My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Grand Reserve Apt
Zephyrhills
>
Building Department
>
Building Plans
>
Grand Reserve Apt
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:13:04 PM
Creation date
2/18/2025 4:07:16 PM
Metadata
Fields
Template:
Building Plans
Contractor
First Florida LLC
Building Plans - Permit #
10902-10905
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
= BUILDING TYPE: I(C.C.) ATTIC SPACE: A 111111110BUILDING TYPE: I(C.C.) ATTIC SPACE: B 0 BUILDING TYPE: I(C.C.) ATTIC SPACE: C a BUILDING TYPE: I(C.C.) ATTIC SPACE: D <br />SHEET NOTES <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />7256 <br />SF <br />NFA reqd (Attic Area / 150): <br />48.4 <br />SF <br />Total reqd ventilation area in SI (Net Free Area X 144): <br />6970 <br />SI <br />Upper portion regd (Total Reqd Vent Area X 50%): <br />3485 <br />SI <br />Lower portion reqd (Total Reqd Vent Area - Upper Portion): <br />3485 <br />SI <br />PROVIDED NFA VENTILATION - UPPER <br />( 0) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />0 <br />SI <br />- (1 � 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />3570 <br />SI <br />' Total Provided: <br />3570 <br />SI <br />PROVIDED NFA VENTILATION - LOWER <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Area of soffit: <br />256 <br />LF <br />NFA of soffit material per LF: <br />5 <br />SI <br />Total NFA of soffit material used: <br />1280 <br />SI <br />ADDITIONAL VENTILATION <br />MFR: Master EAC Model:l6"x8" Rectangular Vent <br />Number of vents to be used <br />34 Vents <br />NFA of additional soffit vents(ea): <br />65 <br />SI <br />Total NFA of additional soffit material used: <br />2210 <br />SI <br />Total provided: 3490 SI <br />rn <br />a; <br />0 <br />a <br />M <br />M <br />0 <br />M <br />d <br />CU <br />0 <br />0 <br />N <br />N <br />M <br />C <br />0 <br />a <br />0 <br />a <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />272 SF <br />NFA reqd (Attic Area / 150): <br />1.8 SF <br />Total reqd ventilation area in SI (Net Free Area X 144): <br />260 SI <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />130 SI <br />Lower portion reqd (Total Reqd Vent Area - Upper Portion): <br />130 SI <br />PROVIDED NFA VENTILATION - UPPER <br />( 1) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />138 SI <br />( 0) 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />0 SI <br />Total Provided: <br />138 SI <br />PROVIDED NFA VENTILATION - LOWER <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Total soffit material to be used: <br />66 LF <br />NFA of soffit material per LF: <br />5 / LF <br />Total provided: <br />330 SI <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />292 SF <br />NFA reqd (Attic Area / 150): <br />1.9 SF <br />Total reqd ventilation area in SI (Net Free Area X 144): <br />274 SI <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />137 SI <br />Lower portion reqd (Total Reqd Vent Area - Upper Portion): <br />137 SI <br />PROVIDED NFA VENTILATION - UPPER <br />(2) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />276 SI <br />( 0) 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />0 SI <br />Total Provided: <br />138 SI <br />PROVIDED NFA VENTILATION - LOWER <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Total soffit material to be used: 37 LF <br />NFA of soffit material per LF: 5 / LF <br />Total provided: 185 SI <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />106 SF <br />NFA reqd (Attic Area / 150): <br />.7 SF <br />Total reqd ventilation area in SI (Net Free Area X 144): <br />100 Si <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />50 Si <br />Lower portion reqd (Total Reqd Vent Area - Upper Portion): <br />50 SI <br />PROVIDED NFA VENTILATION - UPPER <br />(1) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />138 SI <br />( 0) 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />0 Si <br />Total Provided: <br />138 SI <br />PROVIDED NFA VENTILATION - LOWER <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Total soffit material to be used: 10 LF <br />NFA of soffit material per LF: 5 / LF <br />Total provided: 50 SI <br />AREA <br />"D" <br />„B" <br />Draft Barrier Area Diagram <br />Square Footages of Individual Areas Shown <br />N.T.S. <br />A REFER TO SHEETS S4.02 FOR SHEAR WALL HOLD <br />DOWN DETAILS. <br />B REFER TO SHEET S4.00 FOR FRAMING GENERAL <br />NOTES <br />C SEE SHEET S4.02 FOR HEADER & BEAM SCHEDULE & <br />SUPPORTS <br />D UNIT NAMES REFLECT UNITS BELOW FRAMING <br />MEMBERS <br />KEY NOTES <br />01 DRAFTSTOPPING, TYP., DRAFTSTOPPING SHALL <br />COMPLY WITH FBC 717.3 AND FBC 717.4 REFER TO <br />WALL SECTIONS FOR DETAILS <br />02 22061-HR FIRE RATED ATTIC ACCESS W/ LOCK. <br />CONTRACTOR TO COORDINATE LOCATION <br />03 OFF RIDGE VENT W/ INSECT SCREEN AS LISTED TO <br />MEET CODE <br />04 22"x36" SELF CLOSING DRAFT STOP ACCESS DOORS <br />05 PREFAB WD ROOF TRUSSES AT MAX 24" OC ROOF <br />PITCH TO BE 5:12 UNO, W/ 16" OVERHANG LINO <br />06 20" DEEP PREFAB WD FLOOR TRUSS AT 24" OC TYP <br />AT UNITS, LINO <br />07 17" DEEP PREFAB WD TRUSS AT 24" OC TYP AT <br />BREEZEWAY <br />08 PREFAB WOOD BALCONY TRUSS WITH SLOPED TOP <br />CHORD AT 24" OC <br />09 FLOOR TRUSS TO HAVE ADDITIONAL DIAGONAL <br />BRACES DUE TO SHEAR WALLS <br />10 ALUM GUTTERS & DOWNSPOUTS, TYP. <br />11 SW-1 SHALL STOP V-0" BEFORE ELECTRICAL METER <br />CENTER AND BEGIN V-0" AFTER METER CENTER. <br />PROVIDE 2X6 WALL AT METER CENTER. CONTRACTOR <br />TO COORDINATE LOCATIONS AND LENGTH OF METER <br />CENTER WALL <br />12(J3)'2X4'# 25.YP. STUDS GNDDER-EACH S(DE"OF-BE <br />IN BREEZEWAY WALL. NAIL WITH 16d @ 12" OC EACH <br />1 LY P OV DE CO TI U US Y TO F U D 10 . <br />13 STEP UP IN ROOF TRUSS; REFER TO RCP AND <br />SECTIONS <br />14 ALL CORNERS MARKED (4 LOCATIONS): USE (2) 2X6 <br />S.Y.P. #2 @ 16" O.C. (FASTEN PLIES WITH 10d @ 12" <br />O.C. STAGGERED) FOR A DISTANCE OF T-0" ALONG <br />EACH INTERSECTING WALL OR UNTIL WALL ENDS <br />15 ALIGN RIDGE WITH CORNER OF UNIT WALL <br />16 20" DEEP PREFAB WD FLR .TRUSS AT 16" OC <br />17 CRICKET: COVER CRICKET FRAMING WITH <br />SELF -ADHERING MEMBRANE AND SHEET METAL. <br />PROVIDE METAL VALLEY FLASHINGS, SEE DETAILS <br />18 ROOF FRAMING: CONVENTIONAL FRAMED JOISTS @ <br />16" O.C. <br />0 LEGEND <br />WALLS BELOW <br />INT. LOAD BRG. WALLS <br />SW-1 SHEAR WALLS, HOLD DOWNS = <br />— D CONT. DRAFTSTOPPING <br />HEADER OR BEAM <br />- - PREFAB. WOOD TRUSS <br />,max 1 RATED ATTIC ACCESS DOOR <br />® 4' TAMCO OFF -RIDGE VENT <br />© 6' TAMCO OFF -RIDGE VENT <br />0 COLUMN REF. PER S4.02 <br />KEY PLAN <br />-MC <br />NRPW ren <br />_ a <br />�I=III= -w-W ENGINEERING <br />'11=11_I „00 GROUP <br />FL CofA #7992 <br />5728 Major Blvd., Suite 603, Orlando, FL 32819 <br />Tel. (407) 354-5411 Fax (407) 354-3466 <br />Web Site: www.mgmclaren.com <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Meetinghouse <br />at Zephyrhills <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />i <br />I <br />SET DISTRIBUTIONS: <br />lei <br />SHEET REVISIONS: <br />nation <br />EDITED BY: JD <br />PROJECT NO. 09-2587 <br />Partial Second Floor Framing Plan & Roof Framing Plan- Building Type I <br />1 /8"=1'-0" <br />F. Oleck. FL PE #52514 <br />S4.11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.