Laserfiche WebLink
SUBMITTALS WOOD STRUCTURAL PANEL (PLYWOOD) GENERAL I <br />01. THE FOLLOWING ITEMS REQUIRE SUBMITTAL OF SHOP AND ERECTION DRAWINGS FOR REVIEW: (IF <br />APPLICABLE) <br />A. REINFORCING STEEL FOR CAST -IN -PLACE CONCRETE <br />B. STEEL JOISTS <br />C. STEEL DECKING AND STUD LAYOUT <br />D. STRUCTURALSTEEL <br />E. STEEL STAIRS <br />F. COMPOSITE DRAWINGS OF ALL SLAB PENETRATIONS <br />02. THE FOLLOWING ITEMS REQUIRE SUBMITTAL OF SHOP AND ERECTION DRAWINGS AND STRUCTURAL <br />CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THIS <br />PROJECT. <br />A. PRECAST CONCRETE - PLANK, WALL PANELS, ETC. <br />B. CURTAIN WALLS <br />C. SKYLIGHTS <br />D. SHORING AND RE -SHORING <br />E. CONCRETE DESIGN MIXES <br />F. TIMBER TRUSSES AND/OR WOOD I -JOISTS, STRUCTURAL AND TIMBER FABRICATIONS <br />G. PRE -STRESSING TENDONS <br />CONCRETE MASONRY UNITS (CMU) <br />01 ALL CONCRETE MASONRY UNITS SHALL BE HOLLOW LOAD BEARING UNITS CONFORMING TO ASTM C90, GRADE N-TYPE I <br />WITH ASSUMED DESIGN COMPRESSIVE STRENGTH fm=1500 PSI. UNITS MAY BE FABRICATED EITHER WITH NORMAL WEIGHT <br />AGGREGATE (C33) OR LIGHTWEIGHT AGGREGATE (C331). <br />02 ALL UNITS SHALL BE PLACED IN RUNNING BOND. <br />03 MORTAR SHALL BE TYPE M OR S. MORTAR SHALL MEET ASTM C270. <br />04 GROUT SHALL COMPLY WITH ASTM C476. SLUMP SHALL BE 8 TO 11 INCHES, STRENGTH SHALL BE EQUAL TO 2500 PSI. <br />05 STORE ALL UNITS OFF GROUND TO PREVENT CONTAMINATION. COVER MATERIALS TO PROTECT FROM THE ELEMENTS. <br />06 NO AIR -ENTRAINING ADMIXTURES OR ANTIFREEZE COMPOUNDS, SUCH AS CALCIUM CHLORIDE SHALL BE ADDED TO <br />MORTAR. <br />07 ALL WALLS OR PILASTERS SUPPORTING STEEL AT BEARING PLATES SHALL BE GROUTED SOLID FOR FOUR COURSES IN <br />DEPTH FOR A WIDTH OF 32". <br />08 DO NOT BACKFILL AGAINST FOUNDATION WALLS UNTIL MORTAR HAS ATTAINED MAXIMUM STRENGTH. WHERE BACKFILL IS <br />PLACED AGAINST FOUNDATION WALLS BEFORE FLOOR CONSTRUCTION IS IN PLACE, PROVIDE TEMPORARY BRACING. <br />09 THE FIRST BLOCK COURSE ON FOOTING SHALL BE FILLED SOLID WITH CONCRETE, UNLESS OTHERWISE NOTED ON <br />DRAWINGS. <br />10 VERTICAL CONTROL JOINTS SHALL BE PLACED SUCH THAT THE RATIO OF JOINT SPACING (L) DIVIDED BY WALL HEIGHT (H) <br />DOES NOT EXCEED 3.0. IN NO CASE SHALL SPACING EXCEED 50 FT. CONTROL JOINTS SHALL BE CONSTRUCTED USING SASH <br />BLOCKS AND DOOR-O-WAL PREFORMED REGULAR RAPID CONTROL JOINT (OR EQUAL OF EXTRUDED RUBBER.) WALL <br />REINFORCING SHALL BE DISCONTINUOUS AT JOINTS. VERTICAL JOINTS SHALL BE LOCATED AS FOLLOWS: <br />A CHANGES IN WALL HEIGHT OR THICKNESS. <br />B AT CONSTRUCTION JOINTS IN FOUNDATION, IN ROOF, AND IN FLOORS. <br />C AT CHASES AND RECESSES FOR PIPING, COLUMNS, FIXTURES, ETC. <br />D AT ABUTMENT OF WALL AND COLUMNS. <br />E AT RETURN ANGLES IN "L", "T" AND "U" SHAPED STRUCTURES. <br />F AT ONE OR BOTH SIDES OF WALL OPENING. <br />W <br />cu <br />U <br />0 <br />N <br />LO <br />0 <br />0 <br />0 <br />N <br />N <br />0 <br />0 <br />0 <br />1. PLYWOOD FOR SUBFLOOR (FLOOR SHEATHING) OVER SAWN LUMBER SHALL