GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed L/180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7_ 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10, Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12, Lintels loaded simultaneously with vertical (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load Applied horizontal load / . O <br />Safe vertical load + Safe horizontal load `— <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />8F44 1 B/1 T 8F40 1 B/1 T 8RF40 OB/l T 8F321 B/lT <br />I <br />FORM & GROUT SOLID <br />it <br />••:4. <br />O � W <br />U <br />O 7Z #5 BAR CONT. <br />8F 12-1 B/1 T <br />O <br />"V" LINTEL DETAIL <br />SCALE = N.T.S. <br />I <br />9 <br />MIMI <br />F = FILLED WITH <br />GROUT / U <br />= UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />Q <br />6 F 16— <br />B/ 1 T <br />V <br />ib <br />tNOMINAL. <br />QUANTITY OF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL <br />HEIGHT <br />MATERIALS <br />cT c precastTimels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CM U) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />2x8 #2 SYP STUDS @ 8" O.C. W/ (2) USP OR <br />SIMPSON MSTAM36 STRAPS EACH STUD ((1) <br />STRAPS EACH SIDE) CENTERED W/ (13) 10d <br />NAILS & (8) Y4"x1 a' TAPCONS OR TITENS <br />-CENTER OF STRAP @ T/WALL TYP. U.N.O. <br />2x8 #2 SYP P.T. BASE PLATE <br />W/ 12" EPDXY ANCHOR OR Y2" <br />J BOLT W/ MIN. 7" EMBEDMENT @ <br />32" O.C. & 6" FROM EACH END <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />Ot SEE PLAN <br />II — T�/WALL <br />I L1^ <br />8" KNOCKOUT COURSE <br />W/ (1) #5 CONT. <br />SEE PLAN FOR FILLED CELL <br />SPACING <br />WALL SPLICE DETAIL <br />REVISED: 11/04/19 SCALE: 1" = 1'-0" <br />CD <br />8'-0" LL <br />0 <br />4'-6" LL <br />#5 REBAR <br />MIN..(1)REQD <br />' <br />(i) <br />CL AR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />4 ° <br />A a <br />d <br />.0—C.M.U. <br />#5REBAR ATTOP <br />a ° a <br />GROUT <br />MIN. (1) REQ'D <br />1-1/2" CLEAR <br />0 a a <br />d <br />a <br />° <br />E <br />5 REBAR AT <br />= CO w <br />a <br />BOTTOM OF <br />CL n z W <br />W O � <br />4'-6" LL <br />o <br />LINTEL CAVITY <br />0 U UI) <br />Lu <br />-BOTTOM <br />REINFORCING <br />PROVIDED IN <br />LINTEL <br />0 Ir Ci O <br />C ¢ C7 c <br />O - O W ;n <br />Z _' b 3 'D <br />#5 REBAR AT BOTTOM <br />7-5/8"ACTUAL <br />' NOMINAL WIDTH <br />(VARIES) <br />vi ¢ a <br />AS INDICATED <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION ""ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />(DMIN. <br />5'-8" LL <br />(D O <br />13'-0" LL 5'-10" LL <br />E <br />MIN. <br />17'-4" LL <br />LINTEL PLAN - ELEV-A <br />SCALE: Y4'=1'-O" <br />CC7 <br />iw <br />un _ <br />� <br />Q C2 <br />c rota <br />us rosy <br />v, ywct <br />co <br />r- <br />i". '' ••' <br />Kv � <br />C- <br />CP <br />CV <br />0 <br />CV <br />ti <br />CV <br />M <br />o•NO <br />y,;"�s <br />m <br />•y7:i'3C:110 I <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />to <br />W E <br />1- o co o8 <br />a om <br />NC <br />Q 3 to W <br />Lo <br />U) (n (h rZ t11 <br />LL W <br />Q N M V <br />m�LL <br />J <br />13�_ <br />W° d <br />o uYi Z <br />0 <br />s <br />c-' O <br />g <br />0 Y p <br />W :3 '(5 C"! <br />W <br />1 og� <br />p <br />m f Q <br />Icem <br />U5 <br />0 <br />I <br />Z N m Z <br />cc IL <br />W <br />G H <br />Z <br />U <br />U <br />Z <br />❑❑❑ <br />Blow, W <br />Z N c3 <br />0 00 <br />Z � � <br />Q <br />d N <br />v> <br />z <br />�-1 <br />o <br />04-1 <br />� rn <br />w <br />0 U <br />Og <br />w o <br />N w <br />cn <br />w � <br />— <br />L <br />f.. <br />�l U <br />Wco <br />®® <br />co <br />M <br />M <br />¢ <br />Z <br />.i <br />LL <br />E° <br />Zo <br />Qo <br />wZZ® <br />s >9 <br />Q <br />oa <br />Eo� <br />do <br />0< <br />0, <br />Ez <br />d L <br />ao <br />p <br />1� <br /><o <br />m� <br />o, <br />p� <br />.m <br />ZF <br />Z <br />m <br />F y <br />aW <br />� Z <br />o� <br />- I; <br />) <br />m <br />�� <br />- <br />s <br />wa <br />1:1 <br />ZI4 <br />0 O <br />0 <br />= <br />>M <br />O <br />d' <br />m <br />CU <br />CU <br />0 <br />N <br />L <br />CY) <br />co <br />C\1 <br />C:) <br />Q <br />O <br />U) mco <br />N <br />LO <br />�. <br />ca M <br />o <br />o <br />o o <br />� <br />N <br />Q C <br />r <br />M N <br />coy <br />o <br />Z <br />cc <br />Z <br />� M <br />E N N <br />2 <br />E <br />JOB <br />NO: 23-00502 <br />SCALE : AS NOTED <br />SHEET NO. <br />7 <br />