ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />MAIN <br />0 <br />200 amp <br />150 amp <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.----_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />3 to lights & outlets <br />2 to appliances and GFI <br />to WH <br />to Range <br />to HVAC <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory, <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />FqT <br />W.P. <br />KG.F.L <br />I� <br />I� <br />$3 <br />?4 <br />$R <br />FO <br />4-P.C. <br />%W <br />a <br />CH <br />PB <br />DB <br />SD <br />CM <br />USB <br />❑TV <br />❑N2 <br />own <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />1.5" VTR <br />I <br />I <br />—111 3" VTR <br />I � I <br /><\\ I I I <br />VTR <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN SWITCH <br />EXHAUST FAN/LIGHT COMBINATION DISP( <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) \ <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />PLUMBING RISER <br />SCALE: NTS <br />KITCHE <br />LI1(15��7 <br />111 �1 411 <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED <br />RECEPTACLE FOR <br />CROWAVE RANGE <br />HOOD PER SPECS <br />WP A/C PAD <br />GFI DISC. <br />.I'i. <br />I , <br />1 <br />ENTRY <br />vP <br />DB &GFI TO I GFI <br />BEALIGNED------- <br />VERTICALLY <br />�1 <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />= Er <br />w w <br />I_ 0 <br />W Z -1 <br />2 O0 m <br />HUH <br />> _j <br />COACH LIGHTS COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS \ / PER SPECS <br />ROUGH -IN FOR OPT. CEILING FAN I SPEC 3 & 4 KITCHEN FIRST FLOOR ELECTRICAL PLAN - ELEV-B <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT, CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />SCALE: %4'=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />� I I <br />� f I <br />� I I <br />� I I <br />� I I <br />L----------� I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I i <br />I i <br />I i <br />I i <br />I 1 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -I <br />SECOND FLOOR ELECTRICAL PLAN <br />ELEV-B <br />�+ <br />c <br />� <br />w <br />Cam. O <br />z <br />U CL <br />y, C W p- <br />Vf O 10 <br />E s c <br />CL.. col •n[ <br />tr 3 <br />iCi d m .La <br />� u m <br />? c r <br />CIA <br />E <br />0 0 <br />a` <br />r- <br />N <br />0 <br />N <br />N <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />M <br />W <br />a <br />E <br />8 <br />00 <br />N 0 <br />N <br />co, <br />Y/ <br />6n r 0 J <br />di <br />M V LL <br />LL <br />a1 I J <br />f9 <br />13 n <br />JLLLL a <br />a <br />Z <br />'a 0, 4 <br />cc @2�_ 0 <br />Z <br />co N z Cl) d <br />LO <br />Z <br />N <br />V vIL <br />W <br />00 <br />z N � <br />z C' � <br />z <br />n <br />th <br />W <br />� <br />U <br />0 <br />W $ <br />CI1 <br />c N <br />r) <br />� <br />� (3 <br />_ <br />'— r'n <br />W <br />— E <br />L � <br />I <br />x <br />Q Y <br />m <br />N <br />l` m <br />o <br />W <br />ZZ <br />w <br />J <br />I <br />Q o <br />a <br />w� <br />�a <br />W,_Do- <br />Z® <br />m U <br />rO <br />o <br />0 U <br />0Z <br />00 <br />�U <br />Oz <br />Z <br />N f6 <br />L <br />a� <br />< <br />as <br />w <br />�: <br />t0 <br />z <br />m 0 <br />O LL <br />Z(n <br />) <br />In J <br />a� <br />gZ <br />a`�i 3 <br />a3 <br />8 <br />g o <br />�W <br />W <br />3 <br />wLL <br />�2 <br />yE <br />=3 <br />� 5 <br />o <br />co <br />UJ <br />1 <br />>0 <br />a <br />q- <br />z d°• <br />cOiU ?i <br />C 0 <br />i <br />0 <br />o� <br />m <br />c� <br />N <br />>' <br />T' <br />C) <br />^ <br />Cr Y <br />`° <br />0 <br />0- <br />U) in <br />N <br />'2 <br />t\ <br />O <br />.� <br />(D N <br />N O <br />0) <br />LO <br />O <br />Q <br />� C14 <br />T' <br />ui <br />E <br />41 <br />N <br />M N <br />o <br />Z <br />Z <br />7 <br />E f� <br />iJl T <br />m <br />c <br />m <br />JOB <br />NO: <br />22-12361 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />