'llll. I I I 1111 M I <br />0 GYPSUM BOARD 0 GENERAL NOTES <br />a� <br />cc <br />U <br />W <br />Q <br />00 <br />N <br />L0 <br />77 <br />co <br />0 <br />0 <br />N <br />e M <br />N <br />0 <br />0 <br />Z <br />Q <br />U <br />01, ALL INTERIOR NON -RATED WALL CONSTRUCTION TO HAVE 1/2" REGULAR GYPSUM BOARD, UNO <br />02. ALL INTERIOR FRAMED FIRE -RATED WALL CONSTRUCTION TO HAVE 5/8" FIRE -RATED GYPSUM BOARD, UNO <br />03. GYPSUM BOARD INSTALLATION SHALL BE IN CONFORMANCE WITH THE GYPSUM ASSOCIATIONS <br />RECOMMENDED PRACTICES FOR THICKNESS, ATTACHMENT, TAPING, FINISHING AND STUD SPACING. <br />04. GYPSUM BOARD USED IN A FIRE RATED ASSEMBLY SHALL CONFORM EXACTLY TO THE REQUIREMENTS OF <br />THE ASSEMBLY LISTED. <br />05. PROVIDE WATER RESISTANT TILE BACKER BOARD BEHIND ALL CERAMIC TILE IN TUBS AND SHOWERS. SEE <br />DETAILS. <br />WINDOWS & DOORS <br />1. ALL EXTERIOR WINDOWS AND DOORS SHALL BE SEALED AND WEATHER STRIPPED. WINDOW UNITS SHALL <br />DISPLAY LABELS SHOWING COMPLIANCE WITH THE STATE ENERGY CODE. <br />2. HINGES ON EXTERIOR OUT -SWINGING DOORS SHALL HAVE NON -REMOVABLE PINS AND NON -EXPOSED <br />SCREWS. <br />3. GLASS AT EXTERIOR DOORS SHALL COMPLY WITH ANSI 297A . <br />4. VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATING <br />DEVICE OF LOOSE AND SWING DOORS SHALL COMPLY WITH THE ANSI 297.1. <br />5. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANELS. UNIT <br />ENTRY DOORS SHALL HAVE AN ADDITIONAL PEEPHOLE @ 4'-10" AFF. <br />6. INDIVIDUAL GLAZED AREAS, INCLUDING GLASS MIRRORS, IN HAZARDOUS LOCATIONS AS DEFINED BY THE <br />BUILDING CODE SHALL HAVE SAFETY GLAZING MATERIAL IN COMPLIANCE WITH THE BUILDING CODE. <br />7. HARDWARE: ALL EQUIPMENT AND HARDWARE, WHERE APPLICABLE, SHALL MEET ALL FEDERAL, STATE, <br />AND LOCAL GUIDELINES FOR HANDICAP ACCESSIBILITY. FORCE REQUIRED TO OPERATE ALL EQUIPMENT <br />SHALL BE NO GREATER THAN 5 LBS. ALL DOORS IN UNITS AND PUBLIC AREAS TO HAVE LEVER -ACTION <br />HANDLES. <br />8. EMERGENCY ESCAPE AND RESCUE OPENING: EACH SLEEPING ROOM SHALL CONTAIN AT LEAST ONE <br />OPENING WINDOW OR DOOR THAT MUST BE OPERABLE FROM INSIDE WITHOUT THE USE OF TOOLS. THE <br />OPENING MUST BE ACCESSIBLE TO FIRE DEPARTMENT RESCUE APPARATUS OR BE WITHIN 20 FT. OF <br />GRADE. MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES AND MINIMUM NET CLEAR OPENING <br />HEIGHT SHALL BE 24 INCHES. MINIMUM NET CLEAR OPENING AREA SHALL BE 5.7 SQ. FT. AND MAXIMUM SILL <br />HEIGHT SHALL BE 44 INCHES ABOVE FINISHED FLOOR. <br />9. ALL WINDOWS SHALL BEAR THE APPROVED LABEL WITH CORRECT PRESSURES LISTED, AND BEAR A WDMA <br />OR OTHER APPROVED LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND <br />APPROVED PRODUCT EVALUATION ENTITY TO INDICATE COMPLIANCE WITH THE REQUIREMENT OF <br />AAMA/WOMA 101/I.S.2/NAFS. <br />10. ENERGY STAR RATING IS RtQUIRED FOR ALL WINDOWS IN EACH UNIT. <br />FIRE EXTINGUISHER <br />01. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EACH BUILDING AS REQUIRED AND SPECIFIED IN <br />NFPA 10, CHAPTER 3. PORTABLE FIRE EXTINGUISHER SHALL BE INSTALLED IN LOCATIONS INDICATED ON <br />THE DRAWINGS OR AT A MINIMUM OF (1) FIRE EXTINGUISHER PER BREEZEWAY, CORRIDOR, OR OVERALL <br />GENERAL BUILDING AREA. FIRE EXTINGUISHERS SHALL BE LOCATED (1) PER FLOOR, WITH A MAXIMUM <br />TRAVEL DISTANCE OF 75 FEET TO THE EXTINGUISHER OR AS REQUIRED BY LOCAL AUTHORITIES HAVING <br />JURISDICTION. EACH EXTINGUISHER SHOULD HAVE A MINIMUM RATING OF 2A:10-B:C, LINO <br />02. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EACH INDIVIDUAL RESIDENTIAL DWELLING UNIT AS <br />RECOMMENDED BY NFPA 10, ANNEX F AND INSTALLED AS INDICATED ON THE DRAWINGS OR AT A MINIMUM <br />OF (1) FIRE EXTINGUISHER PER FLOOR LEVEL OF A LIVING UNIT WITH A MAXIMUM TRAVEL DISTANCE OF 40 <br />FEET TO THE EXTINGUISHER OR AS REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION. EACH <br />EXTINGUISHER SHOULD HAVE A MINIMUM RATING OF 2A:10-B:C, LINO <br />PAINT <br />01. SEE INTERIOR FINISH SCHEDULE FOR PAINTING. REFER TO INTERIOR DESIGN DRAWINGS FOR PAINT SPEC. <br />AND COLORS. <br />02, ALL EXTERIOR VENTS AND EQUIPMENT THAT ARE VISIBLE ON EXTERIOR OF BUILDING SHALL BE PAINTED A <br />COLOR TO MATCH THE ADJACENT SURFACE, UNO <br />03. ALL COLOR TRANSITIONS SHALL BE ON THE INSIDE CORNERS, UNLESS OTHERWISE SPECIFIED IN COLOR <br />ELEVATIONS. <br />04. CONTACT THE OWNER OR ARCHITECT IF THERE ARE ANY QUESTIONS PRIOR TO PAINTING <br />05. LOW VOC PAINT (LESS THAN 50 GRAMS PER GALLON) IN ALL UNITS & INTERIOR COMMON AREAS <br />FLOOR COVERING <br />01. SEE INTERIOR FINISH SCHEDULE FOR FLOOR FINISHES. <br />02. ALL INTERIOR FLOOR FINISHES SHALL NOT BE LESS THAN CLASS II PER NFPA 253. <br />03. CARPET & RUG INSTITUTE GREEN LABEL CERITIFIED CARPET & PAD FOR ALL CARPETING PROVIDED. <br />■ SHELVING <br />1. ALL SHELVING TO BE VINYL COATED WIRE SHELVING, UNO <br />2. PROVIDE 12" DEEP ADJUSTABLE SHELVING W/ HANGING BAR AT BEDROOM CLOSETS, (5)16" DEEP SHELVES <br />IN PANTRY AND LINEN, AND (1)18" DEEP SHELF OVER WASHER AND DRYER, UNO <br />a CABINETS <br />01. BATHROOM CABINETS. ALL VANITY CABINETS SHALL BE 21" DEEP WITH 22" TOPS, UNO <br />02. KITCHEN CABINETS TO BE 24" DEEP WITH 25" TOPS, UNO <br />03. G.C. TO FIELD VERIFY FINISH TO FINISH DIMENSIONS PRIOR TO FABRICATION OF CABINETS. <br />04. FINISH ALL EXPOSED CABINET ENDS. <br />APPLIANCES <br />01. ENERGY STAR RATING REQUIRED FOR ALL REFRIGERATORS, DISHWASHERS AND WASHING MACHINES <br />PROVIDED. <br />01. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY <br />ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO <br />PROCEEDING WITH THE WORK. <br />02. DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND <br />IDENTIFICATION OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS <br />REGARDING EXACT REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF <br />WORK, AND CLASSIFICATIONS. <br />03. ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK <br />ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A <br />REVIEW OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. <br />04. DO NOT SCALE DRAWINGS. USE ONLY PRINTED DIMENSIONS. <br />05. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING <br />TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO <br />PROCEEDING WITH THE PROJECT. <br />06. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION <br />MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS <br />AND PROGRAMS, AND FOR COORDINATING ALL PORTIONS OF THE WORK. <br />07. ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT <br />THE NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE <br />NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY <br />THE OWNER. <br />08. DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, <br />OR ROUGH OPENING AT STUD WALLS. <br />09. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND <br />DATA TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY <br />PRODUCT SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT <br />ORIGINALLY SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE <br />NEW PRODUCT DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED <br />PRODUCT APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT. <br />10. ANY ERRORS, OMISSIONS OR INCONSISTENCIES DISCOVERED IN THE DOCUMENTS, OR ANY VARIATION OR <br />AMBIGUITIES BETWEEN THESE DRAWINGS AND ACTUAL SITE AND CONSTRUCTION CONDITIONS AND/OR <br />REQUIREMENTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IF A DISCREPANCY IS FOUND <br />IN THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING. <br />SITE WORK <br />01. SOIL BEARING VALUES. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR <br />ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. <br />FOUNDATIONS AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED <br />NON -EXPANSIVE SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING <br />LOADS, AND COMPARE WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE <br />OBSERVATIONS SHOW THAT FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL B <br />CONTACTED IMMEDIATELY FOR REVISED DESIGNS. <br />02. THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: <br />SITE UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR <br />REQUIRED AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, <br />ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY <br />WITH ALL UTILITY COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY <br />COMPANIES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY <br />COMPANY. <br />03. REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED <br />GRADES, FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC. <br />04. REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL <br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT <br />FIXTURES, ETC. <br />05. CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING <br />SHALL NOT BE LESS THAN 6 INCHES, LINO <br />TERMITE PROTECTION <br />01. ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION PROTECTION AGAINST SUBTERRANEAN TERMITES <br />APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN V-0" OF THE PRIMARY STRUCTURE SIDE <br />WALLS AS REQUIRED BY THE APPLICABLE BUILDING CODE. <br />02. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE AND INSTALL TERMITE PROTECTION AS REQUIRED BY ALL <br />APPLICABLE CODES AND PER MANUFACTURER'S RECOMMENDATIONS. <br />03. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE <br />WATER HEATER OR ELECTRICAL PANEL. <br />04. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST V-0" AWAY FROM BUILDING SIDE <br />WALLS. <br />0 <br />C <br />0 <br />.y <br />N <br />m <br />L• <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orients avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Meetinghouse <br />at Zephyrhills <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />SET DISTRIBUTIONS: <br />11/25109_._._ <br />12/09/09 <br />12117109_.___. <br />03I02110__... <br />..__._......._.._.- ......................._................__........._.._.....__...._._.._._.......__....._._... <br />Q SHEET REVISIONS: <br />EDITED BY: <br />PROJECT NO. <br />General Notes <br />Al .03 <br />JT <br />09-2587 <br />