My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36442 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36442 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 4:37:47 PM
Creation date
2/18/2025 4:12:58 PM
Metadata
Fields
Template:
Building Plans
Street #
36442
Location
Garden Wall Way
Contractor
Lennar Home
Building Plans - Permit #
5693
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ck: <br />V) <br />CD <br />E, <br />:9 <br />E <br />2 <br />E <br />0 <br />12 <br />0 <br />0 <br />to <br />CL <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />MASONRY <br />WINDOW BUCK <br />-2) SEALANT JOINT <br />5) SEALANT FROM <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />Y// ATTACHED <br />PER CODE <br />'ANT <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />ING <br />BEAD BRIDGING <br />7 <br />ND VANDOW_- <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 0605 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATHTWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />'V'SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />ff�, in 1 in <br />�E BARRIER & <br />ARILY SECURE <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIC <br />1. Cut, fold up & temporarily secure <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NITS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING X <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WOOD FRAME CONSTR. <br />EXTER <br />[OR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN ---, <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER EAL TOPS OF JOK <br />S <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />ED FLASHING <br />SELF -ADHERED FLASHING <br />WEATHER RESISTIVE <br />BARRIER <br />ON hm. N <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4%1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />A <br />IN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL <br />SELF -ADHERED FLASHING - <br />1 <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />8 (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />I WA <br />SELF -ADHERED SELF -ADHERED <br />FLASHING FLASHING <br />(D <br />SCS 06 02 WINDOW FIN INTERFACE WITH SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER DECK JOIST <br />2x FRAMEWALL <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS TILE FINISH - <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />10DUROCK- <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as (# in each detail that corresponds to the <br />Pinstructions <br />numbered items in the list o below: <br />1 . Install self -adhered flashing in order as shown by numbers <br />8" CMU <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />4" OR 8" CMU <br />3. Self -adhered flashing can be substituted for building paper <br />(PER SEAT DEPTH)- <br />4. Split the release paper using the ripcord (Split release on demand, <br />FILL WITH GROUT - <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />SLOPED MUD BED- <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />VINYL SHOWER PAN <br />8. Mechanically fasten as necessary <br />1'4' PER PLAN <br />-0" PER PLAN <br />0 M <br />MM <br />M <br />MM <br />M <br />SHOWEk SEAT <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />VJ <br />> <br />co <br />< <br />Z 1 <br />y <br />WINDOW UNIT FLASHING REQUIREMENTS <br />DOOR ROUGH OPENING SLOPE <br />0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0.6 cm: 30.5 cm) <br />- 3/4"-1 "BEAD OF CONSTR. include flashing as described in Section R703.4. <br />ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID R703.1.1 Water resistance. The exterior wall envelope shall bedesigned and constructed in a manner that prevents the accumulation of <br />NAIL BRAND OR EQUAL WEATHER EXTERIOR <br />water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />PROOF CAULKING CEMT. FIN. <br />of draining to the exterior water that penetrates the exterior cladding. <br />SELF -ADHERED FLASHING BUILDING PAPER <br />WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />SUBFLOOR other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be ap <br />lied <br />7-= <br />lss� horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />_J <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />RIM JOIST <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703. 1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />71 1 wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />A li I <br />V Q D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT substantially nonwater-absorbing layer or designed drainage space. <br />RUBBERIZED <br />NEEDED IN CORNERS <br />INSTALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />FLASHING JAMB & HEAD ADHESIVE R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />FLASHING, SEE FLASHING SELF -ADHERED FLASHING-, <br />applied shingle -fashion or in accordance with the manufacturers instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />�IZED <br />VE <br />HING <br />FLANGED VANDOW <br />(SEE DETAIL WP01) membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />SELF -ADHERED FLASHING, (BEFORE FOLDING, SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />RELEASE PAPER TO EXPOSE <br />EXTEND A MINIMUM 6" ADHESIVE AS SHOWN) contraction, ASTMC1 281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />VERTICALLY FROM <br />BOTTOMOF flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />THRESHOLD shall be installed at the following locations: <br />1. 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />P2 <br />following: <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 manufacturers instructions, in accordance with the flashing manufacturers instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />6 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />2 7 subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />SELF -ADHERED FLASHING <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMAAAIDMA 400. <br />INSIDE CORNER <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground 3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4. Conti n uously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />Water Resistant Barrier 7.7.At built-in autters. <br />LU LU PLASTER STOP <br />a- a- )P <br />F_ ct) <br />cf) CONTINUOUS BACKER <br />LU <br />ROD & SEALANT <br />Lu LL1 <br />cr_ <br />!,� <br />Lu <br />U-1 <br />(n 3�: <br />0 <br />Cn <br />:LF-ADHERED FLASHING <br />kTCH <br />,HERED FLASHING <br />2 <br />4 <br />5 <br />I <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SFLATH <br />WRAP DIP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTI LEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) _1D ------- 0- <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER MMB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING, 'OSB', PLYWOOD, DENSGLASS NXN:S� <br />ACKER ROD <br />FINISH <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />1 <br />7 <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC 1063 <br />Building Paper <br />-7/16" O.S.B� <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" 0. S. B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />CIO <br />_CX <br />;W <br />C= <br />me- C= <br />Ca 'V 1-4 <br />CIL. <br />-ft <br />W <br />C14 <br />To the best of the Enginser's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential <br />7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />8 E <br />0 n <br />(0 <br />No C� 0, 8 <br />0 C., C - <br />o <br />te .0 % <br />?2 <br />a <br />No , -� <br />M U. U- u- <br />:9 2 <br />Z <br />G <br />0 <br />P. ;; 2 t <br />W <br />Z <br />ILW <br />L <br />. . M Lu <br />Z� 0 <br />oo, Z < <br />C-4 <br />0 <br />< 0 <br />13 <br />< <br />0 <br />4-1 CJ'3 - <br />0 <br />C> <br />UJ <br />V) <br />V) <br />A <br />LU 0 <br />so <br />E <br />= . <br />100 <br />I <br />U I I <br />in 0 <br />co <br />s <br />- <br />CD <br />CC) <br />C0 <br />go4:1) <br />Z <br />__J <br />U- <br />ce E <br />52 <br />cl- 8 <br />E <br />9 <br />0 <br />Z0. <br />c:) E <br />M <br />0 <br />I EE <br />0 <br />Z, <br />Z <br />co <br />1. <br />89 <br />Z <br />0 <br />0 <br />3: <br />Z <br />ow <br />W <br />3: <br />C-) <br />D 0 <br />T <br />Z <br />X <br />CD <br />0 S <br />1. <br />< <br />§1, <br />W <br />r_ 0 <br />.0 <br />12 . <br />cr) <br />X <br />0 <br />0) <br />2 <br />cc <br />cc <br />0 <br />-6 <br />co <br />.2 <br />04 <br />IUD <br />0 <br />'2 <br />co <br />04 <br />0 <br />(D C'4 <br />la) <br />C:) <br />N 0 <br />LO <br />< <br />11" N <br />14" <br />T_ <br />E <br />.t <br />CD <br />M C14 <br />0 <br />Z <br />E <br />Z <br />a <br />M <br />E <br />0 <br />(L <br />0 _J <br />JOB <br />NO <br />22-12361 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />WP1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.