CLUBHOUSE CODE COMPLIANCE PROJECT INFORMATION UNIT AREA TABLE BUILDING UNIT DIAGRAMS
<br />0
<br />0
<br />N
<br />00
<br />0
<br />L0
<br />0
<br />a�
<br />0
<br />a -
<br />OCCUPANCY TYPE A-3 ASSEMBLY
<br />(2) 4-STORY WOOD FRAME APARTMENT BUILDINGS W/ LOAD BEARING EXT. WALLS
<br />CONSTRUCTION TYPE TYPE V-B, NON-SPRINKLERED
<br />(1)1-STORY WOOD FRAME CLUBHOUSE BUILDING W/ LOAD BEARING EXT. WALLS
<br />(1) CMU TRASH DU'MPSTER ENCLOSURE
<br />AREA & HEIGHT LIMITATION (FBC-B TABLE 503)
<br />REQUIRED/ALLOWED
<br />PROPOSED
<br />MAX HEIGHT
<br />40'
<br />31'-2"
<br />■ GOVERNING BODIES
<br />MAX NUMBER OF STORIES
<br />2 STORIES
<br />1 STORIES
<br />MAXIMUM AREA PER FLOOR
<br />6,000 SF
<br />5,250 SF
<br />CITY OF ZEPHYRHfLLS
<br />53335 8TH ST
<br />FIRE PROTECTION (FBC-B TABLE 601 & 602):
<br />ZEPHYRHILLS, FL 33542
<br />STRUCTURAL FRAME
<br />0 HR
<br />0 HR
<br />PHONE (813) 780-0020
<br />EXTERIOR BEARING WALLS
<br />0 HR
<br />0 HR
<br />INTERIOR BEARING WALLS
<br />0 HR
<br />0 HR
<br />BUILDING CODES
<br />INTERIOR NON -BEARING WALLS
<br />0 HR
<br />0 HR
<br />FLORIDA BUILDING CODE, BUILDING (FBC-B) 2010 EDITION
<br />EXTERIOR NON -BEARING WALLS
<br />0 HR
<br />0 HR
<br />FLORIDA BUILDING CODE, ACCESSIBILITY (FBC-A) 2012 EDITION
<br />FLOOR CONSTRUCTION
<br />0 HR
<br />0 HR
<br />FLORIDA BUILDING CODE, MECHANICAL (FBC-M) 2010 EDITION
<br />ROOF CONSTRUCTION
<br />0 HR
<br />0 HR
<br />FLORIDA BUILDING CODE, ENERGY CONSERVATION (FBC-EC) 2010 EDITION
<br />FLORIDA BUILDING CODE FUEL GAS (FBC-FG) 2010 EDITION
<br />Unit Type
<br />Unit Name
<br />Unit Areas in SF
<br />Total Unit Area
<br />in SF
<br />Unit Total by
<br />Name
<br />Unit Total by
<br />Type
<br />Unit Type
<br />Percentages
<br />A/C Area
<br />Non -A/C Area
<br />1 Bed / 1 Bath
<br />Al
<br />735
<br />0
<br />735
<br />7
<br />16
<br />16.67%
<br />1 Bed / 1 Bath
<br />A2 UFAS
<br />735
<br />0
<br />735
<br />1
<br />1 Bed / 1 Bath
<br />A3
<br />836
<br />56
<br />892
<br />8
<br />2 Bed / 2 Bath
<br />131
<br />1066
<br />0
<br />1066
<br />23
<br />60
<br />62.50%
<br />2 Bed / 2 Bath
<br />B2
<br />1066
<br />60
<br />1126
<br />19
<br />2 Bed / 2 Bath
<br />B3
<br />1102
<br />0
<br />1102
<br />15
<br />2 Bed / 2 Bath
<br />B4 UFAS
<br />1066
<br />0
<br />1066
<br />1
<br />2 Bed / 2Bath
<br />B5 UFAS
<br />1066
<br />60
<br />1126
<br />1
<br />2 Bed / 2 Bath
<br />B6 UFAS
<br />1102
<br />0
<br />1102
<br />1
<br />3 Bed / 2 Bath
<br />C1
<br />1305
<br />1 60
<br />1365
<br />19
<br />20
<br />20.83%
<br />3 Bed / 3 Bath
<br />C2 UFAS
<br />1305
<br />60
<br />1365
<br />1
<br />Total Units in Project - All Types
<br />1 96
<br />100.00%
<br />C1
<br />B2 B1 B3 2 HR FIRE WALL
<br />A3 A3
<br />B3 B1 B1
<br />131 B2 61
<br />B3
<br />C1 B2 63 131
<br />C1 B2
<br />B2 Al
<br />C1 Al C1
<br />62B1 2 HR FIRE WALL C1
<br />B3
<br />A3 B1
<br />B3 61
<br />B1
<br />BUILDING SEPARATION FROM APARTMENT BUILDING COMPLYING WITH FBC-B
<br />PLUMBING FB -P 2010 EDITION
<br />FLORIDA BUILDING CODE, PLU G ( C )
<br />NOTE 1: THIS INFORMATION SHALL NOT BE USED FOR CONDOMINIUM DOCUMENTS.
<br />B3
<br />B2
<br />B1
<br />SECTION 3104
<br />FLORIDA FIRE PREVENTION CODE (FFPC) 5TH EDITION
<br />NOTE 2: UNIT AREAS LISTED ARE FROM CENTER LINE OF TENANT SEPARATION AND OUTSIDE OF
<br />C
<br />B2 6-UFA
<br />EXT./BREEZEWAY WALLS. AREAS ARE APPROX.
<br />B1.
<br />NATIONAL ELECTRICAL CODE008 EDITION
<br />(NEC)( )
<br />C1 VISUAL/HEARING IMPAIRED UNIT
<br />B2
<br />CLUBHOUSE INTERIOR FINISHES (FBC-C TABLE 803.9)
<br />B2 Al
<br />APARTMENT ACCESSIBILITY
<br />C1
<br />Al C1
<br />VERTICAL EXIT& PASSAGE WAY = B
<br />= B
<br />ALL UNITS ARE DESIGNED TO COMPLY WI THE FAIR HOUSING ACT OF 1980 AND
<br />UNIT TYPES
<br />62
<br />1131
<br />2 HR FIRE WALL C1
<br />EXIT ACCESS
<br />DESIGN FEATURES AS REQUIRED PER FLORIDA HOUSING STANDARDS. 5% OF UNITS
<br />B3
<br />ROOM & ENCLOSED SPACES = C
<br />ARE DESIGNED TO COMPLY WITH UFAS AS REQUIRED PER SECTION 504 AND THE
<br />A3 '
<br />83.
<br />A3
<br />; B1
<br />FLORIDA BUILDING CODE - ACCESSIBILITY 2012. IN INSTANCES WHERE THESE
<br />B1
<br />61
<br />CLUBHOUSE OCCUPANCY & MEANS OF EGRESS
<br />STANDARDS DIFFER THE UNITS WERE DESIGNED TO COMPLY WITH THE MOST
<br />i
<br />63
<br />B2
<br />B1 VISUAL/HEARING IMPAIRED UNIT
<br />OCCUPANCY LOAD (PER FBC 1004.1) GROUP: A3
<br />STRINGENT REQUIREMENT. REFER TO BUILDING PLANS FOR LOCATIONS.
<br />i f
<br />C1
<br />B2 63
<br />ASSEMBLY AREA I FLOOR AREA PER OCC. OCCUPANTS
<br />ADDITIONALLY, 2% OF UNITS SHALL BE ACCESSIBLE TO PERSONS WITH HEARING AND
<br />C1
<br />B2 4-UFA
<br />CLUBROOM 801 SQ.FT. / 15 SQ.FT.
<br />54
<br />VISION IMPAIRMENTS. REFER TO MEP DRAWINGS FOR RESPECTIVE NOTATIONS.
<br />I
<br />Al
<br />5-UFAS
<br />FITNESS (W / EQUIP.) 523 SQ.FT. / 50 SQ.FT.
<br />11
<br />y
<br />2-UFA
<br />Al C1
<br />CLASSROOM 284 SQ.FT. / 15 SQ.FT.
<br />19
<br />APARTMENT CODE COMPLIANCE
<br />61
<br />LOBBY 683 SQ.FT. / 15 SQ.FT.
