STRUCTURAL NOTES <br />CONTRACTOR NOTE M <br />1. <br />THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN <br />CONNECTION WITH THE WORK. GUTHERMAN STRUCTURAL, INC. IS NOT RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION OR <br />FOR RELATED SAFETY PRECAUTIONS AND PROGRAMS. 2. <br />CODES AND STANDARDS <br />1. WIND LOADS AS PER: <br />A. FLORIDA BUILDING CODE 2010 EDITION WITH AN ULTIMATE DESIGN WIND SPEED OF 140 MPH, EXPOSURE C, NOMINAL DESIGN <br />WIND SPEED OF 108 MPH, +/ 0.18 INTERNAL PRESSURE COEFFICIENT, AND BUILDING RISK CATEGORY II. <br />B. THIS BUILDING IS DESIGNED AS AN ENCLOSED BUILDING. <br />2. THE PROJECT WAS DESIGNED IN ACCORDANCE WITH THE: <br />3. <br />A. 2010 FLORIDA BUILDING CODE. <br />B. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318/ 2008 EDITION). 4 <br />C. MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 315/ LATEST EDITION). <br />D. MANUAL OF STANDARD PRACTICE FOR WELDING REINFORCING STEEL, INSERTS & CONNECTIONS IN REINFORCED CONCRETE 5 <br />CONSTRUCTION. AWS. D1.4/ LATEST EDITION. <br />E. SPECIFICATION FOR THE DESIGN, FABRICATION & ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. (AMERICAN INSTITUTE OF 6. <br />STEEL CONSTRUCTION) RISC 13TH EDITION (ASD). <br />F. SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS, ACI 301/LATEST EDITION. <br />G. BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530, 530.1/ASCE 5, 6/TMS 402, 7. <br />602/2008 EDITIONS). <br />H. NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION, 2005 EDITION. 8. <br />1. LIGHT GAUGE STUD FRAMING SHALL COMPLY WITH ASTM STANDARDS AND HAVE BEEN DESIGNED IN ACCORDANCE WITH THE <br />AMERICAN IRON AND STEEL INSTITUTE'S SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS, 2001 <br />WITH 2O04 SUPPLEMENT. <br />J. ASCE7 - 10. 9• <br />3. ARCHITECTURAL AND MECHANICAL DRAWINGS: 1 <br />A. THE STRUCTURAL DRAWINGS ARE PART OF THE CONTRACT DOCUMENTS AND DO NOT BY THEMSELVES PROVIDE ALL THE <br />INFORMATION REQUIRED TO PROPERLY COMPLETE THE PROJECT STRUCTURE. THE GENERAL CONTRACTOR SHALL CONSULT THE <br />ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND COORDINATE THE INFORMATION CONTAINED IN THESE DRAWINGS <br />WITH THE STRUCTURAL DRAWINGS TO PROPERLY CONSTRUCT THE PROJECT. <br />B. REFER TO ARCHITECTURAL, MECHANICAL OR ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS, DEPRESSIONS, FINISHES, <br />INSERTS, BOLTS SETTINGS, DRAINS, REGLETS, ETC. 11 <br />C. BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS TO PROPERLY <br />SIZE OR FIT THE WORK. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED BY THE OWNER RESULTING FROM THE <br />CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT. <br />D. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH ANY 1 <br />WORK. <br />E. ALL STRUCTURES HAVE BEEN DESIGNED TO RESIST THE DESIGN LOADS LISTED ONLY AS COMPLETED STRUCTURES. THE <br />GENERAL CONTRACTOR SHALL FULLY BRACE AND OTHERWISE PROTECT WORK IN PROGRESS UNTIL THE STRUCTURES ARE 1 <br />COMPLETED. THE GENERAL CONTRACTOR SHALL ALSO INSURE THAT ITS OPERATIONS AND PROCEDURES PROVIDE NO LOADING <br />GREATER THAN THE DESIGN LOADS LISTED ON ANY MEMBER. <br />4. SECTIONS AND DETAILS: <br />ALL DETAILS, SECTIONS AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR 1 <br />SITUATIONS ELSEWHERE UNLESS OTHERWISE SHOWN. <br />5. THRESHOLD INSPEC11ONS SHALL BE PERFORMED DURING CONSTRUCTION OF THIS BUILDING AS REQUIRED BY SECTION 110.3.7 OF 1 <br />FLORIDA BUILDING CODE. <br />6. MATERIALS AND ASSEMBLY TEST AS FOLLOWS: 1 <br />A. EXTERIOR WINDOWS, SLIDING AND PATIO GLASS DOORS SHALL BE TESTED BY AN APPROVED INDEPENDENT TESTING <br />LABORATORY, AND SHALL BE LABELED WITH AN APPROVED LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE <br />CHARACTERISTICS AND APPROVED PRODUCT CERTIFICATION AGENCY, TESTING LABORATORY, EVALUATION ENTITY OR FLORIDA <br />STATE WIDE PRODUCT APPROVAL NUMBER TO INDICATE COMPLIANCE WITH THE REQUIREMENTS OF ONE OF THE FOLLOWING <br />SPECIFICATIONS: ANSI/AAMA/NWWDA 101/I.S. 2-97 OR TAS 202 (HVHZ SHALL COMPLY WITH TAS 202) <br />B. EXTERIOR DOOR ASSEMBLIES SHALL BE TESTED FOR STRUCTURAL INTEGRITY IN ACCORDANCE WITH ASTM E330 AT A LOAD OF <br />1.5 TIMES THE REQUIRED DESIGN PRESSURE LOAD. THE LOAD SHALL BE SUSTAINED FOR 10 SECONDS WITH NO PERMANENT <br />DEFORMATION OF ANY MAIN FRAME OR PANEL MEMBER IN EXCESS OF 0.4 PERCENT OF ITS SPAN AFTER THE LOAD IS <br />REMOVED. HVHZ SHALL COMPLY WITH TAS 202. AFTER EACH SPECIFIED LOADING, THERE SHALL BE NO GLASS BREAKAGE, 1 <br />PERMANENT DAMAGE TO FASTENERS HARDWARE PARTS OR ANY OTHER DAMAGE WHICH CAUSES THE DOOR TO BE <br />INOPERABLE. <br />C. SECTIONAL GARAGE DOORS SHALL BE TESTED FOR DETERMINATION OF STRUCTURAL PERFORMANCE UNDER UNIFORM STA11C AIR <br />PRESSURE DIFFERENCE IN ACCORDANCE WITH ANSI/DASMA 115 OR TAS 201,202 AND 203. 1 <br />D. CUSTOM (ONE OF A KIND) EXTERIOR DOOR ASSEMBLIES SHALL BE TESTED BY AN APPROVED TESTING LABORATORY OR BE <br />ENGINEERED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICES. <br />E. WINDOW AND DOOR ASSEMBLIES SHALL BE ANCHORED IN ACCORDANCE WITH THE PUBLISHED MANUFACTURER'S 1 <br />RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURE SPECIFIED. SUBSTITUTE ANCHORING SYSTEM USED FOR SUBSTRATES <br />NOT SPECIFIED BY THE FENSTRATION MANUFACTURER SHALL PROVIDE EQUAL OR GREATER ANCHORING PERFORMANCE AS <br />DEMONSTRATED BY ACCEPTED ENGINEERING PRACTICE. <br />FOUNDATION 2 <br />1. ALL SITE PREPARATION AND EXCAVATION WORK IS TO BE PERFORMED IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS OF A <br />SITE SPECIFIC SOILS AND FOUNDATIONS INVESTIGATION PREPARED BY TERRACON CONSULTANTS, INC., TERRACON PROJECT No. <br />H4155059, DATED SEPTEMBER 2, 2015 PRIOR TO FOUNDATION WORK. <br />2. THE BUILDING SITE SHOULD BE EXCAVATED TO THE DEPTH AND EXTENT INDICATED IN THE SOILS REPORT. ALL SUB -GRADES SHALL <br />BE APPROVED IN WRITING BY THE SOILS ENGINEER PRIOR TO BACKFILLING. <br />3. BOTTOM OF FOOTINGS TO BEAR ON CONTROLLED COMPACTED FILL CAPABLE OF SAFELY SUPPORTING 2500 POUNDS PER SQUARE <br />FOOT (PSF). <br />4. SOILS SUPPORTING ALL FOOTINGS MUST BE INSPECTED AND APPROVED BY A REGISTERED SOILS ENGINEER BEFORE COMMENCING <br />WORK. APPROVAL IN WRITING MUST INDICATE THE SOIL IS ADEQUATE TO SAFELY SUSTAIN SPECIFIED SOIL BEARING PRESSURE. <br />5. TOP OF ALL EXTERIOR FOOTINGS SHALL BE MINIMUM 12 INCHES BELOW EXTERIOR FINISHED GRADE, UNLESS NOTED OTHERWISE. <br />6. EXCAVATION AND BACKFILL: <br />A. ALL EXCAVATION SHALL BE KEPT DRY. EXCAVATE TO DEPTHS AND DIMENSIONS INDICATED. TAKE EVERY PRECAUTION TO <br />GUARD AGAINST ANY MOVEMENT OR SETTLEMENT OF ADJACENT STRUCTURES, UTILITIES, PIPING, ETC. 1. <br />B. PROVIDE ANY BRACING OR SHORING NECESSARY TO AVOID SETTLEMENT OR DISPLACEMENT OF EXISTING FOUNDATION OR <br />STRUCTURES. <br />7. CENTERLINE OF FOOTINGS SHALL COINCIDE WITH CENTERLINE OF COLUMNS AND WALLS UNLESS OTHERWISE NOTED ON DRAWINGS. <br />8. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE VERIFIED AND COORDINATED WITH THE <br />ARCHITECTURAL DRAWINGS BY THE CONTRACTOR BEFORE PROCEEDING WITH THE CONSTRUCTION. DISCREPANCIES SHALL BE <br />BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER IN WRITING BEFORE PROCEEDING WITH ANY WORK. 2 <br />9. THE FOUNDATION/ SLAB SYSTEM U11LIZED FOR THIS PROJECT SHALL BE A POST -TENSIONED SYSTEM. THE POST -TENSIONED <br />SYSTEM SHALL BE DESIGNED BY A SPECIALTY ENGINEER (PROFESSIONAL ENGINEER) REGISTERED IN THE STATE THAT THE PROJECT IS 3. <br />CONSTRUCTED. THE SPECIALTY ENGINEER SHALL UTILIZE THE GEOTECHNICAL REPORT NOTED ABOVE FOR THEIR DESIGN. <br />CONCRETE 4. <br />1. CONCRETE ELEMENTS TO HAVE THE FOLLOWING STRENGTHS: <br />A. FOUNDATIONS 3000 PSI <br />B. SLAB -ON -GRADE 3000 PSI 5 <br />C. CONCRETE WALLS 4000 PSI <br />D. MASONRY GROUT 3000 PSI <br />s <br />ALL OTHER CONCRETE