Laserfiche WebLink
3/4" PLYWOOD <br />DECKING--, <br />FLOOR <br />SYSTEI <br />SIN <br />•-!N <br />T <br />CONT, HANDRAIL <br />RETURN TO <br />-WALL DETAIL <br />SCALE: NTS <br />MIN. (3) 2x STI <br />@ END OF LA'. <br />BELOW HDR. <br />STANDARD( <br />STRINGERS <br />SIMPSON A3 <br />MP34 CLIP Ti <br />FLOOR SYSI <br />LANDING FIR, <br />(2) 2x H <br />REQ'D ( <br />LANDIN <br />STRINC <br />CONNE <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS W/ 3/4" NOSING <br />42" KNEE WALL WITH <br />1x8 CAP & CASING <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />16 ` <br />15 36" H. CONT. <br />14\`, GRASPABLE , <br />13 ` © RAILING <br />CY) <br />12 \ j <br />\ I <br />11 10If 1 <br />~01 I <br />� I <br />1 x TR EAD 10 <br />LoIf�o <br />(TYP.) 9 ► 00 <br />= I r <br />STORAGE 8 <br />UNDER 7 <br />STAIRS 6 ` I <br />2x FRAMED 5\` <br />WALL <br />4 <br />1x RISERS <br />71 (TYP.) 3 <br />2 <br />2x FRAMED (3) 2x12 <br />WALL STRINGERS <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)- 1/4"x 3 1/2" TAPCONS @ <br />16"o.e. AND 3" FROM EA. END. <br />TYP. STAIR SECTION <br />SCALE: 1/2" = V-0" <br />L SEE PLAN FOR LANDING DEPTH <br />1 <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1 /4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />42" KNEE <br />WALL WITH <br />1 x8 CAP & <br />CASING <br />0 <br />1 x8 CAP & <br />CASING <br />9 <br />M <br />v <br />0 <br />in <br />1 <br />TYP. @ D2 <br />CORNERS <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />TUB/ SHWR <br />TILE TO 7' <br />A.F.F. <br />H1 k <br />N <br />DRYER VENT <br />THRU SIDE WALL- <br />) <br />J <br />X <br />N <br />HANSON BOX <br />@ 36" A.F.F.--/ <br />T WIRE SHELF <br />a, @ +54" A.F.F.. <br />©1 <br />TYP. <br />U.N.O. <br />&D2 <br />--- <br />Sim. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />1anr <br />RFV in 12n CAR <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />M>9'-01" <br />2x6 <br />SYP #2 <br />16" O.C. <br />WHEN THE TOP OF WALL IS GREATER THAN 9'-9% THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.* <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS- <br />1 1 25'-0" <br />I I <br />I 1 <br />I H1 1 <br />1 <br />I (L-­1 <br />6CA <br />2 <br />25 H <br />I 60" X 36" <br />SHOWER <br />FIBERGLASS <br />goo <br />W1111, <br />. <br />f <br />I� <br />TECH CENTER <br />7'-9" I. 5-11" <br />j 5068 BF I r I r rl <br />D. AU N 1 12114114 <br />( ' I0" FLAT CLGo <br />TILE <br />I3'-11" T- 10" 5'-11" <br />W. <br />00 <br />CD <br />7,17 N <br />* <br />H1 <br />0ED <br />J 3 B <br />TYP. S6 <br />U.N.O. 25 H <br />EGRESS* <br />OWNER'S <br />SUITE <br />8'-0" FLAT CLG. <br />CARPET <br />- G.T. - 0 - <br />BEDROOM 4 <br />8'-0" FLAT CLG. <br />CARPET <br />0 <br />�-1/2 WALL OR <br />RAILING PER SPECS <br />2668 11'4" <br />'cf <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 114 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91 /4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1!2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />"* SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />EXTERIOR WALLS <br />WWII <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />J <br />S6 <br />TYP. <br />U.N.O. <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE"C' <br />+29.7 / -32.2B <br />+29.7 / -39.7 <br />+28.3 / -30.8 <br />+28.3 / -37.0 <br />+26.6 / -29.1 <br />+26.6 / -33.5 <br />GC� <br />SEE SN SHEET SEE SN SHEET <br />1 �.Q MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18' X 25 � <br />S.H. <br />13 <br />20 X 38 3 <br />18' X 37 4 <br />S.H. <br />14 <br />20 X 50 a <br />181 X 50 <br />S.H. <br />15 <br />20X63 <br />181X62' <br />S.H. <br />16 <br />20X72 <br />182X71 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 z <br />S.H. <br />11-13 <br />271/4X388 <br />26x374 <br />S.H. <br />1 H4 <br />27 a X 50 s <br />26 x 50 <br />S.H. <br />11-15 <br />274X63 <br />26X621/2 <br />S.H. <br />1H6 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />374X26 <br />361X251/2 <br />S.H. <br />23 <br />37 a X 38 � <br />36 2 X 37 3/4 <br />S.H. <br />24 <br />37 4 X 501 <br />36 2' X 50 <br />S.H. <br />25 <br />37 4 X 63 <br />36 2 X 62 112 <br />S.H. <br />26 <br />37 4 X 72 <br />36 z X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 1 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 1 X 25 z <br />S.H. <br />33 <br />54 X 38 g <br />52 � X 37 4 <br />S.H. <br />34 <br />54 X 50 5 <br />521 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 X 71 z <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H, <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches, The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shail not exceed the smallest nosing <br />projection by more than 318 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />ITT-I-T-I�I MASONRY HGT. @ 8'-8 A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST LIVING 728 S.F. <br />SECOND LIVING 1036 S.F. <br />TOTAL LIVING 1764 S.F. <br />LANAI 60 S.F. <br />GARAGE 379 S.F. <br />ENTRY 62 S.F. <br />TOTAL SQ. FT. 2265 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN -A <br />SCALE: Y4"=V-0" <br />� <br />ev <br />a <br />cu -es <br />® <br />LLI <br />C M fJ N <br />LL_ <br />- <br />- <br />Q ' N �C <br />at <br />ru <br />'5 <br />M <br />40 <br />c.� <br />rr <br />°ASE <br />o <br />`( T <br />Q. <br />�'�ia/ pl4't I l d l tl't�\11'►�,` <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />W <br />d E <br />0(0 <br />0) <br />(1)^I­a <br />id <br />M v LL <br />V- <br />J ll. CL <br />Z <br />s m9 _ <br />W <br />_ N o <br />0 <br />0 <br />UM- <br />T m <br />N M Z H <br />Z <br />- <br />O U 00 <br />W <br />❑ ❑ <br />cn <br />M � <br />Z N <br />O <br />N <br />o� <br /><s : <br />ti <br />Z <br />QA <br />a <br />V <br />0UJoMA <br />1N <br />' <br />;t <br />�y N <br />( <br />u <br />W_ <br />A .....,.. <br />E <br />e aUP 8 <br />I <br />ZZ0 <br />i 'I >il Ylr 4gi <br />0 <br />4p <br />o <br />Cl) <br />w <br />Z <br />Zd <br />ro <br />o <br />� <br />c6- E <br />o <br />o° <br />Z® <br />(O <br />OX. <br />U O <br />O <br />a" <br />¢z <br />ttZ <br />wz <br />CV <br />o <br />¢ <br />w <br />L <br />ra <br />C <br />^ N <br />a <br />z <br />OY <br />m o <br />O� <br />cis J <br />m <br />M Z <br />s� <br />0 <br />wLL <br />o <br />g <br />a <br />ci <br />�� <br />mw <br />o <br />w� <br />>o <br />� <br />� <br />zd <br />a= <br />RC) <br />m <br />c` <br />c� <br />� <br />M <br />� <br />a <br />O <br />O <br />� <br />n <br />0 <br />`. i U <br />V <br />LO <br />%%�Oo <br />0 <br />r''\ <br />CV) <br />co N <br />p <br />r N <br />Lo <br />r <br />Q <br />C <br />r <br />,_ <br />M <br />CM <br />iri N <br />o <br />Z <br />Z <br />E 0 <br />m ,- <br />c <br />0 <br />E <br />U 0 <br />a � <br />Q 4 <br />c <br />JOB <br />NO: <br />22-12352 <br />SCALE: <br />AS NOTED <br />SHEET NO. <br />1.2 <br />