Laserfiche WebLink
I <br />cc <br />C? <br />ao <br />O.Y._@ R. <br />__1JTRY <br />I HDR. HGT. <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />12 <br />5 <br />12 <br />5 k_� <br />ff�f 12 <br />25 SH 25 SH 5 <br />2ND FIN. FLR. <br />— — — -- — — — — — — — — — — — — — — — — — — — — — <br />T 0 M <br />T.O.M. @ GAR. <br />ENTRY <br />NHDR. HGT. <br />I <br />SCORED — <br />STUCCO BANDS <br />�:� ----------- = ---------- - --7qs <br />- - - - - - - - - - =_)� - - - — -- - - - - - - - - - - - - - - <br />4 CJ /WEEP <br />U U <br />�, El L] 111 El El El ET::1 <br />r E] El El [::] El El El <br />FIN. <br />SCOREDSTUCCO <br />BANDS ---\ <br />16070 OVERHEAD DOOR <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON CMU <br />SCOREDSTUCCO <br />BANDS <br />0 <br />FRONT ELEVATION — A <br />SCALE: 114" = V-0" <br />FIN.-FLR.—__l . . . . . . . . . . . . . . . . . . . . . . L__]__ <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />12 <br />12 <br />5L�, 5 <br />_. <br />SCORED <br />STUCCO <br />BANDS <br />SILL DETAIL <br />SCALE: 3/4" = V-0" <br />HEAD DETAIL <br />SCALE: 3/4" = V-0" <br />SCORED <br />f_1 <br />0 1 U�_Ikl <br />BANDEE <br />L. V-6' I. <br />DECO SHUTTER <br />SCALE: 3/4" = V-0" <br />FLASHING <br />----------------------------- --------------------------- F ------------------------------- I ------ <br />/I--- <br />35 SH <br />CJ / WEEP <br />77­­� <br />RIGHT ELEVATION — A <br />SCALE: 1/4" = V-0" <br />General Notes <br />ROOF CRITERIA: <br />12" OVERHANG U.N.O. <br />PLUMB CUT FASCIA ROOF <br />PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1 063, or ASTM C1 787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1 063 or C1 787, or as otherwise <br />approved. (Refer to sheet SNII for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1 -1 /2" long (3/4"-1 " crown) staples @ <br />61' O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1 " dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1 063 & ASTM C1 861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1 (1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />x enor w enve ope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1 281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />At wall and roof intersection. <br />At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09,24.21 <br />co <br />14 <br />It <br />'AG <br />0 N <br />C <br />CW <br />_.J <br />75, <br />IF <br />"YOFES5\0 <br />I lilt <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal, <br />W <br />AMANk 0 E <br />0 co 8 <br />ci) <br />0 .0 <br />CN b <br />LL. <br />-1.6— <br />'Fa 0,1 <br />13 <br />Z q <br />= M C, <br />W :5=; r,-y 0 <br />W 020),.� <br />W (n . . on Lu <br />Z L- Z�Zc)<� <br />F_ <br />0 co <br />IL <br />, <br />Cq . . < F_ <br />a 0 a, 0 <br />< 0 <br />Z 1.) U) <br />W El 1771 <br />CD �2 <br />�O <br />Q) <br />LU <br />fn ZF. <br />U — <br />0 LLJ <br />Ull <br />U) <br />I_ <br />LU cs <br />0 <br />C.0 <br />M <br />C11 <br />UL <br />ocir E <br />ca- 0 <br />_0 <br />— <br />- 1Z <br />< R <br />Za <br />U <br />< � <br />W , <br />20. <br />0 <br />Z <br />E <br />C14 <br />0 <br />Z <br />Z <br />'0 <br />0, <br />Z , <br />Z <br />2 <br />z. <br />CL <br />W <br />< 0 <br />MilliC:) <br />(0 <br />J <br />TZ <br />Q) <br />> <br />C13 <br />0 <br />co r-_ <br />C10 <br />co <br />:3 C:) <br />T_ <br />r1*1 <br />co <br />C:) <br />U) .2 <br />LO <br />�%.O000 <br />0 <br />CU <br />(D C'4 <br />CD <br />C) <br />C) C) <br />L0 <br />< It <br />110 <br />cc <br />I — <br />E <br />CY) CN <br />CIO i� 00 <br />0 <br />M <br />Z <br />E (n <br />CU <br />E 4i <br />0 0 _0 Zi <br />0 _J < 0 1 <br />a) <br />_J <br />JOB <br />NO: 22-09401 <br />SCALE : AS NOTED <br />SHEET NO. <br />2.1 <br />