1.0 <br />fl- <br />u-) <br />cN <br />Q <br />co <br />40 <br />1 <br />Cr <br />:Z <br />to <br />�3 <br />C'4 <br />Lf) <br />in <br />V) <br />Lei <br />t2 <br />-3t: <br />C -1 <br />f,4 <br />FL <br />ei: <br />U-1 <br />C14 <br />U') <br />150At200A INDOOR <br />ELECTRICAL SPECIFICATION PANEL CENTER <br />NOTES: 0 0 14 to lights & outlets <br />NEMA 1 0 #12 to appliances and GFI <br />I so pf <br />ELECTRICAL CONTRACTOR 200AAMMP 0 #10 to WH <br />MUST VERIFY WITH THE 00 #8 to Range <br />SPECIFICATIONS FOR THE TYPE 0 06 to FfVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR METER <br />LOCATION PURPOSES. MAIN 50�2 <br />U r2oo=4'100 In 2" Conduit <br />200 amp <br />150 amp <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44"AFF <br />Bathroom 39"AFF <br />Laundry Room 36"AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42' centedine above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.11 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/Garbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4601.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6'of <br />the outside edge of a sink. This would include the receptacle Installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The Width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />I ELECTRICAL KEY I <br />1LZ7-1L <br />PE5-- <br />DUPLEX CONVENIENCE OUTLET <br />I Z±�' <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />K I ::% <br />.P. <br />WEATHERPROOF DUPLEX OUTLET <br />�&G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />[1� <br />HALF -SWITCHED DUPLEX OUTLET <br />I <br />r'1:th1V <br />SPECIAL PURPOSE OUTLET <br />4a <br />DUPLEX OUTLET IN FLOOR <br />K�r= <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�-o <br />WALL MOUNTED LIGHT FIXTURE <br />@) <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />I W11 <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FC H] <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />Ifq <br />TELEVISION (OPTIONAL) <br />FTq 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />Q�� 0 <br />-& <br />6j% <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />UNDERGROUND <br />SERVICE BY POWER CO. <br />— 4 Bare Cu Ground <br />INTERSYSTEM <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION HEH <br />WITH CODE APPROVED <br />NEC 17,250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />RECEPT. <br />FC <br />SECOND FLOOR ELECTRICAL PLAN — ELEV—Al <br />SCALE: Y4"=1'-0" <br />CrIll <br />C= <br />U.11 <br />C;, <br />Co 4j <br />in 0 C* <br />.4c C14 <br />CP 0, <br />r= <br />C2 <br />CC <br />L.) CP <br />40 <br />OJ <br />C131 <br />C%j <br />4=1 <br />To the best of the Engineers knowledge, Information and Mief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition, Engineers signature and seal <br />Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />E <br />c") 8 <br />0 <br />'50 <br />CN 0 <br />LL U- <br />-d ;; Q. 52 <br />Z C <br />103 <br />.2 9 <br />i t McZi �; <br />W 2 1--;;! 1 <br />(2 <br />IL 0 C'Z�r_ <br />LL <br />a 04 . . < � 0 <br />0 (.) <br />Z 0 8 <br />W 13 0 <br />0 <br />V) <br />LL- <br />c2l <br />0 LU <br />ZA C-- C14 <br />U*) i <br />Q) <br />C-- I I <br />mid <br />E <br />23 <br />0 <br />U <br />Z 0 <br />E <br />ro <br />52 <br />8 <br />10 <br />Z <br />Z <br />t0 <br />Z <br />M <br />0 <br />'6 <br />Z <br />'Z <br />Z <br />0 <br />'6 <br />6 <br />W <br />So <br />S2 <br />C <br />C) <br />LO <br />LO <br />o CO <br />ZZ <br />C) <br />T— <br />Cr . . = <br />r— <br />IS co <br />M <br />co <br />4-0 C <br />LO <br />< <br />+-j 0 <br />0 '2 <br />0) <br />LO <br />ca co <br />LO <br />04 <br />c) <br />CNI <br />LO <br />C%4 <br />E <br />M <br />Z <br />E <br />a. 1 <br />E <br />0 0 'a M <br />0 -j --- < a I <br />C <br />0 <br />-j <br />JOB <br />NO 23-06142 <br />SCALE : AS NOTED_ <br />SHEEr NO. <br />4.2 <br />