Laserfiche WebLink
ELECTRICAL - DATA - AUDIO LEGEND <br />SYMBOL <br />DESCRIPTION <br />= -C <br />Ceiling Fan <br />HQ <br />Ventilation Fans: Ceiling Mounted, Wall Mounted <br />0 g U <br />Ceiling Mounted Light Fixtures: Surface/Pendant, <br />Recessed, Heat Lamp, Low Voltage <br />Wall Mounted Light Fixtures: Flush Mounted, <br />Wall Sconce <br />eChandelier <br />Light Fixture <br />Fluorescent Light Fixture <br />240V Receptacle <br />WP G C <br />P P " <br />14 <br />11 OV Receptacles: Duplex, Weather Proof, GFCI <br />WP 3 4 <br />$ $ $ $ <br />Switches: Single Pole, Weather Proof, 3-Way, 4-Way <br />DM T <br />$ $ <br />Switches: Dimmer, Timer <br />FAV G.M.1] A <br />$ <br />Audio Video: Control Panel, Switch <br />Speakers: Ceiling Mounted, Wall Mounted <br />C5,, C51TV <br />Wall Jacks: CAT5, CAT5 + TV, TV/Cable <br />Telephone Jack <br />Intercom <br />Thermostat <br />Door Chime, Door Bell Button <br />D COISD <br />COMBINATION CO2 / Smoke Detectors: Ceiling Mounted, Wall Mounted <br />EP <br />Electrical Breaker Panel <br />UNVER6ROUND METER <br />HUB SUPPLIED BY <br />ONER COMPANY <br />MAIN <br />BREAKER <br />BOX —0 <br />C]>---_UNDF_R6ROUND CONDUIT <br />SUPPLIED BY PROPERTY <br />ONNER TO ELECTRIC H8 <br />COMPANY FEEDER LINE. 0 <br />&ROUND RODS ELECTRIC R15ER <br />NOT TO SCALE <br />BAlt! 1 <br />CE U I <br />PORCH WP %Z/1 <br />]BE61ROOM I <br />"(111C OFGI <br />0 <br />FE7!t K:= <br />0 FCI <br />KITCHEN <br />COORDINATE DINING <br />K LOC. OF---, <br />TABLE <br />BED OOM 2 <br />CE <br />SE%D <br />COORDINATE <br />N1 LOC. OF <br />ISLAND <br />ALL ELECTRICAL SHALL COMPLY WITH FLORIDA BUILDING CODE CHAPTER 27 AND NFPA 70A <br />NATIONAL ELECTRIC CODE FOR ONE AND TWO FAMILY DWELLINGS. <br />CONTRACTOR SHALL CONDUCT PRE -ELECTRICAL INSTALLATION WALK THROUGH WITH <br />HOMEOWNER TO VERIFY SPECIFIC PLACEMENT OF LIGHTS, SWITCHES, AND FANS, <br />PER NFPA 72 & FBC R314 <br />Install smoke alarms inside each bedroom, outside each sleeping area and on every level of the <br />home, including the basement. <br />On levels without bedrooms, install alarms in the living room (or den or family room) or near the <br />stairway to the upper level, or in both locations. <br />Smoke alarms should be installed at least 10 feet (3 meters) from a cooking appliance to <br />minimize false alarms when cooking & Smoke alarms shall be installed not less than 3 feet (914 <br />mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower <br />unless this would prevent placement of a smoke alarm required by other sections of this code. <br />Mount smoke alarms high on walls or ceilings. Wall -mounted alarms should be installed not more <br />than 12 inches away from the ceiling (to the top of the alarm). <br />On pitched ceilings, install the alarm within 3 feet of the peak but not within the apex of the peak <br />(four inches down from the peak). <br />Smoke alarms shall be placed not less than 36" from the tip of the ceiling fan blade and not less <br />than 36" from HVAC vents <br />ALL ELECTRICAL OUTLETS SHALL BE PLACED PER THE FBC AND NFPA 70A AS REQUIRED <br />All electrical outlets located within six feet of a sink or other water source must have a ground - <br />fault circuit -interrupter (GFCI) <br />All outlets and switches placed outdoors must be inside a weather protective box <br />Provide carbon monoxide detector within 10ft of each bedroom entrance <br />Place hard wired, interconnected smoke detectors with battery back up inside of every sleeping <br />area and adjacent hallways and living areas. <br />ALL SMOKE ALARMS SHALL BE HARDWIRED, INTERCONNECTED W/ BATTERY BACK UP <br />ALL BATHROOMS & TOILET ROOMS SHALL BE EQUIPPED WITH MINIMUM 50CFM VENTILATION <br />TO EXTERIOR OR AS REQUIRED BY FBC R303.3 <br />TYPE, STYLE, AND LOCATION OF SWITCHES AND LIGHTS SHALL BE COORDINATED BETWEEN <br />OWNER AND CONTRACTOR DURING ELECTRICAL ROUGH IN <br />OWNER TO SPECIFY LOCATION OF DATA, CABLE, AND LOW VOLTAGE WIRING DURING <br />ELECTRICAL ROUGH IN <br />LIVING <br />C <br />PORCH <br />WP <br />%&12 <br />BEDROOM 3 <br />'3 <br />AIR <br />HANDLER L:3= <br />GARAGE <br />R <br />r-- — — — — — — <br />150 AMP <br />MAIN <br />ELECTRICAL <br />PANEL <br />A/C <br />CONDENSER <br />ELECTRICAL <br />METER <br />FDJ EN&INEERING AND DESIGN, <br />LL6 <br />GERT. OF AUTHORIZATION # 30'1158 <br />FRANK@FDJEN&.GOM <br />EN(71NEERIN6 CEIRTIFICATICATION <br />I HEREBY CERTIFY THAT I HAVE REVIENED THE <br />ATTACHED DE51614 AND FOUND IT TO Be IN <br />COMPL�ANCF V41TH THE FLORIDA SUILDIN6 COVE, <br />6TH ED TION (2011) - RESIDENTIAL <br />TH15 DRAINING AND DE51614 15 VALID FOR 12 <br />MONTHS AFTER THE DATE IT 15 SIONFO AND <br />SEALED <br />THIS DRAY41NO AND DESIGN 19 SIGNED AND <br />SEALED FOR STRUCTURAL EN&INEFRIMG ONLY. <br />%amak— <br />t <br />15'. <br />vo STAT <br />F RV�?, <br />f L <br />Pki 6 <br />--L P �1 _ 4,- *016leg <br />- 2 1 1^N . <br />67FNERAL NOTES: <br />1. 67C TO VERIFY ALL ELECTRICAL <br />FIN15HF-5 AND AGGF-55ORIF-5 PRIOR <br />TO ORDER / INSTALL, TYP. <br />2. 67C, TO COORDINATE kNITH <br />ELECTRICAL CONTRACTOR AND <br />OkNNER PRIOR TO ELECTRICAL <br />ROU6H IN. <br />3. 67C, ELECTRICAL CONTRACTOR, <br />AND OVqNER SHALL CONDUCT PRE- <br />ROU67H IN VqALK THROU67H, IN ORDER <br />TO SPECIFY AN*( SPECIAL <br />ELECTRICAL REOUIREMENT5 <br />Z <br />LU <br />D <br />I <br />I <br />I <br />>__ <br />— <br />LU <br />—1 <br />ED <br />CD <br />< <br />C!k <br />I.— <br />IU <br />Z <br />> <br />Lu <br />lu <br />Cn <br />