TO BE 4000 PSI UNLESS NOTED OTHERWISE. <br />7 <br />2. ALL CONCRETE SHALL BE READY MIX AND MEET THE FOLLOWING REQUIREMENTS: <br />8 <br />A. A MINIMUM COMPRESSIVE STRENGTH AS NOTED ABOVE. <br />B. SLUMPS SHALL BE 4-INCHES MINIMUM AND 6-INCHES MAXIMUM. <br />C. CONCRETE SHALL HAVE 3 PERCENT AIR ENTRAINMENT. <br />D. ALL CONCRETE TO HAVE MAXIMUM WATER/CEMENT RATIO OF 0.55. <br />5. <br />9. <br />ASONRY WALL CONSTRUCTION <br />MASONRY CONSTRUCTION SHALL CONFORM TO THE "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-05/ASCE <br />5-05/TMS 402-05)" AND THE "SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530.1-05/ASCE 6-05/TMS 602-05)". <br />CONCRETE MASONRY UNITS (CMU) SHALL BE: <br />A. LOAD BEARING ASTM C90 <br />B. TYPE 11 NON -MOISTURE CONTROLLED UNITS <br />C. MEDIUM WEIGHT or NORMAL WEIGHT, GRADE N <br />D. ALL CONCRETE MASONRY UNITS (CMU) SHALL BE LAID IN A FULL BED OF MORTAR IN RUNNING BOND (UNLESS NOTED <br />OTHERWISE). <br />E. CMU SHALL HAVE A MINIMUM NET COMPRESSIVE STRENGTH OF 2800 PSI (f'm = 2000 PSI) AS CALCULATED IN ACCORDANCE <br />WITH ASTM C1314. <br />ALL MASONRY SHALL BE NOMINAL SIZE UNITS 8x8x16 (7 5/8"x7 5/8"x15 5/8") . PROVIDE HALF-SIZE, KNOCK -OUT, OR U-BLOCKS <br />WHERE SPECIFIED. <br />MORTAR SHALL CONFORM TO ASTM C270. PROVIDE TYPE M FOR BELOW GRADE AND TYPE S FOR ABOVE GRADE. <br />DO NOT WET MASONRY PRIOR TO APPLYING MORTAR. <br />REINFORCED CELLS OF CONCRETE MASONRY UNITS SHALL BE FILLED WITH COARSE GROUT THAT CONFORMS TO ASTM C476 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. <br />FULLY GROUT ALL MASONRY BELOW GRADE. <br />ALL CONCRETE MASONRY BEARING AND SHEAR WALLS SHALL BE INSPECTED BY A CERTIFIED INSPECTION COMPANY AND <br />CONSTRUCTED IN ACCORDANCE WITH THE "BUILDING CODE REQUIREMENT FOR MASONRY STRUCTURES" (ACI 530/ASCE 5/TSM 402) <br />AND "SPECIFICATIONS FOR MASONRY STRUCTURES" (ACI 530.1/ASCE 6/TSM 602)/ 2005 EDITIONS. <br />VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS FILLED WITH COARSE GROUT. <br />0. MINIMUM LAP SPLICES FOR REINFORCING STEEL IN CMU SHALL BE PER SECTION 2107.3 OF THE FLORIDA BUILDING CODE. FOR <br />GRADE 60 REINFORCEMENT = 48 BAR DIAMETERS. <br />A. LAP SPLICES SHALL OCCUR DIRECTLY ABOVE FOOTINGS AND SLABS. NO SPLICES ARE ALLOWED AT MID -HEIGHT OF WALL. <br />B. LAP SPLICES THAT OCCUR AT CANTILEVERED WALLS SUCH AS: <br />PARAPETS, RETAINING WALLS, ETCETERA, SHALL HAVE LAP SPLICES OF 72 BAR DIAMETERS. <br />VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP AND BOTTOM AND AT A MAXIMUM VERTICAL SPACING OF 8'-0". <br />REINFORCEMENT SHALL BE PLACED IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS NOTED OTHERWISE. SEE TYPICAL <br />GROUTING DETAILS FOR ADDITIONAL INFORMATION. <br />2. ALL REINFORCING STEEL SHALL BE MANUFACTURED FROM HIGH STRENGTH BILLET STEEL CONFORMING TO ASTM DESIGNATION A 615 <br />GRADE 60. <br />3. PROVIDE GALVANIZED, 9 GAUGE, LADDER TYPE HORIZONTAL WALL REINFORCEMENT AT 16" O.C. VERTICALLY AT MASONRY WALL <br />LOCATIONS, UNLESS NOTED OTHERWISE. SPLICED WIRE REINFORCEMENT SHALL BE LAPPED AT LEAST 8" AND CONTAIN AT LEAST ONE <br />CROSS WIRE OF EACH PIECE OF REINFORCEMENT WITHIN THE 6". AT INTERSECTIONS AND CORNERS PROVIDE FACTORY -MADE "T" <br />AND "L" SHAPED PIECES RESPECTIVELY. PROVIDE DOVE TAIL SLOT ANCHORS AT CONCRETE COLUMNS. <br />4. HOT DIPPED GALVANIZING FOR JOINT REINFORCEMENT, WALL TIES, ANCHORS AND INSERTS SHALL BE A MINIMUM COAT OF 1.5 <br />OUNCES PER SQUARE FOOT (PSF) (458/G/M2) COMPLYING WITH THE REQUIREMENTS OF ASTM A153, CLASS B. <br />WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, IT SHALL NOT BE SLOPED MORE THAN ONE HORIZONTAL IN <br />SIX VERTICALS. DOWELS SHALL BE GROUTED INTO A CORE IN VERTICAL ALIGNMENT, EVEN THOUGH IT IS IN AN ADJACENT CELL TO <br />THE VERTICAL WALL REINFORCEMENT. <br />6. MASONRY (C.M.U.) LINTELS: <br />A. A PRECAST CONCRETE LINTEL by CAST-CRETE SHALL BE PROVIDED OVER ALL MASONRY