My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36379 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36379 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 3:15:32 PM
Creation date
2/18/2025 4:11:46 PM
Metadata
Fields
Template:
Building Plans
Street #
36379
Location
Flats St
Contractor
Lennar Home
Building Plans - Permit #
6065
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3, Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed L/180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load / ° 0 <br />Safe vertical load Safe horizontal load `- <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALfTY, LOTTS <br />i <br />8F44 1 B/1 T 8F40 1 B/1 T 8RF40 0B/1T 8F32 1 B/1T <br />FORM dr GROUT SOLID <br />O N W <br />J <br />U <br />O f5 BAR CONT. <br />8F12-1 B/1T <br />O <br />V' LINTEL DETAIL <br />SCALE = N.T.S. <br />TYPE DESIGNATION <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />J <br />w <br />8 '16 B/ 1 T <br />to <br />to <br />Z <br />i�s <br />tNOMINAL. <br />QUANTITYOF <br />WIDTH #5 REBAR AT <br />TOP <br />NOMINAL <br />° <br />HEIGHT <br />MATERIALS <br />cT T precasTTintels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5 REBAR AT TOP <br />MIN. (1) RECI'D <br />G a ILEAR <br />1/2" <br />O <br />d <br />a <br />G .M.U. <br />a° <br />° <br />GROUT <br />L04 <br />5 REBAR AT <br />BOTTOM OF <br />LINTEL CAVITY <br />-BOTTOM <br />REINFORCING <br />7-5/8"ACTUAL <br />PROVIDED IN <br />NOMINAL WIDTH <br />LINTEL <br />(VARIES) <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />ALTERNATE POWERS <br />STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) RECI'D 1-112" CLEAR <br />J <br />U) rn Y <br />J <br />'29 <br />wwO <br />C.M.U. <br />r -J <br />w <br />OEUOZ <br />COIE <br />6 C7 <br />Q J <br />0 LL O W <br />CJ � <br />#5 REBAR AT B( <br />U) U)¢ 0.N <br />AS INDICATED <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturers specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />4'-6" LL 4'-6" LL <br />�EI <br />5'-10" LL <br />LINTEL PLAN - ELEV-131 <br />SCALE: %4"=V-0" <br />ces <br />Cal <br />a> <br />7 W <br />CD <br />1= IV V N <br />w+ is 4= <br />N N <br />CM �, o <br />Q r N Ic <br />N y <br />is .3 <br />� css <br />is y cu <br />� c a <br />na <br />_E <br />i= <br />M <br />0 <br />CIO <br />O <br />M <br />O <br />`,CCltlla:Z�f�?{ <br />r .. L <br />,�, JAI <br />�b`�`,` � •_�^� <br />+. 3:-, i.. <br />_ <br />. .� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />W '- Eo S N <br />Q U 1- v <br />O N - <br />0 J <br />w w <br />to M v d a <br />,^ J LL <br />: O <br />V 30 <br />13- <br />, <br />Z m0 <br />L d o O o <br />a' <br />og�a, ¢ Co <br />W to <br />o <br />Z U�2 <br />o <br />Z :c <br />ILW <br />ry C0 p h <br />0 o d <br />Z ❑❑❑ <br />W <br />Cl) <br />Z N m <br />o � <br />Z <br />J Q <br />U) r <br />N^ Z <br />0 <br />W o <br />4-1 <br />(� w m <br />� m <br />U <br />O w o <br />fn r_ <br />U) <br />w m <br />I1 <br />Z t U <br />�Q <br />U) d <br />C <br />Q N O <br />~ <br />0 <br />CIO <br />w <br />M <br />J <br />o3 <br />z <br />a <br />E <br />� <br />a p <br />E V <br />zo <br />G� <br />w <br />'za <br />z® <br />oa <br />H n3 <br />_ <br /><- <br />�o <br />0 � <br />¢ a <br />0 <br />O Q <br />¢z <br />Z� <br />H <br />wo <br />�w <br />L <br />(O <br />i _ <br />a o <br />V <br />w C) <br />m <br />OZ <br />Z <br />m � <br />5 J <br />Nm <br />a ° <br /><W <br />�Z <br />O4 <br />z <br />ao <br />WT3 <br />V) � <br />2<�w <br />�O <br />[h <br />az <br />w <br />w ¢ <br />3 <br />O� <br />'0 <br />V <br />zl¢ <br />O - <br />U <br />HO <br />Li <br />In <br />Q <br />� <br />� <br />N <br />: O <br />Nt <br />Cr <br />O <br />Y <br />T <br />C) <br />a� <br />N <br />M <br />W <br />m <br />LO <br />T <br />+ U) <br />Q <br />O `� N <br />rn <br />� <br />0 o <br />O <br />LL 04 <br />LO <br />Q M <br />T <br />N M <br />Z <br />M <br />Z <br />E O <br />E w <br />v <br />a <br />¢ o <br />JOB <br />NO: 23-02469 <br />SCALE : AS NOTED <br />SHEET NO. <br />8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.