36434 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36434 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 4:12:43 PM
Creation date
2/18/2025 4:12:31 PM
Metadata
Fields
Template:
Building Plans
Street #
36434
Location
Garden Wall Way
Contractor
Lennar Home
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION 150A/2 LC NENTTERER <br />PANEL C <br />DOOR <br />NOTES: 10 #14 to lights 8 outlets <br />NEMA 1 b #12 to appliances and GFI <br />150 AMP1 <br />ELECTRICAL CONTRACTOR 200 AMP 0 #10 to WH <br />MUST VERIFY WITH THE 0 #&to Range <br />SPECIFICATIONS FOR THE TYPE 0 #6 to HVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR METER <br />LOCATION PURPOSES. MAINT <br />150=2/0 <br />200=410 in 2" Conduit <br />200 amp <br />150 amp <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />FO HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />O RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />16) EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />�]aD PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />e USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />M ELECTRIC METER <br />WWI ELECTRIC PANEL <br />MW-j DISCONNECT SWITCH <br />��/� <br />ROUGH -IN FOR OPT. CEILING FAN <br />C� J <br />Ql�/� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />UNDERGROUND Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING o #4 GROUNDING WIRE <br />TERMINATION PER 71 WITH CODE APPROVED <br />NEC 17, 250.94 ��J// CLAMP PER 250.50 AND <br />2%52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS— <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />SPEC 3 & 4 KITCHEN_ <br />SCALE: 1/4"=V-0" <br />l• -------------------� <br />----LANAI ----Na. I I <br />I I <br />/� > I <br />AC PAD <br />CFI `�/ I GFI DISC. I I <br />� I <br />u I I <br />lei, \ I (I I) Q' 1 <br />n <br />- _ 1 ALT <br />AC PAD j I <br />— >BRKFS _ <br />I :! <br />WP <br />DINING <br />—_ <br />LIGHT AS P R <br />SPECS ` to 5'-0 <br />F " C OPl <br />LIGHT AS PER <br />SPECS • <br />PENDANT <br />I, <br />LIGHT PER <br />/�_ SPECS <br />I ' �" GREAT RM <br />0 <br />1 I ��I I <br />fi-� 1 - <br />DEDICATED GFI I GFI <br />12 <br />RECEPTACLE FOR • -- - - I ROUGH -IN • <br />MICROWAVE RANGE - U.C. OUTLET FOR OPT. <br />HOOD PER SPECS o I o z'' I (/ FAN/LIGHT <br />0 I I GF I <br />SWITCH FOR , OPT. CLG. FAN/ <br />DISPOSAL I \LIGHT PRE -WIRE <br />GFI <br />II <br />•. co <br />LU <br />2'-8" v 1'-10 <br />17 <br />- 3 <br />f- <br />--T_ <br />• - �, �H - - - - -• <br />r -r I 7,� <br />LS <br />I D H► I i i i i i i I--` - <br />I <br />- w � GFI @ 44' FOYER <br />A.F.F. _ <br />W <br />�0X <br />yz <br />a ■ <br />= V J Z W <br />>-j °Q ! - <br />a I • • -� • <br />0 � `\ GARAGE / WP DB <br />WP L` U LIGHT AS I I <br />GFI w U PER SPECS GFI <br />• ' W GARAGE <br />GARAGEDOOR <br />- , <br />GFI I ENTRY <br />r-------------------------------� <br />10 <br />10 I I <br />• I IRRIGATION GFI I I •-------- <br />• I @ 44" A.F.F. ` ■ -------- <br />I 1 I <br />------------------------------ <br />I ` I <br />I I <br />I � I <br />I � I <br />■ •------------------------------, ■ ■ <br />COACH LIGHTS \)b <br />OR PREWIRE AS <br />PER SPECS <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />GFI @ <br />44" A.F.F. <br />WIC <br />I <br />L-------� _-�- <br />S.D\ <br />� <br />S.D. <br />I <br />I 1 <br />12 <br />OPT. CLG. FAN I <br />LIGHT PRE -WIRE <br />BEDROOM 3 <br />OWNER'S <br />SUITE <br />/ OPT. CLG. FAN/ <br />/ LIGHT PRE -WIRE <br />I ' <br />/OPT. CLG. FAN/ <br />i LIGHT PRE -WIRE <br />BEDROOM 4 <br />S.D. <br />I <br />� � I <br />I <br />VI H W 1 1 <br />:L W I <br />I1 <br />I� <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />2 <br />BEDROOM 2 <br />I 1 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />n <br />R 3" VTR Ij1, <br />III, I <br />�I I <br />I I <br />I I <br />I I <br />I r� <br />3" VTR II1, <br />�I <br />I j \1 ► j <br />I I I I I <br />I I I 7u I I <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN -A <br />SCALE: %4"=1'-0" <br />0 <br />1v � <br />�i <br />Ci <br />U iZ h <br />M <br />C fC V CV <br />m x <br />N d <br />•� o s <br />� 3 <br />to co <br />c <br />N <br />O <br />fV <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a <br />�E <br />0 <br />8 <br />O <br />0 <br />� CO N <br />�. <br />Q <br />LL <br />c" 0 <br />-j LL tL <br />a <br />Z <br />°'3,* <br />W <br />a <br />Q <br />�$ <br />�. <br />: (p N (O O <br />0 <br />05 <br />W <br />T m <br />NZ QrILZCo 0 <br />OU 0 <br />Z <br />W <br />❑ ❑ <br />Z N M <br />o � <br />z <br />z o � <br />Q <br />_n <br />WEIIIIIIIIIIII <br />U) <br />N <br />a. <br />z <br />4-1 <br />C <br />w m <br />� a <br />io <br />U <br />0 <br />w $ <br />�N <br />= U) <br />U C <br />w � <br />° <br />U o <br />Q 0 <br />soy <br />c <br />w <br />M2 <br />O <br />Z <br />E <br />U- <br />E °� <br />�� <br />��a <br />i <br />g <br />z9 <br />_® <br />❑a <br />Z <br />�_� <br />O <br />� <br />U❑ <br />d < <br />Qi <br />00 <br />O Q <br />wz <br />(v <br /><g <br />� w <br />ru <br />N CY <br />z <br />mE <br />O <br />Ott <br />Z <br />in e <br />U <br />Nm <br />F� <br /><w <br />ZZ <br />a <br />s� <br />Z <br />go <br />W <br />Q <br />w <br />a <br />�W <br />°z <br />o <br />< <br />F <br />;o <br />coMj <br />0.. <br />a <br />OO11) 3 <br />>U-) <br />O <br />hi <br />rn <br />00 <br />00 <br />0 <br />^' <br />L <br />c <br />T <br />c0 <br />T <br />co <br />Oaje <br />m <br />N <br />.. <br />�LO— <br />`� <br />Os` <br />rll-- <br />M <br />cc <br />0 (� <br />Q <br />M N <br />L.0 <br />T <br />to <br />T <br />M r <br />Z <br />@ <br />Z <br />C T <br />E T <br />y <br />a <br />E <br />U � <br />v ?? <br />Q p <br />c <br />JOB <br />NO: <br />22-12360 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />