My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36504 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36504 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 6:35:26 PM
Creation date
2/18/2025 4:16:04 PM
Metadata
Fields
Template:
Building Plans
Street #
36504
Location
Flats St
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
X <br />2 <br />2 <br />2 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />NEMA I <br />ISO AMP/ <br />200 AMP <br />#14 to NhIs & outlets <br />#12 to apphances and GFI <br />#1 OtOWH <br />#8 to Range <br />#6 to HVAC <br />p jr2=4'100 in 2"Condult <br />200 am <br />150 amp <br />Is nn <br />UNDERGROUND_jn <br />SERVICE BY POWER CO. KIT� <br />4 Bare Cu Ground I <br />INTERSYSTEM A� <br />BONDING *4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17,250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES Typical 150-200 Amp Electrical Riser DiagraM REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1. Elect" iouL,eL"eig"Ltiasmeasuit:uFum"nis"eu"oorto nter line ol the IJOX to LM: 10 Arr kgenerail. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36"AFF <br />Exterior Waterproof 12"AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" oenterline above finished floor. <br />4. Electrical plan is intended for bid purposes only, All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would Include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range Is not to be Included In the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FfF <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />pi-MF HALF -SWITCHED DUPLEX OUTLET <br />I i9K SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ WALL SWITCH <br />$3 THREE-WAY SWITCH <br />�4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />F-0 WALL MOUNTED LIGHT FIXTURE <br />@) RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FCJH CHIMES (OPTIONAL) <br />49 PUSH BUTTON SWITCH (OPTIONAL) <br />F0 PUSH BUTTON SWITCH - DOOR BELL <br />@ SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNM <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />(D THERMOSTAT <br />0 ELECTRIC METER <br />-AE3- ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />A\/ <br />PLUMBING RISER_ <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE:NTS <br />BE VERIFIED WITH PLUMBER <br />OWNER'S SYITE <br />2 <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />P <br />Ll =1 <br />FAMILY RM <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />U.C. OUTLET <br />FOR DW <br />U.C. OUTLET <br />wv-- -�' I I I �' t/ 1 0& 1 1 <br />/L - - - - - - <br />CAFE G F11 E: <br />I F I I - - - - <br />I D.W. I <br />L - - - J <br />I INKiv/DIS3 <br />rO <br />TIPENDAN F <br />IPENDANT AS <br />PER SPECS <br />LO T <br />W�NG: <br />. t4A <br />DEDICATED RECEPTACLE <br />H.B. FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. VERIFY METER <br />FOR ALARM LOCATION WITH <br />BUILDER WP H.B. <br />SYSTEM 171 GFI <br />----------- <br />NrH ---- W.I.C. <br />— — — — — — — — — — — — <br />op <br />T.. <br />REF. <br />BEDROOM 2 <br />G F <br />GFI <br />SWITtH I OUGH-IN FOR <br />,_T <br />I OPT. CLG. FAN/ <br />WI <br />R J[ J LIGHT PREJ IRE <br />/10 <br />' -1 IRRIGATION <br />VERIFY LOCATION YaFl @ 44" A.F.F. <br />.H. <br />Dw ELECTRICAL PANEL <br />0 <br />2 CAR GARAGE <br />GFI FOR <br />GAR. DOO� <br />GFI <br />GF1 @ 44" <br />A.F.F. <br />L— — — — — — — — — — — — JJ <br />GFI @ 44" <br />A. F. F. <br />Oyl---- it <br />irv- <br />ENTRY <br />i#WP <br />_$3 IIIIIII I III -II I I] 1 11 111111111111111111 <br />------------ <br />SED) S. D. <br />.D. <br />db <br />(4) J =E <br />S. D. F <br />�8 BEDROOM 4 <br />BEDR`f%J"1OM 3) <br />ROUGH -IN FOR <br />^OPT. CLG. FAN/ <br />�IGHT PRE -WIRE <br />ROUGH -IN FOR I <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />ELECTRICAL PLAN - ELEV-Bl_ <br />SCALE: Y4"= V-0" <br />C" <br />C'j <br />C"4 <br />to <br />CID <br />qp'.= <br />"' ICU <br />CD <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />dition. Engineers 31gnature and <br />seal Is only for <br />the structural engineering portions of the drawing pages beadng <br />EngIneer's signature and seal. <br />L 5 C'4 60 <br />Q 0 49 G � I <br />W) <br />N "' <br />cc <br />0 r- I-- L5 <br />-j <br />LL <br />0 <br />W <br />Lu a. <br />S2 <br />wg <br />M <br />a. <br />5 0 <br />21 t <br />Z 2 0 <br />LLW <br />CL <br />04 <br />a < <br />r') <br />W <br />00 <br />0 <br />< <br />V) <br />CD <br />4-J <br />LU <br />U <br />0 U, <br />V) <br />V) <br />L ' U <br />< <br />r- <br />co <br />E <br />P <br />'0 <br />E 0 <br />Z <br />E <br />C-4 <br />t <br />C <br />Z <br />Z <br />Z <br />W <br />CL <br />Z <br />M10 <br />Z M <br />C <br />.2 0 <br />LO <br />LO <br />cc <br />< <br />p- <br />CIO <br />M <br />C:) <br />:3 L0 <br />LO <br />_j <br />Cr T'— <br />U) .2 <br />co 4- <br />L0 <br />U) <br />0 .4 CN <br />0) <br />1 <br />04 <br />o <br />ILL <br />0) <br />L0 CN <br />Ir- <br />E <br />Ito <br />Ct) <br />co <br />0 <br />(a <br />Z <br />�i <br />E 0 al <br />E 41 <br />'V <br />W <br />r- <br />CL <br />0 -0 <br />0 < <br />0) <br />-J <br />JOB <br />No 22-12368 <br />SCALE : AS NOTED <br />SHEEr NO. <br />4 <br />.1. 1 Aj <br />
The URL can be used to link to this page
Your browser does not support the video tag.