Laserfiche WebLink
_7W <br />ENGINEER'S NOTES: <br />1, DESIGN WIND SPEED: 140 MPHu(t / 110 MPHosol , 3 sec gust <br />PER ATC HAZARDS BY LOCATION <br />2, RISK CATEGORY PER FBC 17 6TH EDITION Table 1604.5 : II <br />3, EXPOSURE CATEGORY = <br />//B# <br />4, INTERNAL PRESSURE COEFFICIENT <br />0.18 <br />5, COMPONENTS & CLADDING DESIGN PRESSURES <br />FIGURE 30.5-1 <br />(R 11 El F) <br />ZONE 11a: <br />+101-21 <br />psf <br />ZONE 2a: <br />+10/-37 <br />psf <br />ZONE 3a: <br />+10/-55 <br />psf <br />(WALLS) <br />ZONE 41a: <br />+21/-23 <br />psf <br />ZONE 5b: <br />+211-27 <br />psf <br />(ENCLOSED BLDG) <br />PER ASCE 7-10: <br />GENERAL NOTES <br />BUSINESS GROUP B 393 SU FT/100 4 PEOPLE PER TABLE 100412 FBC <br />GROUP S LOW HAZARD 2007 SQ FT/500 4 PEOPLE PER TABLE 100412 FBC <br />3 SUITES @ 2400 = 7200 SQ FT <br />INTERIOR REQUIREMENTS <br />FLAME SPREAD/SMOKE DEV,—EXIT ACCESS UNSPRKi TYPE 'B' FLAMESPREAD 26-75 SMOKE DEV, 0-450 <br />FLAME SPREAD/SMOKE DEV.—EXIT ACCESS SPRK, TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV. 0-450 <br />FLAME SPREAD/SMOKE DEV,—OTHER SPACES UNSPRK, TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV, 0-450 <br />FLAME SPREAD/SMOKE DEV,—OTHER SPACES SPRK, TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV, 0-450 <br />W <br />W <br />TABLE 803.11 <br />INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk <br />ZONING CLASSIFICATION: <br />BUILDING AREA: 7200 SQ.FT. <br />BUILDING USE: BUSINESS <br />SPECIAL OCCUPANCY: N/A <br />GROUP: GROUP B <br />TYPE OF CONSTRUCTION: 3B <br />MIXED CONSTRUCTION: NO <br />BUILDING HEIGHTi <35' <br />SPRINKLED: NO <br />APPLICABLE BUILDING CODES <br />TOTAL <br />FLORIDA BUILDING CODE (FBC) 6th ed, BUILDING (2017) <br />FLORIDA BUILDING CODE (FBC) 6th ed, MECHANICAL (2017) <br />FLORIDA BUILDING CODE (FBC) 6th ed, ENERGY (2017) <br />FLORIDA BUILDING CODE (FBC) 6th eel, PLUMBING (2017) <br />FLORIDA FIRE PREVENTION CODE 6th ecl,(2017) <br />NATIONAL Fl. ECTRICAL CODE, 2014 EDITION <br />FLORIDA ACCESSIBILITY CODE 6th eel, (2017) <br />AMERICANS W/DISSABILITIES ACT (ADASAD), ed, (2,110) <br />FIXTURES SHOWN MEET REQUIREMENTS <br />GROUP <br />SPRINKLERED <br />NONSPRINKLERED <br />Interior exit stairways and rcmprzorrIdors <br />and exit passageways a,b <br />and <br />enclosure for exit <br />access stairways <br />and ramps <br />Rooms and <br />enclosed <br />spaceF5 <br />Interior exit �;tairways <br />ramps and exit <br />passageways a, <br />a6drrldors ond <br />enctosure for ext <br />access stairways <br />and ramps <br />Rooms and <br />enclosed <br />spaces c <br />A-1 & A-2 <br />B <br />B <br />C <br />A <br />Ad <br />Be <br />A-3f, A-4, A-5 <br />B <br />B <br />C <br />A <br />Ad <br />C <br />(B) E, M, R-1 <br />B <br />C <br />C <br />A <br />B <br />C <br />R-4 <br />B <br />C <br />C <br />A <br />B <br />B <br />F <br />C <br />C <br />C <br />B <br />C <br />C <br />H <br />B <br />B <br />C9 <br />A <br />A <br />B <br />I-1 <br />B <br />C <br />C <br />A <br />B <br />B <br />1-2 <br />B <br />B <br />....................... . . . . . b <br />�T <br />A <br />A <br />B <br />1-3 <br />A <br />Ai <br />C <br />A <br />A <br />B <br />1-4 <br />B <br />B <br />Bh.I <br />A <br />A <br />B <br />R-2 <br />C <br />C <br />C <br />B <br />B <br />C <br />R-3 <br />C <br />C <br />C <br />C <br />C <br />C <br />0 - <br />C <br />C <br />C <br />B <br />B <br />C <br />U <br />No restrictions <br />No restrictions <br />For SI, 1 Inch = 25.4 mm, 1 square foot = 0.0929 m2. <br />a.Class C Interior finish materials shalt be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area In the grade <br />Lobby where applied directly to a noncombustliote base or over furring strips applied to a noncombustible base and f1reblocked as required by Section 803.13.1. <br />b1n other than Group 1-3 occupancies In buildings less than three stories above grade plane, Class B Interior finish for nonsprInktered buildings and Class C <br />Interior finish for sprinktered bultdings shalt be permitted In Interior exit stairways and ramps, <br />c,Req u'reme nts for rooms and enclosed spaces shalt be based upon spaces enclosed by partitions. Where a fire -resistance rating Is required for structural <br />elernen ts, the enclosing partitions shalt extend from the floor to the ceiling. Partitions that do not comply with this shalt be considered enclosing