<br />46
<br />OCCUPANCY TYPE R-2 RESIDENTIAL
<br />UNIT Al: 1 BED / 1 BATH UNIT A2-UFAS: 1 BED / 1 BATH UNIT A3: 1 BED / 1 BATH
<br />B2
<br />8 3
<br />2HR FIRE WALL C1
<br />CONSTRUCTION TYPE TYPE V-A, SPRINKLERED (FIRE SPRINKLER
<br />A3 '
<br />B3
<br />A3
<br />61
<br />BUSINESS
<br />SYSTEM NFPA 13R PER FBC 903.3.1.2)
<br />B1
<br />B1
<br />LEASING 541 SQ.FT. /100 SQ.FT.
<br />6
<br />R�
<br />B1-VISUAL/HEARING IMPAIRED UNIT
<br />(INCLUDES MANAGER'S OFFICE)
<br />AREA & HEIGHT LIMITATION (FBC-B TABLE 503)
<br />REQUIRED/ALLOWED
<br />PROPOSED
<br />CONFERENCE ROOM 150 SQ.FT. / 100 SQ. FT.
<br />2
<br />MAX HEIGHT
<br />60'*
<br />45'-0"
<br />COMPUTER ROOM 167 SQ.FT. 1100 SQ.FT.
<br />2
<br />MAX NUMBER OF STORIES
<br />4 STORIES*
<br />4 STORIES
<br />MAIL 84 SQ.FT. / 100 SQ. FT.
<br />1
<br />MAXIMUM AREA PER FLOOR PER AREA MODIFICATION CALCS BELOW
<br />ACCESSORY AREAS
<br />FIRE PROTECTION (FBC-B TABLE 601 & 602):.
<br />MECH. CLOSET & JANITOR 272 SQ.FT. 1300 SQ.FT.
<br />1
<br />STRUCTURAL FRAME
<br />1 HR
<br />1 HR
<br />EXTERIOR BEARING WALLS
<br />1 HR
<br />1 HR
<br />TOTAL 142 PERSONS
<br />INTERIOR BEARING WALLS
<br />1 HR
<br />1 HR
<br />INTERIOR NON -BEARING WALLS
<br />0 HR
<br />0 HR
<br />REQUIRED
<br />PROVIDED
<br />EXTERIOR NON -BEARING WALLS
<br />0 HR
<br />0 HR
<br />TRAVEL DISTANCE (FBC-B TABLE 1016.1) 200'
<br />50'-10"
<br />FLOOR CONSTRUCTION
<br />1 HR
<br />1 HR
<br />EXITING REQUIREMENTS (FBC-B TABLE 1019.1) 2 EXITS
<br />2+ EXITS
<br />ROOF CONSTRUCTION
<br />1 HR
<br />1 HR
<br />CLUBHOUSE OCCUPANCY DIAGRAM
<br />DWELLING UNIT SEPARATION WALLS (FBC 708)
<br />1 HR
<br />1 HR
<br />PER LEGEND IN OCCUPANCY TABLE
<br />FLOOR/ CEILING ASSEMBLY (FBC-B 711)
<br />1 HR
<br />1 HR
<br />REFER TO SHEET A1.25 FOR LIFE SAFETY PLAN
<br />ELEVATOR SHAFT ENCLOSURE (FBC-B 708.4)
<br />2HR
<br />2HR
<br />BUILDING SEPARATION FIRE WALL
<br />2 HR**
<br />2HR
<br />T
<br />I :
<br />* AUTOMATIC SPRINKLER SYSTEM INCREASE OF 1 STORY, BUT NOT EXCEEDING 60
<br />I
<br />FEET FOR GROUP R, PER FBC-B 504.2.
<br />** FIRE RESISTANCE RATING PER FBC-B TABLE
<br />706.4 NOTE A.
