My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Valley Oaks Cir
Zephyrhills
>
Building Department
>
Building Plans
>
Valley Oaks Cir
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 1:19:56 PM
Creation date
2/18/2025 4:06:39 PM
Metadata
Fields
Template:
Building Plans
Location
Valley Oaks Cir
Contractor
First Florida Bldg Corp
Building Plans - Permit #
10902-10910
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILDING TYPE- II ATTIC SPACE. A =BUILDING TYPE: 11 ATTIC SPACE. B E BUILDING TYPE: 11 ATTIC SPACE. C <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />1110 <br />SF <br />NFA regd (Attic Area / 150): <br />7.4 <br />SF <br />Total reqd ventilation area in SI (Net Free Area X 144): <br />1066 <br />SI <br />Upper portion regd (Total Reqd Vent Area X 50%): <br />533 <br />SI <br />Lower portion regd (Total Reqd Vent Area - Upper Portion): <br />533 <br />SI <br />PROVIDED NFA VENTILATION - UPPER <br />( 1 ) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />138 <br />S! <br />( 2) 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />420 <br />SI <br />Total Provided: <br />558 <br />SI <br />PROVIDED NFA VENTILATION - LOWER <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Area of soffit: <br />75 <br />LF <br />NFA of soffit material per LF: <br />5 <br />SI <br />Total NFA of soffit material used: <br />375 <br />S! <br />ADDITIONAL VENTILATION <br />MFR: Master EAC Model: 16"x8" Rectangular Vent <br />Number of vents to be used <br />3 Vents <br />NFA of additional soffit vents(ea): <br />65 <br />SI <br />Total NFA of additional soffit material used: <br />195 <br />SI <br />Total provided: 570 Si <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />1656 <br />SF <br />NFA reqd (Attic Area / 150): <br />11 <br />SF <br />Total reqd ventilation area in Si (Net Free Area X 144): <br />1584 <br />SI <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />792 <br />SI <br />Lower portion reqd (Total Reqd Vent Area - Upper Portion): <br />792 <br />Sl <br />PROVIDED NFA VENTILATION -UPPER <br />( 0) 4 Ft Tamco Off -Ridge Vents X 138 Sl/vent = <br />0 <br />SI <br />4) 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />840 <br />S! <br />Total Provided: <br />840 <br />SI <br />PROVIDED NFA VENTILATION - LOWER <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Area of soffit: 100 LF <br />NFA of soffit material per LF: 5 SI <br />Total NFA of soffit material used: 500 SI <br />ADDITIONAL VENTILATION <br />MFR: Pilaster EAC Model:16"x8" Rectangular Vent <br />Number of vents to be used 5 Vents <br />NFA of additional soffit vents(ea): 65 SI <br />Total NFA of additional soffit material used: 325 SI <br />Total provided: 825 SI <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />1080 SF <br />NFA reqd (Attic Area / 150): <br />7.2 SF <br />Total regd ventilation area in SI (Net Free Area X 144): <br />1037 SI <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />519 SI <br />Lower portion regd (Total Reqd Vent Area - Upper Portion): <br />519 SI <br />PROVIDED NFA VENTILATION - UPPER <br />(1 ) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />138 S! <br />(2) 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />420 SI <br />Total Provided: <br />558 SI <br />PROVIDED NFA VENTILATION - LOWER <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Area of soffit: <br />48 LF <br />NFA of soffit material per LF: <br />5 SI <br />Total NFA of soffit material used: <br />240 SI <br />ADDITIONAL VENTILATION <br />MFR: Master EAC Model:16"x8" Rectangular Vent <br />Number of vents to be used 5 Vents <br />NFA of additional soffit vents(ea): 65 SI <br />Total NFA of additional soffit material used: 325 SI <br />Total