BE 5/8" C-D EXT., SPECIES <br />GROUP 3, APA IDENTIFICATION INDEX 32/16. INDEX STAMP SHALL BE VISIBLE ON ALL SHEETS. <br />2. PLYWOOD FOR SUBFLOOR (FLOOR SHEATHING OVER WOOD TRUSSES) SHALL BE 3/4" C-D EXT., SPECIES <br />GROUP 3, APA IDENTIFICATION INDEX 40/20, GLUED TO TOP OF TRUSS AND SCREWED TO TOP FLANGE AT <br />12" ON CENTER. <br />3. PLYWOOD FOR ROOF SHEATHING SHALL BE 5/8" APA RATED SHEATHING EXP. 1, APA IDENTIFICATION <br />INDEX 40/20, OR BETTER. <br />4. PLYWOOD ROOF SHEATHING SHALL BE NAILED TO TRUSSES AS PER ROOF ZONE FASTENING PLAN. <br />5. USE PLYCLIPS OR OTHER EDGE SUPPORTS FOR ALL PLYWOOD SHEATHING. <br />6. PLACE FACE GRAIN IN DIRECTION OF SPAN (TRANSVERSE TO JOIST OR TRUSS SPAN). <br />7. LEAVE 1/16" SPACE AT ALL PLYWOOD PANEL END JOINTS AND 1/8" SPACE AT ALL PANEL EDGE JOINTS. <br />GLUE LAMINATED TIMBER <br />1. ALL GLUED LAMINATED TIMBER SHALL CONFORM TO ANSI/AITC Al90.1 'STRUCTURAL GLUED LAMINATED <br />TIMBER. <br />2. ALL GLUED LAMINATED TIMBER SHALL BE FABRICATED OF EITHER: <br />A. VISUALLY GRADED SOUTHERN YELLOW PINE, COMBINATION OF 20E-V2 OR <br />B. VISUALLY GRADED DOUGLAS FIR, COMBINATION OF 20E-V4 WITH MIN, FB=2000 PSI, & E=1,600,000 PSI <br />3. ADHESIVE SHALL BE'WET USE' ADHESIVE IN ACCORDANCE WITH ASTM D2559. <br />4. ALL GLUED LAMINATED TIMBER UNITS SHALL BE ARCHITECTURAL APPEARANCE GRADE, IN ACCORDANCE <br />WITH AITC 110. <br />5. ALL GLUED LAMINATED TIMBER SHALL BE SHOP CUT FOR CONNECTIONS AND CONNECTING HARDWARE <br />INCLUDING DRILLING OF BOLT HOLES. <br />6. ALL GLUED LAMINATED TIMBER SHALL BE PROTECTED DURING TRANSIT, STORAGE AND ERECTION IN <br />ACCORDANCE WITH AITC 111. PROTECTION SHALL INCLUDE FACTORY APPLICATION OF END SEALERS <br />AND TRANSLUCENT PENETRATING SURFACE SEALER. MEMBERS SHALL BE INDIVIDUALLY WRAPPED FOR <br />SHIPMENT. <br />7. MANUFACTURER SHALL BE AN AITC LICENSED FIRM, QUALIFIED TO APPLY THE AITC 'QUALITY INSPECTED' <br />MARK. ALL GLUED LAMINATED UNITS SHALL BEAR THE'QUALITY INSPECTED' MARK ON A SURFACE WHICH <br />WILL NOT BE EXPOSED IN THE FINISHED STRUCTURE. <br />MICROLLAM(R) OR PARALL.AM(R) BEAMS <br />1. MICROLLAM(R) OR PARALLAM(R) BEAMS ARE INDICATED ON DRAWINGS AS: M.L. OR P.L. <br />2. MICROLLAM(R) BEAMS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: <br />E = 1.9X10^6PSI <br />FB = 2,600 PSI <br />FT = 1,555 PSI <br />FC = 750 PSI <br />FC, PARALLEL = 2,510 PSI <br />FV = 285 PSI <br />3. BEAMS MUST BE LATERALLY SUPPORTED AT TOP. <br />4. MINIMUM BEARING LENGTH SHALL BE MINIMUM OF 1-1/2" AT ENDS AND 31/2" AT INTERMEDIATE <br />SUPPORTS. <br />5. MULTIPLE MEMBERS SHALL BE FASTENED TOGETHER IN ACCORDANCE WITH MANUFACTURER'S <br />SPECIFICATIONS. <br />a PLYWOOD BOX BEAM <br />1. FABRICATION OF PLYWOOD BOX BEAMS SHALL BE IN ACCORDANCE WITH THE NATIONAL DESIGN <br />SPECIFICATION (NDS) 2005, THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION AND THE AMERICAN <br />PLYWOOD SPECIFICATIONS, AS SUMMARIZED BELOW. <br />2. THE BOX BEAMS DESCRIBED HERE ARE GRADE AS CLASS 2 BEAMS. THEY ARE INTENDED AS THOSE