Laserfiche WebLink
I I I I II I _L t I I I 1 _ 11 ! I' I 1 _ 1. I I — I' _ __ I _ _ I , _ _ I _. <br />0(2)— <br />TYP. @ HIP <br />CORNERS <br />TYP. <br />U.N.O. <br />r------------------� <br />i <br />I I <br />I I <br />I I <br />I <br />I -rvP G I <br />j U U U G <br />TYP. U U <br />I U.N.O. I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />M <br />U <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />VIND SPEED (ULTIMATE) 140.0 MPH <br />VIND SPEED (ALLOWABLE) 108.4 MPH <br />XPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 45 DEG. <br />WIND AREA (+) VALUE DENOTES PRESSURE <br />(SO FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=oft <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />10 HIP -35.94 -49.57 -49.57 -49.57 <br />GABLE -38.22 -38.22 -60.99 -60.99 -60.99 78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: Y16" EXP. 1 (2%6) or 1V32" EXP. 1 (3y16) <br />TILE: 1%2" EXP. 1 (33116) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 3/" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1%2", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2""/z" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS a=4ft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING [4:12]-[12:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 -10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795(2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 1 Od x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-1 Od <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />RFUS <br />7100 <br />-- <br />w/ (12) WS3 WOOD <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />(A) <br />OR 2 PLY <br />;ARRIER <br />1-8-8 CLEAR GAP BETWEEN (8) TRUSSES (+/- 6") <br />'FASTEN EACH (B) TRUSS "CO TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (•*). (B <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 O .-(A)-- <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />LZ <br />Cv <br />FX CONT LEDGER <br />Lo "L <br />13 j__ Mi <br />Luj <br />0 <br />.1. UA 130 <br />U) <br />4-1 <br />i <br />04 <br />0CIO <br />CD <br />U0 <br />) <br />U).LO <br />2 <br />ROOF FRAMING PLAN -A. <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />CQ <br />Z <br />W <br />O r O <br />r. <br />� a o <br />C <O U N <br />9C <br />� o <br />N a7 C <br />4 N <br />m <br />j. I✓ <br />rc <br />=- <br />- <br />c E <br />r <br />rJ <br />_J <br />I` LO <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />0 <br />