WALL OPENINGS, UNLESS NOTED <br />OTHERWISE. <br />B. LINTELS SHALL BE FULLY GROUTED WITH 3000 PSI CONCRETE MINIMUM. <br />C. LINTELS TO HAVE 4" MINIMUM BEARING AT EACH END. <br />D. SEE MASONRY LINTEL SCHEDULE FOR REINFORCEMENT REQUIREMENTS. <br />E. WHERE HORIZONTAL REINFORCEMENT IS REQUIRED PROVIDE A CMU KNOCK -OUT BLOCK COURSE, UNLESS NOTED OTHERWISE. <br />F. INSTALL LINTELS PER MANUFACTURER'S RECOMMENDATIONS, INCLUDING SHORING OF LINTEL. <br />7. PROVIDE A KNOCK OUT BLOCK OR U-BLOCK REINFORCED WITH 1 #5 CONTINUOUS AT THE SILL OF ALL WINDOW AND DOOR <br />OPENINGS. EXTEND 8" BEYOND EACH SIDE OF THE OPENING TYPICALLY. <br />8. MASONRY QUALITY ASSURANCE AND INSPECTION REQUIREMENTS SHALL FOLLOW THE PROVISIONS OF THE LATEST EDITION OF ACI <br />530/ASCE 5/-IMS 402, CHAPTER 1, SECTION 1.14.1.3 <br />EPDXY GROUT SHALL BE NON -SHRINK, HIGH CREEP RESISTANT, AND SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE PROPERTIES: <br />A) TENSILE STRENGTH, ASTM C 30: 1,500 PSI <br />B) FLEXURAL STRENGTH, ASTM C 580: 4,000 PSI <br />C) COMPRESSIVE STRENGTH, ASTM C 579: 1,600 PSI/7 DAYS. <br />0. MORTAR PLACEMENT: <br />o. USE 3/8" THICK JOINTS BETWEEN UNITS. <br />b. TOOL ALL JOINTS WITH A ROUND JOINTER WHEN THE MORTAR IS THUMBPRINT HARD, UNLESS OTHERWISE REQUIRED BY THE <br />CONTRACT DOCUMENTS. <br />C. PLACE MORTAR ON CLEAN UNITS WHILE THE MORTAR IS SOFT AND PLASTIC. <br />DO NOT DISTURB THE UNIT AFTER IT IS IN111ALLY POSITIONED. <br />e. PLACE MORTAR SO THAT ALL JOINTS OF SOLID UNITS ARE FULLY FILLED WITH MORTAR. <br />f. FILL THE BED AND HEAD JOINTS OF HOLLOW UNITS WITH MORTAR, SPREAD ACROSS THE WIDTH OF THE FACE SHELLS. <br />g. MORTAR CROSS WEBS IN HOLLOW UNITS FOR THE FOLLOWING SITUATIONS: <br />(1.) ADJACENT TO CELLS TO BE GROUTED FOR PARTIALLY GROUTED CONSTRUCTION. <br />(2.) STARTING COURSE ON FOUNDATIONS. <br />h. REMOVE PROTRUSIONS OF MORTAR INTO COLLAR JOINTS, CAVITIES AND CELLS OF HOLLOW UNITS IF THEY PROJECT MORE THAN <br />1 /2". <br />i. DO NOT SLUSH MORTAR INTO HEAD JOINTS. <br />ji FILL HOLES IN THE MORTAR. <br />ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST AISC CODE. STRUCTURAL STEEL <br />SHALL CONFORM TO: <br />A. ASTM SPECIFICATION A992 GRADE 50 FOR ALL WIDE FLANGE BEAMS. <br />B. ASTM SPECIFICATION A36 FOR MISCELLANEOUS STEEL SHAPES (ANGLES, PLATES, ETC.). <br />C. ASTM SPECIFICATION A500 GRADE B (FY=46 KSI) FOR SQUARE OR RECTANGULAR HSS SHAPES. <br />D. ASTM SPECIFICATION A500 GRADE B (FY=42 KSI) FOR ROUND HSS SHAPES. AT ROUND HSS WITH A WALL THICKNESS <br />GREATER THAN %" SHALL CONFORM TO ASTM SPECIFICATION A53 TYPE E, GRADE B (FY=35 KSI). <br />ALL MILL CAMBER TO BE ORIENTED UPWARD DURING FABRICATION AND ERECTION. STEEL BEAMS INSTALLED IN PARALLEL WITH <br />STEEL BAR JOISTS SHALL HAVE CAMBER EQUAL TO BAR JOISTS. <br />ALL STEEL TO HAVE A SHOP COAT OF RUST INHIBITIVE PAINT. AT STEEL SURFACES THAT IS TO RECEIVE SPRAYED ON <br />FIREPROOFING OR CONCRETE ENCASEMENT, DELETE PAINT. <br />ALL SHOP AND FIELD WELDING SHALL BE PERFORMED BY WELDERS QUALIFIED, AS DESCRIBED IN "AMERICAN WELDING SOCIETY'S <br />STANDARD QUALIFICATION PROCEDURE" (AWS D1.1), TO PERFORM THE TYPE OF WORK REQUIRED. <br />ALL CONNECTIONS SHALL BE BOLTED WITH 3/4" DIAMETER, A325-N HIGH STRENGTH BOLTS OR WELDED, UNLESS SHOWN OTHERWISE <br />ON THE DRAWINGS. <br />ALL STEEL WELDING RODS SHALL BE E70XX ELECTRODES. <br />SUBMIT ALL STEEL SHOP DRAWINGS FOR APPROVAL PRIOR TO ANY FABRICATION. <br />EQUIPMENT SUPPORTS: PROVIDE ALL SUPPORTING STEEL NOT INDICATED ON PLAN AS REQUIRED FOR THE INSTALLATION OF <br />MECHANICAL EQUIPMENT AND MATERIALS, INCLUDING ANGLES, CHANNELS, BEAMS, HANGERS, ETC. DO NOT SUPPORT EQUIPMENT OR <br />PIPING FROM METAL DECKING. <br />E. JOBSITE WATER SHALL NOT BE ADDED, SHOP DRAWINGS <br />3. ALL CONCRETE WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE ACI BUILDING CODE (ACI 318/ 2008 EDITION), THE ACI 1. THE SHOP DRAWINGS SHALL BE