STEEL JOISTS <br />C STEEL DECKING AND STUD LAYOUT <br />D STRUCTURAL STEEL <br />E STEEL STAIRS <br />F COMPOSITE DRAWINGS OF ALL SLAB PENETRATIONS <br />l ,s <br />02 THE FOLLOWING ITEMS REQUIRE SUBMITTAL OF SHOP AND ERECTION DRAWINGS AND STRUCTURAL <br />CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THIS <br />PROJECT: <br />A PRECAST CONCRETE - PLANK, WALL PANELS, ETC. 1, <br />B CURTAIN WALLS <br />C SKYLIGHTS <br />D SHORING AND RE -SHORING <br />E CONCRETE DESIGN MIXES <br />F TIMBER TRUSSES AND/OR WOOD I -JOISTS, STRUCTURAL AND TIMBER FABRICATIONS <br />G PRE -STRESSING TENDONS <br />_k <br />wren <br />III <br />=III=III �� <br />111==+ti/'�/ ENGINEERING <br />r11=III'` GROUP <br />FL CofA #7992 <br />5728 Major Blvd., Suite 603, Orlando, FL 32819 <br />Tel. (407) 354-5411 Fax (407) 354-3466 <br />Web Site: www.mgmclaren.com <br />R.F. Cleric FL PE #52514 <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orients avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone:407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Meetinghouse <br />at Zephyrh i I Is <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />1W09109 <br />N, Progress S <br />12/17109 <br />Bid Set <br />03/02/10 <br />Permit Set <br />............................................. . _................_ <br />0 SHEET REVISIONS: <br />I EDITED BY: <br />U <br />Z PROJECT NO. <br />General Notes - <br />Foundation <br />S3.00 <br />09-2587 <br />