provided: 565 SI <br />® BUILDING TYPE: 11 ATTIC SPACE: D <br />0 BUILDING TYPE: 11 ATTIC SPACE: <br />E <br />® BUILDING TYPE: II ATTIC SPACE: <br />F <br />REQUIRED NFA VENTILATION <br />REQUIRED NFA VENTILATION <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />1388 <br />SF <br />Attic area (Including Soffit): <br />869 <br />SF <br />Attic area (Including Soffit): <br />1147 <br />SF <br />NFA reqd (Attic Area / 150): <br />9.3 <br />SF <br />NFA reqd (Attic Area / 150): <br />5.79 <br />SF <br />NFA regd (Attic Area / 150): <br />7.6 <br />SF <br />Total regd ventilation area in SI (Net Free Area X 144): <br />1340 <br />SI <br />Total regd ventilation area in SI (Net Free Area X 144): <br />834 <br />SI <br />Total reqd ventilation area in SI (Net Free Area X 144): <br />1101 <br />Si ` <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />670 <br />SI <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />417 <br />SI <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />550 <br />SI <br />Lower portion regd (Total Reqd Vent Area - Upper Portion): <br />670 <br />SI <br />Lower portion regd (Total Reqd Vent Area - Upper Portion): <br />417 <br />SI <br />Lower portion reqd (Total Reqd Vent Area - Upper Portion): <br />550 <br />S! <br />PROVIDED NFA VENTILATION - UPPER <br />PROVIDED NFA VENTILATION - UPPER <br />PROVIDED NFA VENTILATION - UPPER <br />( 2) 4 Ft Tamco Off -Ridge Vents X 138 Sllvent = <br />276 <br />SI <br />(2) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />276 <br />SI <br />( 1 ) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />138 <br />SI <br />( 2) 6 Ft Tamco Off. -Ridge Vents X 210 SI/vent = <br />420 <br />SI <br />(1) 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />210 <br />SI <br />( 2) 6 Ft Tamco Off -Ridge Vents X 210 Slivent = <br />420 <br />SI <br />Total Provided: <br />696 <br />S! <br />Total Provided: <br />486 <br />SI <br />Total Provided: <br />558 <br />SI <br />PROVIDED NFA VENTILATION - LOWER <br />PROVIDED NFA VENTILATION - LOWER <br />PROVIDED NFA VENTILATION - LOWER <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Area of soffit: <br />48 <br />LF <br />Area of soffit: <br />39 <br />LF <br />Area of soffit: <br />53 <br />LF <br />NFA of soffit material per LF: <br />5 <br />SI <br />NFA of soffit material per LF: <br />5 <br />SI <br />NFA of soffit material per LF: <br />5 <br />SI <br />Total NFA of soffit material used: <br />240 <br />SI <br />Total NFA of soffit material used: <br />195 <br />SI <br />Total NFA of soffit material used: <br />265 <br />SI ` <br />ADDITIONAL VENTILATION <br />ADDITIONAL VENTILATION <br />ADDITIONAL VENTILATION <br />MFR: Master EAC Model:16"x8" Rectangular Vent <br />MFR: Master EAC Model: 116"x8" Rectangular Vent <br />MFR: Master EAC Model:16"x8" Rectangular Vent <br />Number of vents to be used <br />7 Vents <br />Number of vents to be used <br />4Vents <br />Number of vents to be used <br />5Vents <br />NFA of additional soffit vents(ea): <br />65 <br />SI <br />NFA of additional soffit vents(ea): <br />65 <br />SI <br />NFA of additional soffit vents(ea): <br />65 <br />SI <br />Total NFA of additional soffit material used: <br />455 <br />SI <br />Total NFA of additional soffit material used: <br />260 <br />SI <br />Total NFA of additional soffit material used: <br />325 <br />S! <br />Total <br />695 <br />SI <br />/A' <br />Total <br />1 <br />provided: <br />provided: <br />455 <br />SI <br />Total provided: <br />590 <br />S! <br />® BUILDING TYPE: II ATTIC SPACE: G <br />BUILDING TYPE: II ATTIC SPACE: H <br />0 BUILDING TYPE: li ATTIC SPACE: <br />J <br />REQUIRED NFA VENTILATION <br />REQUIRED NFA VENTILATION <br />.