ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DIFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R3114.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />LIL 2075, gas and vapor detector sensor, according to the installation. , <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />�W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />K%.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />k(� <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />i�2F <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�_o <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />[CH] <br />CHIMES (OPTIONAL) <br />�N <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEP HONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />[TV] 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />t <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />1 5OA/200A INDOOR <br />PANELCENTER <br />P <br />#14 to lights& outlets <br />NEMA 1 10 <br />#12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10 <br />#10 to WH <br />11-#8 <br />to Range <br />10 <br />#6 to HVAC <br />METER <br />MAIN <br />0 <br />150=2/0 <br />200=4/0 <br />in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND Disconn ct <br />SERVICE BY POWER CO. _ject, <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER FrI WITH CODE APPROVI <br />NEC 17,250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser DiagraM REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1.5" VTR —111 3" VTR <br />3" VTR <br />U <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />S ITCH FOR <br />CS d b <br />DI POSAL <br />H 1 <br />_W LL <br />'t a IUC <br />X I GFI <br />DEDICATED 0 <br />RECEPTACLE FOR I <br />MICROWAVE RANGE — [GFI <br />FCI <br />r 7, ED <br />HOOD PER SPECS GFI DW IN, <br />Lw <br />­XITCHEN <br />SPEC 3 & 4 KITCHEN <br />SCALE: Y4"=l'-O" <br />A/C PAD DISC. WP <br />GFI <br />I <br />NOOK <br />LANAI <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />T-4" <br />GF11I SWITCH FOR <br />DISPOSAL FAMILY <br />&G �1 I <br />PENDANT <br />LIC AS PER ROUGH -IN FOR <br />I GFI SPECS OPT.CLG.FAN/ <br />LIGHT PRE -WIRE <br />DEDICATED 10 12 <br />RECEPTACLE FOR <br />MICROWAVE RANGE Fl. <br />3P CS <br />HOOD PER SPECS Girl Z'N .11 DW <br />GFI <br />ITCHENI\ <br />REF <br />GF <br />DINING <br />a PENDANTAS <br />4 PER SPECS <br />TO LIGHTS <br />AND <br />SWITCH S13 G <br />ABOVE d— db <br />LAU <br />D. _j PWDR <br />LL <br />FOYER <br />Fl <br />GFI GFI <br />642" <br />kWGF1 @ 44" E�1\ WGFI @ 44" <br />A.F.F. A.F . F. <br />LU LU <br />F- r) <br />LLJ Z <br />0 <br />DB <br />LU C) <br />> _j <br />- - - - - - - - - - <br />-1 - - - - - - - - - - - - - - - - - - - <br />Z LU \GARAGE <br />0 Z <br />i­- [� 1\� ENTRYi <br />< WIP <br />0 _j ARAGE GFI - - - - - DB & GF1 TO <br />o <br />j BE ALIGNED <br />IGHT AS <br />VERTICALLY <br />0 PER SPECS <br />LU <br />_j <br />> Uj <br />GARAGE <br />WIP- - - - - - - - - - - - - - - - DOOR - - - - - - - - - - - - - --- <br />GF1 GFI <br />I\ —IRRIGATION <br />GFI @ 44" <br />A.F.F. <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />COACH LIGHTS --'COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - <br />FIRST FLOOR ELECTRICAL PLAN —A SECOND FLOOR ELECTRICAL PLAN —A <br />C-9 <br />cll� <br />C-4 <br />cc <br />=61 <br />Cc <br />In <br />CD <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition, Engineers signature and sea] is only for <br />the structural engineering portions of the drawing pages beadng <br />ngineer's signature and seal. <br />CD E <br />C:) ") 8 <br />0 <br />'0' C� <br />C) <br />00 <br />00 U) <br />D LO <br />'g <br />CN C) <br />Or ' <br />j LL uj <br />LL ILL I a. <br />_j Lu <br />EL �e <br />N 8 <br />W <br />IL <br />co LLJ <br />Cc 0 . <br />L0 on Z < <br />C14 0 <br />d 6 <br />Z <br />W <br />0 U) <br />El El <br />0 <br />IEEE] <br />_�o <br />00 CD <br />Cq <br />in-MAI <br />Q�p <br />U0 <br />CD <br />LU <br />0 <br />V) <br />V) <br />LU <br />U) <br />E <br />C) 0 <br />U) <br />< <br />C:) <br />C.0 <br />co <br />Z <br />Z< <br />_j <br />ILL. <br />c6 E <br />CD- 0 <br />Z <br />< <br />Z a <br />E u <br />Ca <br />Z <br />F- 0. <br />E <br />20 <br />� ii <br />, <br />Q0 <br />-0 <br />0 < <br />ow Z <br />It <br />< 0 <br />.0 <br />1, <br />O� <br />0, <br />Z <br />�z <br />W <br />1`0 <br />L <br />U) <br />0 Im <br />0 <br />1Z <br />�O <br />< <br />C) <br />< <br />�Im <br />0 <br />C:) <br />bi <br />OM <br />C: <br />2 C:) <br />Ce) <br />SO <br />(D <br />co <br />>11 <br />CY) <br />:3 0 <br />cc <br />co <br />C) <br />L) <br />U) 2 <br />3: <br />N <br />_0 <br />4:t <br />co N <br />C) <br />10 <br />0.) <br />L0 <br />Nr <br />(0 <br />. <br />(D <br />E <br />CIO <br />00 <br />C; <br />Z <br />cc <br />Z <br />E T__ <br />- <br />co <br />E <br />0 <br />< <br />_j <br />JOB <br />NO: <br />22-09401 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />­,,V p­ <br />4 <br />