SUBMITTED IN COMPLETE PACKAGES FOR THE FOLLOWING: <br />DETAILING MANUAL (ACI 315/ 1994 EDITION), AND THE SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301/ <br />LATEST EDITION). A. CONCRETE MIX DESIGNS <br />B. CONCRETE REINFORCING STEEL AND WELDED WIRE FABRIC <br />4. SUBMIT ALL REINFORCING STEEL SHOP DRAWINGS FOR APPROVAL PRIOR TO ANY FABRICATION. C. CONCRETE MASONRY UNIT SUBMITTALS AND OTHER MASONRY ACCESSORIES <br />E. STRUCTURAL STEEL <br />5. CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS REQUIRED BY ACI SPECIFICATIONS. F. PRE-ENGINEERED STEEL STAIRS <br />G. PRE-ENGINEERED WOOD FLOOR AND ROOF TRUSSES <br />6. WELDED WIRE FABRIC SHALL COMPLY WITH ASTM A 185, UNLESS OTHERWISE SPECIFIED. PLACE FABRIC 2" CLEAR FROM TOP OF THE <br />SLAB IN SLAB ON GRADE AND SUPPORT ON SLAB BOLSTERS SPACED AT S-O" O.C. 2. PRE-ENGINEERED ITEMS SHALL BE SUBMITTED SIGNED AND SEALED BY A SPECIALTY ENGINEER REGISTERED IN THE STATE OF <br />co FLORIDA. <br />7. LAP ALL BARS WITH CLASS B TENSION LAP SPLICE UNLESS OTHERWISE NOTED ON DRAWINGS. LAP ALL WWF A MINIMUM OF 12 <br />II INCHES (UNLESS OTHERWISE NOTED). <br />ai <br />Can 8. REINFORCING BARS: <br />A. ALL REINFORCING STEEL SHALL BE MANUFACTURED FROM HIGH STRENGTH BILLET STEEL CONFORMING TO ASTM DESIGNATION A <br />I� 615 GRADE 60. <br />v B. AT CORNERS OF CONCRETE WALLS, BEAMS AND CONTINUOUS WALL FOOTINGS, PROVIDE (1-#5 OR MATCHING) HORIZONTAL <br />r BARS X 5'-0" BENT BAR FOR EACH HORIZONTAL BAR SCHEDULED AT EACH FACE. <br />LO C. ALL HOOKS SHOWN IN REINFORCEMENT SHALL BE ACI RECOMMENDED HOOKS UNLESS OTHERWISE NOTED. <br />0 <br />00 9. FOR GRADE BEAMS, LAP ALL TOP STEEL AT MID -SPAN AND LAP BOTTOM STEEL OVER SUPPORTS. <br />0 <br />0 <br />a� <br />16 <br />0 <br />a <br />WOOD <br />1. ALL STRUCTURAL WOOD MEMBERS ARE DESIGNED AS "DRY -USE". MOISTURE CONTENT MUST BE 19% OR LESS. STORE WOOD <br />FRAMING ABOVE GROUND AND UNDER TARPS WITH PROPER AIR CIRCULATION, IN SUCH A WAY TO PREVENT MOISTURE DAMAGE. <br />2. ALL NOTED LUMBER SHALL BE: <br />A. CONVENTIONAL LUMBER: <br />SOUTHERN PINE SPECIES #2 GRADE (SP2) OR APPROVED EQUAL. ALLOWABLE DESIGN STRESSES SHALL FOLLOW <br />NATIONAL DESIGN SPECIFICATION (NDS) (LATEST EDITION). <br />B. ENGINEERED LUMBER: <br />PARALLEL STRAND LUMBER (PSL), (PARALLAM PSL or EQUAL) WITH THE FOLLOWING DESIGN PROPERTIES: E _ <br />2.00x10^6, Fb = 2,900 PSI, Ft = 2,025 PSI, Fv = 290 PSI, Fc// = 2,900 PSI. (PROVIDE WOLMANIZED, PARALLAM <br />PLUS PSL or EQUAL AT EXTERIOR LOCATIONS.) <br />LAMINATED VENEER LUMBER (LVL), (MICROLLAM or EQUAL) WITH THE FOLLOWING DESIGN PROPERTIES: E = 1.9x10^6, Fb <br />= 2,600 PSI, Ft = 1,555 PSI, Fv = 285 PSI, Fc// = 2,510 PSI. <br />3. STUD WALLS SHALL BE FRAMED UTILIZING THE PLATFORM FRAME METHOD. PROVIDE 2x STUDS AT 16" O.C., MAXIMUM AT <br />STRUCTURAL WALLS. SEE PLAN NOTES FOR SIZE AND SPACING. WALLS SHALL HAVE A PRESSURE TREATED (P.T.) 2x SOLE PLATE <br />AT THE BOTTOM AND A DOUBLE 2x TOP PLATE, UNLESS NOTED OTHERWISE. <br />PROVIDE CONTINUOUS SOLID BLOCKING AT AT SHEATHING EDGES AND 4'-0" O.C. VERTICALLY, MAXIMUM. SOLID BLOCKING SHALL <br />MATCH VERTICAL STUD. <br />4. PROVIDE SP ACID PRESSURE TREATED (PT) LUMBER IN ACCORDANCE WITH AWPA STANDARDS TO A MINIMUM 0.40 PCF RETENTION <br />WHERE LUMBER IS IN CONTACT WITH CONCRETE/MASONRY OR OUTSIDE OF BUILDING AT EXTERIOR CONDITIONS. <br />5. ATTACH PT 2x SOLE PLATES TO CONCRETE SLABS WITH VO x 10" ANCHOR BOLTS AT 2'-8" O.C. AND AT EACH SIDE OF <br />DISCONTINUOUS ENDS. PROVIDE ONE ANCHOR BOLT WITHIN NINE INCHES OF EACH SOLE PLATE END. A MINIMUM OF TWO ANCHOR <br />BOLTS SHALL BE USED ON EACH SILL PLATE PIECE. IN LIEU OF ANCHOR BOLTS, CONTRACTOR MAY USE SIMPSON %"4 TITEN HD <br />HEAVY DUTY SCREW ANCHORS WITH 4Y2" EMBEDMENT AND 1Y'" EDGE DISTANCE AT 2'-8" O.C. ATTACH 2x SOLE PLATES TO WOOD <br />FRAMING WITH 16d COMMON NAILS AT 8" O.C., STAGGERED. SEE SHEAR WALL SCHEDULE FOR ATTACHMENT OF SOLE PLATES