<br />=:
<br />APARTMENT BLDG AREA MODIFICATION CALCS (FBC-B 506.2)
<br />BUILDING TYPE FRONTAGE INCREASE
<br />ALLOWABLE AREA
<br />PROVIDED
<br />\
<br />BUILDING
<br />W = 30 If = [474'-11"/613'-2" - 0.25] 30/30
<br />12,000 SF (TABLE 503)
<br />F = 474'-11" If = [0.77-0.25] 1
<br />+[12,000 X 0.52]
<br />P = 613'-2" If = 0.52
<br />18,240 SF
<br />13,429 SF
<br />o
<br />BUILDING If
<br />W = 30 If = [779'-11"/843'-1" - 0.25] 30/30
<br />12,000 SF (TABLE 503)
<br />CLUBHOUSE PLUMBING FIXTURE CALCS (FBC-P 403.1
<br />& 403.8)
<br />F = 779'-11" If = [0.92-0.25] 1
<br />+[12,000 X 0.67]
<br />TOTAL OCCUPANTS 142 OCCUPANTS
<br />P = 843'-1" If = 0.67
<br />20,040 SF
<br />18,940 SF
<br />ASSUMED 50% MEN 71 OCCUPANTS
<br />ASSUMED 50% WOMEN 71 OCCUPANTS
<br />POOL SIZE = < 2,500 SF
<br />■ APT. OCCUPANCY & MEANS OF EGRESS (FBC-B CHAPTER 10)
<br />REQUIRED
<br />OCCUPANCY LOAD (S.F. / OCC.)
<br />GROUP
<br />FLOOR AREA
<br />PER
<br />RESIDENTIAL UNITS
<br />R-2
<br />200 S.F./ OCC.
<br />OCCUPANT + PER POOL = TOTAL
<br />TOTAL
<br />M'EN'S LOAD SIZE REQUIRED PROVIDED
<br />TRAVEL DISTANCE
<br />ALLOWED
<br />PROVIDED
<br />WC (1 PER 125) 1 1 2
<br />1
<br />WITHIN DWELLING UNITS
<br />75'-0"
<br />48'-0"
<br />LAVATORIES (1 PER 200) 1 1 2
<br />2
<br />UNIT ENTRY TO OUTSIDE OF BLDG.
<br />200'-0"
<br />188'-0"
<br />URINAL 0 1 1
<br />2
<br />EXITING REQUIREMENTS
<br />REQUIRED
<br />PROVIDED
<br />WOMEN'S
<br />NUMBER OF EXITS
<br />2 EXITS
<br />2 / 3' EXITS
<br />WC (1 PER 65) 2 1 3
<br />3
<br />STAIR
<br />LAVATORIES (1 PER 200) 1 1 2
<br />2
<br />WIDTH
<br />44" (MIN)
<br />44"
<br />RISE
<br />7" (MAX)
<br />6 3/4"
<br />SERVICE SINK 1 0 1
<br />1
<br />RUN
<br />11" (MIN)
<br />11"
<br />DRINKING FTN (1 PER 500) 1 0 2
<br />2 (HI/LOW)
<br />LANDING
<br />44" (MIN)
<br />44"
<br />HEADROOM
<br />80"
<br />>80"
<br />TRASH COMPACTOR ENCLOSURE CODE COMPLIANCE
<br />HANDRAIL DIAMETER
<br />1.25"-2" (MAX)
<br />1.5"
<br />OCCUPANCY TYPE U UTILITY
<br />HANDRAIL PROJECTION FROM WALL
<br />1.5" (NFPA)
<br />1.5"
<br />CONSTRUCTION TYPE TYPE V-B, UNSPRINKLERED
<br />APARTMENT INTERIOR FINISHES (FBC-C TABLE 803.9)
<br />AREA & HEIGHT LIMITATION (FBC-B TABLE 503): REQUIRED/ALLOWED
<br />PROPOSED
<br />VERTICAL EXIT & PASSAGE WAY
<br />= C
<br />MAX HEIGHT 40'
<br />91-411
<br />EXIT ACCESS
<br />= C
<br />MAX NUMBER OF STORIES 1 STORIES
<br />1 STORIES
<br />ROOM & ENCLOSED SPACES
<br />= C
<br />MAXIMUM AREA PER FLOOR 5,500 S.F.
<br />897 S.F.
