Laserfiche WebLink
3� <br />C" <br />2 <br />2 <br />0 <br />(9 <br />7 <br />�n <br />LO <br />E <br />8 <br />02 <br />C", <br />.1 <br />�C_4 <br />c'4 <br />CROSS BRACING DETAIL (TY <br />SCALE:NTS <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1 . WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS 1311—�j <br />I <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />VVI I WU %W I I I V".&j <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.C. <br />2x8 BLOCKING NAILED @ <br />EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />PRE-ENG. TRUSS <br />2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP <br />MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />----Z—WOOD TRUSS —j <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE:NTS <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />Ak VARIES W/ <br />4v ROOF SLOPE <br />2X4 CONT. W1 (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />—TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL <br />SCALE:NTS <br />DIAGONAL <br />AT 8'-0" <br />MAX <br />TRUSS <br />0,,,—ROOF <br />SEE <br />SHEATHING <br />PLAN <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />N SHI <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />TRUSS <br />�'A <br />(2) 12D NAILS — <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE:NTS <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />1 Od TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 (2) #7 x 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A W/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2-4-O.C. MAX. W/ (3) 1 Od <br />COMMON TOENAILS TO TIE BEAM <br />2X4 CONT. AT—/ CONC.MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A —A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />SCALE:NTS <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />VARIES -A*= <br />ROOF SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 #2 SPF BRACING @ <br />16" O.C. W/ (4) 12d COMMON TRUSSES. <br />TOENAILS TO TOP <br />SEE TRUSS PLAN <br />PLATE & (2) 12d END M IN. (2) 2x4 FOR CONNECTION <br />NAILS TO TRUSS SPFTOP INFORMATION. <br />BOTTOM CHORD I : <br />PLATE <br />dkVARIES SEE PLAN <br />FOR WALL LOCATION <br />MIN. 2x4 #2 SPF STUDS @ <br />16" O.C. W/ EXTERIOR <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE & <br />(3) 12d TOENAILS TO <br />SEE PLAN FOR <br />PLATE BELOW <br />TOP OF WALL <br />MIN. 2X4 #2 SYP P.T. PLATE <br />4 <br />W/ 1/2"X8" EPDXY ANCHOR <br />MASONRY WALL SEE <br />@ 3" FROM EACH END & <br />PLAN FOR MORE <br />16" O.C. MAX. <br />INFO. <br />SECTION <br />@ ENTRY <br />SCALE:NTS <br />SIMPSON LSTA18 <br />wl (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TIE <br />BEAMS TOGETHEF; <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF( <br />HIP <br />G.T <br />(2) 2x8 #2 SYP w <br />O.S.B. FLITCH Pi <br />TOP @ TRUSS 8 <br />U.N.O. ON ROOF <br />PLAN <br />TYPIC <br />WALL <br />NOTE: PENDING BEAM <br />BEARING LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLUMN w/ (2) SIMPSON <br />HTS20 w/ (24) 1 Od x 1 1/2" <br />NAILS EACH <br />SIMPSON HU46/HUC46 w/ (8) <br />16d NAILS TO POST (4) 10d <br />NAILS TO BEAM <br />SUPPORT COLUMN BUILT-UP <br />(2) 2x4's OR 4x4 w/ (2) 1 Od <br />NAILS @ 8" O.C. EACH PLY <br />(SHOWN AS 4 x 4) <br />(2) SIMPSON HETA20 w/ (8) 1 Od <br />x 1 1/2" NAILS EACH - OR (2) <br />SIMPSON MSTAM36 w/ (7) 10d <br />& (4) 1/4"x2 1/4" TITENS EACH <br />TIE BEAM <br />BEAM @ RAISED ENTRY <br />4 <br />MASONRY WALL rl�A <br />SCALE:NITS <br />SIMPSON HUC410 w/ (14) <br />jSEE PLAN 6 <br />FOR cANT1 <br />16d INTO HEADER & (6) — <br />1 <br />10d INTO BEAM - SEE <br />ROOF PLAN FOR MORE <br />INFO <br />x x N x <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE& BASE <br />_e <br />OSI3 FLITCH PLATE <br />CONNECTION INFO <br />REQ'D ONLY WHEN <br />`:7��7/16" <br />INDICATED ON BM. <br />SCHEDULE/PLAN <br />OSI3 FLITCH PLATE <br />SEE FLOOR PLAN <br />FOR <br />RECI'D ONLY WHEN <br />COLUMN SIZE& Bh <br />SE <br />j <br />_ <br />INDICATED ON BM. CONNECTION INFO <br />OPTION A <br />SCHEDULE/PLAN OPTION B <br />OPTION C <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />, <br />. <br />. <br />COMMON BM. TO POST ATTACHMENT <br />SCALE: 3/4"=V-171" <br />SIMPSON MTS18 W/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A F_� A <br />SEE PLAN FOR <br />SEE PLAN FOR <br />CANTILEVER IF <br />INDICATED <br />CORNER SEE FOUNDATION <br />. r— PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE:NTS <br />I <br />2X4 STUDS W/ SIMPSON <br />SP1 W/ (10) 1 Od NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />EXTERIOR SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 BASE PLATE W/ <br />SIMPSON LSTA30 W/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 W/ <br />(14) 1 Od x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION @ FLOOR <br />CONNECTION r22*')i <br />SCALE:NTS <br />SEE 1/S5 FOR — <br />ADDITIONAL <br />OUTLOOKER <br />INFO. <br />SIMPSON <br />MTS1 8 W/ (14) <br />1 Od NAILS <br />TYP. U.N.O. <br />TRUSS- <br />1/2" PLYWOOD <br />(2) 16d NAILS TO <br />EACH COMMON <br />TRUSS/ FRAMING <br />TYP TOP & BOTTOM <br />BM. SPLICE OVER <br />CENTER OF POST <br />MIDDLE <br />SEE PLAN FOR <br />8d NAILS AT VALLEY TRUSS <br />4" O.C. INFO. <br />4 <br />MASONRY WALL BELOW: SIMPSON <br />HETA1 6 w/ (9) 1 Od x 1 1/2" NAILS @ <br />MASONRY WALL 4'-0" O.C. TO GABLE TRUSS <br />OR BEAM BEAM BELOW: SIMOSON HTS20 W/ <br />SEE TRUSS PLAN (24) 1 Od x 1 1/2" NAIL8 @ 4'-0" O.C. <br />TO GABLE TRUSS <br />COMMON TRUSS <br />SEE ROOF PLAN <br />t <br />FOR CONNECTION <br />SECTION AT HIP GABLE rj_2`� <br />SCALE: NTS <br />EXTERIOR <br />ATTACHED' <br />SCHEDULE <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE PLAN <br />FOR BEAM SIZE <br />2x SPF #2 <br />AT 16" O.C. <br />BUILDER FRAME <br />RADIUS <br />AS REQUIRED <br />ENT <br />KNEEWALL RY FRONT WALL <br />SCALE:NTS <br />2X4 #2 SYP NAILER. NAIL <br />TO STUDS W/ (3) 16d AT <br />EACH STUD - TOENAIL ROOF AND EXTERIOR <br />EACH TRUSS TO NAILER SHEATHING ATTACHED <br />W/ (3) 1 Od PER NAILING SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />W/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY <br />W/ (3) ROWS OF 16d <br />NAILS AT 24" O.C. <br />SIMPSON LUS26 W/ (8) 1 Od NAILS <br />OR IF 2 PLY TRUSS SIMPSON <br />ZSEE FLOOR FRAMING PLAN <br />LUS26-2 W/ (8) 16d NAILS TO <br />LEDGER AND J/S6 FOR MORE INFO. <br />VERIFY WITH PLAN FOR <br />2X1 0 #2 SYP CONT. LEDGER W/ (3) LOCATION AND DIRECTION <br />1/2" X 4 1/2" LAG SCREWS ATTACH <br />(IF PARALLEL SEE 2/D2 FOR <br />LAG SCREWS INTO END OF EACH BLOCKING INFO) <br />FLOOR TRUSS, 24" O.C. MAX. (AT <br />EACH SIDE OF G.T. INSTALL (4) LAG MASONRY WALL <br />SCREWS EACH SIDE) (TYPICAL) <br />9 <br />SECTION AT LOW ROOF <br />SCALE:NTS <br />LOW ROOF/WALL—­­� <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />2x STUDS @ 16" O.C. <br />W/ SIMPSON SP1 W/ (10) 1 Od <br />NAILS AT BASE & SIMPSON <br />SP2 W/ (12) 1 Od NAILS AT TOP <br />2x BLOCKING BETWEEN STUDS <br />TO TRUSS W/ (2) 12d TOENAILS <br />EACH END (BETWEEN TRUSSES <br />(2) 12d NAILS TO EACH VERTICAL <br />STUD) <br />2x BASE PLATE W/ (2) 12d <br />" O.C. ALONG W/ <br />NAILS @ 16 <br />SIMPSON MTS12 W/ (14) 10d X <br />1 1/2" NAILS TO BLOCKING <br />BELOW @ 16" O.C. <br />PLYWOOD <br />FLOORING <br />I OW Pr)r)F: TPI M__!Q vwv/---//// �n!Q r, T <br />RAISED BOTTOM CHORD 2nd FLOOR WALL w/ SEE PLAN <br />EXTENSION SEE TRUSS SIMPSON LUS24-2 W/ (16) <br />MANUF. SPEC'S FOR 16d NAILS AT EACH END <br />CONNECTIONS TO G.T. <br />SECTION @ BUMP OUTK'39'� <br />SCALE: NTS <br />DETAILS & SECTIONS <br />C* <br />Cz <br />C3 <br />CM <br />LU <br />Q1:6 <br />LL. <br />LA� <br />a-.2 W <br />W,fM* <br />E <br />a:: <br />c: r= <br />c. <br />_T <br />CA- <br />11111�11 <br />f"I I A i W� <br />'0 <br />a <br />U <br />U <br />5 <br />)s <br />F L <br />��OFESSIO <br />TO the best at the Engineers knowledge, Information and belief, <br />th�e structural plans and specifications contained within these <br />d wings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seat is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />0 <br />11111 <br />Ifi <br />04 6 2) <br />2 <br />4 — 2% <br />:000-i-L 32 2 n <br />0 <br />.4 <br />N 0 <br />.6 -, ! <br />qu_u- U, <br />0 a <br />-6 Do- 14 <br />C <br />-, 2 i <br />W <br />0 <br />0 0 <br />8 <br />W <br />2 < <br />N M <br />z <br />< <br />W <br />013 <br />0 <br />$ <br />;z <br />z <br />z <br />Iola <br />C <br />U) <br />v) <br />(1) <br />z <br />0 <br />4--J <br />ro <br />C_/3 <br />LU <br />0 <br />(2-1 <br />< <br />T­ <br />U_ <br />2[ E <br />K 0 <br />E 8 <br />9 <br />U <br />z <br />E <br />C14 <br />_6 t <br />'5 <br />C <br />zz <br />W <br />3: <br />3� <br />C) <br />Lh <br />LO <br />LO <br />M <br />j M <br />co <br />C) <br />Cr <br />W <br />IT- <br />co <br />L0 <br />0 <br />C'i <br />04 <br />0) <br />0 <br />.0 <br />-0 <br />04 <br />L0 <br />CY> <br /><If— <br />LO C14 <br />T— <br />E <br />0) <br />(0 T_ <br />CV) <br />z <br />M <br />z <br />C <br />3 <br />E T— <br />E <br />0 <br />0 3 <br />:02 <br />JOB <br />NO: <br />22-12363 <br />SCALE <br />AS NOTED <br />SHEET NO. <br />D <br />