My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36442 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36442 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 4:37:47 PM
Creation date
2/18/2025 4:12:58 PM
Metadata
Fields
Template:
Building Plans
Street #
36442
Location
Garden Wall Way
Contractor
Lennar Home
Building Plans - Permit #
5693
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS <br />AB or A.B. Anchor Bolt FIX or FXD Fixed RA or R/A or R.A. Return Air <br />ABV or Abv. Above FLR or Flr. Floor RAD or Rad. Radius <br />AC or A/C Air -Conditioner FLR SYS or Flr Sys Floor System RAG or Rag. Return Air Grill <br />ADJ orADJ. Adjustable FOM or F.O.M. Face Of Masonry REC or Rec. Recessed <br />AFF or A.F.F. Above Finished Floor FP or F.P. Fireplace RECEPT Receptacle <br />AHU or A.H.U. Air Handler Unit FIR DR French Door REF or Ref. Refrigerator <br />ALTorALT. Alternate FRT Front REINF Reinforcing <br />BC Base Cabinet FT or Ft. Foot/ Feet REQD or Req'd. Required <br />BF Bdold Door FTG or Ftg. Footing RM or Rm. Room <br />BK SH or Bk Sh BookShelf FXD GL Fixed Glass RND or Rnd. Round <br />BLK or BLK. Block GALV or Galy. Galvanized RO or R.O. Rough Opening <br />BLW or BLW. Below GC or G.C. General Contractor IRS, R/S, R/SH or R&S Rod and Shelf <br />BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter SC Solid Core <br />BOT or Bot. Bottom GT or G.T. Girder Truss SD or SD. Smoke Detector <br />BP or B.P. Bypass (door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door <br />BRG or BRG. Bearing HB Hose Bibb SH or Sh. Shelves <br />C Carpet HC Hollow Core SHT Sheet <br />CAB Cabinet HDR or Hdr. Header SHWR or Shwr. Shower <br />CIR or Cir. Cirde HGT or Hgt. Height SL or S.L. Side Lights <br />CJ or C/J Control Joint HH or H.H. Hand Held (plumbing faucet) SPECS or SPECS. Specifications <br />CLG or Clg. Ceiling HORIZ Horizontal SPF or S.P.F. Spruce Pine Fir ^ <br />CMU Concrete Masonry Unit HS Hard Surface (flooring) SQ FT or SF or S.F. Square Foot (feet) \ <br />COFF or Coff. Coffered or Tray Ceiling ILO In Lieu Of SQ or Sq. Square \ <br />COL or Col. Column INSUL or Insul. Insulation STO Storage \ <br />COMM or Comm. Community INT or Int. Interior SW or S.W. Shear Wall <br />COMP or Comp. Compressor K/WALL or K/Wall Kneewall SYP or S.Y.P. Southern Yellow Pine <br />CONN or CONN. Connection KS or K.S. Knee Space TB Towel Bar 0 <br />CONT or Cont. Continuous LAUN or Laun. Laundry TEMP or Temp. Tempered O O <br />CSMT Casement LAV or Lay. Lavatory THIKN or Thik'n. Thicken \ <br />CT or C.T. Ceramic Tile LF or L.F. Linear Ft. TOB or T.O.B. Top of Block <br />D or D. Dryer LL Lintel Length TOM or T.O.M. Top of Masonry <br />DB Door Bell LT Laundry Tub TOP or T.O.P. Top of Plate <br />DBL or Dbl. Double MAS or Mas. Masonry TP Toilet Paper Holder <br />DCF Decorative Cementitious Finish MAX or Max Maximum TR Towel Ring M <br />DEC or Dec. Decorarativve MC Medicine Cabinet TRANS WDW or Trans. Transom Window� � DED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TYP or Typ. Typical � / <br />DIA or Dia. Diameter MGT Management (room) UC or u.c. Under Counter v v <br />DISP or Disp. Disposal MIN or Min Minimum UCL Under Cabinet Lighting <br />DIST or Dist. Distance MIR or Mir. Mirror LINO or U.N.O. Unless Noted Otherwise E:1 D <br />DMF Decorative Masonry Finish ML or M.L. Microlam V or v. Valve (shower or tub/shower) <br />DS or D.S. Drawer Stack MONO or Mono Monolithic VB Vanity Base <br />DTL Detail MW or MICRO or Micro. Microwave VERT or Vert. Vertical <br />DV or D.V. Dryer Vent NTS or N.T.S. Not to Scale VL or V.L. Versalam <br />DVP or D.V.P. Diverter Valve (plumbing) OE or O.E. Owner's Entry VTR or VTE Vent through Roof / Exterior <br />DW or D.W. Dishwasher OPNG or Opn'g. Opening W or w Washer n <br />EA or Ea. Each OPT or Opt. Optional W/ or w/ With <br />ELEC or Elec. Electrical PC Pull Chain WA or W.A. Wedge Anchor <br />ELEV or Elev. Elevation PED or Ped. Pedestal WC or W/C or W.C. Water Closet (toilet) <br />EQ Equal PH Phone WD or Wd Wood <br />EW or E.W. Each Way PKT or Pkt. Pocket (Door) WDW HDR or WDW. HDR. Window Header <br />EXP or Exp. Expansion PL or P.L. Parallam WH or W.H. Water Heater <br />EXT or Ext. Exterior PLF Pounds per linear foot WIC or W.I.C. Walk-in Closet <br />FBC Florida Building Code PLNT SHLF or Plt. Sh. Plant Shelf WM or W.M. Wall Mounted (plumbing fixture) <br />FDN or Fdn. Foundation PLT HT or Plt. Ht. Plate Height WP Water Proofing) <br />FFB Finsh Floor Break PSF Pounds per square foot WS Water Softener <br />FG Fiberglass (Shower Pan) PT or P.T. Pressure Treated WWF Welded Wire Fabric (Mesh) <br />FIN Finished PW or P.W. Pre -wire <br />FIN FLR or FF or Fin. Flr. Finished Floor PWDR or Pwd. Powder Room REV. 06,23.22 <br />PLAN REVISIONS <br />DATE VERSION DESCRIPTION <br />08/23/12 1.00 NEW BASE PLAN <br />07/30/15 1.1 2015 NEW CODE UPDATE <br />05/09/18 2.0 FBC 2017 CODE UPDATES <br />12/19/20 3.0 FBC 2020 CODE UPDATES <br />2074 <br />slid <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS COVER SHEET <br />1.1 FIRST FLOOR PLAN <br />1.2 SECOND FLOOR PLAN <br />2.1 EXTERIOR ELEVATIONS - FRONT & LEFT <br />2•2 EXTERIOR ELEVATIONS - REAR & RIGHT <br />3 ELECTRICAL PLAN <br />4 ROOF PLAN J•� <br />5 FOUNDATION PLAN <br />6.1 FLOOR FRAMING PLAN <br />6.2 ROOF FRAMING PLAN <br />7 LINTEL PLAN & DETAILS <br />SN STRUCTURAL NOT ES <br />SN1 DETAILS <br />S3 DETAILS <br />S4 DETAILS <br />S5 DETAILS <br />S6M DETAILS <br />ST STAIR DETAILS <br />SS RETROFIT DETAILS <br />D1 SECTIONS & DETAILS <br />D2 SECTIONS & DETAILS <br />WP WATERPROOFING DETAILS <br />PA1.0 PRODUCT APPROVAL NUMBERS <br />PA1.1 PRODUCT APPROVAL NUMBERS <br />PA1.2 PRODUCT APPROVAL NUMBERS <br />SH1.0 HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.1 HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.2 HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.3 HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.4 HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.5 HURRICANE SHUTTER PRODUCT APPROVAL <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />Control of Construction Site <br />The DesignerlArchitect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />M <br />N <br />' <br />d <br />C%Q <br />c , <br />C fC U N <br />N C fn <br />Z <br />Q d CV Y <br />7�` <br />_ <br />�E� <br />U d <br />� 3 � <br />` W C Q <br />N G� <br />c � <br />R o <br />a_ <br />w�- <br />P <br />P: ,A S E <br />'` � .,• �� <br />�n NQ <br />�� ` V III •• �R <br />F I <br />- <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />H <br />a <br />Cn 8 <br />N N 01 IFi <br />y C N r <br />' <br />P-- <br />�r- <br />N O 2 M u <br />25Sz <br />a'? a <br />� <br />N LL LL 5 LL W <br />55 <br />' Z <br />13 <br />Wd <br />= o a <br />If - o <br />0 <br />tnZrnrn m <br />W <br />I Zz IL <br />� <br />;^ <br />t <br />N <br />O U <br />Z <br />(D <br />z N M <br />z C' CO <br />N <br />z <br />v <br />� o <br />4-J <br />f6 <br />"LU <br />' 2- <br />�U <br />0LL'Cq <br />V1 <br />c_ <br />�V1 <br />U) <br />. <br />U <br />W J <br />U o y <br />C N d <br />QQ- <br />i-4 <br />o <br />'o <br />Cl)W <br />M <br />� <br />Z <br />Z <br />¢ <br />f <br />zo <br />Zo <br />go <br />E u <br />(Q 1 <br />F- <br />w <br />20 <br />XU <br />om <br />UO <br />0U <br />ZD <br />¢r <br />¢o <br />OQ <br />ww <br />i <br />°do <br />m� <br />(4 <br />�� <br />ozZ <br />U <br />F O <br />Z <br />� <br />aw <br />2Z <br />� 3 <br />0F <br />29 <br />Z. ao <br />�w <br />WCL <br />U �' <br />�o <br />�= <br />w <br />wiz <br />�5 <br />>C) <br />o <br />5 00 <br />a <br />a) O <br />' cM <br />O, <br />m <br />0 <br />� <br />N <br />a <br />CIO <br />:3 O <br />o <br />X <br />to <br />V / <br />j� <br />m <br />4-1 <br />Ll J <br />� <br />O <br />'n <br />� <br />h <br />ca <br />N O <br />l0 <br />N <br />Qlot <br />N <br />r <br />N <br />M N <br />o <br />Z <br />M <br />Z <br />j <br />E <br />N T <br />c <br />c <br />a <br />U � <br />Q p <br />JOB <br />NO: <br />22-12361 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />C S <br />
The URL can be used to link to this page
Your browser does not support the video tag.