spaces <br />Ono, t he rooms or spaces on both sides shalt be considered one, In determining the a <br />aflpticabte requirements for rooms and enclosed spaces, the specific <br />occupancy thereof shalt be the governing factor regardless of the group cLassific on of the building or structure, <br />d,Lobby areas In Group A-1, A-2 and A-3 occupancies shalt not be less than Class B materials, <br />e.CLass C Interior finish materials shalt be permitted In places of assembly with On occupant Load of 300 persons or Less, <br />f.For places of religious worship, wood used for ornamental purposes, trusses, paneling or chance( furnishing shalt be permitted, <br />g.C(ass B material Is required where the building exceeds two stories, <br />h.CLass C Interior fIn1sh materials shalt be permitted In administrative spaces, <br />I.C(ass C Interior finish materials shalt be permitted In rooms with a capacity of four persons or Less. <br />J,Class B materials shalt be permitted as wainscotting extending not more than 48 Inches above the finished floor In corridors and exit access stairways and ramps. <br />k.Finish materials cis provided for In other sections of this code. <br />I.Applies when protected by an automatic sprinkler system Installed in accordance with Section 903,311 or 903,312. <br />INTERIOR FINISH SCHEDULE <br />INTERIOR FINISHES TO BE DETERMINED BY OWNER <br />RESTROOM FLOORS TO BE A NON ABORBENT MATERIAL <br />RESTROOM WALL TO BE A NON ABSORBENT MATERISL <br />MINIMUM 41r A.F.F. <br />THIS DRAWING HAVE BEEN DESIGNED TO CONFORM 70 THE 20`17 FLORIDA BUILDING CODE <br />STH EDITION <br />N <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS. PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5M INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS TW 8 INCHES IM ALL FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />WIND <br />BUILDING 18 DESIGNED To CONFORM To ASCE 7-10. CHAPTERS 25 THRU 31, PER 2014 FLORIDA <br />BUILDING CODE, AND 2014 FLORIDA BUILDING CODE 5TH ADDITION SECTION 1W9 I I <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - 0 <br />BUILDING RISK CATEGORY - 11 <br />MEAN ROOF HEIGHT W OR -LESS <br />HEIGHT t EXPOSURE ADJUSTMENT <br />COEFFICIENT a 1.0 <br />ENCLOSED BULMNG <br />INTERNAL PRESSURE COEFFICIENT 0 18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS. EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602 5 <br />BUILDING <br />ZONE <br />ROOF OVERHANG <br />LOADS <br />ALL OTHER <br />COMPONENT <br />LOADS <br />I <br />NIA <br />0-37.01-405 <br />2 <br />-75.3 <br />+37.0f-U.5 <br />3 <br />-128.9 <br />+37 01-102.2 <br />4 <br />WA <br />+40 5/-a 9 <br />5 <br />wk <br />.040vu-11 <br />EXTER11OR WMDOWS & DOOR ASSEMBUES: <br />ALL MULLIONS AM ADJACENT DOORWNDOW ASSEMBLIES SHALL 13E TESTED OR ENGINEERED TO <br />TRANSFER 1.5 71MES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE <br />INSTALL ALL "NDOW Is DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONZ <br />TO ACHIEVE THE DESIGN PIR-F-191-61! <br />SAFETY GLAMNG: <br />U 97zl -1035 <br />I hereloy certify that I have reviewed this plan and found it to loc in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W, Smith, P,E, #"-)3608 <br />ENGINEER LICENCE #53608 <br />INDEX S H T # <br />1, <br />COVER <br />2, <br />FLOOR <br />PLAN <br />3, <br />LIGHT <br />PLAN <br />4, <br />POWER <br />PLAN <br />5, <br />HVAC <br />PLAN <br />6, <br />FIRE SAFETY <br />PLAN <br />7, <br />UL <br />SHEETS <br />ALLWORK SHALL Cok,rm.y INIITI-�, <br />6IFFA CODES AND STA4iDARDS <br />1EW DA <br />-j TE—LL <br />..jTy OF ZEPHYRHILLS <br />FIRE AND LIFE sAFETY EXAMINER,,6�� <br />ALL WORK SHALL COMPLY WITH PREVAILING <br />CODES FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS <br />ORDINANCES <br />PARCEL: 19-26-22-0010-00000-0130 <br />CHANCEY PARTNERS <br />3777 CORREIA DR <br />ZEPHYRHILLS, FLORIDA <br />D.W.SMITH,M.S.,P.E.#53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DR I VE—DADE C I TY, FLOR I DA 33525 <br />PHONE:813-469-2289 E-MAIL: dwsf 1pe@earth link, net <br />wyaw akrz: / / ;�-[ 6- <br />C"'t(WzVP"'*'T#*f L <br />SUMft%G ()Irl"C? A- L <br />RICK GOLLHARDT - DRAFTSMAN <br />813-781-3651 <br />rgollhardt@tampabay.rr.com <br />COVER SHEET SHEET OF <br />1 OF 7 <br />SCALE DATE JOB NO. <br />DO NOT SCALE 9 OCT 2020 <br />DESIGN/DRAWN CHECKED 2020-1003 <br />R. GOLLHARDT D. W. S., p. e. 3777 #2 <br />7 <br />