My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36374 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36374 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 2:47:00 PM
Creation date
2/18/2025 4:11:26 PM
Metadata
Fields
Template:
Building Plans
Street #
36374
Location
Garden Wall Way
Contractor
Lennar
Building Plans - Permit #
5684
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CROSS BRACING DETAIL (TYP.) 1 <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONY. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. Cg <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. DB <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP, HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 74' O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />3 <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />MAX &EACH END ALTERNATE A CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. ---, <br />-/—WOOD TRUSS — <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />EXTEND <br />SLAB 1 1/2" <br />7—(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />-_. <br />_ ZV Z <br />' r <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGOP <br />AT 8'-0" <br />MAX <br />2X4 CONT. AT <br />T & B CHORD <br />TRUSS <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />„ 2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"O.C, MAX, w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />CONC.MASONRY <br />STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL a� INTERIOR BEARING 3 <br />SCALE: N.T.S. <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />2" <br />w <br />z U <br />PORCH SLAB SEE a N <br />FOUNDATION PLAN _i W <br />e° z <br />° ° ° <br />(2) #5's CONT. T&B -- <br />W/ #3 STIRRUPS AT N z <br />4'4' WHEN DEPTH !- ` <br />EXCEEDS 30" _ a LOWER OR <br />GARAGE SLAB <br />V41 SEE PLAN <br />LARGE STEP DOWN rl7 <br />SCALE: N.T.S. <br />2x4 STUDS w/ SIMPSON <br />SP1 w/ (10) 10d NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP,BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�7A TRUSS <br />WOOD POST. SEE FLR__T <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />PLAN <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />AN VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />EXTEND TRUSS OR <br />SLAB 1 1/2" ROOF SYSTEM <br />(2) #5's CONT. T&B w/ <br />_- #3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE - WHEN DEPTH <br />✓7 <br />K FOUNDATION PLAN - EXCEEDS 30'GRADE S H EAR TRAN S F E R <br />HIP = - — <br />USSES a ° <br />1 <br />... <br />00 <br />G.T - a r EXTERIOR. WALL r7 'N� <br />° SCALE: N.T.S. <br />1 -4 ° <br />(2) 12D NAILS — <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />z <br />O <br />Q <br />w <br />J <br />W <br />W <br />W <br />U) <br />2 ENTRY PORCH SILLrl 4 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />O FOR COLUMN INFO <br />WOOD OR MASONRY I <br />INTEGRATE MASONRY <br />ABOVE MASONRY <br />KNEEWALL INTO CMU BASE OR <br />PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF <br />PLAN FOR COLUMN <br />I <br />REQUIRED <br />INFO <br />1 i MASONRY KNEE WALL MAX 3 <br />1 <br />1 COURSES w/ TOP K.O. COURSE <br />CMU BASE W/ (1) #5 1 <br />W/ (1) #5 CONT. FILLED CELL <br />VERTICAL EACH <br />1 REQ'D @ MID SPAN MAX 6'-8" <br />CORNER FILLED 1 <br />�c <br />1 MAX 3 <br />SOLID. SEE ELEV. <br />j <br />1 1 <br />rT--- — <br />------- <br />1 <br />1 <br />1 , <br />1 <br />1 <br />I <br />, <br />, <br />COURSE FOR BASE SIZE <br />(3) #5's EA. WAY 1 1 <br />1 1 <br />1 i <br />-- --- x—`- --X-a I <br />0 i • 00 <br />- 11 57 <br />PORCH SLAB SEEAk -- <br />li ° <br />SLAB <br />LEVEL FOUNDATION PLAN -_ <br />(2) #5's CONT T&B w/ = z <br />CONTRACTOR TO INSTALL SEE CUT #3 STIRRUPS AT 4'-0" --I_ ° - - T <br />MIN 3" x 3" WEEP HOLE SECTION FOR WHEN DEPTH <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30" <br />11-411 <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL 16 <br />SCALE: N.T.S. <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />#5 REBAR CONT <br />@ SLAB LEVEL <br />EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O,C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: 1/2" <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />SIMPSON LSTA18 <br />W/ (12) 10d NAILS — SIMPSON HUC410 w/ (14 _ - — - I SEE PLAN <br />CENTERED AT I I 16d INTO HEADER & 6 ) I I I FOR CANT. TRUSS/ <br />SPLIT TO TIE I I O I t <br />10d INTO BEAM - SEE <br />BEAMS TOGETHER I I I I I OP Wp <br />I ROOF PLAN FOR MORE <br />I INFO I EE PLAT <br />' %2' CDX PLYWOOD OR %6" O.S.B. MIN, (2) 2x8 #2 SYP <br />I I SEE FLOOR PLAN FOR I SHEATHING REQ'D FROM BOTTOM <br />COLUMN SIZE & BASE I I I —7/16" OSB FLITCH PLATE HEADER. SEE Q/S4 FOR <br />SEE FLOOR PLAN i CONNECTION INFO I I REQ'D ONLY WHEN OF WALL TO ROOF SHEATHING REQ'D CONNECTIONS <br />FOR COLUMNS ZE L _ — _ _ _ L _ _ _ _ _ _ _I L _ _ _ — — —+ _ INDICATED ON BM. ABOVE W/ 8d NAILS @ 4" O.C. I N <br />ADDITIONAL INFO. _ — — — SCHEDULE/PLAN FIELD, EDGES & BOUNDARIES <br />7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR <br />REQ'D ONLY WHEN COLUMN SIZE & BASE 2X4 #2 SPF STUDS @ <br />OPTION A SC INDICATON ED <br />OPTION B CONNECTION INFO OPTION C. @ O.C. W/ USP S@ <br />@ BASE & SPT24 @ <br />TOP <br />COMMON BM TO POST ATTACHMENT <br />EXTERIOR SHEATHING /4 <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION a� FLOOR <br />CONNECTION 22 <br />SCALE: N.T.S. <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />SIMPSON (2) HTS20 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />I <br />0 ' <br />CORNER SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />BM. SPLICE OVER <br />CL f CENTER OF POST <br />MIDDLE <br />SEE PLAN MAX. <br />24" STEPS — <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />GARAGE OR <br />LOWER SLAB <br />SEE PLAN <br />SECTION <br />SCALE: N.T.S. <br />2X4 #2 SYP P.T. PLATE W/ <br />V EPDXY ANCHOR OR <br />J-BOLT OR X" TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />MIN, 6" EMBEDMENT I <br />G, y <br />MAIN HOUSE <br />SLAB <br />(2) #5's CONT. T&B <br />W/ #3 STIRRUPS AT <br />4'-0" WHEN DEPTH <br />EXCEEDS 30" <br />GARAGE MONO 21 <br />C" <br />T7 »r <br />ISMS <br />o, <br />A >r <br />7- <br />as y a7 ra <br />'Z <br />E <br />�N\N�1 01vv/v �zz <br />� <br />W � • \v� A,, N <br />'t <br />a <br />- <br />F t.Oil- � <br />o•`. <br />'••.....e <br />. <br />��y�Rop c- 10 \`�� <br />S S ,` <br />TO the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />w 'tE <br />a 8 <br />0 <br />N r <br />c ° <br />615 � � U�1co <br />0-- <br />0 <br />ajN0 <br />Q o U_ L L <br />a LL W <br />uj <br />. Q7 0_ <br />13 <br />CIL <br />z_ <br />= O <br />r O <br />N (p O <br />O <br />LU v�Mc oo <br />N C7 Q <br />Z N do U O <br />❑❑ <br />M r <br />Z N m <br />o� <br />oo <br />� o <br />Wn <br />M <br />.o <br />v <br />— <br />o Lu s <br />N <br />.) <br />Oft <br />ca 6 <br />r-- u�� <br />a 09 <br />t <br />v <br />o <br />o <br />w <br />M <br />0! <br />�z <br />o S <br />z <br />LL, <br />ca E <br />0wz <br />zo <br />fl <br />oLL <br />>q <br />a� <br />Z© <br />❑a <br />F� <br />O <br />zo <br />U <br />¢o <br />o8 <br />p <br />a <br />cV <br />a o <br />rw <br />C/) <br />o� <br />m o <br />Io <br />oz� <br />- WC <br />N <br />gym, <br />J <br />C <br />�w <br />oa <br />2N <br />Zo <br />az <br />N <br />p- SS <br />w ii <br />v, w <br />oii <br />r� <br />cD <br />to <br />�¢w <br />o� <br />ZI< <br />U <br />0 <br />.2 O <br />12 <br />Lo <br />Om <br />m <br />� <br />M <br />CO <br />O <br />CD <br />Q <br />O <br />V <br />0 <br />N <br />c <br />LO <br />�-' <br />v <br />7_ <br />� <br />co N <br />O <br />n N <br />to <br />r <br />QcoLO <br />r <br />6 <br />M N <br />M <br />o <br />z <br />M <br />z <br />z N ,— <br />O <br />c <br />E <br />t� °� <br />r= <br />a <br />¢ o <br />JOB <br />NO: 22-12352 <br />SCALE: AS NOTED <br />SHEEP NO. <br />D1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.