WITH <br />FLANGES OF STRESS -GRADE LUMBER. LUMBER FLANGES OF ONE OR MORE LAMINATIONS MUST BE <br />GLUED UNDER PLYWOOD OR TO LUMBER UNDER POSITIVE MECHANICAL PRESSURE OR WITH THE <br />PRESSURE APPLIED BY NAILS OR STAPLES. <br />3. THE BEAM CROSS SECTION SHALL BE EITHER TYPE A OR TYPE B. <br />A. TYPE A BEAMS CONSIST OF PLYWOOD WEBS ON BOTH SIDES OF LUMBER TOP AND BOTTOM FLANGES. <br />WEB MAY BE NAILED/GLUED. <br />B. TYPE B BEAMS ARE SIMILAR TO TYPE A EXCEPT THAT THEY INCLUDE A PLYWOOD SHIM BETWEEN THE <br />LUMBER TOP AND BOTTOM FLANGES. <br />4. INTERMEDIATE STIFFENERS SHALL BE PLACED NO MORE THAN 48" ON CENTER AND SHALL BE THE SAME <br />WIDTH AS THE LUMBER FLANGED AT THAT SECTION. BEARING STIFFENERS AT ENDS OF BEAMS SHALL BE <br />THE SAME WIDTH AS THE LUMBER FLANGE AT THAT SECTION AND DOUBLED UP. <br />5. THE ADHESIVE USED FOR CONSTRUCTION OF THE PLYWOOD BOX BEAMS SHALL BE A RESORCINOL BASE <br />ADHESIVE, AND SHALL COMPLY WITH THE REQUIREMENTS OF VOLUNTARY PRODUCT STANDARD PS56-73, <br />'STRUCTURAL GLUED LAMINATED TIMBER. <br />01. THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE <br />STRUCTURAL CHAPTERS OF THE 2007 FLORIDA BUILDING CODE (FBC). <br />ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THIS CODE AND ALL LOCAL REQUIREMENTS. <br />02. DESIGN LOADS: <br />A. SEE DESIGN CRITERIA ON STRUCTURAL DRAWING S4.01. <br />B. FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS. <br />C. WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />D. COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL <br />DRAWINGS. <br />E. DESIGN ROOF SNOW LOAD: N/A <br />F. SEISMIC: N/A <br />03. ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING <br />DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE STRUCTURAL <br />ENGINEER PRIOR TO CONSTRUCTION OF WORK. <br />04. THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND <br />VERIFY ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION. NOTIFY <br />THE ARCHITECT / ENGINEER OF ANY DISCREPANCIES. <br />05. IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY <br />CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE <br />SHALL BE MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT / ENGINEER. <br />0 LUMBER <br />1. ALL NEW LUMBER SHALL BE VISUALLY GRADED LUMBER, SOUTHERN YELLOW PINE NO.2 OR BETTER <br />WITH MAXIMUM MOISTURE CONTENT OF 19%AND MINIMUM E=1,600,000 PSI IN ACCORDANCE WITH THE <br />NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION. <br />2. ALL LUMBER SHALL BEAR VISIBLE GRADE STAMPING. <br />3. ALL JOISTS BEARING ON MASONRY SHALL BE FIRE -CUT WITH MINIMUM BEARING LENGTH OF FOUR <br />INCHES. <br />4. EXCEPT AS UPGRADED ON PLANS OR DETAILS, ALL LUMBER SHALL BE NAILED IN ACCORDANCE WITH THE <br />NAILING SCHEDULE IN TABLE 2304.9-1 OF CHAPTER 23 OF THE 2007 FBC. <br />5. JOISTS SHALL BE FASTENED TO STEEL GIRDERS BY EITHER OF TWO ACCEPTABLE METHODS AS FOLLOWS <br />EXCEPT AS NOTED AT'TIMBER CONNECTIONS' BELOW: <br />A. A CONTINUOUS 2 x 6 NAILER PLATE SHALL BE BOLTED TO THE TOP FLANGE