AT <br />SHEAR WALLS. <br />6. CONNECT STUD TO BOTTOM PLATE WITH SIMPSON SP1 AT 2'-8" O.C. ATTACH STUD BELOW TO STUD ABOVE (WHERE THERE IS <br />MORE THAN ONE STORY) WITH A SIMPSON CS20 STRAP AT 2'-8" O.C. ATTACH STUD TO THE TOP OF WALL AT THE DOUBLE TOP <br />PLATE WITH A SIMPSON SP2 AT 2'-8" Q.C. <br />7. ALL METAL CONNECTORS (BUCKETS, HANGERS, CLIPS, ANGLES, ANCHORS, STRAPS AND HARDWARE) IN CONTACT WITH PRESSURE <br />TREADED LUMBER, CONCRETE OR USED IN EXTERIOR CONDITIONS SHALL BE GALVANIZED WITH A RATING OF G-185, CONFORM TO <br />ASTM A653 AND WATER/CORROSION RESISTANT. METAL CONNECTORS MUST BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. <br />ALL METAL STRAPS MUST BE INSTALLED WITH EQUAL LENGTHS ABOUT THE JOINT LINE. USE SIMPSON STRONG -TIE CONNECTOR <br />PRODUCTS OR APPROVED EQUAL. <br />8. ALL NAILS, SCREWS AND BOLTS USED WITH PRESSURE TREATED LUMBER OR EXTERIOR CONDITIONS ARE TO BE HOT -DIPPED <br />GALVANIZED (OR STAINLESS STEEL) AND WATER/CORROSION RESISTANT. HOT -DIPPED GALVANIZED FASTENERS TO CONFORM TO <br />ASTM A153 CLASS D. ELECTROGALVANIZED FASTENERS SHALL HAVE A CLASS RATING PER ASTM B695 NO LESS THAN 55. TOE <br />NAILING WILL NOT BE PERMITTED. <br />A. NAILS SPECIFIED ARE TYPE: COMMON, FS FF-N-105. <br />B. BOLTS SPECIFIED ARE ASTM A307, GRADE A WITH ASTM A563 HEX NUTS AND FLAT WASHERS, UNLESS NOTED OTHERWISE. <br />9. ALUMINUM IS NOT TO BE USED IN DIRECT CONTACT WITH ACQ TREATED LUMBER. <br />10. CONNECTIONS AND FASTENERS SHALL BE PER FLORIDA BUILDING CODE, TABLE 2304.9.1 FASTENING SCHEDULE, UNLESS NOTED <br />OTHERWISE. <br />11. SHEATHING: <br />A. FLOOR: <br />USE 3/4" T&G APA 24oc STURD-I-FLOOR, EXP. 1, PLYWOOD (or OSB) SUB -FLOOR SHEATHING. FASTEN FLOOR SHEATHING <br />TO SUPPORTS WITH 10d COMMON NAILS AND CONSTRUCTION ADHESIVE. SPACE 10d COMMON NAILS AT 6" O.C. AT SHEATHING <br />EDGES AND 12" O.C. IN FIELD. SELECT CONSTRUCTION ADHESIVE WITH APA AFG 01 SPECIFICATION AND FOLLOW APA AND <br />MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. <br />B. WALL: (UNLESS NOTED OTHERWISE) <br />EXTERIOR FACE: Y2" (1%2") P.T. PLYWOOD, APA 24/16 RATED, FOR THE FIRST 4'-D" VERTICALLY. USE 2") EXTERIOR <br />GRADE PLYWOOD (or O.S.B.), APA 24/16 RATED, AT OTHER LOCATIONS. FASTEN SHEATHING TO SUPPORTS AS NOTED BELOW, <br />UNLESS NOTED DIFFERENTLY IN THE SHEAR WALL SCHEDULE: <br />ZONE 4 8d NAILS AT 6" O.C. AT SHEET EDGES AND 12" O.C. IN FIELD <br />ZONE 5 8d NAILS AT 6" O.C. AT SHEET EDGES AND 12" O.C. IN FIELD <br />* SEE WALL ELEVATION AT THE COMPONENTS AND CLADDING SCHEDULE FOR ZONE LOCATIONS. <br />INTERIOR FACE: %" GYPSUM WALLBOARD. FASTEN SHEATHING TO SUPPORTS WITH No. 8-2Y2" TYPE S or W, DRY WALL <br />SCREWS AT 7" O.C. AT ALL SUPPORTS, UNLESS NOTED DIFFERENTLY IN THE SHEAR WALL SCHEDULE, <br />C. ROOF: <br />%" EXTERIOR GRADE PLYWOOD (or O.S.B.), APA 24/16 RATED - EXPOSURE 1. FASTEN SHEATHING TO SUPPORTS AS NOTED <br />BELOW. PROVIDE ONE PLYWOOD CLIP PER SPAN BETWEEN SHEET EDGES. PROVIDE SOLID 2x BLOCKING BETWEEN SUPPORTS <br />AT ALL HIPS, RIDGES, VALLEYS, AND CHANGES IN ROOF SLOPE. <br />ZONE 1 8d NAILS AT 6" O.C. AT SHEET EDGES AND 12" O.C. IN FIELD <br />ZONE 2 8d NAILS AT 4" O.C. AT SHEET EDGES AND 12" O.C. IN FIELD <br />ZONE 3 8d NAILS AT 4" O.C. AT SHEET EDGES AND 12" O.C. IN FIELD <br />* SEE PLAN AT THE COMPONENTS AND CLADDING SCHEDULE FOR ZONE LOCATIONS. <br />D. USE 8'- 0" LONG X 4'-0" WIDE SHEETS WITH LENGTH ACROSS FRAMING, PERPENDICULAR TO FRAMING. STAGGER PANEL END <br />JOINTS 4'-0" TYPICAL. ALLOW 1/8" SPACE ALONG PANEL EDGES AND END JOINTS. <br />E. SEE FRAMING PLANS, SECTIONS, DETAILS AND SHEAR WALL SCHEDULE FOR SPECIAL CONDITIONS. <br />12. HOLES/ LEAD (PILOT) HOLES FOR: <br />BOLTS 1/32" TO 1/16" > BOLT DIAMETERS <br />LAG SCREWS - SHANK SAME DIAMETER AS SHANK <br />LAG SCREWS - THREADED PORTION + 507 OF DIAMETER <br />WOOD SCREWS - SHANK 7/8 DIAMETER OF SHANK <br />WOOD SCREWS - THREADED PORTION 7/8 