DWELLING UNIT TO BREEZEWAY 1 HOUR <br />DWELLING UNIT TO DWELLING UNIT 1 HOUR <br />ELEVATOR HOISTWAY 2 HOURS <br />BUILDING SEPARATION FIRE WALL 2 HOURS <br />1 <br />ARCHITECTURE & <br />0 SHEET NOTES <br />A RATINGS SHOWN ARE FOR SEPARATION ONLY. <br />REFER TO SHEETS A1.04 & A1.05 FOR STRUCTURAL <br />RATINGS. <br />B SEE FIRE PROTECTION DRAWINGS FOR STANDPIPE <br />DETAILS. COORDINATE LOCATIONS WITH <br />ARCHITECTURAL PLANS. <br />C SEE FIRE PROTECTION DRAWINGS FOR <br />IDENTIFICATION OF SPRINKLER AREAS & SPRINKLER <br />SYSTEM TYPE. <br />D SEPARATE E PERMITS SHALL BE REQUIRED FOR THE <br />FIRE ALARM SYSTEM, FIRE SPRINKLER SYSTEM & <br />FIRE SUPPRESSION SYSTEM. <br />E REFER TO ELECTRICAL DRAWINGS FOR EXIT AND <br />EMERGENCY LIGHT LOCATIONS. <br />® EGRESS REQUIREMENTS <br />FFPC/NFPA/FBC MAXIMUM TRAVEL DISTANCE <br />BUILDING - SPRINKLERED NFPA 13R 200'-0" <br />(REMOTE CORNER OF ROOM TO NEAREST STAIR) <br />LEGEND <br />DESIGNATES 1 HR FIRE RATING FOR <br />ADJACENT WALL <br />DESIGNATES 2 HR FIRE RATING FOR <br />ADJACENT WALL <br />rI E SEMI -RECESSED FIRE EXTINGUISHER <br />IN CABINET, REFER TO GEN. NOTES <br />FLOOR OCCUPANCY (GROSS UNIT / <br />120 <br />SQUARE FOOTAGE) USING STAIRS <br />(TOTAL / NUMBER OF STAIRS) <br />—STARTING POINT <br />�D=12LO-__ <br />TOTAL DISTANCE TO GRADE <br />LEVEL/EXIT <br />PATH OF TRAVEL <br />FIRE RATING CONTINUITY AT ROOF <br />TRUSS. 10' MIN. FROM FIRE WALL. <br />REFER TO DETAILS ON SHEET A7.16. <br />UNITS <br />OCCUPANTS <br />DISTANCE WITHIN <br />UNIT TO EGRESS <br />DOOR <br />Al <br />4 <br />34 LF. <br />A2 UFAS <br />4 <br />35 LF. <br />A3 <br />4 <br />39 LF. <br />131 <br />6 <br />45 LF. <br />B2 <br />6 <br />45 LF. <br />B3 <br />6 <br />45 LF. <br />B4 <br />6 <br />45 LF. <br />B5 <br />6 <br />45 LF. <br />B6 <br />6 <br />45 LF. <br />C1 <br />7 <br />48 LF. <br />C2 UFAS <br />7 <br />39 LF. <br />KEY PLAN <br />M <br />0 <br />N <br />co <br />0 <br />LO <br />o. <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHrrECTURE I INTERIORDESIGN <br />745 orients avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />nos nnn <br />no ®nn <br />o® <br />BENEFICIAL <br />COMMUNITIES <br />3550 S. Tamiami Trail Suite 301 Sarasota, FL 34239 <br />Summerset <br />Apartments <br />Zephyrhills, FL <br />05/08/2015 <br />0 SHEET REVISIONS: <br />EDITED BY: KG <br />Building 1 & Clubhouse <br />First Floor Life Safety <br />Plan <br />A1.1 1 <br />