� <br />REQUIRED NFA VENTILATION <br />Attic area (Including Soffit): ` <br />1028 <br />SF <br />Attic area (Including Soffit): <br />1551 <br />SF <br />Attic area (including Soffit): <br />90 <br />SF <br />NFA regd (Attic Area / 150): <br />6.8 <br />SF <br />NFA regd (Attic Area / 150): <br />10.3 <br />SF <br />NFA reqd (Attic Area / 150): <br />0.6 <br />SF <br />Total reqd ventilation area in S! (Net Free Area X 144): <br />986.9 <br />S! .' <br />Total reqd ventilation area in SI (Net Free Area X 144): <br />1489 <br />SI <br />Total reqd ventilation area in SI (Net Free Area X 144): <br />88 <br />S! <br />Upper portion regd (Total Reqd Vent Area X 50%): <br />493 <br />SI <br />Upper portion regd (Total Reqd Vent Area X 50%): <br />744 <br />SI <br />Upper portion reqd (Total Reqd Vent Area X 50%): <br />44 <br />SI <br />Lower portion reqd (Total Reqd Vent Area - Upper Portion): <br />493 <br />S! <br />Lower portion reqd (Total Reqd Vent Area - Upper Portion): <br />744 <br />SI <1 <br />Lower portion regd (Total Reqd Vent Area - Upper Portion): <br />44 <br />SI <br />PROVIDED NFA VENTILATION - UPPER <br />PROVIDED NFA VENTILATION - UPPER <br />PROVIDED NFA VENTILATION - UPPER <br />( 1 ) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />138 <br />SI <br />(1) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />138 <br />Si <br />(1) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent = <br />138 <br />SI <br />( 2) 6 Ft Tamco Off -Ridge Vents X 210 Sllvent = <br />420 <br />SI <br />( 3) 6 Ft Tamco Off -Ridge Vents X 210 Sllvent = <br />630 <br />SI <br />( 0) 6 Ft Tamco Off -Ridge Vents X 210 SI/vent = <br />0 <br />SI <br />Total Provided: <br />558 <br />SI <br />Total Provided: <br />768 <br />SI <br />Total Provided: <br />138 <br />S! <br />PROVIDED NFA VENTILATION - LOWER <br />PROVIDED NFA VENTILATION - LOWER <br />PROVIDED NFA VENTILATION -LOWER <br />MFR: Hardie Model: Perforated Cement Board Sci it <br />MFR: Hardie Model: Perforated Cement Board Soft <br />MFR: Hardie Model: Perforated Cement Board Soffit <br />Area of soffit: <br />30 <br />LF <br />Area of soffit: <br />56 <br />LF <br />Total soffit material to be used: <br />10 <br />LF <br />NFA of soffit material per LF: <br />5 <br />SI <br />NFA of soffit material per LF: <br />5 <br />SI <br />NFA of soffit material per LF: <br />5 / <br />LF <br />Total NFA of soffit material used: <br />150 <br />SI <br />Total NFA of soffit material used: <br />280 <br />SI <br />Total provided: <br />50 <br />SI <br />ADDITIONAL VENTILATION <br />ADDITIONAL VENTILATION <br />MFR: Master EAC Model:16"x8" Rectangular Vent <br />MFR: Master EAC Model:16"x8" Rectangular Vent <br />Number of vents to be used <br />6 Vents <br />Number of vents to be used <br />ElVents <br />NFA of additional soffit vents(ea): <br />65 <br />S! <br />NFA of additional soffit vents(ea): <br />65 <br />SI <br />Total NFA of additional soffit material used: <br />390 <br />Si <br />Total NFA of additional soffit material used: <br />520 <br />SI <br />Total provided: 1 <br />540 <br />SI <br />Total provided: 1 <br />800 <br />SI <br />CD <br />0) <br />n <br />U <br />Q <br />N <br />c•� <br />r <br />c+� <br />0 <br />CU <br />0 <br />N <br />N <br />N <br />W <br />0 <br />0 <br />a <br />3 <br />a <br />MATCHLINEI <br />!