OF DIAMETER <br />NAIL < 75% OF DIAMETER <br />13. ALL LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED GRADING AGENCY. <br />14. HEADERS AT NON BEARING CONDITIONS SHALL BE AS FOLLOWS: <br />OPENING SIZE HEADER <br />UP TO 4'-0" (2) 2x4 W/ }¢" SPACER or FLITCH PLATE <br />4'-0" TO 6'-0" (2) 2x6 W/" SPACER or FLITCH PLATE <br />6'-0" TO 9'-0" (2) 2x8 W/ Y2" SPACER or FLITCH PLATE <br />NAIL MEMBERS TOGETHER WITH 16d NAILS AT 8" O.C., STAGGERED. THREE (3) NAILS PER HEADER MINIMUM. <br />PREFABRICATED WOOD TRUSSES <br />1. FLOOR AND ROOF TRUSSES ARE TO BE DESIGNED FOR THE WOOD FABRICATOR BY A PROFESSIONAL SPECIALTY ENGINEER <br />REGISTERED IN THE STATE OF FLORIDA. SEALED CALCULATIONS AND LAYOUT DRAWINGS ARE TO BE SUBMITTED FOR APPROVAL. <br />TRUSS FABRICATOR TO PROVIDE ALL TRUSS -TO -TRUSS HANGERS AS REQUIRED TO RESIST GRAVITY AND UPLIFT REACTION. (UPLIFT <br />LOADING SHALL USE COMPONENTS & CLADDING WIND FORCES.) <br />2. WOOD TRUSSES SHALL BE BRACED AND ERECTED IN ACCORDANCE WITH THE LATEST EDITION OF THE BUILDING COMPONENT SAFETY <br />INFORMATION GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING, RESTRAINING & BRACING OF METAL PLATE CONNECTED WOOD <br />TRUSSES, JOINTLY PRODUCED BY WTCA AND TRUSS PLATE INSTITUTE. BRACING IN THE PLANE OF THE WEB MEMBERS: <br />A. THE TRUSS FABRICATOR SHALL PROVIDE AND LOCATE CONTINUOUS LATERAL BRACING FOR EACH TRUSS WEB MEMBER AS <br />REQUIRED. <br />B. LATERAL BRACING SHALL BE RESTRAINED BY DIAGONAL BRACING (MIN. 2" THICK NOMINAL LUMBER). THIS BRACING IS TO BE <br />CONTINUOUS. <br />C. A MINIMUM OF TWO ROWS OF DIAGONAL BRACING IS REQUIRED, ONE AT EACH VERTICAL WEB MEMBER CLOSEST TO BEARING <br />LOCATIONS. <br />3. THE BOTTOM CHORDS SHALL BE BRACED BY CONTINUOUS LATERAL BRACING SPACED AT 8'-0" ON CENTER WITH A CEILING <br />ATTACHED TO BOTTOM CHORD OF TRUSSES. IF NO CEILING IS ATTACHED TO BO7OM CHORD OF TRUSSES, BRACING SHALL BE <br />MINIMUM 2X4 0 36" ON CENTER NAILED TO THE TOP OF THE BOTTOM CHORD. DIAGONALS PLACED AT 45 DEGREES TO THE <br />LATERAL BRACES SHALL BE LOCATED AT EACH END. IF BUILDING EXCEEDS 60 FEET IN LENGTH, DIAGONAL BRACING SHOULD BE <br />REPEATED AT 20 FOOT INTERVALS. SEE TYPICAL TRUSS BOTTOM CHORD BRACING DETAIL. <br />4. TOP CHORD BRACING: <br />A. IF PLYWOOD DECKING IS APPLIED DIRECTLY TO TOP CHORD, PROPERLY LAPPED AND NAILED TO DEVELOP DIAPHRAGM ACTION, <br />BRACING IS NOT REQUIRED. <br />B. IF PURLINS ARE USED, DIAGONAL TOP CHORD BRACING IS REQUIRED AT EACH END. IF BUILDING EXCEEDS 60 FEET IN LENGTH, <br />DIAGONAL BRACING SHOULD BE REPEATED AT 20-FOOT INTERVALS. <br />5. DO NOT CUT, DRILL OR NOTCH ROOF TRUSSES WITHOUT WRITTEN APPROVAL FROM TRUSS ENGINEER. COORDINATE MECHANICAL, <br />ELECTRICAL, PLUMBING, ETC. SIZES AND LOCATIONS WITH TRUSS LAYOUT PRIOR TO ERECTION. <br />6. TRUSSES SHALL BE MANUFACTURED & DESIGNED IN ACCORDANCE WITH NATIONAL DESIGN SPECIFICATION(S) FOR WOOD <br />CONSTRUCTION, AF & PA, AND NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION, ANSI/TPI <br />1-1995, AND THE LOCAL CODE JURISDICTIONS. <br />7. DO NOT OVERLOAD FLOOR OR ROOF TRUSSES WITH BUILDING MATERIALS. <br />8. CONNECTOR PLATES SHALL BE MANUFACTURED BY A WTCA MEMBER PLATE SUPPLIER AND SHALL MEET OR EXCEED ASTM <br />A653/A653M REQUIREMENTS FOR STRUCTURAL STEEL. <br />9. IN ADDITION TO THE LOADS SHOWN IN THE DESIGN LOAD SCHEDULE, THE WOOD TRUSS MANUFACTURER SHALL DESIGN FOR THE <br />WEIGHT OF ALL MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT/FIXTURES AS WELL AS CHANDELIER FIXTURES, BAR CABINETS <br />AND ART WORK/MOBILES. <br />GUTHERMAN STRUCTURAL INC. <br />264 BUTTERCUP CIRCLE <br />ALTAMONTE SPRINGS FL 32-, <br />P: 407.701.o875 LIC. #28863 <br />1 V 6-r1 1 1 1a1 <br />STRUCTURAL <br />SIGNIFICANT REVISIONS HAVE BEEN MADE TO THIS <br />SHEET DUE TO THE CHANGE TO A WOOD FRAME <br />STRUCTURE AND ENCLOSING THE CORRIDORS. <br />1 <br />ROOF WIND PRESSURE (PSF) VAsD COMPONENTS