THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />- ti <br />� Imo........... <br />I................ \...i �9�..LL.....' <br />16GAx1-1\2" LONG (3/4"-1" CROWN) S� I <br />STAPLES @ 6" O.C. VERT BETWEEN MAX I 16GAx1-1/2" LONG (3/4"-1" <br />STUDS (NOTED THUS:—) - OFFSET N <br />CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O 0 0 <br />5'-0" a - <br />c� <br />STUB -OUT FOR 1'-0" o 0 0 <br />GAS METER 0 <br />rf U <br />C O <br />N = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />F-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" <br />5000s 1,8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.811.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />60 2.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />r <br />1/8" gap <br />k <br />FILL CELL <br />STD, 900 HOOK BOND BEAM <br />U) <br />w <br />11 <br />STD. 90° <br />CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />BAR <br />#5 CONT. <br />FROM <br />US <br />HIGHEST TOT <br />— <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND <br />j <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION <br />a@ INT. BRG. WALL <br />N.T.S. <br />1/8"min. } Small gap 2" min. <br />2" max <br />4 max. <br />I <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8"gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2 mirr. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x :CONTRA TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING)/8" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pif max along load bearing wall. <br />Load bearing wall must stack <br />"Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES--� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or_tz <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series De th End Intermediate <br />® <br />BC15000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-718" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />IBC16000so <br />BC16500S R <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s®5-16d <br />11-7/8" <br />3-16d <br />3-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />5/8" � <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />�Y/ Provide adequate bearing Use 10dx3" nails at Vo.c. for all joist <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />lodnails . <br />SECTION @INT. BRG. WALL require additional consideration.— <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(See table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />tto ❑ ro <br />6" A 1%" ROUND HOLE MAY 6" 1 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1%" <br />THE WEB. PROVIDE AT A ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) — <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM a <br />a . a.. <br />° <br />Joist hanger SEE PLAN FOR a• ..Q .. •, <br />I ' FOUNDATION INFO a' <br />STEM FOUNDATION <br />Filler block. <br />� Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />L requirements <br />-0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />REINF. SEE PLAN <br />a (2) #5 REBAR <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />.�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" v <br />CENTERED @ PIPE <br />PENETRATION <br />3 a <br />4 <br />i�=l i ° • <br />1 �I�I=I® : �: <br />I 1I1�ITi__ <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />d <br />`=— SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE_\ <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />Z • c <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a a ° <br />41. <br />.. <br />I I I®I I I —I a I- <br />j—i 11— a 4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />CNJ <br />00 <br />- <br />C4 <br />CV <br />N <br />0 <br />0•'• t E .y y <br />• �;:. <br />r'r«€EffbTxE�Z. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and <br />9 9 <br />seal is only for <br />Y <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />V <br />4 <br />o cm <br />o <br />N m v <br />C,N <br />0 7 to <br />LL LL <br />U? �M0� <br />LL ui <br />tL a <br />� <br />�' <br />W <br />a u z <br />z <br />0o <br />m�� <br />0 <br />0 0 <br />19 j N (4 <br />m J Q <br />cc <br />W� C c� <br />I_Z <br />o <br />N M Z <br />10� o w <br />U p <br />O U <br />I'_z <br />❑�� <br />W <br />V M � <br />CMV M <br />o g <br />z <br />� o <br />¢ Q <br />M <br />L11Cz <br />Lu <br />U _ C5 <br />O <br />t!? � <br />y oLn <br />wss <br />.) <br />U <br />J <br />a _ E <br />IRSL1J <br />L 8 <br />Iy ... <br />U O 35 <br />MEIMI��r � d <br />N 01� <br />° <br />o <br />C <br />w <br />M <br />�< <br />O <br />g <br />u_ <br />c E <br />CL <br />E ® <br />o <br />o � <br />Q� <br />" <br />❑� <br />F— r0 <br />Q? <br />oo <br />XU <br />o 0 <br />�U <br />O Ea <br />G <br />p Q <br />a <br />wo <br />ww <br />r <br />.) ru <br />ao <br />mo <br />�Z <br />CD <br />a <br />T <br />m <br />< g <br />40 <br />ao <br />�w <br />= F <br />O <br />az <br />W F <br />F- <br />3 <br />a o <br />mi <br />O <br />J <br />LO <br />LO <br />rn <br />m <br />^` <br />Q <br />~ <br />170 <br />C) <br />D <br />d. <br />O <br />O <br />T— <br />76 <br />U) O <br />CN <br />m <br />m 2 <br />, /� <br />V <br />C0 <br />C) <br />LoI <br />-0 LL <br />LO C) <br />L n <br />III <br />CD <br />CV <br />Q M O <br />CD <br />T— <br />a� <br />z <br />M r <br />' M � M <br />o <br />Z <br />E 0 cn <br />E <br />cc <br />E <br />co <br />C <br />a <br />c� � ¢ <br />JOB <br />NO: 23-02469 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />i'i nI I I III i,Ii 1 11 u,,ii.: r 1 11 1 1 li I --- T--Fi — lii r <br />