_API G <br />AREA AREA z AREA AREA`'. <br />"All tl�ll SJ ll�il a IIEll a <br />LL n_ U_ <br />o <br />AREA n AREA AREA AREA <br />"Bit „Doi "D", ,"G,l <br />Draft Barrier Area Diagram <br />Square F <br />es of Individual Areas Shown <br />Hill <br />AREA <br />"Fit r <br />t <br />t- <br />F <br />L <br />AREA c <br />"Hit <br />r,_'****P�arf�ialRoof Framing Plan - Building Type II <br />AREA <br />nnn <br />AREA <br />"D"1 <br />AREA <br />"Au <br />N.T.S. <br />® SHEET NOTES <br />A REFER TO SHEETS S4.02 FOR SHEAR WALL HOLD <br />DOWN DETAILS. <br />B REFER TO SHEET S4.00 FOR FRAMING GENERAL <br />NOTES <br />C SEE SHEET S4.02 FOR HEADER & BEAM SCHEDULE & <br />SUPPORTS <br />D UNIT NAMES REFLECT UNITS BELOW FRAMING <br />MEMBERS <br />® KEY NOTES <br />01 DRAFTSTOPPING, TYP,, DRAFTSTOPPING SHALL <br />COMPLY WITH FBC 717.3 AND FBC 717.4 REFER TO <br />WALL SECTIONS FOR DETAILS <br />02 22061-HR FIRE RATED ATTIC ACCESS W/ LOCK. <br />CONTRACTOR TO COORDINATE LOCATION <br />1 7 <br />I 03 OFF RIDGE VENT W/ INSECT SCREEN AS LISTED TO <br />MEET CODE <br />I'4 <br />04 22"06" SELF CLOSING DRAFT STOP ACCESS DOORS <br />0 <br />05 PREFAB WD ROOF TRUSSES AT MAX 24" OC ROOF <br />+� PITCH TO BE 5:12 LINO, W/ 16,OVERHANG UNO <br />I, <br />06 20" DEEP PREFAB WD FLOOR TRUSS AT 24" OC TYP <br />AT UNITS, UNO <br />° I 07 17" DEEP PREFAB WD TRUSS AT 24" OC TYP AT <br />' BREEZEWAY <br />I <br />- 08 PREFAB WOOD BALCONY TRUSS WITH SLOPED TOP <br />o CHORD AT 24" OC <br />I <br />I 09 FLOOR TRUSS TO HAVE ADDITIONAL DIAGONAL <br />I BRACES DUE TO SHEAR WALLS <br />10 ALUM GUTTERS &DOWNSPOUTS, TYP. <br />I <br />11 SW-1 SHALL STOP 1'-0" BEFORE ELECTRICAL METER <br />CENTER AND BEGIN 1'4" AFTER METER CENTER. <br />PROVIDE 2X6 WALL AT METER CENTER. CONTRACTOR <br />I TO COORDINATE LOCATIONS AND LENGTH OF METER <br />CENTER WALL <br />f4A, <br />12 (3) 2X4"# 2' S.Y.P. STUDS UNbE'R EACH S)iDE'OF'BEAM,. <br />(# `?IN BREEZEWAY WALL. NAIL WITH 16d @ 12" OC EACH <br />LY. PROVIDE CONTINUOUSLY TO FOUNDATION. <br />III <br />13 STEP UP IN ROOF TRUSS; REFER TO RCP AND <br />SECTIONS <br />�I <br />I I 14 ALL CORNERS MARKED (4 LOCATIONS): USE (2) 2X6 <br />I I; S.Y.P. #2 @ 16" O.C. (FASTEN PLIES WITH 10d @ 12" <br />1 O.C. STAGGERED) FOR ADISTANCE OF 7'-0" ALONG <br />W EACH INTERSECTING WALL OR UNTIL WALL ENDS <br />Z 15 ALIGN RIDGE WITH CORNER OF UNIT WALL <br />2 <br />16 20" DEEP PREFAB WD FLR .TRUSS AT 16" OC <br />1/8°'=1'-0" 17 CRICKET: COVER CRICKET FRAMING WITH <br />SELF -ADHERING MEMBRANE AND SHEET METAL. <br />PROVIDE METAL VALLEY FLASHINGS, SEE DETAILS <br />18 ROOF FRAMING: CONVENTIONAL FRAMED JOISTS @ <br />16" O.C. <br />= LEGEND <br />WALLS BELOW <br />INT. LOAD BRG. WALLS <br />SW-1 SHEAR WALLS, HOLD DOWNS = <br />-D D CONT. DRAFTSTOPPING <br />HEADER OR BEAM <br />- - PREFAB. WOOD TRUSS <br />r------ 7:1 <br />RATED ATTIC ACCESS DOOR <br />® 4' TAMCO OFF -RIDGE VENT <br />® 6' TAMCO OFF -RIDGE VENT <br />COLUMN REF. PER S4.02 <br />® KEY PLAN <br />ilM VA A <br />=_1111011 McLaen <br />11=111= ENGINEERING <br />sll=1ll ti'� GROUP <br />FL Cof.4 #7992 <br />5728 Major Blvd., Suite 603, Orlando, FL 32819 <br />Tel. (407) 354-5411 Fax (407) 354-3466 <br />Web Site: www.mgmclaren.conj�0%111111111, <br />fY�EN�� t <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE i INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fi 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Meetinghouse <br />at Zephyrhilis <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />SET DISTRIBUTIONS: <br />11/25/09 <br />_Progress Set <br />12109/09 <br />60% Progress Set <br />12M7/09 <br />Bid Set _ <br />03/02/10 <br />Permit Set <br />Q SHEET REVISIONS: <br />01125110 <br />1 Misc. Coordination <br />08125/10 <br />3 Misc. Coordination 3 <br />EDITED BY: G8 <br />PROJECT NO. 09-2587 <br />Building Type 11 <br />RoofFraming Plans <br />:u <br />Partial Roof ~lan - Buildin ype <br />r - I <br />-, -1 i r rFI--F-Tr i Ennl,r t If i;, i n -- i-��- 1 11 T. <br />1 /8"=1'-0" <br />®OVAL- r\\a <br />R.F. Ole c J I Mt W 2514 <br />S4.23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.