AND <br />CLADDING <br />EFFECTIVE WIND <br />AREA (SO. FT.) <br />ROOF AREA <br />1 <br />2 <br />3 <br />10 <br />+13.08/-32.15 <br />+29.43/-53.95 <br />+29.43/-53.95 <br />20 <br />+12.26/-31.33 <br />+28.12/-48.21 <br />+28.12/-48.21 <br />50 <br />+11.17/-30,25 <br />+26.40/-40.62 <br />+26.40/-40.62 <br />100 <br />+10.35/-29.43 <br />+25.10/-34.88 <br />+25.10/-34.88 <br />OVERHANGS <br />- - - <br />+9.60/-46.32 <br />+9.60/-76.29 <br />NOTES: <br />1. WIND DESIGN PER FBC-2010 <br />2. +: INDICATES WIND PRESSURE <br />-: INDICATES WIND SUCTION <br />3. WALL DISTANCE A = 10.0 FT <br />(COMPONENTS AND CLADDING) <br />4. FOR EFFECTIVE WIND AREAS BETWEEN <br />THOSE GIVEN ABOVE THE LOAD MAY BE <br />INTERPOLATED, OTHERWISE USE THE <br />LOAD ASSOCIATED WITH THE LOWER <br />EFFECTIVE WIND AREA <br />DOOR do WINDOW WIND PRESSURE (PSF) Vasd <br />COMPONENTS AND CLADDING <br />EFFECTIVE WIND <br />AREA (SQ. FT) <br />10 <br />WALL AREA <br />4 <br />+29.43/-31.88 <br />5 <br />+29.43/-39.23 <br />20 <br />+28.12/-30.57 <br />+28.12/-36.63 <br />50 <br />+26.40/-28.85 <br />+26.40/-33.18 <br />100 <br />+25.10/-27.55 <br />+25.10/-30.57 <br />NOTES: <br />1. WIND DESIGN PER FBC-2010 <br />2. +: INDICATES WIND PRESSURE <br />-: INDICATES WIND SUCTION <br />3. WALL DISTANCE A = 10.0 FT <br />(COMPONENTS AND CLADDING) <br />4. FOR EFFECTIVE WIND AREAS BETWEEN THOSE <br />GIVEN ABOVE THE LOAD MAY BE INTERPOLATED, <br />OTHERWISE USE THE LOAD ASSOCIATED WITH <br />THE LOWER EFFECTIVE WIND AREA <br />P,'LMM214VVIA99I21 <br />WOOD HEADER SCHEDULE <br />MARK SIZE STUDS & HARDWARE EACH END <br />H1 <br />(2) 2x6 <br />1 JACK STUD / 1 KING STUD EACH <br />SIDE OF OPENING <br />H2 <br />(2) 2x8 <br />1 JACK STUD / 1 KING STUD EACH <br />SIDE OF OPENING <br />H3 <br />(2) 2x10 <br />1 JACK STUD / 1 KING STUD EACH <br />SIDE OF OPENING <br />H4 <br />(2) 2x12 <br />2 JACK STUD / 1 KING STUD EACH <br />SIDE OF OPENING <br />H5 <br />(3) 2x6 <br />1 JACK STUD / 1 KING STUD W/ (1) SIMPSON <br />CS20x2O" STRAP EACH END <br />H6 <br />(3) 2x8 <br />1 JACK STUD / 2 KING STUD W/ (1) SIMPSON <br />CS20x2O" STRAP EACH END <br />H7 <br />(3) 2x10 <br />2 JACK STUD / 2 KING STUD W/ (2) SIMPSON <br />CS20x2O" STRAP EACH END <br />H8 * <br />(2) 1 %" x 7Y4" <br />2 JACK STUD / 1 KING STUD EACH <br />LVL's <br />SIDE OF OPENING <br />H9 ** <br />(3) 1-Y4" x 7Y4" <br />2 JACK STUD / 2 KING STUD W/ (2) SIMPSON <br />LVL's <br />CS20x2O" STRAP EACH END <br />(2) 1%" x 11Y4" <br />3 JACK STUDS <br />H10 <br />LVL's <br />SEE SECTION 9/S4.01 <br />* HEADER TYPE "H8" CAN BE USED IN PLACE OF ANY 2-PLY 2x HEADER <br />** HEADER TYPE "H9" CAN BE USED IN PLACE OF ANY 3-PLY 2x HEADER <br />NOTE: <br />1 THE SPECIES AND GRADE FOR ALL 2x MEMBERS SHALL BE SOUTHERNPINE, No.2 or BETTER. <br />ALL WOOD USED AT THE EXTERIOR CONDITIONS SHALL BE PRESSURE TREATED, (P.T.) <br />2 JACK STUD INDICATES A BEARING STUD UNDER HEADER AND A CRIPPLE STUD ABOVE <br />HEADER. KING STUD INDICATES A FULL SIZE STUD SPANNING FROM SOLE PLATE UP TO THE <br />UNDER SIDE 'OF THE DOUBLE TOP PLATE AT THE TOP OF THE WALL. <br />3 NAIL 2-PLY 2x MEMBERS TOGETHER WITH (2) ROWS OF 16d NAILS AT 12" O.C. PROVIDE A <br />Y" FLITCH PLATE or SPACERS BETWEEN 2z S <br />4 NAIL 3-PLY .2x MEMBERS TOGETHER WITH (2) ROWS OF 16d NAILS AT 12" O.C., EACH FACE. <br />PROVIDE A Y" FLITCH PLATE or SPACERS BETWEEN 2x'S <br />5 LVL INDICATES AN ENGINEERED WOOD BEAM, LAMINATED VENEER LUMBER. SEE <br />MANUFACTURER'S INSTRUCTIONS FOR CONNECTING MULTIPLE PLY'S TOGETHER. <br />I <br />In <br />ARCHITECTURE • <br />INTERIOR DESIGN, <br />-C-r =j <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />00o oao <br />000 a00 <br />o0 <br />BE"NEFICIAL <br />COMMUNITIES <br />3550 S. Tamiami Trail Suite 301 Sarasota, FL 34239 <br />Zephyrhills, FL <br />William Thomas Domanski, P.E. <br />FL. REG. #76843 <br />SET DISTRIBUTIONS: <br />0 SHEET REVISIONS: <br />