OF STEEL WITH 1/2 DIA. <br />STAINLESS STEEL BOLTS AT 4'-0" ON CENTER, ON ALTERNATE SIDES OF WEB. JOIST SHALL BE <br />TOENAILED TO PLATE WITH 3 8d NAILS PER JOIST. JOISTS FRAMING FROM OPPOSITE SIDES SHALL <br />LAP AT LEAST SIX INCHES, AND BE SPIKED TOGETHER AND BLOCKED. <br />B. A CONTINUOUS 2 x 4 NAILER PLATE SHALL BE BOLTED ABOVE THE BOTTOM FLANGE OF STEEL MEMBER <br />WITH 1/2 INCH DIAM. BOLTS AT 4'-0" ON CENTER. JOISTS SHALL BE NOTCHED ON TOP TO PROVIDE <br />CLEARANCE OF TOP FLANGE AND TO PROVIDE A SPACE OF AT LEAST 3/4" BETWEEN STEEL AND <br />SUBFLOOR. MAXIMUM DEPTH OF NOTCH SHALL BE 1/4 THE DEPTH OF JOIST. 20 GAGE METAL TIE OR <br />WOOD SCAB SHALL BE USED TO FASTEN OPPOSITE JOISTS TO ON ANOTHER. <br />TRUSSES <br />1. SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL OF ALL WOOD TRUSSES <br />2. SHOP DRAWINGS SHALL SHOW CHORD AND WEB SIZES, STRENGTHS, STIFFENERS (AS REQUIRED), <br />BEARING DETAILS, BRIDGING, BRACING, ERECTION NOTES AND DESIGN CALCULATIONS. TRUSSES SHALL <br />BE DESIGNED TO MEET THE DESIGN LOADS SHOWN ON THE STRUCTURAL NOTES AND PLANS. MAXIMUM <br />LIVE LOAD DEFLECTION SHALL BE LESS THAN 1/240 OF THE SPAN. MAXIMUM DEFLECTION UNDER FULL <br />DESIGN LOAD SHALL BE LIMITED TO 1/180 OF THE SPAN. <br />3. ALL SHOP DRAWINGS, ERECTION DRAWINGS AND CALCULATIONS SHALL BEAR THE SEAL AND SIGNATURE <br />OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF THIS PROJECT. <br />4. LATERAL BRACING OF WEB MEMBERS SHALL INCLUDE A DIAGONAL BRACE (2" THICK NOMINAL) AT <br />SPACING NOT TO EXCEED 20 FEET. ALL END BAYS SHALL BE DIAGONALLY BRACED. <br />5. BOTTOM CHORDS OF WOOD TRUSSES SHALL BE CONTINUALLY BRACED AT A SPACING NOT TO EXCEED <br />10 FEET, LOCATED AT OR NEAR A PANEL POINT. DIAGONAL BRIDGING SHALL BE INSTALLED AT END BAYS <br />AND IN INTERMEDIATE BAYS AT 20 FEET SPACING. <br />6. THE TRUSS ERECTOR IS RESPONSIBLE FOR PROPER TRUSS HANDLING AND FOR TEMPORARY BRACING. <br />ERECTION BRACING SHALL BE APPLIED AS EACH TRUSS IS PLACED IN POSITION. CARE MUST BE TAKEN <br />TO STABILIZE THE FIRST TRUSS AND DIAGONAL BRACING IS NECESSARY TO AVOID PROGRESSIVE <br />COLLAPSE. <br />aIII=III ,McLsk!en <br />q=III= 0%~ NEERING <br />11011 ft-on GROUP <br />FL CofA #7992 <br />5728 Major Blvd., Suite 603, Orlando, FL 32819 <br />Tel. (407) 354-5411 Fax (407) 354-3466 <br />Web Site: www.mgmclaren.com <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Meetinghouse <br />at Zephyrhills <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />0 <br />0 <br />0 <br />U <br />0 <br />U <br />0 <br />a <br />0 <br />C <br />Q <br />11/25109, ._ <br />` ..._Progress Set..._.... <br />12/09109 <br />60%u Progrq Sot <br />12/17/09 <br />Bid Set <br />03102110 <br />.......................:.:......................................... <br />Permit Set <br />............ _................ <br />Q SHEET REVISIONS: <br />General Notes - <br />Framing <br />............ ............... <br />.................._ .._... __... <br />S4.00 <br />�'!'-" <br />FR.F. Gieck FL PE #52514 <br />