CD <br />A <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />n <br />200 amp <br />150 amp <br />UNDERGROUND lag <br />SERVICE BY POWER CO.---,_ <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER 71 <br />NEC 17. 250.94 <br />M14 to lights & outlets <br />NEMA 1 00 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10 010 to WH -� I <br />/ I <br />a8 to Range <br />Ma to HVAC <br />50=2l0 • . -'' i Tie <br />200=410 in 2" Conduit <br />/ <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />GENERAL ELECTRICAL NOTES. <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 18" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FTF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e <br />TRACK LIGHT <br />�-� <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />1Q� <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />is <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />a <br />ELECTRIC PANEL <br />_L...1 <br />DISCONNECT SWITCH <br />Q�o <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />of III 1"1Cm <br />15'-0" <br />21 <br />ENTRY <br />LIGHT AS <br />PER SPECS <br />SENTRY <br />Q <br />2n <br />PLUMBING RISER '111 <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=l'-0" <br />CEO.' <br />o <br />N <br />00 <br />0 <br />CA- v <br />> w <br />0 <br />o <br />C f0 C.J C7 <br />,: hl <br />� rWrz <br />CU <br />t <br />d U <br />G <br />ch <br />N <br />0 <br />N <br />w <br />0 <br />M <br />`^ No <br />f .• K� � <br />nt A �' r <br />`/C % <br />1,1111J17ii�i� <br />To the best of the Enginee s knowledge, information antl belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Resldential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />ttrr <br />p N <br />O M N - u` <br />J <br />(0V (� <br />pB fJ <br />rNivJv LL a LU <br />a <br />�a <br />a-�LL� <br />o <br />0 g 8 <br />0C' <br />m J13 g <br />W CPLu <br />o�p <br />U rn <br />IL Z tti N Z U <br />N <br />Z a OHO <br />W <br />C9 Cq <br />z <br />z <br />z <br />J <br />a- u, <br />N <br />t! ! z <br />^' <br />+_j cry LL <br />W <br />Jim <br />W <br />m <br />ILS �- <br />u � <br />Q M <br />a� <br />lt <br />I4e <br />" <br />Zi <br />{ _ E <br />Z O <br />0oZO <br />) H <br />aR <br />E 8 <br />wi <br />oa <br />~ row <br />wo <br />3 u <br />Z <br />O E <br />c0 ru <br />li °z <br />ap <br />Orcd <br />a z <br />N t <br />�w <br />C <br />yY <br />z w <br />Z� <br />m J <br />a ° <br />az <br />w <br />z <br />W <br />m <br />0? <br />R <br />Z a <br />Ou <br />0 <br />c O <br />= <br />jLO <br />LO <br />rn <br />Um <br />W <br />co <br />CD <br />Cr <br />Y <br />T <br />C <br />N <br />m <br />m <br />Ln <br />a <br />O <br />cola <br />ce <br />O <br />00 <br />LO <br />00 <br />N <br />oNo N <br />Q M ^ <br />r <br />ci <br />E <br />CO � <br />M M <br />z <br />Z <br />E O <br />n <br />E <br />U _j Q p <br />c <br />JOB <br />NO : 23-02469 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.1 <br />