<br />FIRE PROTECTION (FBC-B TABLE 601 & 602):
<br />STRUCTURAL FRAME 0 HR
<br />0 HR
<br />EXTERIOR BEARING WALLS' 0 HR
<br />0 HR
<br />INTERIOR BEARING WALLS 0 HR
<br />0 HR
<br />INTERIOR NON -BEARING WALLS 0 HR
<br />0 HR
<br />EXTERIOR NON -BEARING WALLS 0 HR
<br />0 HR
<br />FLOOR CONSTRUCTION 0 HR
<br />0 HR
<br />ROOF CONSTRUCTION 0 HIR
<br />0 HR
<br />UNIT 131: 2 BED / 2 BATH
<br />UNIT B4-UFAS: 2 BED / 2 BATH
<br />UNIT Cl: 3 BED / 2 BATH
<br />■ BUILDING AREA TABLE
<br />UNIT B2: 2 BED / 2 BATH
<br />UNIT B5-UFAS: 2 BED / 2 BATH
<br />UNIT 133: 2 BED / 2 BATH
<br />UNIT B6-UFAS: 2 BED / 2BATH
<br />UNIT C2: 3 BED / 2 BATH
<br />BUILDING II (56 UNITS)
<br />(8) A3 -1 BED l 1 BATH
<br />(16) B1 - 2 BED / 2 BATH
<br />(8) B2 - 2 BED / 2 BATH
<br />(12) B3 - 2 BED 12 BATH
<br />(11) C1 - 3 BED 12 BATH
<br />(1) C2-UFAS - 3 BED / 2 BATH
<br />BUILDING I
<br />BUILDING II
<br />CLUBHOUSE
<br /># UNITS / BLDG.
<br />40
<br />56
<br />0
<br />BUILDING AREA (SF)
<br />BUILDING AREA (SF)
<br />BUILDING AREA (SF)
<br />BLDG. FLOORS
<br />A/C AREA
<br />NON -A/C
<br />AREA
<br />TOTAL
<br />A/C AREA
<br />NON -A/C
<br />AREA
<br />TOTAL
<br />A/C AREA
<br />NON -A/C
<br />AREA
<br />TOTAL
<br />1ST FLOOR AREAS
<br />10,595
<br />2,834
<br />13,429
<br />15,417
<br />3,523
<br />48,940
<br />4,553
<br />1,188
<br />5,741
<br />2ND FLOOR AREAS
<br />10,595
<br />1,879
<br />12,474
<br />15,417
<br />3,034
<br />18,451
<br />0
<br />0
<br />0
<br />3RD FLOOR AREAS
<br />10,595
<br />1,879
<br />12,474
<br />15,417
<br />3,034
<br />18,451
<br />0
<br />0
<br />0
<br />4TH FLOOR AREAS
<br />10,595
<br />1,879
<br />12,474
<br />15,417
<br />3,034
<br />18,451
<br />0
<br />0
<br />0
<br />TOTALS
<br />42,380
<br />8,471
<br />50,851
<br />61,668
<br />12,625
<br />74,293
<br />4,553
<br />1,188
<br />5,741
<br /># OF BUILDINGS
<br />1
<br />1
<br />1
<br />TOTAL AREA
<br />50,851
<br />74,293
<br />5,741
<br />PROJECT TOTAL
<br />130,885
<br />BUILDING I (40 UNITS)
<br />(7) Al-1 BED / 1 BATH
<br />(1) A2-UFAS -1 BED / 1 BATH
<br />(7) B1 - 2 BED / 2 BATH
<br />(11)B2-2 BED/2 BATH
<br />(3) B3 - 2 BED / 2 BATH
<br />(1) B4-UFAS - 2 BED / 2 BATH
<br />(1) B5-UFAS - 2 BED / 2 BATH
<br />(1) B5-UFAS - 2 BED / 2 BATH
<br />(8) C1 - 3 BED / 2 BATH
<br />1�7�Z�J►'.I
<br />ARCHITECTURE &
<br />INTERIOR DESIGN, INC.
<br />PLANNING I ARCHITECTURE 11INTERIORDESIGN
<br />745 orienta avenue, suite 1121
<br />altamonte springs, fl 32701
<br />phone: 407.830.1400
<br />fax: 407.830.4143
<br />AA0002731
<br />www.forumarchitecture.com
<br />°°° °°°
<br />°°° °°°
<br />O 13
<br />°°
<br />BENEFICIAL
<br />COMMUNITIES
<br />3550 S. Tamiami Trail Suite 301 Sarasota, FL 34239
<br />Summerset
<br />Apartments
<br />o ZeDhvrhills. FL
<br />0 SHEET REVISIONS:
<br />EDITED BY: KG
<br />PROJECT NO. 14-2984
<br />Apartments
<br />Code Compliance &
<br />Matrix
<br />A1.02